TY - THES A1 - Rasheed, Huma T1 - Development of simple and cost-effective High Performance Liquid Chromatography methods for quality control of essential beta-lactam antibiotics in low- and middle-income countries T1 - Entwicklung einfacher und kosteneffektiver Hochleistungs-Flüssigchromatographie(HPLC)-Methoden für die Qualitätskontrolle für Betalaktam-Antibiotika in Entwicklungs- und Schwellenländern N2 - Assay and impurity profiling of the pharmaceuticals are the key routine quality control methods employed worldwide for which High Performance Liquid Chromatography (HPLC) is the most widely used technique. The ability to carry out these routine laboratory procedures in low- and middle- income countries (LMICs) need the methods to be based upon simple instruments manageable with moderate levels of personnel skill and costs involved. Simple, convenient, and cost effective reverse phase HPLC methods were developed using phosphate buffer and methanol as mobile phase with C18 column as stationary phase for the impurity profiling and assay of beta lactam antibiotics. Isocratic elution and UV detection was employed in these methods. Impurity profiling method was developed for coamoxiclav tablets and ceftriaxone bulk drug. The method for ceftriaxone included a supplementary method to quantify one of its known impurity (Impurity D of ceftriaxone). This method involved use of acetonitrile where as the two main methods were achieved on the targeted method design, described above. With the exception of impurity A of ceftriaxone, the methods developed can successfully quantify impurities to the concentration as low as ≤0.05%, which is in accordance with the current guidelines for the impurity profiling of antibiotics issued by European Medicines Agency. As ensuring cost reduction was one of the key objectives of carrying out the method development exercise, in situ methods for the preparation of impurities were also identified and some new methods were introduced. The stability of beta lactam antibiotics and the choice of solvent were given due attention during the process of method development revealing information on the presence of new impurities. Deacetyl cefotaxime and 2-mercaptobenzathiazole were identified in this process as new impurities of ceftriaxone currently not listed under known impurities by United States Pharmacopoeia and European Pharmacopoeia. However, deacetyl cefotaxime is a known impurity of cefotaxime whereas the latter molecule is a degradation product of one of the synthesis impurities of ceftriaxone. This substance is reported to be carcinogenic and is resolved using the supplementary method developed for ceftriaxone, hence making its detection and quantification possible. A known inactive impurity of ceftriaxone (Impurity A, E-isomer of ceftriaxone) was` also shown to be produced by exposure to day light, thus warranting the light protection of the ceftriaxone solution, an information that is of critical importance in the clinical settings. A series of experimentation was carried out on the finished products of beta lactam antibiotics sampled from Pakistan and few other countries, to identify key quality issues in the samples. Though the limited sample size and convenient sampling did not provide results that could yield a decisive figure for the country status for prevalence of substandard and falsified medical products, but the experiments have clearly indicated that the problems in drug quality do exist and beta lactam antibiotics form a class of high-risk medicine with respect to surveillance for poor-quality medicines. Isolation of unknown impurities was also carried out along with the introduction of new and modified methods for preparation of impurities of beta-lactam antibiotics. In addition, detailed literature survey was carried out for understanding the complex problem of the poor-quality medicine, impact of poor quality antimicrobials on health care system and the magnitude of the problem at the global level. The country status of Pakistan regarding quality of medicines was recorded based upon the available documentary evidence. The current technologies and strategic options available for low- and middle-income countries in aiding fight for combating poor quality medicines was also laid down to design recommendations for Pakistan. A comprehensive review of the information technology tools used for identification and control of substandard and falsified medicines was also conducted. N2 - Für die Bestimmung der Reinheit und des Gehaltes von Arzneistoffen wird weltweit maßgeblich die Hochleistungs-Flüssigchromatographie (HPLC) eingesetzt. Damit die entsprechenden Methoden auch in Entwicklungs- und Schwellenländern angewendet werden können, müssen sie zur Verwendung mit sehr einfachen Messgeräten geeignet sein und von auch weniger gut ausgebildetem Personal durchgeführt werden können. Zudem sollten die Kosten möglichst niedrig sein. Für die Reinheitsanalytik sowie die Bestimmung des Gehaltes von Betalaktam-Antibiotika wurden einfache, praktische und kostengünstige chromatographische Methoden unter Verwendung von Umkehrphasen entwickelt, die als mobile Phase Gemische aus Phosphatpuffern und Methanol sowie als stationäre Phase C18-Säulen verwenden. Die Methoden sind isokratisch, die Detektion erfolgt mittels UV/Vis-Spektrometer. Für Coamoxiclav-Tabletten sowie den Arzneistoff Ceftiaxon wurden Methoden zur Reinheitsprüfung entwickelt. Für die Reinheitsprüfung von Ceftriaxon wurde eine zweite Methode benötigt, um eine der bekannten Verunreinigungen (Ceftriaxon-Verunreinigung D) zu quantifizieren. Hierbei musste Acetonitril als Bestandteil der mobilen Phase gewählt werden, wohingegen die beiden Hauptmethoden dem beschriebenen Methodendesign folgten. Außer im Falle der Ceftriaxon-Verunreinigung A können mit den Methoden Verunreinigungen bis zu einem Konzentrationslevel ≤ 0,05 % bestimmt werden, was den Vorgaben aktueller Richtlinien für die Reinheitsanalytik der Europäischen Arzneimittelbehörde entspricht. Da es ein Kernziel während der Methodenentwicklung war, die Kosten für die Analytik möglichst gering zu halten, wurden in situ-Methoden für die Gewinnung von Verunreinigungen entwickelt und einige neue eingeführt. Während des Entwicklungsprozesses wurde besonders auf die Stabilität der Antibiotika und auf die Wahl des Lösungsmittels geachtet, wobei Erkenntnisse über die Anwesenheit neuer Verunreinigungen erlangt werden konnten. Desacetylcefotaxime und 2-Mercaptobenzathiazol wurden als neue Verwandte Substanzen von Ceftriaxon identifiziert und sind derzeit nicht als bekannte Verunreinigen in der United States Pharmacopoeia sowie dem Europäischen Arzneibuch aufgeführt. Desacetylcefotaxime ist eine bekannte Verunreinigung von Cefotaxime, wohingegen das zweite Molekül ein Abbauprodukt einer der Verunreinigungen ist, die während der Synthese von Ceftriaxon entstehen können. Es ist bekannt, dass diese Substanz karzinogen ist, und sie kann mit der erweiterten zweiten Methode für Ceftriaxon erfasst und quantifiziert werden. Unter Lichteinfluss bildete sich zudem eine weitere bekannte, inaktive Verunreinigung von Ceftriaxon (Verunreinigung A, E-Isomeres von Ceftriaxon), weshalb Ceftriaxon-haltige Lösungen vor Licht geschützt aufbewahrt werden sollten. Dieses Wissen ist besonders für den klinischen Bereich relevant. An einer Reihe von Betalaktam-haltigen Fertigarzneimitteln aus Pakistan und einigen anderen Ländern wurden mehrere Qualitätsuntersuchungen angestellt. Obwohl der geringe Probenumfang und die Methoden der Probensammlung kein eindeutiges Bild darüber zeichnen konnte, ob in einem bestimmten Land Arzneimittelfälschungen besonders häufig auftreten, konnte durch die Versuche dennoch festgestellt werden, dass es Probleme bei der Arzneimittelqualität gibt und dass Betalaktam-Antibiotika eine Hochrisikogruppe darstellen, die besonders gut hinsichtlich des Vorkommens minderwertiger Arzneimittel untersucht werden muss. Zudem wurden unbekannte Verunreinigungen aus den Proben isoliert und neue sowie modifizierte Methoden entwickelt, um Verunreinigungen der untersuchten Substanzen zu gewinnen. Zudem wurde eine ausführliche Literaturrecherche durchgeführt, um das komplexe Problem minderwertiger Arzneimittel, den Einfluss minderwertiger Antibiotika auf das Gesundheitssystem sowie das globale Ausmaß des Problems zu verstehen. Für Pakistan wurde der status quo der Arzneimittelqualität aufgrund vorhandener Dokumentation ermittelt. Außerdem wurde dargelegt, inwiefern die heutigen modernen Technologien und Strategien, die für Entwicklungs- und Schwellenländern zur Verfügung stehen, zur Bekämpfung von qualitativ minderwertigen Arzneimitteln in Pakistan beitragen können. Hierzu wurde eine Übersicht aktueller, moderner digitaler Techniken angefertigt, die für die Aufdeckung und Bekämpfung von minderwertigen und gefälschten Arzneimitteln verwendet werden können. KW - Quality ccontrol KW - antibiotics KW - HPLC KW - LMICS KW - simple KW - HPLC KW - Low-income Countries KW - Qualitätskontrolle KW - Antibiotikum Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177214 ER - TY - THES A1 - Almeling, Stefan T1 - The use of aerosol-based detection systems in the quality control of drug substances T1 - Die Verwendung von aerosol-basierten Detektionssystemen in der Qualitätskontrolle von Arneiwirkstoffen N2 - The work presented in this thesis was mainly targeted at exploring the capabilities of evaporation based LC detectors as well as further alternatives for the control of impurities in substances not exhibiting a suitable chromophore for UV-detection. In the course of the work carried out, several new methods for the identification, impurities control and composition testing of APIs were elaborated. An evaporation based detector that entered into the field of pharmaceutical analysis in the recent years was the Evaporative Light Scattering Detector (ELSD). However, non-reproducible spikes were reported when injecting concentrated test solutions as they are usually required for the control of impurities. The reasons, for the appearance of these spikes as well as possibilities for their avoidance were explored in a systematic study. Moreover, the dependence of the detector sensitivity on different eluent composition, eluent flow-rate and ELSD settings was investigated. In the course of the revision of the Ph.Eur. monographs for aspartic acid and alanine, a C18 reversed phase ion-pair LC method using 1 mmol/L of perfluoroheptanoic acid as an ion-pair reagent and a charged aerosol detector (CAD) was developed and fully validated for the purity control of Asp. The method was capable of separating the organic acids and major amino acids known to occur as process related impurities. With a slight modification, the method was also applicable for the purity control of Ala. Based on the developed LC-CAD method for the impurity control of alanine, a comparative study of the performance characteristics of different evaporation based LC detectors, i.e. ELSD, CAD and the recently developed Nano Quantity Analyte Detector (NQAD) was carried out. Additionally, an MS detector and qNMR were included in this study. It was found that the control of impurities in Alanine at an ICH conform level could be ensured using LC coupled to CAD, MSD and NQAD detection as well as by the use of qNMR. In terms of performance, prize and ease of use CAD and NQAD were found to be the most suitable alternatives. In terms of repeatability and sensitivity, the CAD appeared slightly superior to the NQAD. The quality of streptomycin sulfate is not sufficiently controlled by the current Ph.Eur. monograph in that an appropriate test for the control of the related substances is missing. A study was carried out to develop a C18 reversed phase ion-pair LC method using pentafluoropropionic acid as an ion-pair reagent and a CAD for the identification and control of the related substances. The developed method allowed the separation of 21 impurities from streptomycin. Moreover, coupling of the method to MS allowed the identification of the separated impurities. The method was shown to be sufficiently sensitive to control the related substances with a disregard limit of 0.1% as it is normally applied in the Ph.Eur. for products derived from fermentation. Currently, the aescin content of horse-chestnut standardized dry extract is determined using a complex and laborious photometric determination. A more selective LC-UV assay determination for beta-aescin has been proposed for the Ph.Eur. draft monograph of horse-chestnut standardized dry extract. Possibilities were explored to further improve the LC-method using detection by CAD. It was demonstrated that by the use of a modified LC-CAD method several problems related to the differences in the UV-response of the various components contained in the active aescin fraction could be eliminated. Moreover the proposed reference standard strategy was reviewed. Eventually, it was demonstrated on the example of two different clusters of pharmacologically active peptides how low energy collision induced dissociation mass spectrometry (low energy CID-MS) can successfully be used for identification testing in pharmacopoeial monographs. In this respect, the combination of a direct confirmation of the molecular mass via the m/z-ratio of the molecule ions with structural sequence information obtained by low energy CID-MS experiments was found to deliver a higher degree of certainty of the identity of a given substance than the set of tests currently described in the monographs. A significant gain in efficiency and throughput and important reduction of the amount of sample consumed during testing were identified as being additional advantages of this approach. Taken together, it could be demonstrated on various examples how recent technological advancements in the field of analytical chemistry can contribute to improve the quality control of APIs. N2 - Die durchgeführten Arbeiten hatten zum Ziel, das Potential von evaporationsbasierten HPLC-Detektoren sowie weiterer moderner Techniken hinsichtlich ihrer Eignung zur Reinheitsprüfung von pharmazeutischen Wirkstoffen zu untersuchen. Im Zuge der Arbeiten wurden verschiedene neue Methoden zur Identifizierung, Verunreinigungskontrolle und zur Überprüfung der Zusammensetzung von pharmazeutischen Wirkstoffen entwickelt. Ein evaporationsbasierter Detektor, der in den letzten Jahren Einzug in die pharmazeutische Analytik gehalten hat, ist der Lichtstreudetektor (ELSD). Allerdings wurde berichtet, dass es im Zusammenhang mit der Injektion konzentrierter Testlösungen zum Auftreten nicht reproduzierbarer Spikes kam. In einer systematischen Studie wurden die Gründe hierfür ermittelt und gleichzeitig Möglichkeiten ihrer Vermeidung aufgezeigt. Darüber hinaus wurde die Abhängigkeit der Empfindlichkeit des Detektors von der Zusammensetzung der mobilen Phase, der LC-Flußrate und den Einstellungen des ELSD untersucht. Im Zuge der Revision der Monografien für Asparaginsäure und Alanin wurde eine C18-Ionenpaar-HPLC-Methode unter Verwendung von 1 mmol/L Perfluorheptansäure und Detektion mittels eines geladenen Sprühnebeldetektors (Charged Aerosol Detector – CAD) für die Reinheitskontrolle von Asparaginsäure entwickelt und validiert. Mit Hilfe dieser Methode konnten sowohl organische Säuren als auch die wesentlichen Aminosäuren, die als prozessrelevante Verunreinigungen bekannt sind, abgetrennt werden. Nach geringfügiger Modifikation konnte diese Methode auch zur Reiheitskontrolle von Alanin eingesetzt werden. Basierend auf der HPLC-CAD-Methode für Alanin wurde eine vergleichende Studie der Leistungsfähigkeit verschiedener evaporationsbasierter HPLC-Detektoren durch-geführt. Untersucht wurden der ELSD, der CAD und der kürzlich entwickelte „Nano Quantity Analyte Detektor“ (NQAD). Weiterhin wurden ein massenspektrometrischer Detektor (MSD) sowie die Quantifizierung mittels NMR-Spektroskopie (qNMR) in die Untersuchung einbezogen. Im Ergebnis war die Reinheitskontrolle von Alanin auf einem ICH konformen Niveau unter Verwendung des CAD, NQAD und MSD sowie mittels qNMR möglich. Hinsichtlich der Kriterien Leistungsfähigkeit, Preis und Benutzerfreundlichkeit waren der CAD und der NQAD die geeignetsten Alternativen. Bezüglich Wiederholbarkeit und Empfindlichkeit war der CAD dem NQAD leicht überlegen. Die Qualität von Streptomycinsulfat wird von der aktuellen Arzneibuchmonografie mangels eines geeigneten Reinheitstests nicht ausreichend kontrolliert. Aus diesem Grund wurde eine C18-Ionenpaar-HPLC-Methode unter Verwendung von Perfluorpropionsäure und Detektion mittels CAD zur Identifizierung und Kontrolle der Verunreinigungen entwickelt. Mit dieser Methode konnten 21 Verunreinigungen von Streptomycin abgetrennt und nach massenspektormetrischer Kopplung identifiziert werden. Die Methode erwies sich als ausreichend empfindlich, um Verunreinigungen mit einer Ausschlussgrenze von 0.1%, wie sie im Europäischen Arzneibuch für Fermentationsprodukte üblicherweise angewandt wird, zu kontrollieren. Derzeit wird der Aescingehalt in standardisiertem Rosskastanien-Trockenextrakt mittels einer komplexen photometrischen Methode bestimmt. Für den entsprechen-den Entwurf einer Monografie des Europäischen Arzneibuchs wurde eine selektivere HPLC-UV-Methode vorgeschlagen. Die Möglichkeiten einer weiteren Verbesserung dieser Methode unter Verwendung des CAD wurden untersucht. Es konnte gezeigt werden, dass eine modifizierte HPLC-CAD-Methode geeignet ist, Probleme, die sich aus der unterschiedlichen UV-Absorption der im Aescingemisch enthaltenen Substanzen ergeben, zu eliminieren. Weiterhin wurde die vorgeschlagene Referenzstandard Strategie überprüft. Abschließend wurde am Beispiel von zwei Gruppen pharmakologisch wirksamer Peptide nachgewiesen, wie kollisionsinduzierte Massenspektrometrie (CID-MS) erfolgreich für die Identitätskontrolle in Arzneibuchmongrafien eingesetzt werden kann. Diesbezüglich erbrachte die Kombination der direkten Massenbestätigung mittels des m/z-Verhältnisses des Molekül-Ions mit den aus dem CID-MS-Experiment erhaltenen Informationen ein höheres Maß an Gewissheit hinsichtlich der Identitätsbestätigung als die derzeit beschriebenen Tests. Als weitere Vorteile dieses Ansatzes wurden ein wesentlicher Effizienzgewinn sowie eine erhebliche Reduktion des durch die Testung verbrauchten Probenmaterials identifiziert. Zusammenfassend zeigen die Arbeiten an verschiedenen Beispielen, wie aktuelle Entwicklungen im Bereich der analytischen Chemie dazu beitragen können, die Qualitätskontrolle von Arzneimittelwirkstoffen zu verbessern. KW - Elektronensprayionisations-Massenspektrometrie KW - Qualitätskontrolle KW - Arzneimittel KW - Reinheitsanalytik KW - evaporationsbasierte Detektoren KW - Charged Aerosol Detektion KW - Streptomycin KW - Aminosäuren KW - Aescin KW - HPLC KW - Europäsches Arzneibuch KW - Purity control KW - evaporation based detectors KW - charged aerosol detector KW - Streptomycin KW - Amino acids KW - Aescin Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-64722 ER -