TY - THES A1 - Slawig, Anne T1 - Reconstruction methods for the frequency-modulated balanced steady-state free precession MRI-sequence T1 - Rekonstruktionsmethoden für die frequenz-modulierte balanced steady-state free precession MRT-Sequenz N2 - This work considered the frequency-modulated balanced steady-state free precession (fm-bSSFP) sequence as a tool to provide banding free bSSFP MR images. The sequence was implemented and successfully applied to suppress bandings in various in vitro and in vivo examples. In combination with a radial trajectory it is a promising alternative for standard bSSFP applications. First, two specialized applications were shown to establish the benefits of the acquisition strategy in itself. In real time cardiac imaging, it was shown that the continuous shift in frequency causes a movement of the bandings across the FOV. Thus, no anatomical region is constantly impaired, and a suitable timeframe can be found to examine all important structures. Furthermore, a combination of images with different artifact positions, similar to phase-cycled acquisitions is possible. In this way, fast, banding-free imaging of the moving heart was realized. Second, acquisitions with long TR were shown. While standard bSSFP suffers from increasing incidence of bandings with higher TR values, the frequency-modulated approach provided banding free images, regardless of the TR. A huge disadvantage of fm-bSSFP, in combination with the radial trajectory, is the decrease in signal intensity. In this work a specialized reconstruction method, the multifrequency reconstruction for frequency-modulated bSSFP (Muffm), was established, which successfully compensated that phenomena. The application of Muffm to several anatomical sites, such as inner ear, legs and cardiac acquisitions, proofed the advantageous SNR of the reconstruction. Furthermore, fm-bSSFP was applied to the clinically highly relevant task of water-fat separation. Former approaches of a phase-sensitive separation procedure in combination with standard bSSFP showed promising results but failed in cases of high inhomogeneity or high field strengths where banding artifacts become a major issue. The novel approach of using the fm-bSSFP acquisition strategy with the separation approach provided robust, reliable images of high quality. Again, losses in signal intensity could be regained by Muffm, as both approaches are completely compatible. Opposed to conventional banding suppression techniques, like frequency-scouts or phase-cycling, all reconstruction methods established in this work rely on a single radial acquisition, with scan times similar to standard bSSFP scans. No prolonged measurement times occur and patient time in the scanner is kept as short as possible, improving patient comfort, susceptibility to motion or physiological noise and cost of one scan. All in all, the frequency-modulated acquisition in combination with specializes reconstruction methods, leads to a completely new quality of images with short acquisition times. N2 - In dieser Arbeit wird eine Modifikation der balanced steady-state free precession (bSSFP) Sequenz betrachtet. Die frequenzmodulierte bSSFP-Sequenz (fm-bSSFP) kann die sonst typischen Band-Artefakte in bSSFP-MR-Bildern verhindern. Die Sequenz wurde im Rahmen der Arbeit am MR-Scanner implementiert und erfolgreich in verschiedenen in-vitro- und in-vivo-Beispielen angewendet. In Kombination mit einer radialen Trajektorie erwies es sich als eine vielversprechende Alternative für alle Standard-bSSFP Anwendungen. Zuerst wurden zwei spezialisierte Anwendungen gezeigt, um die Vorteile der Akquisitionsstrategie an sich darzustellen. Am Beispiel der Echtzeit-Herzbildgebung konnte mit Hilfe der kontinuierlichen Frequenzverschiebung eine Bewegung der Bänder über das FOV erzeugt werden. Somit wird keine anatomische Region ständig von Artefakten überlagert und für jeden Bereich kann ein geeigneter Zeitrahmen gefunden werden, um die wichtigen Strukturen darzustellen und zu untersuchen. Darüber hinaus ist eine Kombination von Bildern mit verschiedenen Artefaktpositionen möglich, ähnlich zu mehreren Aufnahmen mit verschiedenen Phasenzyklen. Auf diese Weise wurde eine schnelle Bildgebung des sich bewegenden Herzens ohne Bandartefakte realisiert. Zusätzlich wurden Aufnahmen mit langen Repetitionszeiten (TR) untersucht. Während in der Standard-bSSFP die Häufigkeit von Bandartefakten mit steigendem TR-Wert zunimmt, lieferte der frequenzmodulierte Ansatz Banding-freie Bilder unabhängig vom TR. Ein großer Nachteil von fm-bSSFP in Kombination mit der radialen Trajektorie ist der Verlust von Signalintensität bei der Rekonstruktion. In dieser Arbeit wurde eine spezielle Rekonstruktionsmethode namens Muffm (mulitfrequency reconstruction for frequency-modulated bSSFP) etabliert, die diesen Verlust erfolgreich kompensieren kann. Die Anwendung von Muffm an verschiedenen anatomischen Strukturen, wie Innenohr, Bein und Herzaufnahmen, bestätigte das vorteilhafte Signal-zu-Rausch-Verhältnis, dass durch die spezielle Rekonstruktion gewonnen werden kann. Darüber hinaus wurde die fm-bSSFP auf die klinisch interessante Wasser-Fett-Trennung angewandt. Frühere Ansätze eines phasenempfindlichen Trennverfahrens in Kombination mit Standard-bSSFP zeigten vielversprechende Ergebnisse, scheiterten jedoch in Fällen hoher Inhomogenität oder hoher Feldstärken an den auftretenden Bandartefakten. Der neue Ansatz, diesen Separationsalgorithmus mit der fm-bSSFP-Akquisitionsstrategie zu verbinden, lieferte robuste, zuverlässige Bilder von hoher Qualität. Auch hier konnten entstehende Verluste in der Signalintensität durch Muffm zurückgewonnen werden, da beide Ansätze vollständig kompatibel sind. Im Gegensatz zu herkömmlichen Bandunterdrückungstechniken, wie Frequenz-Scouts oder die Aufnahme mehrerer Bilder mit verschiedenen Phasenzyklen, beruhen alle in dieser Arbeit etablierten Rekonstruktionsverfahren auf einer einzigen radialen Aufnahme. Die Messzeiten sind daher identisch zur Aufnahme einer Standard-bSSFP Messung. Das Verfahren ermöglicht eine deutliche Verkürzung der Aufenthaltsdauer im Scanner bei einer gleichzeitigen Garantie ein artefaktfreies Bild zu erhalten. Damit ist es insbesondere für Patienten von Vorteil, die unter Platzangst oder sonstigen Beschwerden leiden, die ein langes Stillliegen erschweren. Außerdem werden Bewegungsartefakte, physiologisches Rauschen und nicht zuletzt die Kosten eines Scans minimiert. Insgesamt bietet die frequenzmodulierte bSSFP Aufnahme in Kombination mit spezialisierten Rekonstruktionsverfahren neue Möglichkeiten zur schnellen Aufnahme von Bildern ohne Bandartefakte. KW - Kernspintomografie KW - Magnetic resonance imaging KW - MRI KW - MRT KW - bSSFP KW - Rekonstruktion KW - reconstruction KW - frequency modulation KW - water fat separation KW - Wasser Fett Trennung KW - balanced steady state free precession Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-162871 ER - TY - THES A1 - Basse-Lüsebrink, Thomas Christian T1 - Application of 19F MRI for in vivo detection of biological processes T1 - Anwendung der 19F MRT zur in-vivo Detektion von biologischen Prozessen N2 - This thesis focuses on various aspects and techniques of 19F magnetic resonance (MR). The first chapters provide an overview of the basic physical properties, 19F MR and MR sequences related to this work. Chapter 5 focuses on the application of 19F MR to visualize biological processes in vivo using two different animal models. The dissimilar models underlined the wide applicability of 19F MR in preclinical research. A subsection of Chapter 6 shows the application of compressed sensing (CS) to 19F turbo-spin-echo chemical shift imaging (TSE-CSI), which leads to reduced measurement time. CS, however, can only be successfully applied when a sufficient signal-to-noise ratio (SNR) is available. When the SNR is low, so-called spike artifacts occur with the CS algorithm used in the present work. However, it was shown in an additional subsection that these artifacts can be reduced using a CS-based post processing algorithm. Thus, CS might help overcome limitations with time consuming 19F CSI experiments. Chapter 7 deals with a novel technique to quantify the B+1 profile of an MR coil. It was shown that, using a specific application scheme of off resonant pulses, Bloch-Siegert (BS)-based B+1 mapping can be enabled using a Carr Purcell Meiboom Gill (CPMG)-based TSE sequence. A fast acquisition of the data necessary for B+1 mapping was thus enabled. In the future, the application of BS-CPMG-TSE B+1 mapping to improve quantification using 19F MR could therefore be possible. N2 - Diese Arbeit handelt von verschiedenen Aspekten und Techniken der 19F Magnet Resonanz Tomographie (MRT). In den ersten Kapiteln wird auf grundlegenden physikalischen Eigenschaften der MRT, die 19F MRT und MRT Sequenzen eingegangen. Kapitel 5 behandelt die Anwendung von 19F MRT zur in vivo Visualisierung von biologischen Prozessen. Dazu wurden zwei verschiedene Tiermodelle benützt. Diese stark unterschiedlichen Modelle markieren die breite Anwendungsmöglichkeit der 19F MR Bildgebung in der präklinischen Forschung. In einem Unterabschnitt des Kapitels 6 wurde gezeigt, dass Compressed Sensing (CS) zur Beschleunigung von 19F Turbo-Spin-Echo Chemical Shift Imaging (TSE-CSI) Experimenten beitragen kann. Allerdings kann CS nur erfolgreich angewendet werden, wenn ein ausreichendes Signal-Rausch-Verhältnis (SNR) vorhanden ist. Denn ist das nicht der Fall und wird der CS Algorithmus dieser Arbeit verwendet, dann entstehen sogenannte spike Artefakte. In einem weiteren Unterabschnitt wurde aber gezeigt, dass diese Artefakte mit einem CS basierten Algorithmus in der Nachbearbeitung der Daten reduziert werden. Zusammenfassend lässt sich sagen, dass CS, die Beschränkungen durch zeitaufwändigen 19F CSI Experimenten überwinden kann. Kapitel 7 handelt von einer neuartigen Technik um das B+1 Profil einer MR Spule quantitativ auszumessen. Es wurde gezeigt, dass mit einem bestimmten Anwendungsschema von offresonanten Pulsen das Bloch-Siegert (BS)-basiertes B+1 Mapping mit Hilfe einer Carr Purcell Meiboom Gill (CPMG) basierten TSE Sequenz betrieben werden kann. Somit wurde eine schnelle Aufnahme der Daten, die für das B+1 Mapping benötigt werden, erreicht. In der Zukunft könnte das BS-CPMG-TSE B+1 Mapping möglicherweise dazu beitragen, die Quantifizierung mittels 19F MRI zu verbessern. KW - Kernspintomografie KW - Fluor-19 KW - Bloch-Siegert KW - Compressed Sensig KW - 19F-MR KW - Rekonstruktion KW - NMR-Tomographie KW - NMR-Bildgebung Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-77188 ER - TY - THES A1 - Fischer, André T1 - On the Application of Compressed Sensing to Magnetic Resonance Imaging T1 - Über die Anwendung von Compressed Sensing in der Magnetresonanztomographie N2 - This thesis investigated the potential of Compressed Sensing (CS) applied to Magnetic Resonance Imaging (MRI). CS is a novel image reconstruction method that emerged from the field of information theory. The framework of CS was first published in technical reports in 2004 by Candès and Donoho. Two years later, the theory of CS was published in a conference abstract and two papers. Candès and Donoho proved that it is possible, with overwhelming probability, to reconstruct a noise-free sparse signal from incomplete frequency samples (e.g., Fourier coefficients). Hereby, it is assumed a priori that the desired signal for reconstruction is sparse. A signal is considered “sparse“ when the number of non-zero elements is significantly smaller than the number of all elements. Sparsity is the most important foundation of CS. When an ideal noise-free signal with few non-zero elements is given, it should be understandably possible to obtain the relevant information from fewer Fourier coefficients than dictated by the Nyquist-Shannon criterion. The theory of CS is based on noise-free sparse signals. As soon as noise is introduced, no exact sparsity can be specified since all elements have signal intensities that are non-zero. However, with the addition of little or moderate noise, an approximate sparsity that can be exploited using the CS framework will still be given. The ability to reconstruct noisy undersampled sparse MRI data using CS has been extensively demonstrated. Although most MR datasets are not sparse in image space, they can be efficiently sparsified by a sparsifying transform. In this thesis, the data are either sparse in the image domain, after Discrete Gradient transformation, or after subtraction of a temporally averaged dataset from the data to be reconstructed (dynamic imaging). The aim of this thesis was to identify possible applications of CS to MRI. Two different algorithms were considered for reconstructing the undersampled sparse data with the CS concept. The Nonlinear Conjugate Gradient based technique with a relaxed data consistency constraint as suggested by Lustig et al. is termed Relaxed DC method. An alternative represents the Gradient or Steepest Descent algorithm with strict data consistency and is, therefore, termed the Strict DC method. Chapter 3 presents simulations illustrating which of these two reconstruction algorithms is best suited to recover undersampled sparse MR datasets. The results lead to the decision for the Strict DC method as reconstruction technique in this thesis. After these simulations, different applications and extensions of CS are demonstrated. Chapter 4 shows how CS benefits spectroscopic 19F imaging at 7 T, allowing a significant reduction of measurement times during in vivo experiments. Furthermore, it allows highly resolved spectroscopic 3D imaging in acceptable measurement times for in vivo applications. Chapter 5 introduces an extension of the Strict DC method called CS-CC (CS on Combined Coils), which allows efficient processing of sparse undersampled multi-coil data. It takes advantage of a concept named “Joint Sparsity“, which exploits the fact that all channels of a coil array detect the same sparse object weighted with the coil sensitivity profiles. The practical use of this new algorithm is demonstrated in dynamic radial cardiac imaging. Accurate reconstructions of cardiac motion in free breathing without ECG triggering were obtained for high undersampling factors. An Iterative GRAPPA algorithm is introduced in Chapter 6 that can recover undersampled data from arbitrary (Non-Cartesian) trajectories and works solely in the Cartesian plane. This characteristic makes the proposed Iterative GRAPPA computationally more efficient than SPIRiT. Iterative GRAPPA was developed in a preceding step to combine parallel imaging with CS. Optimal parameters for Iterative GRAPPA (e.g. number of iterations, GRAPPA kernel size) were determined in phantom experiments and verified by retrospectively undersampling and reconstructing a radial cardiac cine dataset. The synergistic combination of the coil-by-coil Strict DC CS method and Iterative GRAPPA called CS-GRAPPA is presented in Chapter 7. CS-GRAPPA allows accurate reconstruction of undersampled data from even higher acceleration factors than each individual method. It is a formulation equivalent to L1-SPIRiT but computationally more efficient. Additionally, a comparison with CS-CC is given. Interestingly, exploiting joint sparsity in CS-CC is slightly more efficient than the proposed CS-GRAPPA, a hybrid of parallel imaging and CS. The last chapter of this thesis concludes the findings presented in this dissertation. Future applications expected to benefit from CS are discussed and possible synergistic combinations with other existing MR methodologies for accelerated imaging are also contemplated. N2 - In der vorliegenden Arbeit wurde untersucht, welches Potential die Anwendung von Compressed Sensing (CS) in der Magnetresonanztomographie (MRT) hat. CS ist eine neue Bildrekonstruktionsmethode aus der Informationstheorie. Das Grundgerüst für CS wurde zuerst in zwei technischen Berichten von Candès und Donoho aus dem Jahr 2004 vorgestellt. Zwei Jahre später wurde die CS-Theorie in einem Konferenzbeitrag und zwei wissenschaftlichen Artikeln veröffentlicht. Candés und Donoho zeigten, dass es mit überwältigender Wahrscheinlichkeit möglich ist, ein rauschfreies sparses Signal aus unvollständig vorliegender Frequenzinformation zu rekonstruieren. Hierfür ist eine wichtige A-priori-Annahme, dass das gewünschte Signal, welches rekonstruiert werden soll, sparse sein soll. Man spricht von sparsen Signalen, falls die Anzahl der Elemente mit Intensität größer Null signifikant kleiner als die Anzahl aller Elemente ist. Die CS-Theorie basiert auf rauschfreien, sparsen Signalen. Sobald Rauschen auftritt, kann keine exakte Sparsity mehr bestimmt werden, da alle Elemente Signalintensitäten größer Null haben. Falls jedoch nur wenig oder moderates Rauschen hinzugefügt wird ist immer noch näherungsweise eine Sparsity gegeben, die mit Hilfe von CS ausgenutzt werden kann. Die meisten MR-Datensätze sind nicht-sparse im Bildraum, können allerdings durch eine sog. Sparsifizierungstransformation effektiv sparsifiziert werden. In der vorliegenden Arbeit sind die Daten entweder im Bildraum sparse, nach einer Diskreten-Gradienten-Transformation oder nachdem bei dynamischen Daten ein zeitlich gemittelter Datensatz von den zu rekonstruierenden Daten abgezogen worden ist. Das Ziel dieser Arbeit war es, mögliche Anwendungen für CS in der MRT zu identifizieren. Zwei unterschiedliche Algorithmen wurden untersucht, um unterabgetastete sparse Daten mit dem CS-Konzept zu rekonstruieren. Eine Technik, die auf einer Nichtlinearen Methode der Konjugierten Gradienten basiert und eine gelockerte Datenkonsistenzbedingung beinhaltet, wird als Relaxed DC-Methode bezeichnet. Eine Alternative stellt der Gradienten- oder Steilster-Abstieg-Algorithmus dar, der strikte Datenkonsistenz fordert und daher als Strict-DC-Methode bezeichnet wird. Kapitel 3 zeigt Simulationen, die darlegen, dass die Strict-DC-Methode am besten zur Datenrekonstruktion in dieser Arbeit geeignet ist. Kapitel 4 zeigt, in wie fern die spektroskopische 19F-Bildgebung bei 7 T von CS profitieren kann, indem CS eine signifikante Reduktion der Messzeiten bei in vivo Experimenten erlaubt. Desweiteren ermöglicht CS hochaufgelöste spektroskopische 3D-Bildgebung in akzeptablen Messzeiten für in vivo Anwendungen. Kapitel 5 führt eine Erweiterung der Strict-DC-Methode ein, die CS-CC genannt wird, welche eine effiziente Bearbeitung von sparsen unterabgetasteten Multi-Empfänger-Datensätzen erlaubt. Hierbei profitiert CS-CC von einem Konzept namens "Joint Sparsity", welches ausnutzt, dass alle Empfangskanäle eines Spulenarrays dasselbe sparse Objekt detektieren, jeweils gewichtet mit den entsprechenden Spulensensitivitätsprofilen. Der praktische Nutzen dieses neuen Algorithmus wird an einem dynamischen radialen Herzdatensatz verdeutlicht. Akkurate Rekonstruktionen der Herzbewegung in freier Atmung und ohne EKG-Trigger konnten bei hohen Unterabtastfaktoren erreicht werden. Ein Iterativer-GRAPPA-Algorithmus, der unterabgetastete Daten beliebiger (nicht-kartesischer) Trajektorien rekonstruieren kann und ausschließlich auf einem kartesischen Gitter arbeitet, wird in Kapitel 6 vorgestellt. Das vorgeschlagene Iterative GRAPPA ist vom Rechenaufwand her effizienter als SPIRiT und wurde als ein vorhergehender Schritt zur Kombination von Paralleler Bildgebung und Compressed Sensing entwickelt. Optimale Parameter für Iteratives GRAPPA (z.B. Anzahl an Iterationen, GRAPPA-Kern-Größe) wurden in Phantom-Experimenten bestimmt und mittels Rekonstruktionen an einem retrospektiv unterabgetasteten radialen Herzdatensatz verifiziert. Die synergetische Kombination der spulenweise angewendeten Strict-DC-Methode und Iterativem GRAPPA genannt CS-GRAPPA wird in Kapitel 7 präsentiert. CS-GRAPPA erlaubt akkurate Rekonstruktionen unterabgetasteter Daten von höheren Beschleunigungsfaktoren, als mit den jeweiligen Einzelmethoden möglich gewesen wäre. Die Formulierung ist äquivalent zu L1-SPIRiT, allerdings vom Rechenaufwand effizienter. Es wurde zusätzlich ein Vergleich zu CS-CC durchgeführt. Interessanterweise hat sich gezeigt, dass das Ausnutzen der Joint Sparsity in CS-CC etwas effizienter ist als das vorgeschlagene CS-GRAPPA, das ein Hybrid aus Compressed Sensing und Paralleler Bildgebung ist. Im abschließenden Kapitel dieser Dissertation werden die Ergebnisse zusammengefasst und Schlussfolgerungen daraus gezogen. Zukünftige Anwendungen werden diskutiert, die von CS profitieren und mögliche synergetische Kombinationen mit anderen existierenden MR-Methoden für beschleunigte Bildgebung werden angesprochen. KW - NMR-Tomographie KW - Rekonstruktion KW - NMR-Bildgebung KW - Compressed Sensing KW - Unterabtastung KW - Compressed Sensing KW - Undersampling Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-72496 ER -