TY - THES A1 - Szewczykowski, Viktoria T1 - Definitionen und Diagnostika der periprothetischen Infektion T1 - Definitions and diagnostics of the periprosthetic joint infection N2 - Die periprothetische Infektion (PPI) ist eine seltene aber schwerwiegende Komplikation nach Implantation einer Hüftprothese. Diese Arbeit hat verschiedene Aspekte bezüglich der Diagnostik und Definition der PPI untersucht. Der primäre Fokus lag auf der mikrobiologischen Punktionsdiagnostik und seiner Korrelation mit mikrobiologischen Befunden aus intraoperativen Proben. Zudem war die Gegenüberstellung der verschiedenen Definitionen einer PPI ein weiterer Schwerpunkt der Arbeit. Des Weiteren wurden auch einige weitere Untersuchungsparameter der PPI untersucht und gegenübergestellt. N2 - The periprosthetic joint infection (PJI) is a rare but serious complication occurring after the implantation of a hip prosthesis. This work has investigated various aspects regarding the diagnosis and definition of PJI. The primary focus was on microbiological preoperative aspiration analysis and its correlation with microbiological findings from intraoperative tissue samples. In addition, the comparison of different definitions of PJI constituted another focus of this work. Furthermore, some other examination parameters of PJI were also investigated and compared. KW - periprothetische Infektion Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-299327 ER - TY - THES A1 - Will, Pia-Patricia T1 - Kurzfristiges klinisches und radiologisches Outcome nach Implantation der Knietotalendoprothese des Typs Aequos G1 unter besonderer Berücksichtigung der Patella T1 - Short-term clinical and radiological follow-up study after implantation of the knee arthroplasty type Aequos G1 with special focus on the patella N2 - Die Knieendoprothetik ist ein etabliertes Verfahren zur Behandlung der symptomatischen Gonarthose, mit welchem gute Ergebnisse erzielt werden können. Dennoch kommt es in 10-20% zu einer Beschwerdepersistenz und die aseptische Lockerung der Prothesen stellt weiterhin ein Problem dar. Als mögliche Ursache hierfür wird die unzureichend abgebildete Anatomie und Biomechanik diskutiert. Die konvex gekrümmten Femurkondylen sind nicht symmetrisch. Die Krümmungsradien nehmen von dorsal nach ventral zu. Zudem ist die mediale Gelenkfläche des Tibiaplateaus nach kranial konkav und die laterale nach kranial konvex zulaufend. Die Instabilität wird durch das vordere Kreuzband gesichert. Bei der Bewegung des Kniegelenkes kommt es zu einer Roll/Gleitbewegung zwischen Femur und Tibia. Bisher gibt es nur wenige Knieendoprothesen, die das natürliche Roll-Gleit-Verhalten des natürlichen Kniegelenkes nachempfinden. Die Aequos G1 Endoprothese berücksichtigt die Besonderheiten (mediolaterale Asymmetrie) und soll so die natürliche Kinematik besser nachempfinden. Ziel dieser Arbeit war es, Daten vom klinischen und radiologischen Ergebnis nach Implantation der Prothese innerhalb eines Jahres zu erheben. Es wurde Wert gelegt auf die Erfassung von funktionellem Outcome, gesundheitsbezogener Lebensqualität und Probleme der Patella wie dem vorderen Knieschmerz. Im Zeitraum von 2010 bis 2011 wurden 26 Patienten in einer prospektiven, klinischen Verlaufsstudie erfasst. Es erfolgte eine Untersuchung präoperativ, eine vor Entlassung aus dem Krankenhaus und nach 6 und 12 Monaten. Die Patienten wurden mittels standardisierter Fragebögen befragt und Daten erhoben zu Knee Society Score (KSS), Oxford Knee Score (OKS), Visuelle Analogskala Schmerz (VAS), Kujala- Score, Turba- Score und SF-36. Zudem erfolgten eine klinische Untersuchung und eine standardisierte radiologische Diagnostik. Das mittlere Alter der Patienten zum Zeitpunkt der Versorgung lag bei 68,77 Jahren (Min. 55 – Max. 83). Der Frauenanteil lag bei 76,92%, der durchschnittliche BMI betrug 31,48kg/m². Insgesamt konnten 22 Patienten nach 12 Monaten inkludiert werden. Eine Patientin war zum Zeitpunkt der Nachuntersuchung verstorben, eine Patientin erschien nicht zur Nachuntersuchung nach 6 Monaten, zwei Patienten erhielten einen sekundären Retropatellarersatz und schieden aus der Studie aus. Bei einer Patientin zeigte sich 12 Monate postoperativ eine Lockerung des Tibiaplateaus, es erfolgte ein Wechsel der tibialen Komponente. Eine Patientin klagte nach 6 Monaten überstarke, wirbelsäulenbedingte Beinschmerzen. Der mittlere Bewegungsumfang besserte sich nicht signifikant. Er betrug präoperativ 106,68° (±22,86°) und nach 12 Monaten 113,18° (±8,67°). Sowohl die VAS, als auch der KSS, der OKS und der Kujala-Score waren 12 Monate postoperativ hochsignifikant besser als präoperativ. Die berechnete körperliche Summenskala des SF-36 war ebenfalls hoch signifikant besser als präoperativ. Die Daten der psychischen Summenskala waren signifikant besser als präoperativ. Der subjektive Teil des Turba-Scores war hoch signifikant besser als präoperativ. Im objektiven Teil zeigte sich keine signifikante Besserung. Insgesamt zeigten sich gute postoperative Ergebnisse nach Implantation der Aequos G1 Endoprothese nach einem Jahr mit signifikanter Verbesserung der Funktions- und Schmerzscores sowie der individuellen Gesundheitswahrnehmung. Im Vergleich mit den Ergebnissen der verfügbaren Literatur, scheint die Prothese nicht unterlegen. Abzuwarten bleibt, ob sich die guten Ergebnisse langfristig bestätigen. N2 - Total knee arthroplasty is an accepted treatment of the symptomatically knee osteoarthritis with good results. But there are still 10-20% of patients with persistent disorders and the aseptic loosening of the prosthesis is still a problem. The inadequately depicted anatomy und biomechanics are discussed as possible reasons. The convex femoral condyles are asymmetrical. From dorsal to ventral the curvature radius increases. Furthermore the medial tibial plateau is concave whereas the lateral tibial plateau is convex. This instability is secured by the anterior cruciate ligament. During knee movement there is a roll/ glide movement between the femur and tibia. Until now there are only a few knee prosthesis trying to transfer this natural rolling and gliding mechanisms of the nature knee. The Aequos G1 Endoprothesis consider these specials (mediolateral asymmetry) and shall better transfer the natural kinematics. This paper was set up to get clinical and radiological results after the implantation of the total knee arthroplasty type Aequos G1 during one year follow up. There was a special attention to physical function, health-related quality of life and patella problems as the anterior knee pain. During 2010 and 2011 26 patients were included to the prospective, clinical study. Patients were evaluated preoperatively, bevor leaving hospital and after 6 and 12 months. The evaluation took place with standardized Questionnaires of the knee society score (KSS), the oxford knee score (OKS), the Visual Analog Scale (VAS), the Kujala-Score (KS), Turba Score (TS) and the SF-36. Furthermore there was a clinical examination and a standardized radiological diagnostics. The mean age at operation was 68,77 years (Min. 55 – Max. 83). The percentage of women was 76,92%, the mean BMI was 31,48kg/m². After 12 months 22 patients could be included. One patient died during follow-up, one patient refused to come to the six months follow-up examination, two patients were revised because of a secondary retro patellar arthrosis. There was one revision because of an aseptic loosening of the tibial plateau. One patient complained about severe leg pain caused by spine reasons. The mean range of motion didn’t change significantly. It was preoperatively 106,68° (±22,86°) and after 12 months 113,18° (±8,67°). The VAS, KSS, OKS and Kujala score improved highly significantly 12 months after operation. The Physical Component Summary of the SF 36 also improved highly significantly after operation. The data of the Mental Component Summary were significantly better as preoperative. The subjective part of the Turba score was highly significantly better as preoperative. There was no significant improvement in the objective part. Good postoperative results were observed after the implantation of the Aequos G1 prosthesis at one year follow up with significant better function and pain scores as well as the health-related quality of life. In comparison to the available literature, the prosthesis does not seem inferior. It remains to be seen whether the good results will be confirmed in the long term. KW - Kniegelenksendoprothese KW - Aequos G1 KW - Kinematik KW - Roll-Gleit-Mechanismus KW - kinematics KW - rolling and gliding mechanisms Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-190794 ER - TY - THES A1 - Spohn, Nicole T1 - Mittelfristige Follow-up-Studie nach Implantation einer Aequos G1 Knietotalendoprothese T1 - Medium-term follow-up study after implantation of an Aequos G1 total knee arthroplasty N2 - Durch das konkav gekrümmte mediale Tibiaplateau und das konvex gekrümmte laterale Tibiaplateau, welches zudem etwas nach dorsal versetzt ist, entsteht ein mechanisches Viergelenk. Dieses Viergelenk erzwingt im menschlichen Knie eine reibungsarme Roll-Gleitbewegung. Handelsübliche Knieendoprothesen haben dieser anatomischen Besonderheit bis dato keine Rechnung getragen. In der seit 2003 eingeführten neuartigen Knieprothese „AEQUOS G1“ wird diese anatomische Besonderheit erstmalig berücksichtigt. Bei Belastung ist die Rollbewegung die dominierende Bewegungsform und minimiert so den Materialverschleiß des Polyethylen-Inlays. Durch eine dominierende Gleitbewegung bei Beugewinkeln > 60° ermöglich diese Prothese zugleich eine maximale Flexion. Diese Arbeite beschäftigt sich mit dem klinischen Outcome und der Patientenzufriedenheit nach Implantation einer Aequos G1 Prothese in einer mittelfristigen Follow-up Studie. Die Frage, ob sich die ersten vielversprechenden Ergebnisse reproduzieren lassen, ist ebenfalls Gegenstand der vorliegend Arbeit. Es wurde bei 54 Patienten eine Implantation einer Aequos G1 Prothese durchgeführt, diese wurden in einer Monocenterstudie nachuntersucht. Die Patienten wurden nach mindestens 24 monatiger Prothesenstandzeit klinisch untersucht und mit Hilfe verschiedener Fragebögen Interviewt. Als Fragebögen wurden verwendet: der Kujala-Score (KS), der Turba-Score (TS), der Knee Society Score (KSS), die visuelle Analogskala Schmerz (VAS), der Oxford Knee Score (OKS) und der Short-Form-36 (SF-36). Es wurden 46 Patienten nach durchschnittlich 40,89 Monaten nachuntersucht. Das Durchschnittsalter belief sich auf 70,30 Jahre, bei einem Frauenanteil von 73,90 % und folglich einem Männeranteil von 26,10 %. Der durchschnittliche BMI konnte mit 32,71 kg/m² bestimmt werden. Das mittlere Bewegungsausmaß betrug in der vorliegenden Studie 108,48° ± 9,65°. Dieses Ergebnis zeigt sich nahezu identisch mit den Ergebnissen der kurzfristigen Vergleichsstudien von Frosch und Will. [15, 67] N2 - Due to the concavely curved medial tibial plateau and the convexly curved lateral tibial plateau, which is also displaced slightly posterior, a mechanical link quadrangle is created. The four link forces a low-friction rolling-sliding motion. In other commercial knee arthroplasty, this principle is not yet realized. In the "AEQUOS G1", introduced since 2003, this anatomical feature is considered for the first time. This paper deals with the clinical outcome and patient satisfaction after implantation of an Aequos G1 prosthesis in a medium-term follow-up study. The Aequos G1 prosthesis was implanted in 54 patients and the study was designed as a monocenter study. There was a clinical examination, an X-ray and an interview of the patients at the follow-up. For the Interview the following questionnaires were used: Kujala score (KS), Turba score (TS), Knee Society score (KSS), visual analog pain scale (VAS), Oxford Knee Score (OKS) and the short form 36 (SF-36). The average age was 70.30 years, with a female share of 73.90% and consequently a male share of 26.10%. The average BMI was determined to be 32.71 kg / m². The mean range of motion was 108.48 ° ± 9.65 °. KW - Kniegelenkprothese KW - Knie KW - Knieprothese KW - Kinematik KW - Viergelenk KW - Aequos G1 Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-174176 ER -