TY - JOUR A1 - Nedopil, Alexander J. A1 - Shekhar, Adithya A1 - Howell, Stephen M. A1 - Hull, Maury L. T1 - An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA JF - Archives of Orthopaedic and Trauma Surgery N2 - Introduction In total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown. Methods and Materials Two surgeons treated 21 patients with calipered KA and a PCL retaining MS implant. Validated verification checks that restore native tibial compartment forces in passive flexion without release of healthy ligaments were used to select the optimal insert thickness. A goniometer etched onto trial inserts with the ball-in-socket and the less than spherical medial conformity measured the tibial rotation relative to the femoral component at extension and 90° and 120° flexion. The surgeon recorded the incidence of anterior lift-off of the insert. Results The insert with the medial ball-in-socket and lateral flat surface restored more internal tibial rotation than the one with less than spherical medial conformity, with mean values of 19° vs. 17° from extension to 90° flexion (p < 0.01), and 23° vs. 20°-120° flexion (p < 0.002), respectively. There was no anterior lift-off of the insert at 90° and 120° flexion. Conclusion An MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space. KW - calipered KW - medial stabilized KW - spherical KW - conforming KW - insert KW - rotation KW - total knee arthroplasty KW - total knee replacement KW - kinematic alignment Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-266710 SN - 1434-3916 VL - 141 IS - 12 ER - TY - JOUR A1 - Howell, Stephen M. A1 - Gill, Manpreet A1 - Shelton, Trevor J. A1 - Nedopil, Alexander J. T1 - Reoperations are few and confined to the most valgus phenotypes 4 years after unrestricted calipered kinematically aligned TKA JF - Knee Surgery, Sports Traumatology, Arthroscopy N2 - Purpose The present study determined the postoperative phenotypes after unrestricted calipered kinematically aligned (KA) total knee arthroplasty (TKA), whether any phenotypes were associated with reoperation, implant revision, and lower outcome scores at 4 years, and whether the proportion of TKAs within each phenotype was comparable to those of the nonarthritic contralateral limb. Methods From 1117 consecutive primary TKAs treated by one surgeon with unrestricted calipered KA, an observer identified all patients (N = 198) that otherwise had normal paired femora and tibiae on a long-leg CT scanogram. In both legs, the distal femur–mechanical axis angle (FMA), proximal tibia–mechanical axis angle (TMA), and the hip–knee–ankle angle (HKA) were measured. Each alignment angle was assigned to one of Hirschmann’s five FMA, five TMA, and seven HKA phenotype categories. Results Three TKAs (1.5%) underwent reoperation for anterior knee pain or patellofemoral instability in the subgroup of patients with the more valgus phenotypes. There were no implant revisions for component loosening, wear, or tibiofemoral instability. The median Forgotten Joint Score (FJS) was similar between phenotypes. The median Oxford Knee Score (OKS) was similar between the TMA and HKA phenotypes and greatest in the most varus FMA phenotype. The phenotype proportions after calipered KA TKA were comparable to the contralateral leg. Conclusion Unrestricted calipered KA’s restoration of the wide range of phenotypes did not result in implant revision or poor FJS and OKS scores at a mean follow-up of 4 years. The few reoperated patients had a more valgus setting of the prosthetic trochlea than recommended for mechanical alignment. Designing a femoral component specifically for KA that restores patellofemoral kinematics with all phenotypes, especially the more valgus ones, is a strategy for reducing reoperation risk. KW - phenotype KW - total knee arthroplasty KW - total knee replacement KW - kinematic alignment KW - calipered KW - reoperation Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-265291 VL - 30 IS - 3 ER -