TY - JOUR A1 - Düking, Peter A1 - Giessing, Laura A1 - Frenkel, Marie Ottilie A1 - Koehler, Karsten A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study JF - JMIR mhealth and uhealth N2 - Background: Physical activity reduces the incidences of noncommunicable diseases, obesity, and mortality, but an inactive lifestyle is becoming increasingly common. Innovative approaches to monitor and promote physical activity are warranted. While individual monitoring of physical activity aids in the design of effective interventions to enhance physical activity, a basic prerequisite is that the monitoring devices exhibit high validity. Objective: Our goal was to assess the validity of monitoring heart rate (HR) and energy expenditure (EE) while sitting or performing light-to-vigorous physical activity with 4 popular wrist-worn wearables (Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa). Methods: While wearing the 4 different wearables, 25 individuals performed 5 minutes each of sitting, walking, and running at different velocities (ie, 1.1 m/s, 1.9 m/s, 2.7 m/s, 3.6 m/s, and 4.1 m/s), as well as intermittent sprints. HR and EE were compared to common criterion measures: Polar-H7 chest belt for HR and indirect calorimetry for EE. Results: While monitoring HR at different exercise intensities, the standardized typical errors of the estimates were 0.09-0.62, 0.13-0.88, 0.62-1.24, and 0.47-1.94 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 0.9%-4.3%, 2.2%-6.7%, 2.9%-9.2%, and 4.1%-19.1%, respectively, for the 4 wearables. While monitoring EE at different exercise intensities, the standardized typical errors of the estimates were 0.34-1.84, 0.32-1.33, 0.46-4.86, and 0.41-1.65 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 13.5%-27.1%, 16.3%-28.0%, 15.9%-34.5%, and 8.0%-32.3%, respectively. Conclusions: The Apple Watch Series 4 provides the highest validity (ie, smallest error rates) when measuring HR while sitting or performing light-to-vigorous physical activity, followed by the Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, in that order. The Apple Watch Series 4 and Polar Vantage V are suitable for valid HR measurements at the intensities tested, but HR data provided by the Garmin Fenix 5 and Fitbit Versa should be interpreted with caution due to higher error rates at certain intensities. None of the 4 wrist-worn wearables should be employed to monitor EE at the intensities and durations tested." KW - cardiorespiratory fitness KW - innovation KW - smartwatch KW - technology KW - wearable KW - digital health Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229413 VL - 8 IS - 5 ER - TY - JOUR A1 - Wallmann-Sperlich, Birgit A1 - Düking, Peter A1 - Müller, Miriam A1 - Froböse, Ingo A1 - Sperlich, Billy T1 - Type and intensity distribution of structured and incidental lifestyle physical activity of students and office workers: a retrospective content analysis JF - BMC Public Health N2 - Background Physical activity (PA) guidelines acknowledge the health benefits of regular moderate-to-vigorous physical activity (MVPA) regardless of bout duration. However, little knowledge exists concerning the type and intensity distribution of structured and incidental lifestyle PA of students and office workers. The present study aimed to i) assess the duration and distribution of intensity of MVPAs during waking hours ≥50% of heart rate reserve (HRR), ii) to identify the type of PA through diary assessment, iii) to assign these activities into structured and lifestyle incidental PA, and iv) to compare this information between students and office workers. Methods Twenty-three healthy participants (11 students, 12 office workers) recorded heart rate (HR) with a wrist-worn HR monitor (Polar M600) and filled out a PA diary throughout seven consecutive days (i.e. ≥ 8 waking h/day). Relative HR zones were calculated, and PA diary information was coded using the Compendium of PA. We matched HR data with the reported PA and identified PA bouts during waking time ≥ 50% HRR concerning duration, HRR zone, type of PA, and assigned each activity to incidental and structured PA. Descriptive measures for time spend in different HRR zones and differences between students and office workers were calculated. Results In total, we analyzed 276.894 s (76 h 54 min 54 s) of waking time in HRR zones ≥50% and identified 169 different types of PA. The participants spend 31.9 ± 27.1 min/day or 3.9 ± 3.2% of their waking time in zones of ≥50% HRR with no difference between students and office workers (p > 0.01). The proportion of assigned incidental lifestyle PA was 76.9 ± 22.5%. Conclusions The present study provides initial insights regarding the type, amount, and distribution of intensity of structured and incidental lifestyle PA ≥ 50% HRR. Findings show a substantial amount of incidental lifestyle PA during waking hours and display the importance of promoting a physically active lifestyle. Future research could employ ambulatory assessments with integrated electronic diaries to detect information on the type and context of MVPA during the day. KW - incidental lifestyle physical activity KW - vigorous intermittent lifestyle physical activities KW - physical activity KW - diary KW - structured physical activity KW - context Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301217 VL - 22 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - The potential usefulness of virtual reality systems for athletes: a short SWOT analysis JF - Frontiers in Physiology N2 - No abstract available. KW - SWOT KW - virtual reality KW - athletes Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176178 VL - 9 IS - 128 ER - TY - JOUR A1 - Davidson, Padraig A1 - Düking, Peter A1 - Zinner, Christoph A1 - Sperlich, Billy A1 - Hotho, Andreas T1 - Smartwatch-Derived Data and Machine Learning Algorithms Estimate Classes of Ratings of Perceived Exertion in Runners: A Pilot Study JF - Sensors N2 - The rating of perceived exertion (RPE) is a subjective load marker and may assist in individualizing training prescription, particularly by adjusting running intensity. Unfortunately, RPE has shortcomings (e.g., underreporting) and cannot be monitored continuously and automatically throughout a training sessions. In this pilot study, we aimed to predict two classes of RPE (≤15 “Somewhat hard to hard” on Borg’s 6–20 scale vs. RPE >15 in runners by analyzing data recorded by a commercially-available smartwatch with machine learning algorithms. Twelve trained and untrained runners performed long-continuous runs at a constant self-selected pace to volitional exhaustion. Untrained runners reported their RPE each kilometer, whereas trained runners reported every five kilometers. The kinetics of heart rate, step cadence, and running velocity were recorded continuously ( 1 Hz ) with a commercially-available smartwatch (Polar V800). We trained different machine learning algorithms to estimate the two classes of RPE based on the time series sensor data derived from the smartwatch. Predictions were analyzed in different settings: accuracy overall and per runner type; i.e., accuracy for trained and untrained runners independently. We achieved top accuracies of 84.8 % for the whole dataset, 81.8 % for the trained runners, and 86.1 % for the untrained runners. We predict two classes of RPE with high accuracy using machine learning and smartwatch data. This approach might aid in individualizing training prescriptions. KW - artificial intelligence KW - endurance KW - exercise intensity KW - precision training KW - prediction KW - wearable Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-205686 SN - 1424-8220 VL - 20 IS - 9 ER - TY - JOUR A1 - Düking, Peter A1 - Fuss, Franz Konstantin A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Recommendations for assessment of the reliability, sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity JF - JMIR Mhealth and Uhealth N2 - Although it is becoming increasingly popular to monitor parameters related to training, recovery, and health with wearable sensor technology (wearables), scientific evaluation of the reliability, sensitivity, and validity of such data is limited and, where available, has involved a wide variety of approaches. To improve the trustworthiness of data collected by wearables and facilitate comparisons, we have outlined recommendations for standardized evaluation. We discuss the wearable devices themselves, as well as experimental and statistical considerations. Adherence to these recommendations should be beneficial not only for the individual, but also for regulatory organizations and insurance companies. KW - internet of things KW - activity tracker KW - data mining KW - load management KW - physical activity KW - smartwatch Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176202 VL - 6 IS - 4 ER - TY - JOUR A1 - Düking, Peter A1 - Zinner, Christoph A1 - Reed, Jennifer L. A1 - Holmberg, Hans‐Christer A1 - Sperlich, Billy T1 - Predefined vs data‐guided training prescription based on autonomic nervous system variation: A systematic review JF - Scandinavian Journal of Medicine & Science in Sports N2 - Monitoring variations in the functioning of the autonomic nervous system may help personalize training of runners and provide more pronounced physiological adaptations and performance improvements. We systematically reviewed the scientific literature comparing physiological adaptations and/or improvements in performance following training based on responses of the autonomic nervous system (ie, changes in heart rate variability) and predefined training. PubMed, SPORTDiscus, and Web of Science were searched systematically in July 2019. Keywords related to endurance, running, autonomic nervous system, and training. Studies were included if they (a) involved interventions consisting predominantly of running training; (b) lasted at least 3 weeks; (c) reported pre‐ and post‐intervention assessment of running performance and/or physiological parameters; (d) included an experimental group performing training adjusted continuously on the basis of alterations in HRV and a control group; and (e) involved healthy runners. Five studies involving six interventions and 166 participants fulfilled our inclusion criteria. Four HRV‐based interventions reduced the amount of moderate‐ and/or high‐intensity training significantly. In five interventions, improvements in performance parameters (3000 m, 5000 m, Loadmax, Tlim) were more pronounced following HRV‐based training. Peak oxygen uptake (VO\(_{2peak}\)) and submaximal running parameters (eg, LT1, LT2) improved following both HRV‐based and predefined training, with no clear difference in the extent of improvement in VO\(_{2peak}\). Submaximal running parameters tended to improve more following HRV‐based training. Research findings to date have been limited and inconsistent. Both HRV‐based and predefined training improve running performance and certain submaximal physiological adaptations, with effects of the former training tending to be greater. KW - cardiorespiratory fitness KW - eHealth KW - endurance KW - innovation KW - technology KW - training KW - wearable Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217893 VL - 30 IS - 12 SP - 2291 EP - 2304 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Zinner, Christoph A1 - Düking, Peter A1 - Sperlich, Billy T1 - Multi-Directional Sprint Training Improves Change-Of-Direction Speed and Reactive Agility in Young Highly Trained Soccer Players JF - Journal of Sports Science and Medicine N2 - The aim of this study was to evaluate the effect of a repeated sprint training with multi-directional change-of-direction (COD) movements (RSmulti) compared to repeated shuttle sprints (RSS) on variables related to COD speed and reactive agility. Nineteen highly-trained male U15 soccer players were assigned into two groups performing either RSmulti or RSS. For both groups, each training session involved 20 repeated 15 s sprints interspersed with 30 s recovery. With RSmulti the COD movements were randomized and performed in response to a visual stimulus, while the RSS involved predefined 180° COD movements. Before and following the six training sessions, performance in the Illinois agility test (IAT), COD speed in response to a visual stimulus, 20 m linear sprint time and vertical jumping height were assessed. Both groups improved their performance in the IAT (p < 0.01, ES = 1.13; p = 0.01, ES = 0.55). The COD speed in response to a visual stimulus improved with the RSmulti (p < 0.01, ES = 1.03), but not the RSS (p = 0.46, ES = 0.28). No differences were found for 20 m sprint time (P=0.73, ES = 0.07; p = 0.14, ES = 0.28) or vertical jumping height (p = 0.46, ES = 0.11; p = 0.29, ES = 0.12) for the RSmulti and RSS, respectively. In conclusion, performance in the IAT improved with the RSmulti as well as RSS. With the RSmulti however, the COD movements are performed in response to a visual stimulus, which may result in specific adaptations that improve COD speed and reactive agility in young highly trained soccer players. KW - team sport KW - COD movements KW - repeated shuttle sprints KW - speed KW - Speedcourt Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-146866 UR - http://www.jssm.org/researchjssm-15-314.xml.xml VL - 15 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans‑Christer A1 - Kunz, Philipp A1 - Leppich, Robert A1 - Sperlich, Billy T1 - Intra-individual physiological response of recreational runners to different training mesocycles: a randomized cross-over study JF - European Journal of Applied Physiology N2 - Purpose Pronounced differences in individual physiological adaptation may occur following various training mesocycles in runners. Here we aimed to assess the individual changes in performance and physiological adaptation of recreational runners performing mesocycles with different intensity, duration and frequency. Methods Employing a randomized cross-over design, the intra-individual physiological responses [i.e., peak (\(\dot{VO}_{2peak}\)) and submaximal (\(\dot{VO}_{2submax}\)) oxygen uptake, velocity at lactate thresholds (V\(_2\), V\(_4\))] and performance (time-to-exhaustion (TTE)) of 13 recreational runners who performed three 3-week sessions of high-intensity interval training (HIIT), high-volume low-intensity training (HVLIT) or more but shorter sessions of HVLIT (high-frequency training; HFT) were assessed. Results \(\dot{VO}_{2submax}\), V\(_2\), V\(_4\) and TTE were not altered by HIIT, HVLIT or HFT (p > 0.05). \(\dot{VO}_{2peak}\) improved to the same extent following HVLIT (p = 0.045) and HFT (p = 0.02). The number of moderately negative responders was higher following HIIT (15.4%); and HFT (15.4%) than HVLIT (7.6%). The number of very positive responders was higher following HVLIT (38.5%) than HFT (23%) or HIIT (7.7%). 46% of the runners responded positively to two mesocycles, while 23% did not respond to any. Conclusion On a group level, none of the interventions altered \(\dot{VO}_{2submax}\), V\(_2\), V\(_4\) or TTE, while HVLIT and HFT improved \(\dot{VO}_{2peak}\). The mean adaptation index indicated similar numbers of positive, negative and non-responders to HIIT, HVLIT and HFT, but more very positive responders to HVLIT than HFT or HIIT. 46% responded positively to two mesocycles, while 23% did not respond to any. These findings indicate that the magnitude of responses to HIIT, HVLIT and HFT is highly individual and no pattern was apparent. KW - cardiorespiratory fitness KW - endurance KW - personalized training Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235022 SN - 1439-6319 VL - 120 ER - TY - JOUR A1 - Düking, Peter A1 - Achtzehn, Silvia A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Integrated framework of load monitoring by a combination of smartphone applications, wearables and point-of-care testing provides feedback that allows individual responsive adjustments to activities of daily living JF - Sensors N2 - Athletes schedule their training and recovery in periods, often utilizing a pre-defined strategy. To avoid underperformance and/or compromised health, the external load during training should take into account the individual’s physiological and perceptual responses. No single variable provides an adequate basis for planning, but continuous monitoring of a combination of several indicators of internal and external load during training, recovery and off-training as well may allow individual responsive adjustments of a training program in an effective manner. From a practical perspective, including that of coaches, monitoring of potential changes in health and performance should ideally be valid, reliable and sensitive, as well as time-efficient, easily applicable, non-fatiguing and as non-invasive as possible. Accordingly, smartphone applications, wearable sensors and point-of-care testing appear to offer a suitable monitoring framework allowing responsive adjustments to exercise prescription. Here, we outline 24-h monitoring of selected parameters by these technologies that (i) allows responsive adjustments of exercise programs, (ii) enhances performance and/or (iii) reduces the risk for overuse, injury and/or illness. KW - biofeedback KW - eHealth KW - individualized training KW - injury prevention KW - IoT KW - periodization KW - load management Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176506 VL - 18 IS - 5 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Instant Biofeedback Provided by Wearable Sensor Technology Can Help to Optimize Exercise and Prevent Injury and Overuse JF - Frontiers in Physiology KW - sports KW - training optimization KW - performance monitoring KW - health monitoring KW - technology KW - coaching Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158044 VL - 8 IS - 167 ER - TY - JOUR A1 - Güder, Gülmisal A1 - Wilkesmann, Joana A1 - Scholz, Nina A1 - Leppich, Robert A1 - Düking, Peter A1 - Sperlich, Billy A1 - Rost, Christian A1 - Frantz, Stefan A1 - Morbach, Caroline A1 - Sahiti, Floran A1 - Stefenelli, Ulrich A1 - Breunig, Margret A1 - Störk, Stefan T1 - Establishing a cardiac training group for patients with heart failure: the "HIP-in-Würzburg" study JF - Clinical Research in Cardiology N2 - Background Exercise training in heart failure (HF) is recommended but not routinely offered, because of logistic and safety-related reasons. In 2020, the German Society for Prevention&Rehabilitation and the German Society for Cardiology requested establishing dedicated ""HF training groups."" Here, we aimed to implement and evaluate the feasibility and safety of one of the first HF training groups in Germany. Methods Twelve patients (three women) with symptomatic HF (NYHA class II/III) and an ejection fraction ≤ 45% participated and were offered weekly, physician-supervised exercise training for 1 year. Patients received a wrist-worn pedometer (M430 Polar) and underwent the following assessments at baseline and after 4, 8 and 12 months: cardiopulmonary exercise test, 6-min walk test, echocardiography (blinded reading), and quality of life assessment (Kansas City Cardiomyopathy Questionnaire, KCCQ). Results All patients (median age [quartiles] 64 [49; 64] years) completed the study and participated in 76% of the offered 36 training sessions. The pedometer was worn ≥ 1000 min per day over 86% of the time. No cardiovascular events occurred during training. Across 12 months, NT-proBNP dropped from 986 pg/ml [455; 1937] to 483 pg/ml [247; 2322], and LVEF increased from 36% [29;41] to 41% [32;46]%, (p for trend = 0.01). We observed no changes in exercise capacity except for a subtle increase in peak VO2% predicted, from 66.5 [49; 77] to 67 [52; 78]; p for trend = 0.03. The physical function and social limitation domains of the KCCQ improved from 60 [54; 82] to 71 [58; 95, and from 63 [39; 83] to 78 [64; 92]; p for trend = 0.04 and = 0.01, respectively. Positive trends were further seen for the clinical and overall summary scores. Conclusion This pilot study showed that the implementation of a supervised HF-exercise program is feasible, safe, and has the potential to improve both quality of life and surrogate markers of HF severity. This first exercise experiment should facilitate the design of risk-adopted training programs for patients with HF. KW - m exercise training KW - heart failure KW - cardiac training group KW - heart failure training group Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-266678 SN - 1861-0692 VL - 111 ER - TY - JOUR A1 - Fuss, Franz Konstantin A1 - Düking, Peter A1 - Weizman, Yehuda T1 - Discovery of a Sweet Spot on the Foot with a Smart Wearable Soccer Boot Sensor That Maximizes the Chances of Scoring a Curved Kick in Soccer JF - Frontiers in Physiology N2 - This paper provides the evidence of a sweet spot on the boot/foot as well as the method for detecting it with a wearable pressure sensitive device. This study confirmed the hypothesized existence of sweet and dead spots on a soccer boot or foot when kicking a ball. For a stationary curved kick, kicking the ball at the sweet spot maximized the probability of scoring a goal (58–86%), whereas having the impact point at the dead zone minimized the probability (11–22%). The sweet spot was found based on hypothesized favorable parameter ranges (center of pressure in x/y-directions and/or peak impact force) and the dead zone based on hypothesized unfavorable parameter ranges. The sweet spot was rather concentrated, independent of which parameter combination was used (two- or three-parameter combination), whereas the dead zone, located 21 mm from the sweet spot, was more widespread. KW - smart soccer boot KW - pressure sensor KW - sweet spot KW - dead spot KW - probability of scoring a goal KW - center of pressure KW - impact force KW - wearable technology Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-189126 SN - 1664-042X VL - 9 ER - TY - JOUR A1 - Düking, Peter A1 - Hotho, Andreas A1 - Holmberg, Hans-Christer A1 - Fuss, Franz Konstantin A1 - Sperlich, Billy T1 - Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable Technologies JF - Frontiers in Physiology N2 - Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables) provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete's training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health. KW - sports technology KW - wearable technologies KW - performance parameters KW - health monitoring KW - performance monitoring Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-165516 VL - 7 IS - 71 ER - TY - JOUR A1 - Düking, Peter A1 - Tafler, Marie A1 - Wallmann-Sperlich, Birgit A1 - Sperlich, Billy A1 - Kleih, Sonja T1 - Behavior Change Techniques in Wrist-Worn Wearables to Promote Physical Activity: Content Analysis JF - JMIR Mhealth and Uhealth N2 - Background: Decreasing levels of physical activity (PA) increase the incidences of noncommunicable diseases, obesity, and mortality. To counteract these developments, interventions aiming to increase PA are urgently needed. Mobile health (mHealth) solutions such as wearable sensors (wearables) may assist with an improvement in PA. Objective: The aim of this study is to examine which behavior change techniques (BCTs) are incorporated in currently available commercial high-end wearables that target users’ PA behavior. Methods: The BCTs incorporated in 5 different high-end wearables (Apple Watch Series 3, Garmin Vívoactive 3, Fitbit Versa, Xiaomi Amazfit Stratos 2, and Polar M600) were assessed by 2 researchers using the BCT Taxonomy version 1 (BCTTv1). Effectiveness of the incorporated BCTs in promoting PA behavior was assessed by a content analysis of the existing literature. Results: The most common BCTs were goal setting (behavior), action planning, review behavior goal(s), discrepancy between current behavior and goal, feedback on behavior, self-monitoring of behavior, and biofeedback. Fitbit Versa, Garmin Vívoactive 3, Apple Watch Series 3, Polar M600, and Xiaomi Amazfit Stratos 2 incorporated 17, 16, 12, 11, and 11 BCTs, respectively, which are proven to effectively promote PA. Conclusions: Wearables employ different numbers and combinations of BCTs, which might impact their effectiveness in improving PA. To promote PA by employing wearables, we encourage researchers to develop a taxonomy specifically designed to assess BCTs incorporated in wearables. We also encourage manufacturers to customize BCTs based on the targeted populations. KW - cardiorespiratory fitness KW - innovation KW - smartwatch KW - technology KW - wearable KW - eHealth KW - mHealth Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230556 VL - 8 IS - 11 ER - TY - JOUR A1 - Sperlich, Billy A1 - Düking, Peter A1 - Holmberg, Hans-Christer T1 - A SWOT analysis of the use and potential misuse of implantable monitoring devices by athletes JF - Frontiers in Physiology N2 - Kein Abstract vorhanden. KW - ingestible sensor KW - sensor assessment KW - implant KW - implantable neurostimulators KW - athletes Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158742 VL - 8 IS - 629 ER -