TY - JOUR A1 - Heinz, Tizian A1 - Eidmann, Annette A1 - Anderson, Philip A1 - Weißenberger, Manuel A1 - Jakuscheit, Axel A1 - Rudert, Maximilian A1 - Stratos, Ioannis T1 - Trends in computer-assisted surgery for total knee arthroplasty in Germany: an analysis based on the operative procedure classification system between 2010 to 2021 JF - Journal of Clinical Medicine N2 - Alignment strategies for primary total knee arthroplasty (TKA) have changed significantly over time with a shift towards a more individualized alignment goal. At the same time, computer-assisted surgery (CAS) has gained interest for intraoperative control and accuracy in implant positioning and limb alignment. Despite the often discussed benefits and drawbacks of robotics and navigation for TKA, the routine use of these new devices on a day-to-day basis remains obscure. Therefore, nationwide hospital billing data based on the Operation Procedure Classification System (OPS) were retrieved from the Federal Statistical Office of Germany for the period from 2010 to 2021. OPS codes for primary total knee arthroplasty (OPS code: 5-822*) were further analyzed regarding the usage of computer navigation (additional OPS code: 5-988) or robotic devices (additional OPS code: 5-987). Gender and age at the time of surgery were also assessed. The results show a total of 2,226,559 primary TKAs were implanted between 2010 and 2021, of which 2,044,914 were performed conventionally (91.84% of all TKAs). A total of 170,276 TKAs were performed using navigation technique (7.65% of all TKAs) and another 11,369 TKAs were performed using robotics (0.51% of all TKAs). For the period from 2018 to 2021, a substantial increase in robot-assisted TKA (R-TKA) was observed, with an average increase rate of 84.74% per year, while the number of navigated TKAs declined (−3.67% per year). Computer-assisted surgery, and particularly robotics for TKA, are seeing growing popularity and stepwise translation into routine clinical use in Germany, with a steep increase rate of more than 80% per year since 2018. Nevertheless, the majority of TKAs are still performed using manual instrumentation, rendering conventional TKA the currently unchanged gold standard. KW - robotic KW - TKA KW - knee replacement KW - computer navigation KW - Germany Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-304879 SN - 2077-0383 VL - 12 IS - 2 ER - TY - JOUR A1 - Steinert, Andre F. A1 - Schröder, Lennart A1 - Sefrin, Lukas A1 - Janßen, Björn A1 - Arnholdt, Jörg A1 - Rudert, Maximilian T1 - The impact of total knee replacement with a customized cruciate-retaining implant design on patient-reported and functional outcomes JF - Journal of Personalized Medicine N2 - Purpose: To treat patients with tricompartimental knee osteoarthritis (OA), a customized cruciate-retaining total knee arthroplasty (CCR-TKA) system can be used, including both individualized instrumentation and implants. The objective of this monocentric cohort study was to analyze patient-reported and functional outcomes in a series of patients implanted with the second generation of this customized implant. Methods: At our arthroplasty center, we prospectively recruited a cohort of patients with tricompartmental gonarthrosis to be treated with total knee replacement (TKA) using a customized cruciate-retaining (CCR) implant design. Inclusion criteria for patients comprised the presence of intact posterior cruciate and collateral ligaments and a knee deformity that was restricted to <15° varus, valgus, or flexion contracture. Patients were assessed for their range of motion (ROM), Knee Society Score (KSS), Western Ontario and McMaster University osteoarthritis index (WOMAC), and short form (SF)-12 physical and mental scores, preoperatively, at 3 and 6 months, as well as at 1, 2, 3, and 5 years of follow-up (FU) postoperatively. Results: The average age of the patient population was 64 years (range: 40–81), the average BMI was 31 (range: 23–42), and in total, 28 female and 45 male patients were included. Implant survivorship was 97.5% (one septic loosening) at an average follow-up of 2.5 years. The KSS knee and function scores improved significantly (p < 0.001) from, respectively, 41 and 53 at the pre-operative visit, to 92 and 86, respectively, at the 5-year post-operative time point. The SF-12 Physical and Mental scores significantly (p < 0.001) improved from the pre-operative values of 28 and 50, to 50 and 53 at the 5-year FU, respectively. Patients experienced significant improvements in their overall knee range of motion, from 106° at the preoperative visit to 122°, on average, 5 years postoperatively. The total WOMAC score significantly (p < 0.001) improved from 49.1 preoperatively to 11.4 postoperatively at 5-year FU. Conclusions: Although there was no comparison to other implants within this study, patients reported high overall satisfaction and improvement in functional outcomes within the first year from surgery, which continued over the following years. These mid-term results are excellent compared with those reported in the current literature. Comparative long-term studies with this device are needed. Level of evidence 3b (individual case–control study). KW - patient-specific KW - custom-made implant KW - total knee arthroplasty KW - TKA KW - knee replacement KW - tricompartmental knee osteoarthritis KW - iTotal Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-312746 SN - 2075-4426 VL - 12 IS - 2 ER -