TY - JOUR A1 - Arhondakis, Stilianos A1 - Frousios, Kimon A1 - Iliopoulos, Costas S. A1 - Pissis, Solon P. A1 - Tischler, German A1 - Kossida, Sophia T1 - Transcriptome map of mouse isochores JF - BMC Genomics N2 - Background: The availability of fully sequenced genomes and the implementation of transcriptome technologies have increased the studies investigating the expression profiles for a variety of tissues, conditions, and species. In this study, using RNA-seq data for three distinct tissues (brain, liver, and muscle), we investigate how base composition affects mammalian gene expression, an issue of prime practical and evolutionary interest. Results: We present the transcriptome map of the mouse isochores (DNA segments with a fairly homogeneous base composition) for the three different tissues and the effects of isochores' base composition on their expression activity. Our analyses also cover the relations between the genes' expression activity and their localization in the isochore families. Conclusions: This study is the first where next-generation sequencing data are used to associate the effects of both genomic and genic compositional properties to their corresponding expression activity. Our findings confirm previous results, and further support the existence of a relationship between isochores and gene expression. This relationship corroborates that isochores are primarily a product of evolutionary adaptation rather than a simple by-product of neutral evolutionary processes. KW - Biased gene conversion KW - Human genome KW - GC-Content KW - Mammalian genomes KW - Base composition KW - Expresses genes KW - Higher rates KW - RNA-SEQ KW - Evolution KW - Rodents Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142773 VL - 12 IS - 511 ER - TY - THES A1 - Janßen, Jan Paul T1 - Capabilities of a multi-pinhole SPECT system with two stationary detectors for in vivo imaging in rodents T1 - Leistungsfähigkeit eines Multi-Pinhole SPECT-Systems mit zwei stationären Detektoren zur In-vivo-Bildgebung in Nagetiermodellen N2 - Molecular imaging of rats is of great importance for basic and translational research. As a powerful tool in nuclear medicine, SPECT can be used to visualize specific functional processes in the body, such as myocardial perfusion or bone metabolism. Typical applications in laboratory animals are imaging diagnostics or the development of new tracers for clinical use. Innovations have enabled resolutions of up to a quarter of a millimeter with acceptable sensitivity. These advances have recently led to significantly more interest in SPECT both clinically and preclinically. The objective of this thesis was to evaluate the performance of the new U-SPECT5/CT E-Class by MILabs with a dedicated ultra-high resolution multi-pinhole collimator for rats and its potential for in vivo imaging of rats. The unique features of the U-SPECT are the large stationary detectors and the new iterative reconstruction algorithm. In addition, compared to the conventional system, the "E-Class" uses only two detectors instead of three. First, the sensitivity, maximum resolution, and uniformity were determined as performance parameters. Thereafter, CNRs for different activity levels comparable to those of typical in vivo activities were examined. Finally, two example protocols were carried out for imaging with 99mTc-MIBI and 99mTc-HMDP in healthy rats to evaluate the in vivo capabilities. For this purpose, CNR calculations and an image quality assessment were performed. The focus was on image quality as a function of scan time and post-reconstruction filter across a wide range of realistically achievable in vivo conditions. Performance was reasonable compared to other systems in the literature, with a sensitivity of 567 cps/MBq, a maximum resolution of 1.20 mm, and a uniformity of 55.5%. At the lower activities, resolution in phantom studies decreased to ≥1.80 mm while maintaining good image quality. High-quality bone and myocardial perfusion SPECTs were obtained in rats with a resolution of ≥1.80 mm and ≥2.20 mm, respectively. Although limited sensitivity remains a weakness of SPECT, the U-SPECT5/CT E-Class with the UHR-RM collimator can achieve in vivo results of the highest standard despite the missing third detector. Currently, it is one of the best options for high-resolution radionuclide imaging in rats. N2 - Die molekulare Bildgebung bei Ratten hat einen hohen Stellenwert in der Grundlagenforschung und der translationale Forschung. Dabei ist SPECT ein leistungsfähiges Instrument zur Visualisierung spezifischer funktioneller Prozesse im Körper, wie z. B. der Herzmuskeldurchblutung oder des Knochenstoffwechsels. Typische Anwendungsbereiche an Labortieren sind die bildgebende Diagnostik im Rahmen von Studien oder die Entwicklung neuer Tracer für den klinischen Einsatz. Durch Innovationen wurden Auflösungen von bis zu einem Viertelmillimeter bei akzeptabler Empfindlichkeit erreichbar. Diese Fortschritte haben in letzter Zeit zu einem deutlich gestiegenen Interesse an SPECT sowohl im klinischen als auch im präklinischen Bereich geführt. Ziel dieser Arbeit war es, die Leistung des neuen U-SPECT5/CT E-Class von MILabs mit einem speziellen ultra-hochauflösenden Multi-Pinhole-Kollimator für Ratten und das Potenzial für die In-vivo-Bildgebung bei Ratten zu untersuchen. Dabei sind die Besonderheiten des U-SPECTs die großen stationären Detektoren und der neue iterative Rekonstruktionsalgorithmus. Außerdem verfügt die von uns verwendete „E-Klasse“ im Vergleich zum konventionellen System nur über zwei statt drei Detektoren. Zunächst wurden die Sensitivität, die maximale Ortsauflösung und die Homogenität als Leistungsparameter bestimmt. Anschließend wurde das Kontrast-Rausch-Verhältnis für verschiedene Aktivitätsniveaus, die mit denen typischer In-vivo-Studien vergleichbar sind, untersucht. Schließlich wurden zwei Beispielprotokolle für die Bildgebung mit 99mTc-MIBI und 99mTc-HMDP bei gesunden Ratten durchgeführt, um die In-vivo-Kapazitäten zu erfassen. Zur Bewertung wurden eine Kontrast-Rausch-Analyse und eine Bildqualitätsumfrage genutzt. Der Schwerpunkt lag dabei auf der Bildqualität in Abhängigkeit von der Scanzeit sowie dem Postrekonstruktionsfilters für ein breites Spektrum realistisch erreichbarer In-vivo-Bedingungen. Die Leistung war mit einer Sensitivität von 567 cps/MBq, einer maximalen Ortsauflösung von 1,20 mm und einer Homogenität von 55,5% mit anderen in der Literatur beschriebenen Systemen vergleichbar. Bei niedrigeren Aktivitäten verringerte sich die Auflösung in Phantomstudien auf ≥1,80 mm bei gleichbleibend guter Bildqualität. Es wurden hochqualitative Knochen- und Myokardperfusions-SPECTs mit einer Auflösung von ≥1,80 mm bzw. ≥2,20 mm bei Ratten erzielt. Obwohl die begrenzte Empfindlichkeit nach wie vor eine Schwäche der SPECT ist, kann das U-SPECT5/CT E-Class mit dem UHR-RM-Kollimator, trotz des fehlenden dritten Detektors, In-vivo-Ergebnisse auf höchstem Niveau erzielen. Es ist derzeit eine der besten Optionen für die hochauflösende Radionuklid-Bildgebung bei Ratten. KW - SPECT KW - Molekulare Bildgebung KW - Rodents KW - Image Quality KW - SPECT/CT Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-328608 ER -