TY - JOUR A1 - Nordbeck, Peter A1 - Beer, Meinrad A1 - Köstler, Herbert A1 - Ladd, Mark E. A1 - Quick, Harald H. A1 - Bauer, Wolfgang R. A1 - Ritter, Oliver T1 - Cardiac catheter ablation under real-time magnetic resonance guidance JF - European Heart Journal N2 - One of the main shortcomings of interventional electrophysiology (EP) is its inability to generate sufficient soft tissue contrast for intra-procedural visualization of the myocardium and the surrounding tissue, using conventional imaging techniques. Interventional cardiovascular magnetic resonance imaging (MRI) aims at bringing about significant improvements to the complex and decisive EP interventions far beyond the capabilities of currently available supportive imaging techniques used to surmount the drawbacks of fluoroscopy, as MRI not only allows of precise three-dimensional exposure of the cardiovascular morphology, but also proves to be a promising technique exclusively suitable for direct visualization of arrhythmogenic substrate and therapeutic effects. The major challenge posed by clinical … KW - magnetic resonance Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-125638 VL - 33 IS - 15 ER - TY - JOUR A1 - Neufang, S. A1 - Akhrif, A. A1 - Herrmann, C.G. A1 - Drepper, C. A1 - Homola, G.A. A1 - Nowak, J. A1 - Waider, J. A1 - Schmitt, A.G. A1 - Lesch, K.-P. A1 - Romanos, M. T1 - Serotonergic modulation of 'waiting impulsivity' is mediated by the impulsivity phenotype in humans JF - Translational Psychiatry N2 - In rodents, the five-choice serial reaction time task (5-CSRTT) has been established as a reliable measure of waiting impulsivity being defined as the ability to regulate a response in anticipation of reinforcement. Key brain structures are the nucleus accumbens (NAcc) and prefrontal regions (for example, pre- and infralimbic cortex), which are, together with other transmitters, modulated by serotonin. In this functional magnetic resonance imaging study, we examined 103 healthy males while performing the 5-CSRTT measuring brain activation in humans by means of a paradigm that has been widely applied in rodents. Subjects were genotyped for the tryptophan hydroxylase-2 (TPH2; G-703T; rs4570625) variant, an enzyme specific for brain serotonin synthesis. We addressed neural activation patterns of waiting impulsivity and the interaction between the NAcc and the ventromedial prefrontal cortex (vmPFC) using dynamic causal modeling. Genetic influence was examined via interaction analyses between the TPH2 genotype (GG homozygotes vs T allele carriers) and the degree of impulsivity as measured by the 5-CSRTT. We found that the driving input of the vmPFC was reduced in highly impulsive T allele carriers (reflecting a reduced top-down control) in combination with an enhanced response in the NAcc after correct target processing (reflecting an augmented response to monetary reward). Taken together, we found a high overlap of our findings with reports from animal studies in regard to the underlying cognitive processes, the brain regions associated with waiting impulsivity and the neural interplay between the NAcc and vmPFC. Therefore, we conclude that the 5-CSRTT is a promising tool for translational studies. KW - Clinical Genetics Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-164418 IS - 6 ER - TY - JOUR A1 - Neubauer, Henning A1 - Wirth, Clemens A1 - Ruf, Katharina A1 - Hebestreit, Helge A1 - Beer, Meinrad T1 - Acute Muscle Trauma due to Overexercise in an Otherwise Healthy Patient with Cystic Fibrosis JF - Case Reports in Pediatrics N2 - Cystic fibrosis (CF) is one of the most common inherited diseases and is caused by mutations in the CFTR gene. Although the pulmonary and gastrointestinal manifestations of the disease remain in the focus of treatment, recent studies have shown expression of the CFTR gene product in skeletal muscle cells and observed altered intramuscular \(Ca^{2+}\) release dynamics in CFTR-deficient animal models. Physical exercise is beneficial for maintaining fitness and well-being in CF patients and constitutes one aspect of modern multimodal treatment, which has considerably increased life span and reduced morbidity. We report on a case of acute muscle trauma resulting from excessive dumbbell exercise in a young adult with cystic fibrosis and describe clinical, laboratory and imaging characteristics of acute exercise-induced muscle injury. KW - Cystic fibrosis Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-123967 VL - 2012 IS - 527989 ER - TY - JOUR A1 - Neubauer, Henning A1 - Morbach, Henner A1 - Schwarz, Tobias A1 - Wirth, Clemens A1 - Girschick, Hermann A1 - Beer, Meinrad T1 - Popliteal Cysts in Paediatric Patients: Clinical Characteristics and Imaging Features on Ultrasound and MRI N2 - Popliteal cysts, or Baker cysts, are considered rare in children and may exhibit particular features, as compared with adults. We studied data from80 paediatric patients with 55 Baker cysts, examined over a period of 7 years, and correlated clinical presentation with findings on ultrasonography and MRI. Prevalence of popliteal cysts was 57% in arthritic knees, 58% with hypermobility syndrome, and 28% without risk factors. Only one patient had a trauma history and showed an ipsilateral cyst. Mean cyst volume was 3.4 mL; cysts were larger in boys. Patients with arthritis had echogenic cysts in 53%. Cyst communication with the joint space was seen in 64% on ultrasonography and 86% on MRI. In conclusion, Baker cysts are a common finding in a clinically preselected paediatric population. Children with Baker cysts should be assessed for underlying arthritis and inherited joint hypermobility, while sporadic Baker cysts appear to be common, as well. KW - Medizin Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-68662 ER - TY - JOUR A1 - Neubauer, Henning A1 - Evangelista, Laura A1 - Morbach, Henner A1 - Girschick, Hermann A1 - Prelog, Martina A1 - Köstler, Herbert A1 - Hahn, Dietbert A1 - Beer, Meinrad T1 - Diffusion-weighted MRI of bone marrow oedema, soft tissue oedema and synovitis in paediatric patients: feasibility and initial experience N2 - Background: MRI has become the mainstay of diagnostic imaging in paediatric rheumatology for lesion detection, differential diagnosis and therapy surveillance. MR imaging of synovitis, in particular, is indispensable for early diagnosis and follow-up in arthritis patients. We used diffusion-weighted MRI (DWI) as a new imaging modality in comparison to standard MRI sequences to study bone marrow oedema, soft-tissue oedema and synovitis in paediatric patients. Methods: A total of 52 patients (mean age 11 ± 5 years) with bone marrow oedema (n = 31), soft-tissue oedema (n = 20) and synovitis (n = 15) were examined with transversal diffusion-weighted single-shot echoplanar imaging in addition to standard MR sequences (T2W TIRM, T1W pre- and post-contrast). Diffusion-weighted images were used for lesion detection and apparent diffusion coefficient (ADC, unit × 10-3 mm2/s) values were measured with ROI technique on ADC maps. Results: In 50 of 52 patients, DWI delineated the lesion of interest corresponding to pathological signal increase on standard sequences. Mean ADC was 1.60 ± 0.14 (range 1.38 - 1.99) in osseous lesions, 1.72 ± 0.31 (range 1.43 - 2.56) in soft tissue oedema and 2.82 ± 0.24 (range 2.47 - 3.18) for joint effusion (ANOVA p<0.001). No significant difference in mean ADC was seen for inflammatory vs. non-inflammatory lesions. Relative signal intensity of oedema was similar for DWI and T2W TIRM. DWI visualised synovial restricted diffusion with a mean ADC of 2.12 ± 0.45 in 12 of 15 patients with synovitis. Conclusions: Diffusion-weighted MRI reliably visualises osseous and soft tissue oedema, as compared to standard sequences. DWI of synovitis is feasible in large joints and presents a novel approach to contrast-free imaging of synovitis. Whole-body DWI for chronic non-bacterial osteomyelitis should be evaluated in future studies. KW - Medizin Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-75521 ER - TY - JOUR A1 - Ness, Thomas A1 - Bley, Thorsten A. A1 - Schmidt, Wolfgang A. A1 - Lamprecht, Peter T1 - The Diagnosis and Treatment of Giant Cell Arteritis JF - Deutsches Ärzteblatt International N2 - Background: Giant cell arteritis (GCA) is the most common systemic vasculitis in persons aged 50 and above (incidence, 3.5 per 100 000 per year). It affects cranial arteries, the aorta, and arteries elsewhere in the body, e.g., in the limbs. Methods: We selectively review the pertinent literature, including guidelines and recommendations from Germany and abroad. Results: The typical symptoms of new-onset GCA are bi-temporal headaches, jaw claudiacation, scalp tenderness, visual disturbances, systemic symptoms such as fever and weight loss, and polymyalgia. The diagnostic assessment comprises laboratory testing (erythrocyte sedimentation rate, C-reactive protein), imaging studies (duplex sonography, high-resolution magnetic resonance imaging, positron-emission tomography), and temporal artery biopsy. The standard treatment is with corticosteroids (adverse effects: diabetes mellitus, osteoporosis, cataract, arterial hypertension). A meta-analysis of three randomized controlled trials led to a recommendation for treatment with methotrexate to lower the recurrence rate and spare steroids. Patients for whom methotrexate is contraindicated or who cannot tolerate the drug can be treated with azathioprine instead. Conclusion: Giant cell arteritis, if untreated, progresses to involve the aorta and its collateral branches, leading to various complications. Late diagnosis and treatment can have serious consequences, including irreversible loss of visual function. KW - systemic vasculitides KW - arteriitis temporal arteriitis KW - erythrocyte sedimentation-rate KW - complication aortic-aneurysm KW - large-vessel vasculitis KW - c-reactive protein KW - polymyalgia-rheomatica KW - corticosteroid treatment KW - double-blind KW - ocular manifestations Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-131676 VL - 110 IS - 21 ER - TY - JOUR A1 - Müller, Sophie A1 - Köhler, Franziska A1 - Hendricks, Anne A1 - Kastner, Carolin A1 - Börner, Kevin A1 - Diers, Johannes A1 - Lock, Johan F. A1 - Petritsch, Bernhard A1 - Germer, Christoph-Thomas A1 - Wiegering, Armin T1 - Brain metastases from colorectal cancer: a systematic review of the literature and meta-analysis to establish a guideline for daily treatment JF - Cancers N2 - Colorectal cancer (CRC) is the third most common malignancy worldwide. Most patients with metastatic CRC develop liver or lung metastases, while a minority suffer from brain metastases. There is little information available regarding the presentation, treatment, and overall survival of brain metastases (BM) from CRC. This systematic review and meta-analysis includes data collected from three major databases (PubMed, Cochrane, and Embase) based on the key words “brain”, “metastas*”, “tumor”, “colorectal”, “cancer”, and “malignancy”. In total, 1318 articles were identified in the search and 86 studies matched the inclusion criteria. The incidence of BM varied between 0.1% and 11.5%. Most patients developed metastases at other sites prior to developing BM. Lung metastases and KRAS mutations were described as risk factors for additional BM. Patients with BM suffered from various symptoms, but up to 96.8% of BM patients were asymptomatic at the time of BM diagnosis. Median survival time ranged from 2 to 9.6 months, and overall survival (OS) increased up to 41.1 months in patients on a multimodal therapy regimen. Several factors including age, blood levels of carcinoembryonic antigen (CEA), multiple metastases sites, number of brain lesions, and presence of the KRAS mutation were predictors of OS. For BM diagnosis, MRI was considered to be state of the art. Treatment consisted of a combination of surgery, radiation, or systemic treatment. KW - brain metastases KW - cerebral metastases KW - BM KW - colorectal cancer KW - CRC KW - systematic review KW - meta-analysis Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-228883 SN - 2072-6694 VL - 13 IS - 4 ER - TY - THES A1 - Morche, Susanne T1 - Single-Voxel- versus Multi-Voxel-Protonen-MR-Spektroskopie bei verschiedenen intrakraniellen Läsionen T1 - Single-voxel- versus multi-voxel-proton -MR-spectroscopy in different intracranial lesions N2 - Diese Arbeit untersucht die Fragestellung ob bei der Untersuchung von gesundem Hirngewebe und pathologischen,intrakraniellen Läsionen mittels Singelvoxel- versus Multivoxel-MR-Protonen-Spektroskopie signifikant unterschiedliche Ergebnisse bestehen. Untersucht wurden Hirntumoren der WHO-Grade 2 bis 4, Metastasen und fokal-entzündliche Läsionen. Zusammenfassend ist die Unterscheidung zwischen normalem und pathologisch verändertem Hirngewebe am besten mit der Singelvoxel-Methode und Bildung der CHO/CRE-Ratio möglich. Zur Differentialdiagnose und weiteren Malignitätseinschätzung eignet sich die Bildung der CHO/NAA-Ratio mit Singelvoxel-Spektroskopie. Weiterhin ist die parallele Anwendung von Singel- und Multivoxel-Spektroskopie empfehlenswert. N2 - This study investigates the question if there is a significant difference in the analysis of healthy cerebral tissue and pathological, intracranial lesions with singlevoxel- versus multivoxel-MR-proton-spectroscopy. We tested cerebral tumors of grade 2 to 4 (WHO), metastases and focal-inflammatory lesions. In conclusion the best differentiation between normal and pathologically changed tissue was made with the singlevoxel-method and the CHO/CRE-ratio. For further differentiation of the pathological lesions and for grading of tumors the CHO/NAA- ratio with singlevoxel-spectroscopy is prefered. The use of both methods, singlevoxel- and multivoxel-spectroscopy, continues to be recommended. KW - Singlevoxel KW - Multivoxel KW - Protonen-MR-Spektroskopie KW - intrakranielle Läsionien KW - intrakranielle Tumoren KW - singlevoxel KW - multivoxel KW - proton-MR-spectroscopy KW - intracranial lesions KW - intracranial tumors Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12635 ER - TY - JOUR A1 - Montelius, Mikael A1 - Ljungberg, Maria A1 - Horn, Michael A1 - Forssell-Aronsson, Eva T1 - Tumour size measurement in a mouse model using high resolution MRI JF - BMC Medical Imaging N2 - Background Animal models are frequently used to assess new treatment methods in cancer research. MRI offers a non-invasive in vivo monitoring of tumour tissue and thus allows longitudinal measurements of treatment effects, without the need for large cohorts of animals. Tumour size is an important biomarker of the disease development, but to our knowledge, MRI based size measurements have not yet been verified for small tumours (10−2–10−1 g). The aim of this study was to assess the accuracy of MRI based tumour size measurements of small tumours on mice. Methods 2D and 3D T2-weighted RARE images of tumour bearing mice were acquired in vivo using a 7 T dedicated animal MR system. For the 3D images the acquired image resolution was varied. The images were exported to a PC workstation where the tumour mass was determined assuming a density of 1 g/cm3, using an in-house developed tool for segmentation and delineation. The resulting data were compared to the weight of the resected tumours after sacrifice of the animal using regression analysis. Results Strong correlations were demonstrated between MRI- and necropsy determined masses. In general, 3D acquisition was not a prerequisite for high accuracy. However, it was slightly more accurate than 2D when small (<0.2 g) tumours were assessed for inter- and intraobserver variation. In 3D images, the voxel sizes could be increased from 1603 μm3 to 2403 μm3 without affecting the results significantly, thus reducing acquisition time substantially. Conclusions 2D MRI was sufficient for accurate tumour size measurement, except for small tumours (<0.2 g) where 3D acquisition was necessary to reduce interobserver variation. Acquisition times between 15 and 50 minutes, depending on tumour size, were sufficient for accurate tumour volume measurement. Hence, it is possible to include further MR investigations of the tumour, such as tissue perfusion, diffusion or metabolic composition in the same MR session. KW - cancer KW - magnetic resonance KW - animal model KW - volume determination Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-124049 VL - 12 IS - 12 ER - TY - THES A1 - Moeller, Richard-Tobias T1 - Vergleich von Miktionscystourethrographie und niedrig dosierter, kontrastverstärkter Miktionsurosonographie mittels Harmonic Imaging zur Diagnostik des vesicoureteralen Refluxes bei Kindern T1 - Diagnosis of vesicoureteric reflux with low-dose contrast-enhanced harmonic ultrasound imaging N2 - Zielsetzung: Harmonic Imaging produziert Bilder mit hoher Orts- und Kontrastauflösung. Die Mikrobläschen im verwendeten Kontrastmittel werden deutlich sichtbarer. Ziel dieser Studie war es, das diagnostische Potential der kontrastverstärkten Miktionsurosonographie (MUS) mittels Harmonic Imaging bei reduzierter Kontrastmitteldosis mit der Miktionszystourethrographie (MCU) zu vergleichen. Material und Methodik: 55 Patienten (17 Jungen, 38 Mädchen; Durchschnittsalter 4 Jahre), die zur Refuxuntersuchung kamen, wurden für die Vergleichsstudie rekrutiert. Im Anschluß an einen Standard-Ultraschall des Harntraktes mit Harmonic Imaging (Sonoline Elegra, Siemens) folgte die Blasenkatheterisierung und die intravesikale Gabe des Ultraschallkontrastmittels Levovist® (300 mg/ml). Anstatt der bei MUS mit konventioneller Ultraschallmodalität verwendeten Menge – 10% des Blasenvolumens – wurde jetzt nur 5% Volumen des Kontrastmittels benutzt. Die Sonographie des Harntraktes wurde wiederholt und auch unter Miktion fortgeführt. Es schloss sich ein MCU an. Ergebnisse: Zur Evaluation standen insgesamt 114 Nieren-Ureter-Einheiten (NUE) zur Verfügung. In 29 NUE wurde mit einer oder beiden Methoden ein vesikoureteraler Reflux (VUR) diagnostiziert. In 7 NUE wurde der Reflux nur mit Hilfe der MUS, in 3 NUE nur mittels MCU diagnostiziert. Beim Vergleich der MUS mit der Referenzmethode MCU waren die diagnostischen Ergebnisse folgendermaßen: 86,4% Sensitivität, 92,4% Spezifität, 73,1% positiver Vorhersagewert und 96,6% negativer Vorhersagewert. Der Korrelationskoeffizient zwischen den beiden Methoden betrug 0,741 (p<0,001). Schlußfolgerungen: MUS mit Harmonic Imaging und halbierter Kontrastmitteldosis ist in Bezug auf Ausschluß und Diagnose eines VUR mit der MCU vergleichbar. Die Reduktion der Kontrastmittelmenge schränkt die Aussagefähigkeit der MUS nicht ein, sondern ermöglicht bei gleichen Ergebnissen eine kostengünstigere Untersuchung. N2 - Background: Harmonic US imaging has been shown to be better than conventional US for the detection and visualisation of microbubbles in contrast-enhanced voiding urosonography (VUS). Objective: To determine the diagnostic efficacy of VUS using a reduced dose of the US contrast medium in comparison to voiding cystourethrography (VCUG). Materials and methods: Fifty-five children (17 boys, 38 girls; mean age 4 years) were recruited. All patients underwent VUS by harmonic imaging followed by VCUG. The dose of the US contrast medium (Levovist®) administered intravesically was half of the recommended dose i.e. 5% of the bladder filling volume. Results: A total of 114 kidney-ureter (K-U) units were available for evaluation. Vesicoureteric reflux (VUR) was detected in 29 K-U units by one or both examination modalities. There was a 91.2% concordance rate between VUS and VCUG. VUR in seven and three K-U units were detected only by VUS and VCUG, respectively. Taking VCUG as the reference method, VUS had the following diagnostic results: 86.4% sensitivity, 92.4% specificity, positive and negative predictive values of 73.1 and 96.6%, respectively. Conclusions: Even when the dose of US contrast medium is halved, the diagnostic efficacy of harmonic VUS is comparable to VCUG. Consequently, we recommend an US contrast medium dose of 5% of the bladder filling volume for the diagnosis of VUR using contrast-enhanced harmonic VUS. KW - Kinder KW - Miktionsurosonographie KW - Ultraschallkontrastmittel KW - Harmonic Imaging KW - Miktionszystourethrographie KW - Children KW - voiding urosonography KW - contrast medium KW - Harmonic Imaging KW - voiding cystourethrography Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-16744 ER - TY - JOUR A1 - Mihatsch, Patrick W. A1 - Beissert, Matthias A1 - Pomper, Martin G. A1 - Bley, Thorsten A. A1 - Seitz, Anna K. A1 - Kübler, Hubert A1 - Buck, Andreas K. A1 - Rowe, Steven P. A1 - Serfling, Sebastian E. A1 - Hartrampf, Philipp E. A1 - Werner, Rudolf A. T1 - Changing threshold-based segmentation has no relevant impact on semi-quantification in the context of structured reporting for PSMA-PET/CT JF - Cancers N2 - Prostate-specific membrane antigen (PSMA)-directed positron emission tomography/computed tomography (PET/CT) is increasingly utilized for staging of men with prostate cancer (PC). To increase interpretive certainty, the standardized PSMA reporting and data system (RADS) has been proposed. Using PSMA-RADS, we characterized lesions in 18 patients imaged with \(^{18}\)F-PSMA-1007 PET/CT for primary staging and determined the stability of semi-quantitative parameters. Six hundred twenty-three lesions were categorized according to PSMA-RADS and manually segmented. In this context, PSMA-RADS-3A (soft-tissue) or -3B (bone) lesions are defined as being indeterminate for the presence of PC. For PMSA-RADS-4 and -5 lesions; however, PC is highly likely or almost certainly present [with further distinction based on absence (PSMA-RADS-4) or presence (PSMA-RADS-5) of correlative findings on CT]. Standardized uptake values (SUV\(_{max}\), SUV\(_{peak}\), SUV\(_{mean}\)) were recorded, and volumetric parameters [PSMA-derived tumor volume (PSMA-TV); total lesion PSMA (TL-PSMA)] were determined using different maximum intensity thresholds (MIT) (40 vs. 45 vs. 50%). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories (p ≤ 0.0322). In particular, the clinically challenging PSMA-RADS-3A lesions showed significantly lower SUV\(_{max}\) and SUV\(_{peak}\) compared to the entire PSMA-RADS-4 or -5 cohort (p < 0.0001), while for PSMA-RADS-3B this only applies when compared to the entire PSMA-RADS-5 cohort (p < 0.0001), but not to the PSMA-RADS-4 cohort (SUV\(_{max}\), p = 0.07; SUV\(_{peak}\), p = 0.08). SUV\(_{mean}\) (p = 0.30) and TL-PSMA (p = 0.16) in PSMA-RADS-5 lesions were not influenced by changing the MIT, while PSMA-TV showed significant differences when comparing 40 vs. 50% MIT (p = 0.0066), which was driven by lymph nodes (p = 0.0239), but not bone lesions (p = 0.15). SUV\(_{max}\) was significantly higher in PSMA-RADS-5 lesions compared to all other PSMA-RADS categories in \(^{18}\)F-PSMA-1007 PET/CT. As such, the latter parameter may assist the interpreting molecular imaging specialist in assigning the correct PSMA-RADS score to sites of disease, thereby increasing diagnostic certainty. In addition, changes of the MIT in PSMA-RADS-5 lesions had no significant impact on SUV\(_{mean}\) and TL-PSMA in contrast to PSMA-TV. KW - \(^{18}\)F-PSMA-1007 KW - PET/CT KW - staging KW - prostate cancer KW - standardized reporting system KW - PSMA-RADS Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-254782 SN - 2072-6694 VL - 14 IS - 2 ER - TY - THES A1 - Metschke, Michaela T1 - Die Wertigkeit der statischen und dynamischen Kernspintomographie in der Beurteilung der Schulter vor und nach Rotatorenmanschetten-Rekonstruktion N2 - Rotatorenmanschettenrupturen stellen ein häufig auftretendes Krankheitsbild in der Bevölkerungsgruppe der „Über-40-Jährigen“ dar. Die führenden Methoden in der Diagnostik der Rotatorenmanschette sind neben der klinischen Untersuchung die Kernspintomographie und die Sonographie. Die Aussagekraft beider Methoden wurde im Rahmen von Untersuchungen an präoperativen und postoperativen Patienten verglichen. Die Ergebnisse zeigten eine ausgezeichnete Sensitivität (92,9%) und Spezifität (84,2%) der Sonographie in der Erkennung von Rupturen der Rotatorenmanschette, jedoch eine Abnahme der Sensitivität (71,4%) bei Differenzierung der Läsionen in partielle und komplette Rupturen. Bei der Beurteilung der postoperativen Rotatorenmanschette blieben kleine Läsionen aufgrund der Inhomogenität des Echomusters unerkannt, größere Rerupturen wurden in allen Fällen diagnostiziert. Die Treffsicherheit der Kernspintomographie ergab eine Sensitivität von 78.6% (64,3% bei Differenzierung, s.o.), eine Spezifität von 89,5%, wobei die Untersuchungen an einem Niederfeldgerät (0,2 Tesla) mit im Vergleich zu den in der Schulterdiagnostik standardmäßig eingesetzten Kernspintomographen geringerer Auflösung und verminderter Bildqualität durchgeführt wurden. Innerhalb des ersten postoperativen Jahres erschweren Artefakte die Diagnostik der rekonstruierten Rotatorenmanschette, danach erweist sich die Kernspintomographie als ein überaus spezifisches Verfahren, mit welchem auch kleine Läsionen dargestellt werden. Des Weiteren untersucht vorliegende Arbeit anhand von Patienten- und Probandenkollektiven mit rupturierten und intakten Rotatorenmanschetten, inwieweit sich bei unterschiedlichen Ausmaßen von Rotatorenmanschettenrupturen während einer passiven oder aktiven Abduktion des Armes eine Änderung der Biomechanik feststellen läßt. Bei Untersuchungen an einem offenen Kernspintomographen wurden erstmals Verhältnisse geschaffen, welche die aktive und passive Abduktion des Armes ohne und mit Belastung möglichst realitätsnah simulierten. Die Ergebnisse der dynamischen Untersuchung zeigen, daß Rupturen des M.supraspinatus alleine zu keiner signifikanten Veränderung des Bewegungsablaufs führen. Eine zusätzliche Beteiligung des M.infraspinatus dagegen verursachte sowohl im prä- als auch im postoperativen Kollektiv eine signifikante Verringerung des Subakromialraumes, bei zusätzlicher Belastung in den jeweiligen Abduktionsstellungen zeigte sich keine weitere signifikante Translation. Dies verdeutlicht die Rolle des M.infraspinatus, dessen Funktionsdefizit ein permanentes Höhertreten des Humeruskopfes zur Folge hat. Anhand vorliegender Ergebnisse besteht kein Hinweis auf die Bestätigung der These, biomechanische Veränderungen würden zeitlich vor morphologischen Sehnenläsionen auftreten. Sowohl in der präoperativen Diagnostik als auch in der Beurteilung postoperativer Rotatorenmanschetten besitzt die Kernspintomographie einen herausragenden Stellenwert. Durch die dynamische Untersuchung konnte die oft vernachlässigte Bedeutung des M.infraspinatus hervorgehoben werden, dessen Rekonstruktion bzw. Stärkung anzustreben ist, bevor es zu einer weiteren Störung der Biomechanik kommt. Die dynamische Kernspintomographie stellt somit eine wertvolle Methode zur Untersuchung physiologischer und pathologischer Bewegungsabläufe der Schulter dar. KW - Kernspintomographie KW - MRT KW - Schulter KW - dynamisch KW - Rotatorenmanschette KW - MRI KW - shoulder KW - dynamic KW - rotator cuff Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8987 ER - TY - THES A1 - Meinhardt, Alexander T1 - MRT gesteuerte Punktionen an einem offenen 0,2T Kernspintomographen T1 - MR guided biopsy using a open 0,2T MR Imaging N2 - Es wurden insgesamt 70 Punktionen durchgeführt. Die Patienten waren zwischen 2 und 83 Jahre alt (Durchschnitt 56J.). Das Punktionssystem bestand aus einer Titan-Koaxialnadel und einer ferromagnetischen Punktionsnadel. Der Vorteil dieses Punktionssystems gegenüber einem reinen Titansystem ist die höhere Qualität der Punktionszylinder. Ein Nachteil ist, dass die Punktion außerhalb des MRT-Systems erfolgen muss. Ewa 50% der MRT-gesteuerten Punktionen entfielen auf die Leber. Knochenpunktionen wurden in 21% der Punktionen durchgeführt. Hierzu wurde ein Knochenbiopsieset mit Bohrer benutzt. Die übrigen Punktionen verteilten sich auf Thorax, den Abdominalraum ohne Leber sowie den Kopf/Hals Bereich. Die technische Erfolgsrate lag bei 96%, in drei Fällen war das gewonnene Material nicht repräsentativ, die Sensitivität bestimmte sich mit 88% bei einer Spezifität von 100%. Diese Ergebnisse liegen in der Größenordnung CT- und Ultraschallgesteuerter Punktionen. Berücksichtigt werden muss in diesem Zusammenhang die Tatsache, dass die Indikation zu MRT-gesteuerten Punktionen sich in den meisten Fällen aus der fehlenden Visualisierung der Herdbefunde im CT bzw. der komplexen anatomische Lage ableitete. Hinsichtlich der Komplikationen sind die Ergebnisse vorliegender Studie mit denen CT gesteuerter Punktionen vergleichbar, hier liegt die in der Literatur beschriebene Komplikationsrate CT gesteuerter Punktionen zwischen 1% und 3%. In dem vorliegenden Kollektiv trat lediglich eine konservativ zu beherrschende Blutung bei einer mediastinalen Punktion auf. Vergleicht man die Anzahl richtig positiver Histologien mit denen falsch negativer hinsichtlich der Dauer der Intervention, der Visualisierbarkeit der Läsionen gegeben als der Kontrastunterschied der Läsion zum Umgebungsrauschen (Kontrast/Rausch Verhältnis) sowie hinsichtlich des Kriteriums einer Doppel- oder Einfachangulierung, so zeigten sich keine signifikanten Unterschiede, was erwartungsgemäß in der geringen Anzahl falsch negativer Befunde begründet ist. Ursächlich für falsch negative Befunde waren vielmehr der geringe Durchmesser der Läsionen (4 Herdbefunde < 3 cm) sowie Punktionen im Randbereich maligner Läsionen (N=2). N2 - There were a total of 70 MR guieded biopsies. The patients were 2 to 83 years old (average 56J.). The punktionsystem consisted of a titanium koaxialneedel and a ferromagnetic needel. The advantage of this system compared to a pure titanium system is the higher quality of punktioncylinder. A disadvantage is that the puncture outside the MRT system is required. 50% of MR guidedbiopsies were in the liver. Bone point ionsBone biopsies were in 21% of the biopsies. The other biopsies distributed to the chest, abdomen without the liver and the head / neck area. The technical success rate was 96%, in three cases the resulting material was not representative, the sensitivity to certain with 88% at a specificity of 100%. These results are in the order CT and Ultrasound guieded biopsies. Consideration will be important in this context that the indication MRI-controlled biopsies in most cases from the lack of visualization of the stove or CT findings of the complex anatomical position derived. Regarding the complications are the results of this study with those of CT controlled comparable point here is described in the literature complication rate CT controlled point of between 1% and 3%. In this group came only to a conservative dominant mediastinal bleeding with a puncture. When comparing the number of positive right histology with false negative for the duration of the intervention, the visialisation lesions than the difference in the contrast of the lesion on ambient noise (contrast / noise ratio) as well as the criterion of being a double or one angulation, showed no significant differences in expected in the low number of false negative findings justified. The reason for false negative findings were rather small diameter of the lesions (4 stove findings <3 cm) and point of the periphery of malignant lesions (N = 2). KW - NMR-Tomographie KW - Punktion KW - MR guided biopsy Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-28024 ER - TY - THES A1 - Mehling, Christina Adelheid T1 - Schmerz- und Angsterleben bei Mammographie mit Fremd- und Eigenkompression T1 - pain and experience of fear during mammographiy with either patient-controlled or external controlled compression N2 - Studien der letzten Jahre haben gezeigt, dass viele Frauen aufgrund von Schmerzen bzw. aufgrund der Angst vor Schmerzen während der Mammographie diese Kebsvorsorgeuntersuchung nicht wahrnahmen. Die vorliegende Arbeit sollte folgende Fragen klären: Empfinden Frauen bei der Brustkompression während der Mammographie weniger Schmerzen wenn sie ihre Brüste selbst komprimieren, als bei Kompression durch eine MTA? Sind Frauen nach Eigenkompression zufriedener mit der gesamten Mammographie, als Frauen mit Fremdkompression, und inwieweit wirkt sich diese Zufriedenheit auf die Bereitschaft aus, wieder eine Mammographie durchführen zu lassen? Durch diese Studie sollte ein neuer Wege aufgezeigt werden, Frauen die Mammographie so angenehm wie möglich zu gestalten, um dadurch positiven Einfluss auf ihr Verhalten dieser wichtigen Vorsorgeuntersuchung gegenüber nehmen zu können. Untersucht wurden 200 Patientinnen, die der radiologischen Abteilung der Frauenklinik der Universität Würzburg zur Durchführung einer Mammographie zugewiesen worden waren. Es erfolgte die Erhebung der generellen und situativen Ängstlichkeit mittels State-Trait-Angstinventar (STAI), sowie der individuellen Kontrollüberzeugungen mittels Fragebogen zur Erhebung von Kontrollüberzeugungen zu Krankheit und Gesundheit (KKG). Nach der Mammographie beantworteten die Frauen nochmals einen Fragebogen, der ihre Zufriedenheit mit der Mammographie, sowie die dabei empfundenen Schmerzen und die Bereitschaft in zwei Jahren wieder an einem Screening durch Mammographie teilzunehmen, erfasste. Die Ergebnisse der Arbeit lassen sich folgender Maßen zusammenfassen: Es zeigte sich eine Korrelation zwischen der situativen Ängstlichkeit und den bei der Untersuchung empfundenen Schmerzen. Außerdem zeigte sich, je geringer die situationsgebundene Angst der Frauen war, desto zufriedener waren sie auch mit der Untersuchung. Es konnte kein Zusammenhang zwischen der Kontrollüberzeugung und der Zufriedenheit mit der Mammographie nachweisen werden, weder bei Fremdkompression, noch bei Eigenkompression. Auch mit dem bei der Kompression empfundenen Schmerz konnte bei keiner Kontrollüberzeugung ein Zusammenhang hergestellt werden. Bezüglich der Kompression selbst wurde festgestellt, dass Patientinnen der Experimentalgruppe bei der Kompression mehr Kraft anwandten als Patientinnen der Kontrollgruppe und damit ihre Brüste flacher komprimierten. Die Mehrheit beider Gruppen war mit der Mammographie zufrieden und gaben an, wieder an einer Mammographie in zwei Jahren teilnehmen zu wollen. Allerdings waren Frauen, die ihre Brüste selber komprimierten generell zufriedener mit ihrer Untersuchung und empfanden weniger Schmerzen während der Kompression. Der Zusammenhang, dass Frauen eine erneute Teilnahme an einer Mammographie als umso wahrscheinlicher ansahen, je zufriedener sie mit der aktuellen Untersuchung waren, konnte ebenfalls bestätigt werden. N2 - Recent studies have shown that many women did not participate in mammographic screening due to pain, or fear of pain, while breast compression. This study’s aim was to find answers to the following questions: Is mammography less painfull if the breast compression is performed by the patient herself than being perfomed by a nurse? Are women more comfortable with the mammography performing the breast compression thereselves than having the compression done by a nurse? Wow does this contentment show in being willing to have another mammography? This study wanted to show new ways to make mammography as agreeable to the women as possible to achieve a positive influence to their mental attitude towards this important screening tool. 200 patients sent to the radiological firm of the Würzburg University Gynecology to have a mammogaphy performed took part in this study. Their general and situative anxiety (State-Trait-Anxiety-Inventory) were as well messured as there individual belief in controll (Multidimensional Health Locus of Control Scale (MHLC)). After mammography a questionnaire about contentment with the mammography and about the felt pain was filled in. Also the willingness to participate in a later mammography was screened. The results were: A positive correlation between situative anxiety and pain experience while breast compression could be shown. As well as the fact, that less situative anxiety led to more contentment with mammography. No correlation was revealed in both groups between belief of control and contentment with mammogaphy. Neither was there a correlation between pain during compression and belief of control. Patients performing their breast compression theirselves pressed their breasts harder and therefor thinner than a nurse would have done. The majority of both groups was content with the mammogaphy and agreed to have done another mammography in two years. Nevertheles women who did their breast compression theirselves were more content with the mammogaphy and suffered less pain. The correlation between being content with the mammography and the willingness to have another done in two years was also confirmed. KW - Mammographie KW - Schmerz KW - Brustkompression KW - Krebsvorsorge KW - mammography KW - pain KW - cancer screening KW - mammographic compression Y1 - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-22997 ER - TY - THES A1 - Manger, Sabine T1 - Der Würzburger Schockraumalgorithmus beim polytraumatisierten Kind - eine retrospektive Analyse der Jahre 2004 bis 2009 T1 - The Würzburg polytrauma algorithm applied to severely injured children - a retrospective study of the years 2004 to 2009 N2 - Seit März 2004 ist im Zentrum für operative Medizin der Universitätsklinik Würzburg der Schockraum mit einem Somatom Sensation 16 der Firma Siemens, einem CT mit Sliding-Gantry in Betrieb. Auch schwer verletzte Kinder werden hier nach dem Würzburger Schockraumalgorithmus behandelt. Insgesamt gibt es nur wenige Daten zur Anwendung von GK-CT bei Kindern. Die DGU beschreibt im TraumaRegister die Daten von zuletzt 266 Kliniken. Nur 5,1 % dieser Daten stammen von Kindern unter 16 Jahren. Die Unterschiede zu Erwachsenen entstehen durch die geringere Erfahrung im Straßenverkehr, die kindliche Anatomie, die größere Gefährdung durch den hypovolämischen Schock und die bessere Rekonvaleszenz von Kindern. Ebenso ist die radiologische Diagnostik durch das geringere Körpervolumen und die höhere Strahlenempfindlichkeit der Kinder problematischer. Der Schockraumalgorithmus der Universitätsklinik Würzburg besteht aus der Reanimations-, CT- und Versorgungsphase. Die Indikation zur GK-CT wird nach dem Triage-Schema gestellt und ist auch bei polytraumatisierten Kindern Diagnostik der Wahl. Die Schwere der Verletzungen wird mit dem ISS bestimmt. In den Jahren 2004 bis 2009 wurden 72 Kinder mit Verdacht auf ein Polytrauma behandelt. Davon erhielten 57 (79,2%) ein GK-CT, 15 (20,1 %) erhielten eine organbezogene CT (CCT, Thorax, Abdomen). 15 (26,3 %) der 57 Kinder mit GK-CT hatten retrospektiv kein Polytrauma (ISS < 16), wobei hier von einer Overtriage auszugehen ist. Die Kinder wurden hauptsächlich im Straßenverkehr und hier als Beifahrer eines PKWs verletzt, gefolgt von den Radfahrern und Fußgängern, die von einem PKW erfasst wurden. Ein Drittel der Patienten erlitt Sturzverletzungen aus bis zu fünf Metern Höhe. Die am häufigsten verletzte Körperregion war mit 52,8 % der Kopf, gefolgt vom Thorax, den Extremitäten und 25 % Gesichtsverletzungen. Dies ist durch die ungünstigere Körper-Kopf-Relation der Kinder erklärbar. Im Vergleich zu Erwachsenen ist bei Kindern vermehrt das Gesicht, der Hals und die untere Extremität verletzt, die Wirbelsäule war weniger betroffen. 82 % der Kinder wurden maschinell beatmet, davon 65% initial und 14% in der ZNA. Es wird empfohlen, Kinder frühzeitig zu intubieren, was sich in der Intubationsrate von 82% widerspiegelt. Eine Notfalloperation wurde in 38,9 % der Fälle durchgeführt, wobei es sich hauptsächlich um Frakturrepositionen handelte, vor allem bei Kindern mit ISS < 16. Bei Kindern mit ISS ≥ 16 wurde in 8,8 % der Fälle eine Kraniotomie durchgeführt. Insgesamt wurden 62 % der Kinder operiert, wobei es sich auch bei den Operationen im Verlauf hauptsächlich um Frakturrepositionen handelte. 15 Kinder erhielten kein GK-CT als primäre Diagnostik, obwohl dies retrospektiv gemäß des Triage-Schemas indiziert gewesen wäre. Bei diesen Kindern wurden zusätzlich zum CCT selektive CTs, Röntgenaufnahmen und Abdomenultraschalluntersuchungen durchgeführt. Bei sechs Kindern wurde trotz initialer GK-CT eine therapierelevante Diagnose erst im Verlauf des Klinikaufenthalts gestellt. Dabei handelte es sich um eine Schädelbasis-, eine Orbitaboden-, eine Klavikula-, eine Talusfraktur, ein Mesenterialarterieneinriss und eine Ileumruptur. Ein Kind verstarb, weil dessen Ileumruptur in der radiologischen Diagnostik nicht detektiert wurde und die Zeit bis zur Laparotomie verzögerte. Während des Krankenhausaufenthalts wurde zur Verlaufsdokumentation die Röntgenuntersuchung, gefolgt von der Sonographie, am häufigsten angewendet. Die CT tritt hierbei in den Hintergrund, wobei die MRT häufiger durchgeführt wurde als bei der initialen Diagnostik. Die Strahlenbelastung des pädiatrischen Kollektivs ist im Kontext der schnellen Diagnoseerhebung therapierelevanter Verletzungen zu sehen. Bei der GK-CT ist mit einem durchschnittlichen DLP von 2268 mGy•cm, bei der CCT von 956 mGy•cm zu rechnen. Bei den Röntgenuntersuchungen ein DFP von 4 cGy•cm2 bei Thoraxröntgenuntersuchungen und 11 cGy•cm2 bei anderen Röntgenuntersuchungen. Zur korrekten Einordnung der Strahlendosis sind genauere Richtwerte für Kinder und genauere Protokolle nötig. Die GK-CT ist Methode der Wahl bei polytraumatisierten Kindern und wird nur in seltenen Fällen von der FAST oder der Röntgenuntersuchung ersetzt. Trotz der GK-CT können nicht alle therapierelevanten Diagnosen gestellt werden. Insgesamt verbrachten die Kinder durchschnittlich 17 Tage im Krankenhaus und sieben Tage auf der Intensivstation. 77,8 % konnten danach nach Hause entlassen werden, sieben Kinder mussten nach dem Krankenhausaufenthalt in eine Rehabilitationsklinik verlegt werden. Die Letalität der Kinder ist mit 10,5% (n=6) im Vergleich zu den Erwachsenen mit 13,5 % und anderen Studien mit einer pädiatrischen Letalität mit durchschnittlich 18 % geringer. Vier Kinder verstarben an schwerem SHT, ein Kind in Folge seines schweren Thoraxtraumas und ein Kind entwickelte eine Sepsis in Folge einer in der radiologischen Diagnostik nicht detektierbaren Ileumruptur. Die radiologische Diagnostik des kindlichen Polytraumas hat sich durch das MSCT in den letzten Jahren stark gewandelt. Die geringe Letalität unseres Patientenkollektivs ist ein deutlicher Hinweis auf die Effizienz des Würzburger Schockraumalgorithmus auch beim pädiatrischen Polytrauma. N2 - The Würzburg polytrauma algorithm applied to severely injured children - a retrospective study of the years 2004 to 2009 KW - Polytrauma KW - Schockraumbehandlung KW - pädiatrisches Polytrauma KW - radiologische Diagnostik im Schockraum KW - Ganzkörpercomputertomographie bei Kindern KW - Whole-body-computertomography KW - Severely injuried child Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-94293 ER - TY - THES A1 - Maier, Stefanie T1 - Flußgeschwindigkeitsmessungen an Schlauchmodellen : Einfluß eines Echosignalverstärkers auf die Meßergebnisse von drei verschiedenen Farbduplexgeräten N2 - Die farbkodierte Duplexsonographie (FKDS) hat sich als nichtinvasive Methode zur Darstellung des Blutflußes innerhalb von Gefäßen sowie von Gefäßveränderungen etabliert. Während gute Ergebnisse der Farbduplexsonographie in großen Gefäßen über 0,51 mm vorliegen, konnte in einer Modellstudie an kleinen Gefäßen unter 0,51 mm festgestellt werden, daß die FKDS in kleineren Gefäßen systematisch zu niedrig mißt. Mit Hilfe des geprüften Echosignalverstärkers kann dieser systematische Fehler nicht behoben werden. Der Einsatz des Echosignalverstärkers bewirkt grundsätzlich nur eine geringe Zunahme der gemessenen Flußgeschwindigkeit. Dies ist unabhängig von dem Gerätetyp und der Schlauchgröße. Der maximale Effekt wird nach 10 bis 60 Sekunden erreicht. Die Messungen der drei Farbdopplergeräte QAD 1 (Firma Philips/Quantum), SONOLINE Elegra (Firma Siemens) und HDI 3000 (Firma Philips/ATL) unterscheiden sich in ihrer Auswertung signifikant. Die Ursache der großen Messdifferenzen unter den Geräte ist endgültig nicht geklärt. Wahrscheinlich liegt die Ursache in der internen Signalverarbeitung der Farbduplexgeräte. KW - Flußgeschwindigkeit KW - Echosignalverstärker KW - Farbduplexgeräte Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-8852 ER - TY - THES A1 - Machann, Wolfram T1 - MRT nach Myokardinfarkt - Wandfunktionsanalyse und metabolische Bildgebung T1 - MRI after myocardial infarction - Wall motion analysis and metabolic imaging N2 - Die kardiale MRT konnte in dieser Arbeit für die Infarktdiagnostik und Therapiekontrolle erfolgreich eingesetzt werden. Auf Grund einer Vielzahl von Sequenztechniken, dem Vorteil der Nichtinvasivität und dem Fehlen von ionisierenden Strahlen hat sich die MRT zu einem wichtigen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen entwickelt. N2 - Cardiac MRI could be used successfully for the diagnosis of myocardial infarction and for therapy control. Due to a multiplicity of MRI sequences, the advantage of a non invasive approach and the lack of ionising rays, MRI developed to an important diagnostic tool for the determination of parameters in cardiac diseases KW - NMR-Tomographie KW - Herz KW - Natrium KW - MRI KW - cardiac KW - sodium Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-28457 ER - TY - JOUR A1 - Luetkens, Karsten Sebastian A1 - Grunz, Jan-Peter A1 - Kunz, Andreas Steven A1 - Huflage, Henner A1 - Weißenberger, Manuel A1 - Hartung, Viktor A1 - Patzer, Theresa Sophie A1 - Gruschwitz, Philipp A1 - Ergün, Süleyman A1 - Bley, Thorsten Alexander A1 - Feldle, Philipp T1 - Ultra-high-resolution photon-counting detector CT arthrography of the ankle: a feasibility study JF - Diagnostics N2 - This study was designed to investigate the image quality of ultra-high-resolution ankle arthrography employing a photon-counting detector CT. Bilateral arthrograms were acquired in four cadaveric specimens with full-dose (10 mGy) and low-dose (3 mGy) scan protocols. Three convolution kernels with different spatial frequencies were utilized for image reconstruction (ρ\(_{50}\); Br98: 39.0, Br84: 22.6, Br76: 16.5 lp/cm). Seven radiologists subjectively assessed the image quality regarding the depiction of bone, hyaline cartilage, and ligaments. An additional quantitative assessment comprised the measurement of noise and the computation of contrast-to-noise ratios (CNR). While an optimal depiction of bone tissue was achieved with the ultra-sharp Br98 kernel (S ≤ 0.043), the visualization of cartilage improved with lower modulation transfer functions at each dose level (p ≤ 0.014). The interrater reliability ranged from good to excellent for all assessed tissues (intraclass correlation coefficient ≥ 0.805). The noise levels in subcutaneous fat decreased with reduced spatial frequency (p < 0.001). Notably, the low-dose Br76 matched the CNR of the full-dose Br84 (p 0.999) and superseded Br98 (p < 0.001) in all tissues. Based on the reported results, a photon-counting detector CT arthrography of the ankle with an ultra-high-resolution collimation offers stellar image quality and tissue assessability, improving the evaluation of miniscule anatomical structures. While bone depiction was superior in combination with an ultra-sharp convolution kernel, soft tissue evaluation benefited from employing a lower spatial frequency. KW - photon-counting CT KW - arthrography KW - ankle KW - cartilage KW - radiation dosage Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-362622 SN - 2075-4418 VL - 13 IS - 13 ER - TY - JOUR A1 - Luetkens, Karsten Sebastian A1 - Ergün, Süleyman A1 - Huflage, Henner A1 - Kunz, Andreas Steven A1 - Gietzen, Carsten Herbert A1 - Conrads, Nora A1 - Pennig, Lenhard A1 - Goertz, Lukas A1 - Bley, Thorsten Alexander A1 - Gassenmaier, Tobias A1 - Grunz, Jan-Peter T1 - Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system JF - Scientific Reports N2 - Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current–time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70%) and mULD (0/3/5%). Superior depiction of cortical and cancellous bone was achieved in FD\(_{Ur77}\) and LD\(_{Ur77}\) examinations (p < 0.001) with LD\(_{Ur77}\) scans also providing favorable bone visualization compared to FD\(_{Br69}\) and FD\(_{Br62}\) (p < 0.001). Fleiss’ kappa was 0.618 (0.594–0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture. KW - medical research KW - preclinical research Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-270429 VL - 11 IS - 1 ER - TY - THES A1 - Lucius, Leonie Johanna T1 - Die endovaskuläre Therapie der malignen unteren Einflussstauung mit dem Sinus-XL® Stent T1 - Endovascular therapy of malignant obstruction of the inferior vena cava with the Sinus-XL® stent system N2 - Die interventionelle Radiologie hat sich in den letzten Jahrzehnten zunehmend auf palliativmedizinische sowie onkologische Bereiche ausgeweitet und kann durch minimal-invasive Therapieoptionen gerade in vulnerablen Patientenkollektiven attraktive Behandlungsmöglichkeiten zur Verfügung stellen. Die tumorbedingte untere Einflussstauung ist ein seltenes Krankheitsbild und stellt eine schwere symptomatische Komplikation einer malignen Grunderkrankung dar. Dabei kommt es im Rahmen dieser Grunderkrankung durch die Primärtumormasse oder Metastasen zu extrinsischer Kompression der Vena cava inferior (VCI), Gefäßinvasion oder Thrombusbildung. Ziel der Dissertationsarbeit ist es, den technischen und klinischen Erfolg der Sinus-XL ® Stentimplantation in die Vena cava inferior bei einer tumorbedingten unteren Einflussstauung zu untersuchen. Als technischer Erfolg wurde dabei die problemlose Stentimplantation mit anschließender Aufhebung der VCI-Stenose/Okklusion und Revaskularisation der VCI definiert. Bezüglich des klinischen Erfolges wurde der Frage nachgegangen, inwieweit die Stentimplantation die typischen Symptome einer unteren Einflussstauung (Ödeme der unteren Extremität, Aszites und Anasarka) lindern und bestenfalls eliminieren kann. In der vorliegenden Arbeit sind dazu retrospektiv die Daten von insgesamt 21 Patienten (11 Frauen, 10 Männer) mit einem medianen Alter von 61 Jahren (19-92 Jahre), die zwischen Oktober 2010 und Januar 2021 aufgrund einer tumorbedingten unteren Einflussstauung mit einem Sinus-XL ® Stent endovaskulär versorgt wurden, ausgewertet worden. Zur Quantifizierung der klinischen Symptomatik wurde für das jeweilige Symptom ein Scoring-System entwickelt bzw. modifiziert. Der technische Erfolg belief sich auf 100% (21/21). Postinterventionell konnte zudem eine signifikante Reduktion des transstenotischen Druckgradienten (p = 0,008) und eine signifikante Aufweitung des Stenosendiameters (p < 0,001) erreicht werden. Die primäre und primär-assistierte Stentoffenheit betrug 92,9 % (13/14) und 100% (14/14), die anatomische Stentoffenheit (< 50% Restenose) belief sich auf 53,3 % (8/15). Die Reinterventionsrate lag bei 4,8 % (1/21). Schwerwiegende Komplikationen traten nicht auf. Der klinische Erfolg bezüglich der Ödeme der unteren Extremität belief sich auf 82,4 % (14/17), 93,8 % (15/16) sowie auf 85,7 % (18/21) und zeigte in allen betrachteten Zeitintervallen eine signifikante Scorewertreduktion (p < 0,001). Das klinische Outcome bezüglich der Ödeme war bei kürzeren Stenosen/Obstruktionen signifikant besser (p = 0,025). Bezüglich einer intrahepatischen Segmentbeteiligung, der transstenotischen Druckgradienten, der absoluten Gradientenreduktion sowie der Überlebenszeit nach der Intervention zeigten sich hingegen keine als klinisch relevant einzustufende Ergebnisse. Ein eindeutiger Effekt der Intervention auf die Symptome Anasarka und Aszites konnte nicht nachgewiesen werden. Diesbezüglich zeigten sich klinische Erfolgsraten von 42,9 % (6/14) und 5,3 % (1/19). Im postinterventionellen Verlauf konnten außerdem signifikante Reduktionen der präinterventionellen Harnstoffwerte sowie des Körpergewichtes der Patienten verzeichnet werden. Zusammenfassend zeigt die vorliegende Arbeit, dass die Sinus-XL ® Stentimplantation geeignet ist, eine tumorbedingte Vena cava inferior-Stenose/Obstruktion aufzuheben und eine Revaskularisation der VCI zu erreichen. Die klinischen Symptome einer unteren Einflussstauung – insbesondere bezogen auf die Ödeme der unteren Extremität und mit Einschränkungen bezogen auf die Symptome Aszites und Anasarka – können ebenfalls durch die Stentimplantation gelindert und teilweise sogar langanhaltend eliminiert werden. Die Sinus-XL ® Stentimplantation sollte daher stets als Therapieoption bei tumorbedingten unteren Einflussstauungen in Erwägung gezogen werden. Nicht zuletzt stellt die Stentimplantation auch eine sichere und komplikationsarme Intervention dar. Weitere Studien, bestenfalls multizentrische Studien, sind jedoch notwendig, um die dargestellten Ergebnisse weiter zu untermauern. N2 - In recent decades interventional radiology has increasingly expanded into palliative as well as oncologic settings and can provide attractive treatment options through minimal-invasive therapies, especially in vulnerable patient populations. Malignant obstruction of the inferior vena cava (IVC) is a rare clinical condition and represents a severe symptomatic complication of an underlying malignant disease. Extrinsic compression of the inferior vena cava, vascular invasion or thrombus formation occur as part of the underlying disease. The aim of this work is to investigate the technical and clinical success of Sinus-XL ® stent implantation into the inferior vena cava in case of malignant obstruction of the inferior vena cava. Technical success was defined as the successful stent implantation with subsequent resolution of the stenosis/occlusion and revascularization of the IVC. Regarding clinical success, the question was addressed to what extent stent implantation can alleviate and, at best, eliminate the typical symptoms of malignant IVC obstruction (lower extremity edema, ascites and anasarca). Therefore data from a total of 21 patients (11 women, 10 men) with a median age of 61 years (19-92 years) who underwent endovascular treatment with a Sinus-XL ® stent for malignant IVC obstruction between October 2010 and January 2021 was retrospectively analyzed. In order to quantify the extent of the clinical symptoms a scoring system was developed or modified for each symptom. The technical success was 100% (21/21). After the intervention a significant reduction of the transstenotic pressure gradient (p = 0.008) and a significant widening of the stenotic diameter (p < 0.001) were achieved. Primary and primary-assisted stent patency were 92.9% (13/14) and 100% (14/14), anatomic stent patency (< 50% restenosis) was 53.3% (8/15). The reintervention rate was 4.8% (1/21). No major complications occurred. The clinical outcome regarding lower extremity edema was 82.4% (14/17), 93.8% (15/16), and 85.7% (18/21), showing a significant score reduction in all time intervals considered (p < 0.001). Clinical outcome regarding edema was significantly better with shorter stenosis/obstruction (p = 0.025). In contrast, with regard to intrahepatic segment involvement, transstenotic pressure gradients, absolute gradient reduction, and survival time after the intervention, there were no results that could be classified as clinically relevant. A clear effect of the intervention on the symptoms of anasarca and ascites could not be demonstrated. In this regard, clinical success rates of 42.9% (6/14) and 5.3% (1/19) were shown. In the post-interventional course, significant reductions of the pre-interventional urea levels as well as of the patients´ body weight could also be recorded. In conclusion, the present work shows that Sinus-XL ® stent implantation is suitable to resolve malignant IVC obstruction and to achieve revascularization of the IVC. The clinical symptoms - especially related to lower extremity edema and with limitations related to the symptoms of ascites and anasarca - can be alleviated by stent implantation and in some cases even eliminated. Sinus-XL ® stent implantation should therefore always be considered as a therapeutic option for malignant IVC obstruction. Last but not least, stent implantation also represents a safe and low-complication intervention. However, further studies, at best multicenter studies, are necessary to further substantiate the presented results. KW - Vena cava inferior KW - Stent KW - Interventionsradiologie KW - Onkologie KW - maligne untere Einflussstauung KW - endovaskuläre Therapie Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-326691 ER - TY - THES A1 - Lubina, Nora T1 - 3,0 Tesla HR-MR-Mammographie bei pathologischer Mamillensekretion T1 - 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge N2 - Da die häufigste Ursache der pathologischen Mamillensekretion ein benigner Prozess ist, sollte die Diagnostik mittels nicht invasiver Verfahren im Vordergrund stehen. Dabei stellt die Kernspintomographie eine wichtige Modalität dar, vor allem wenn die Mammographie und die Mammasonographie keine Befunde zeigen. In dieser Studie wurden Patientinnen mit pathologischer Mamillensekretion mittels MR-Mammographie bei 3,0 Tesla und anschließend mittels Galaktographie untersucht. Von Juli 2009 bis Juni 2012 wurden 50 Patientinnen in die Studie eingeschlossen, die eine pathologische Mamillensekretion zeigten und einer MR-Mammographie bei 3,0 Tesla zustimmten. Bei allen Studienteilnehmerinnen waren sowohl die Mammographie als auch die Mammasonographie negativ oder zeigten einen unklaren Befund. Weitere Einschlusskriterien waren im Normbereich liegende Nieren- und Prolaktinwerte. Sechs Patientinnen zeigten einen beidseitigen Ausfluss. Hier wurden beide Brüste in die Studie eingeschlossen, so dass insgesamt 56 Fälle mit einem Durchschnittsalter von 51,2 Jahren (Standardabweichung ± 12,8 Jahre, Median 52,5 Jahre) betrachtet wurden. Ältere Patientinnen zeigten dabei häufiger maligne Ursachen als jüngere, ohne Nachweis eines signifikanten Unterschieds (p = 0,272). Bei der klinischen Untersuchung war in 44,6% (25/56) ein nicht-blutiger und in 55,4% (31/56) ein blutiger Ausfluss erkennbar. Die Inzidenz der Malignität in der Gruppe der blutigen Sekretion war höher (19,4% vs. 8,0%), jedoch nicht signifikant (p = 0,23). In der Literatur wird davon berichtet, dass bei blutigem Ausfluss das Risiko für ein Mammakarzinom höher ist. Es wird aber auch darauf hingewiesen, dass bei einem nicht-blutigen Ausfluss ein Malignom keinesfalls ausgeschlossen werden kann. Die häufigste Ursache der pathologischen Mamillensekretion war, wie auch in der Literatur berichtet wird, mit 39,4% ein Papillom. Insgesamt wurde in 14,8% ein Malignom nachgewiesen. Dies ist etwas höher als die vergleichbaren Angaben von 2% - 10% in der Literatur. Es bestand ein signifikanter, direkt proportionaler Zusammenhang zwischen Größe in der MR-Mammographie und Malignität (p = 0,019). Ein Phänomen, das Liberman et al. ebenfalls beschrieben. Sowohl sie als auch Langer et al. empfehlen somit bei Läsionen, die kleiner als 5 mm sind, aufgrund der geringen Malignomrate auf eine Biopsie zu verzichten. Auch in der vorliegenden Studie waren alle Läsionen < 5 mm benigne. Zwischen der MR-mammographisch geschätzten Größe und der histopathologisch ermittelten Größe konnte eine signifikant hohe Korrelation gezeigt werden (Korrelationskoeffizient nach Pearson 0,095, p < 0,0001). Dabei wurden die Befunde in der Kernspintomographie tendenziell größer dargestellt. Die gleiche Erfahrung machten auch Son et al. und Schouten van der Velden et al.. Die Ergebnisse der MR-Mammographie wurden mit der danach durchgeführten Galaktographie verglichen. Ein wichtiger Nachteil der Galaktographie zeigte sich in der eingeschränkten Durchführbarkeit. In 23,3% konnte diese nicht erfolgreich beendet werden. In der Literatur wird von ähnlichen Prozentsätzen gesprochen. Zusätzlich erzielten wir im Vergleich zur MR-Mammographie sowohl eine geringere Sensitivität (86% vs. 96%) als auch eine niedrigere Spezifität (33% vs. 70%) für die Galaktographie, was sicherlich auch die Schwierigkeit der Unterscheidung zwischen benignen und malignen Befunden bei einer Galaktographie widerspiegelt. Morrogh et al. verglichen die Galaktographie mit der MR-Mammographie bei 1,5 Tesla ebenfalls bei Patientinnen mit pathologischer Mamillensekretion und negativer Standarddiagnostik. Die von ihnen berichtete Sensitivität von 83% für die MR-Mammographie ist vergleichbar mit der der vorliegenden Studie (75%). Bei 1,5 Tesla erreichten sie allerdings nur eine Spezifität von 62%, die geringer ist als die von uns errechnete Spezifität von 88%. Auch andere Studien referieren eine höhere Spezifität bei höherer Feldstärke. Um dies allerdings aussagekräftig zu zeigen, muss eine intraindividuelle Studie bei 1,5 Tesla und 3,0 Tesla durchgeführt werden. Zusammenfassend kann man jedoch sagen, dass die Galaktographie durch die nicht invasive, strahlungsfreie MR-Mammographie bei der Untersuchung von Patientinnen mit pathologischer Mamillensekretion ersetzt werden sollte, insbesondere wenn die Standarddiagnostik keine auffälligen Befunde liefern konnte. N2 - Objectives To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. Methods We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound by using 3.0 Tesla breast MRI utilizing a dedicated 16 channel breast coil and compared the results with galactography. Histopathological diagnoses and follow ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Results Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7% vs. 85.7% and 69.7% vs. 33.3%, respectively. For the supposed concrete pathology based on the findings in MRI, the specificity was 67.6% and the sensitivity 77.3% (PPV 60.7%, NPV 82.1%). 8 malignant lesions were detected (14.8%). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson’s correlation coefficient 0.95, p < 0.0001). Conclusions MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the work-up of nipple discharge in patients with inconspicuous mammography and ultrasound. KW - NMR-Mammographie KW - Mamma KW - 3,0 Tesla KW - Mamillensekretion KW - Galaktographie KW - magnetic resonance imaging KW - breast KW - 3.0 Tesla KW - nipple discharge KW - galaoctography Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-106180 ER - TY - JOUR A1 - Lohr, David A1 - Terekhov, Maxim A1 - Weng, Andreas Max A1 - Schroeder, Anja A1 - Walles, Heike A1 - Schreiber, Laura Maria T1 - Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T JF - PLoS ONE N2 - Purpose of this work was to assess feasibility of cardiac diffusion tensor imaging (cDTI) at 7 T in a set of healthy, unfixed, porcine hearts using various parallel imaging acceleration factors and to compare SNR and derived cDTI metrics to a reference measured at 3 T. Magnetic resonance imaging was performed on 7T and 3T whole body systems using a spin echo diffusion encoding sequence with echo planar imaging readout. Five reference (b = 0 s/mm\(^2\)) images and 30 diffusion directions (b = 700 s/mm\(^2\)) were acquired at both 7 T and 3 T using a GRAPPA acceleration factor R = 1. Scans at 7 T were repeated using R = 2, R = 3, and R = 4. SNR evaluation was based on 30 reference (b = 0 s/mm\(^2\)) images of 30 slices of the left ventricle and cardiac DTI metrics were compared within AHA segmentation. The number of hearts scanned at 7 T and 3 T was n = 11. No statistically significant differences were found for evaluated helix angle, secondary eigenvector angle, fractional anisotropy and apparent diffusion coefficient at the different field strengths, given sufficiently high SNR and geometrically undistorted images. R≥3 was needed to reduce susceptibility induced geometric distortions to an acceptable amount. On average SNR in myocardium of the left ventricle was increased from 29±3 to 44±6 in the reference image (b = 0 s/mm\(^2\)) when switching from 3 T to 7 T. Our study demonstrates that high resolution, ex vivo cDTI is feasible at 7 T using commercial hardware. KW - Heart KW - Diffusion tensor imaging KW - Eigenvectors KW - Cardiac ventricles KW - Tractography KW - Magnetic resonance imaging KW - Data acquisition KW - Swine Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-201376 VL - 14 IS - 3 ER - TY - JOUR A1 - Liu, Dan A1 - Hu, Kai A1 - Niemann, Markus A1 - Herrmann, Sebastian A1 - Cikes, Maja A1 - Störk, Stefan A1 - Beer, Meinrad A1 - Gaudron, Philipp Daniel A1 - Morbach, Caroline A1 - Knop, Stefan A1 - Geissinger, Eva A1 - Ertl, Georg A1 - Bijnens, Bart A1 - Weidemann, Frank T1 - Impact of Regional Left Ventricular Function on Outcome for Patients with AL Amyloidosis JF - PLoS ONE N2 - Objectives The aim of this study was to explore the left ventricular (LV) deformation changes and the potential impact of deformation on outcome in patients with proven light-chain (AL) amyloidosis and LV hypertrophy. Background Cardiac involvement in AL amyloidosis patients is associated with poor outcome. Detecting regional cardiac function by advanced non-invasive techniques might be favorable for predicting outcome. Methods LV longitudinal, circumferential and radial peak systolic strains (Ssys) were assessed by speckle tracking imaging (STI) in 44 biopsy-proven systemic AL amyloidosis patients with LV hypertrophy (CA) and in 30 normal controls. Patients were divided into compensated (n = 18) and decompensated (n = 26) group based on clinical assessment and followed-up for a median period of 345 days. Results Ejection fraction (EF) was preserved while longitudinal Ssys (LSsys) was significantly reduced in both compensated and decompensated groups. Survival was significantly reduced in decompensated group (35% vs. compensated 78%, P = 0.001). LSsys were similar in apical segments and significantly reduced in basal segments between two patient groups. LSsys at mid-segments were significantly reduced in all LV walls of decompensated group. Patients were further divided into 4 subgroups according to the presence or absence of reduced LSsys in no (normal), only basal (mild), basal and mid (intermediate) and all segments of the septum (severe). This staging revealed continuously worse prognosis in proportion to increasing number of segments with reduced LSsys (mortality: normal 14%, mild 27%, intermediate 67%, and severe 64%). Mid-septum LSsys<11% suggested a 4.8-fold mortality risk than mid-septum LSsys≥11%. Multivariate regression analysis showed NYHA class and mid-septum LSsys were independent predictors for survival. Conclusions Reduced deformation at mid-septum is associated with worse prognosis in systemic amyloidosis patients with LV hypertrophy. KW - regression analysis KW - ejection fraction KW - echocardiography KW - cardiac transplantation KW - deformation KW - amyloidosis KW - prognosis KW - stem cell transplantation Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-130293 VL - 8 IS - 3 ER - TY - THES A1 - Lipp, Michael T1 - Vorstellung einer Prä-Bolustechnik zur Bestimmung der myokardialen Perfusion mit Hilfe der Magnetresonanztomographie sowie Vergleich von myokardialen Perfusionswerten in herzgesunden Probanden beim Einsatz unterschiedlicher MR-Kontrastmittel und Untersuchungsprotokolle T1 - Introduction of a pre-bolus technique to determine human myocardial perfusion with magnetic resonance imaging and comparison of perfusion values of healthy volunteers by using different mri contrast agents and different research settings N2 - Die Kombination einer geringen Kontrastmittelmenge (Prä-Bolus) zur Ermittlung und Konstruktion einer Arteriellen Input Funktion, kombiniert mit der Verabreichung eines höher dosierten Kontrastmittel-Bolus zur Darstellung der morphologischen Herzstrukturen bewirkt eine deutliche Verbesserung des Kontrast-Rausch-Verhältnisses bei gleichzeitigem Vermeiden von Sättigungseffekten. Durch die Möglichkeit der Anwendung dieser Technik in Multi Slice MR Imaging Sequenzen empfiehlt sich die neue Prä-Bolustechnik für weitere, zukünftige klinische Studien auf diesem Gebiet. N2 - The combination of a low dose mri contrast agent (pre-bolus) for the determination and construction of the arterial input function with a second high dose contrast agent bolus results in a significant better contrast to noise ratio und simultaneously avoids known saturation effects in magnetic resonance perfusion imaging of the human heart. The possibility to use this new pre-bolus technique in multi slice mr imaging sequences seems to be a promising tool for future cardiac diagnostics in mri. KW - Myokardiale Perfusion KW - Prä-Bolus Untersuchung KW - MRT KW - Myokardiale Perfusion KW - Prä-Bolus Untersuchung KW - MRT KW - myocardial perfusion KW - pre-bolus technique KW - mri Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-38641 ER - TY - JOUR A1 - Linz, Christian A1 - Brands, Roman C. A1 - Kertels, Olivia A1 - Dierks, Alexander A1 - Brumberg, Joachim A1 - Gerhard-Hartmann, Elena A1 - Hartmann, Stefan A1 - Schirbel, Andreas A1 - Serfling, Sebastian A1 - Zhi, Yingjun A1 - Buck, Andreas K. A1 - Kübler, Alexander A1 - Hohm, Julian A1 - Lapa, Constantin A1 - Kircher, Malte T1 - Targeting fibroblast activation protein in newly diagnosed squamous cell carcinoma of the oral cavity – initial experience and comparison to [\(^{18}\)F]FDG PET/CT and MRI JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose While [\(^{18}\)F]-fluorodeoxyglucose ([\(^{18}\)F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT. Methods Ten consecutive, treatment-naïve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [\(^{18}\)F]FDG and [\(^{68}\)Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUV\(_{max}\)) and peak (SUV\(_{peak}\) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference. Results [\(^{18}\)F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([\(^{18}\)F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3% vs. 87.5%; P = 0.32) and specificity (93.3% vs. 81.3%; P = 0.16) to [\(^{18}\)F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples. Conclusion FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted. KW - molecular imaging KW - fibroblast activation protein KW - head and neck cancer KW - PET Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-307246 SN - 1619-7070 SN - 1619-7089 VL - 48 IS - 12 ER - TY - THES A1 - Linsenmann, Thomas T1 - Das neonatale Kraniopharyngeom - Ein kasuistischer Beitrag und Literaturübersicht T1 - Neonatal Craniopharyngioma - A case report and review of the literature N2 - Das Kraniopharyngeom ist eine dysontogenetische Mittellinienfehlbildung mit raumforderndem Charakter. Die Ätiopathogenese ist noch ungeklärt. Bildgebende Verfahren (Sonographie, MRT) ermöglichen bereits pränatal eine Diagnostik. Das neonatale Kraniopharyngeom ist sehr selten. Bisher finden sich in der Literatur nur wenige Fallberichte von denen operative Verläufe sowie klinische Langzeitverläufe bekannt sind. Es bleibt eine Kontroverse hinsichtlich Radikalität und Zeitpunkt der Operation, nicht aber dahingehend, dass die operationsmikroskopische Versorgung die Therapie der Wahl des neonatalen Kraniopharyngeoms darstellt. Die Nähe zur hypophysären-hypothalamischen Achse bedingt eine hohe Komorbidität der Kinder prä- und postoperativ. N2 - Craniopharyngioma are embryogenic malformations of the sellar area. With an overall incidence of 0.5–2 new cases per million population per year, 30–50% of all cases occur in childhood.As the survival rate after craniopharyngioma diagnosed during childhood and adolescence is high, prognosis and quality of life in survivors mainly depend on adverse late effects such as hypopituitarism and obesity. Appropriate laboratory diagnostics of endocrine deficiencies and sufficient hormonal substitution have significant impact on prognosis. A review of the literature reveal only some few cases of neonatal craniopharyngioma. Modern picture-giving proceeds such as MRI enable a early diagnosis. On the one hand there is a controversy concerning the radicalness and the time of operation on the other hand the microsurgical resection is meant to be the goldstandard in the therapy of neonatal craniopharyngiomas. KW - Neurochirurgie KW - Neugeborenes KW - NMR-Tomographie KW - Hypophyse KW - Hypophysenhormon KW - pränatal KW - Kraniopharyngeom KW - pterionaler Zugang KW - mikrochirurgische Resektion KW - Literatur KW - neonatal KW - craniopharyngioma KW - mri KW - ct-scan KW - literature Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-49757 ER - TY - JOUR A1 - Lewitzki, Victor A1 - Andratschke, Nicolaus A1 - Kuhnt, Thomas A1 - Hildebrandt, Guido T1 - Radiation myelitis after hypofractionated radiotherapy with concomitant gefitinib JF - Radiation Oncology N2 - We describe the case of a 71-year-old Caucasian female with primary disseminated non-small cell cancer of the lung, presented for palliative radiotherapy of metastatic spread to the 9th and 11th thoracic vertebrae without intramedullary growth. Palliative radiotherapy with daily fractions of 3 Gy and a cumulative dose of 36 Gy to thoracic vertebrae 8-12 was performed. The patient received concomitantly 250 mg gefitinib daily. After a latent period of 16 months, the patient developed symptoms of myelitis. Magnetic resonance imaging (MRI) did not reveal any bony or intraspinal tumor progression, but spinal cord signal alteration. No response to steroids was achieved. The neurological symptoms were progressive in August 2013 with the right leg being completely plegic. The left leg was incompletely paralyzed. Deep and superficial sensitivity was also diminished bilaterally. The patient was completely urinary and anally incontinent. Contrary to the clinical findings, a follow-up MRI (July 2013) showed amelioration of the former signal alterations in the spinal cord. The diagnosis of paraneoplastic myelopathy was refuted by a negative test for autologous antibodies. At the last clinical visit in May 2014, the neurological symptoms were stable. The last tumor-specific treatment the patient is receiving is erlotinib 125 mg/d. We reviewed the literature and found no reported cases of radiation myelopathy after the treatment in such a setting. The calculated probability of such complication after radiotherapy alone is statistically measurable at the level of 0.02%. We suppose that gefitinib could also play a role in the development of this rare complication. KW - radiation myelitis KW - concomitant radiotherapy KW - gefitinib Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-175443 VL - 10 IS - 29 ER - TY - JOUR A1 - Lenschow, Christina A1 - Fuss, Carmina Teresa A1 - Kircher, Stefan A1 - Buck, Andreas A1 - Kickuth, Ralph A1 - Reibetanz, Joachim A1 - Wiegering, Armin A1 - Stenzinger, Albrecht A1 - Hübschmann, Daniel A1 - Germer, Christoph Thomas A1 - Fassnacht, Martin A1 - Fröhling, Stefan A1 - Schlegel, Nicolas A1 - Kroiss, Matthias T1 - Case Report: Abdominal Lymph Node Metastases of Parathyroid Carcinoma: Diagnostic Workup, Molecular Diagnosis, and Clinical Management JF - Frontiers in Endocrinology N2 - Parathyroid carcinoma (PC) is an orphan malignancy accounting for only ~1% of all cases with primary hyperparathyroidism. The localization of recurrent PC is of critical importance and can be exceedingly difficult to diagnose and sometimes futile when common sites of recurrence in the neck and chest cannot be confirmed. Here, we present the diagnostic workup, molecular analysis and multimodal therapy of a 46-year old woman with the extraordinary manifestation of abdominal lymph node metastases 12 years after primary diagnosis of PC. The patient was referred to our endocrine tumor center in 2016 with the aim to localize the tumor causative of symptomatic biochemical recurrence. In view of the extensive previous workup we decided to perform [18F]FDG-PET-CT. A pathological lymph node in the liver hilus showed slightly increased FDG-uptake and hence was suspected as site of recurrence. Selective venous sampling confirmed increased parathyroid hormone concentration in liver veins. Abdominal lymph node metastasis was resected and histopathological examination confirmed PC. Within four months, the patient experienced biochemical recurrence and based on high tumor mutational burden detected in the surgical specimen by whole exome sequencing the patient received immunotherapy with pembrolizumab that led to a biochemical response. Subsequent to disease progression repeated abdominal lymph node resection was performed in 10/2018, 01/2019 and in 01/2020. Up to now (12/2020) the patient is biochemically free of disease. In conclusion, a multimodal diagnostic approach and therapy in an interdisciplinary setting is needed for patients with rare endocrine tumors. Molecular analyses may inform additional treatment options including checkpoint inhibitors such as pembrolizumab. KW - parathyroid carcinoma KW - abdominal lymph node metastases KW - molecular diagnostics KW - repeated surgery KW - [18F]FDG-PET-CT KW - immune check inhibitor KW - pembrolizumab Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-233362 SN - 1664-2392 VL - 12 ER - TY - THES A1 - Lauterbach, Brigitte T1 - Ganzkörper-MRT beim multiplen Myelom: Vergleich verschiedener MRT-Sequenzen in der Diagnostik fokaler und diffuser Infiltrationsmuster T1 - Whole-body MRI of multiple myeloma: Comparison of different MRI sequences in assessment of different growth patterns N2 - Die MRT hat die höchste Detektionsrate der radiologischen Verfahren zur Erkennung einer Knochenmarksinfiltration durch das multiple Myelom. In der vorliegenden Studie hatte die T2-w TIRM Sequenz die höchste Sensitivität. Es konnte jedoch kein signifikanter Unterschied zwischen der T2w-TIRM Sequenz und der T1-w TSE Sequenz festgestellt werden. Die Interobservervarianz war in Sitzung 2 (T2-w TIRM Sequenz) und Sitzung 3 (T2-w TIRM/T1-w TSE/KM +T1-w TSE Sequenz) gleichwertig. Durch Kontrastmittelgabe konnte die Sensitivität nicht signifikant verbessert werden. Zusammenfassend bietet die T2-w TIRM Sequenz die Möglichkeit einer ersten schnellen orientierenden Untersuchung. Für ein detailliertes radiologisches Staging, Grading und zum Therapiemonitoring sollte jedoch weiterhin eine MRT-Untersuchung mit T2-w TIRM/T1-w TSE Sequenz plus zusätzlicher Kontrastmittelzugabe erfolgen. N2 - For detecting bone marrow plasma cell infilration by multiple myeloma MR imaging ist superior to other imaging techniques. The following study shows that T2w-TIRM sequences achieved the highest level of sensitivity and the best reliability depending on infiltration grade and clinical stage. Differences between T2-w TIRM and T1w-TSE sequence are not significant. The interobserver variability was same in reading 2 (T2w-TIRM sequence) and reading 3 (T2w-TIRM/T1-w TSE/KM+ T1-w TSE sequence). Contrast-enhanced sequences could not significantly improve sensitivity. Conclusionally T2w-TIRM sequences might be valuable for initial assessment of MM. For an exact staging, grading and therapy monitoring the examination protocol should encompass unenhanced and enhanced T1w- MRI sequences in addition to T2w-TIRM. KW - Plasmozytom KW - NMR-Tomographie KW - Sequenzvergleich KW - MRI KW - Multiples Myelom KW - multiples myeloma KW - plasmocytoma KW - mri KW - whole-body MRI Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-53118 ER - TY - THES A1 - Laubmeier, Mona T1 - Wertigkeit der Multidetektorcomputertomographie in der präoperativen Diagnostik des Pankreaskarzinoms T1 - Diagnostic accuracy of MDCT for preoperative staging of pancreatic carcinoma N2 - Das Pankreaskarzinom stellt mit seiner schlechten Prognose und der Schwierigkeit, es in frühem Stadium zu erkennen, eine große Herausforderung für die Medizin dar. Es gibt zahlreiche diagnostische Möglichkeiten für die Detektion und das Staging dieses Malignoms. Hierfür hat sich als Mittel der ersten Wahl in den letzten Jahren die MD-Computertomographie bewährt. Das Ziel dieser Arbeit war es, die Treffsicherheit der Computertomographie für die Detektion als auch für die Einstufung der präoperativen Resektabilität zu bestimmen und herauszufinden, wo Fehlerquellen in der Bildbefundung liegen, um diese in Zukunft verbessern bzw. vermeiden zu können. Hierfür wurden 83 Patienten mit primärem Verdacht auf ein Pankreaskarzinom in die Studie einbezogen und die präoperativ erstellen Bilder retrospektiv befundet. Dabei ergaben sich Werte für die Sensitivität der Tumordetektion von 94 % und für die Spezifität von 43,75 %. Die Sensitivität zur Einschätzung der Resektabiliät eines Pankreaskarzinoms mit Hilfe des CTs in dieser Studie beträgt 64 % und die Spezifität 97,30 %. Die Ergebnisse an der Universität Würzburg sind damit vergleichbar mit den Ergebnissen anderer Untersuchungen an anderen Zentren. Trotz der hohen Bildqualität der Multidetektorcomputertomographie war es schwierig, eine chronische Pankreatitis von einem Karzinom zu unterscheiden. Besonders wichtig, vor allem in Zusammenarbeit mit der Visceralchirurgie, ist es, präoperativ festzulegen, ob der Tumor noch resektabel ist, um unnötig aufwändige Operationen zu vermeiden und Patienten mit resektablem Tumor die Chance auf eine potentiell kurative Therapie nicht zu verwehren. Ein in der Bildgebung primär irresektabel eingestufter Befund war mit fast 100 % auch tatsächlich irresektabel. Dagegen stellten sich 20 % der initital als resektabel eingestuften Befunde intraoperativ als irresektabel dar. Als Hauptursachen der falsch eingestuften Befunde fanden sich in dieser Studie Probleme in der Detektion eines arteriellen Gefäßbefalls, kleiner Lebermetastasen oder einer Peritonealkarzinose. Zu ähnlichen Ergebnissen kommen auch andere Autoren. Auch in Zukunft wird trotz weiterer technischer Fortschritte in der Schnittbildgebung eine sichere Unterscheidung wahrscheinlich nicht immer möglich sein. Folglich gilt es im präoperativen Staging des Pankreaskarzinoms, größtmögliche Sorgfalt walten zu lassen. Dies beinhaltet, so genau wie möglich, auf Hinweise zur Unterscheidung einer chronischen Pankreatitis, eines Karzinoms und der erwähnten Irresektabilitätskriterien zu achten. So wird im Rahmen, der durch technische Möglichkeiten gegebenen Treffsicherheit, ein Maximum an Genauigkeit sichergestellt. N2 - The aim of this study was to evaluate the accuracy of multidetector computed tomography (MDCT) in preoperative detection and assessment of resectability of pancreatic cancer using surgical and histopathologic correlation. The study included 83 patients with suspected locoregional pancreatic cancer. One radiologist retrospectively evaluated the imaging findings to determine the presence of pancreatic tumor and signs of unresectability. MDCT showed a sensitivity of 94 % and a specificity of 44 % for detection of pancreatic cancer, respectively. For assessing unresectability MDCT showed a sensitivity of 64 %, a specificity of 97%, respectively, a positive predictive value of 94 % and a negative predictive value of 82 %, respectively. MDCT is a useful technique for preoperative detection and staging of pancreatic cancer. The main limitation of CT is that it may not differentiate pancreatic cancer from pancreatitis and may not reveal peritoneal or small hepatic metastases, and vascular encasement. KW - Pankreaskarzinom KW - Pankreaskarzinom präoperativ KW - Wertigkeit KW - MDCT Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159789 ER - TY - JOUR A1 - Laqua, Fabian Christopher A1 - Woznicki, Piotr A1 - Bley, Thorsten A. A1 - Schöneck, Mirjam A1 - Rinneburger, Miriam A1 - Weisthoff, Mathilda A1 - Schmidt, Matthias A1 - Persigehl, Thorsten A1 - Iuga, Andra-Iza A1 - Baeßler, Bettina T1 - Transfer-learning deep radiomics and hand-crafted radiomics for classifying lymph nodes from contrast-enhanced computed tomography in lung cancer JF - Cancers N2 - Objectives: Positron emission tomography (PET) is currently considered the non-invasive reference standard for lymph node (N-)staging in lung cancer. However, not all patients can undergo this diagnostic procedure due to high costs, limited availability, and additional radiation exposure. The purpose of this study was to predict the PET result from traditional contrast-enhanced computed tomography (CT) and to test different feature extraction strategies. Methods: In this study, 100 lung cancer patients underwent a contrast-enhanced \(^{18}\)F-fluorodeoxyglucose (FDG) PET/CT scan between August 2012 and December 2019. We trained machine learning models to predict FDG uptake in the subsequent PET scan. Model inputs were composed of (i) traditional “hand-crafted” radiomics features from the segmented lymph nodes, (ii) deep features derived from a pretrained EfficientNet-CNN, and (iii) a hybrid approach combining (i) and (ii). Results: In total, 2734 lymph nodes [555 (20.3%) PET-positive] from 100 patients [49% female; mean age 65, SD: 14] with lung cancer (60% adenocarcinoma, 21% plate epithelial carcinoma, 8% small-cell lung cancer) were included in this study. The area under the receiver operating characteristic curve (AUC) ranged from 0.79 to 0.87, and the scaled Brier score (SBS) ranged from 16 to 36%. The random forest model (iii) yielded the best results [AUC 0.871 (0.865–0.878), SBS 35.8 (34.2–37.2)] and had significantly higher model performance than both approaches alone (AUC: p < 0.001, z = 8.8 and z = 22.4; SBS: p < 0.001, z = 11.4 and z = 26.6, against (i) and (ii), respectively). Conclusion: Both traditional radiomics features and transfer-learning deep radiomics features provide relevant and complementary information for non-invasive N-staging in lung cancer. KW - computed tomography KW - computational neural networks KW - lymphatic metastasis KW - carcinoma KW - non-small-cell lung KW - small-cell lung Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-319231 SN - 2072-6694 VL - 15 IS - 10 ER - TY - THES A1 - Laqua, Caroline T1 - Association of myocardial tissue characteristics and functional outcome in biopsy-verified myocarditis assessed by cardiac magnetic resonance imaging T1 - Zusammenhänge zwischen geweblichen Eigenschaften des Myokards und funktionellem Outcome bei biopsie-verifizierter Myokarditis im Kardio-MRT N2 - The relation between LV function and cardiac MRI tissue characteristics in separate myocardial segments and their change over time has yet to be explored in myocarditis. Thus, our research aimed to investigate possible associations between global and regional myocardial T1 and T2 times and peak strain in patients with suspected myocarditis. From 2012 to 2015, 129 patients with clinically suspected myocarditis of the prospective, observational MyoRacer-Trial underwent systematic biventricular EMB at baseline and cardiac MRI at baseline and after three months as a follow-up. We divided the LV myocardium into 17 segments and estimated the segmental myocardial strain using FT. We registered T1 and T2 maps to the cine sequences and transferred the segmentations used for FT to ensure conformity of the myocardial segments. Multi-level multivariable linear mixed effects regression was applied to investigate the relation of segmental myocardial strain to relaxation times and their respective change from baseline to follow-up. We found a significant improvement in myocardial peak strain from baseline to follow-up (p < 0.001; all p-values given for likelihood ratio tests) and significant associations between higher T1 and T2 times and lower segmental myocardial peak strain (p ranging from < 0.001 to 0.049). E.g., regression coefficient (Reg. coef.) for segmental radial peak strain in short axis view (SRPS_SAX) and T1 time: -1.9, 95% CI (-2.6;-1.2) %/100 ms, p < 0.001. A decrease in T1 and T2 times from baseline to follow-up was also significantly related to a recovery of segmental peak strains (p ranging from < 0.001 to 0.050). E.g., Reg. coef. for SRPS_SAX per ΔT1: -1.8, 95% CI (-2.5;-1.0) %/100 ms, p < 0.001. Moreover, the higher the baseline T1 time, the more substantial the functional recovery from baseline to follow-up (p ranging from 0.004 to 0.042, e.g., for SRPS_SAX: Reg. coef. 1.3, 95% CI (0.4;2.1) %/100 ms, p 0.004). We did not find an effect modification by the presence of myocarditis in the EMB (p > 0.1). Our cross-sectional and longitudinal analyses provide evidence of dose-dependent correlations between T1 and T2 relaxation times and myocardial peak strain in patients with clinical presentation of myocarditis, regardless of the EMB result. Thus, assessing strain values and mapping relaxation times helps estimate the functional prognosis in patients with clinically suspected myocarditis. N2 - Die Zusammenhänge zwischen der kardialen linksventrikulären (LV) Funktion und magnetresonanztomographisch erhebbaren Parametern des Myokards sowie deren jeweiligen Entwicklungen im zeitlichen Verlauf einer Myokarditis sind bisher nicht umfassend untersucht. Daher beschäftigt sich die vorliegende Arbeit mit der Erforschung des Verhältnisses von globalen und regionalen peak strain-Werten und T1 und T2 Zeiten des LV Myokards in der Magnetresonanztomographie (MRT) bei Patienten mit Verdacht auf Myokarditis. Die MyoRacer-Studie ist eine prospektive Beobachtungsstudie, die von 2012 bis 2015 am Herzzentrum des Universitätsklinikums Leipzig durchgeführt wurde. Dabei wurden 129 Patienten mit klinischem Verdacht auf Myokarditis mittels biventrikulärer Myokardbiopsie sowie kardialer MRT untersucht. Drei Monate nach der Erstuntersuchung (EU) erfolgte eine MRT-Folgeuntersuchung (FU). Für unsere Analysen unterteilten wir das LV Myokard standardmäßig in 17 Segmente, um mithilfe der Technik des feature trackings den segmentalen peak strain zu evaluieren. Weiterhin registrierten wir T1 und T2 maps gegen cine-Sequenzen der MRT und übertrugen die Segmentierungen aus den cine-Sequenzen zwecks Übereinstimmung in die MRT maps. Anschließend analysierten wir die Zusammenhänge zwischen segmentalem strain und T1 und T2 Zeiten und deren jeweiligen Veränderungen im zeitlichen Verlauf mithilfe eines hierarchischen, multivariablen, gemischten linearen Regressionsmodells. Unsere Ergebnisse zeigen eine signifikante Verbesserung der peak strain-Werte von der EU zur FU (p < 0.001; alle p-Werte für likelihood ratio tests angegeben) sowie eine signifikante Assoziation von erhöhten T1 und T2 Zeiten mit verminderten segmentalen peak strain-Werten (p zwischen < 0.001 und 0.049). Weiterhin war ein Abfall der T1 und T2 Zeiten von der EU zur FU signifikant mit einer Erholung der segmentalen peak strain-Werte verknüpft (p zwischen < 0.001 und 0.050). Je höher die T1 Zeiten bei der EU ausfielen, desto stärker erholte bzw. verbesserte sich der peak strain von der EU zur FU (p zwischen 0.004 und 0.042). Eine Effektmodifikation durch den bioptischen Nachweis einer Myokarditis war nicht zu beobachten (p > 0.1). Unsere Quer- und Längsschnittanalysen belegen dosisabhängige Zusammenhänge zwischen T1 und T2 Zeiten und myokardialen peak strain-Werten bei Patienten mit dem klinischen Bild einer Myokarditis, unabhängig vom Ergebnis der Myokardbiopsie. Daher ist die Bestimmung von T1 und T2 Zeiten und myokardialem strain mittels kardialer MRT zur Abschätzung der funktionellen Prognose bei Patienten mit klinischem Verdacht auf Myokarditis hilfreich. KW - Myokarditis KW - Kernspintomografie KW - T1-Zeit KW - T2-Zeit KW - strain KW - t1 time KW - t2 time KW - myocarditis KW - MRI Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-363903 ER - TY - THES A1 - Langhammer, Romy T1 - Metabolomic Imaging for Human Prostate Cancer Detection using MR Spectroscopy at 7T T1 - Prostatakrebsdiagnostik mittels metabolomischer Bildgebung in Verwendung von Magnetresonanzspektroskopie mit 7T N2 - BACKGROUND. Prostate cancer (PCa) remains a major health concern in men of the Western World. However, we still lack effective diagnostic tools a) for an effective screening with both high sensitivity and specificity, b) to guide biopsies and avoid histology sampling errors and c) to predict tumor aggressiveness in order to avoid overtreatment. Therefore, a more reliable, highly cancer-specific and ideally in vivo approach is needed. The present study has been designed in order to further develop and test the method of "metabolomic imaging" using magnetic resonance spectroscopy (MRS) at 7T to address those challenges. METHODS. Thirty whole prostates with biopsy-proven PCa were in vitro analyzed with a 7T human MR scanner. A voxel grid containing the spectral information was overlaid with the MR image of the middle transverse cross-sectional plane of each case. Subsequent histopathological evaluation of the prostate specimen followed. After the spectral output was processed, all voxels were compared with a metabolomic PCa profile, which had been established within a preliminary study, in order to create a metabolomic map indicating MRS cancer-suspicious regions. Those regions were compared with the histologically identified tumor lesions regarding location. RESULTS. Sixty-one percent of the histological cancer lesions were detected by metabolomic imaging. Among the cases with PCa on the examined slice, 75% were identified as cancerous. None of the tested features significantly differed between detected and undetected cancer lesions. A defined "Malignancy Index" (MI) significantly differentiated between MRS-suspicious lesions corresponding with a histological cancer lesion and benign lesions (p = 0.006) with an overall accuracy of 70%. The MI furthermore showed a positive correlation with the Gleason grade (p = 0.021). CONCLUSION. A new approach within PCa diagnostics was developed with spectral analysis including the whole measureable metabolome - referred to as "metabolomics" - rather than focusing on single metabolites. The MI facilitates precise tumor detection and may additionally serve as a marker for tumor aggressiveness. Metabolomic imaging might contribute to a highly cancer-specific in vivo diagnostic protocol for PCa. N2 - Diese Studie befasst sich mit der Diagnostik von Prostatakarzinomen mittels metabolomischer Bildgebung auf Grundlage der Magnetresonanzspektroskopie. An dreißig Organen mit gesichertem Prostatakarzinom wurde nach Prostatektomie in vitro ein Magnetic-Resonance-Spectroscopy-Imaging (MRSI)-Scan mit 7T durchgeführt. Die Auswertung der prostatischen Spektren erfolgte mittels eines in einer Vorstudie definierten Prostatakrebs-Profils, das die metabolomischen Daten des gesamten messbaren Metaboloms einbezog. Die Ergebnisse der metabolomischen Bildgebung wurden anschließend mit denen der histologischen Untersuchung nach dem MRSI-Scan verglichen. 61% der histologisch nachgewiesenen Krebsläsionen konnten mittels der metabolomischen Bildgebung detektiert werden. Ein "Malignancy Index" unterschied signifikant zwischen malignen MRSI-Läsionen sowie den falsch Positiven. Er dient nachweislich als möglicher Marker für Tumoraggressivität. Mit der metabolomischen Bildgebung wurde ein Verfahren vorgestellt, das hochspezifisch für das Prostatakarzinom ist, eine Tumorlokalisation vor Biopsieentnahme ermöglicht sowie eine Abschätzung der Tumoraggressivität und möglichen Progression erlaubt. Dennoch sind weitere Studien erforderlich, um das Verfahren sowie insbesondere die Sensitivität zu verbessern. KW - Prostatakrebs KW - Protonen-NMR-Spektroskopie KW - Metabolomic Imaging KW - Magnetic Resonance Spectroscopy Imaging KW - Prostate cancer diagnostics KW - Metabolomics Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-165772 ER - TY - THES A1 - Laas, Susanne Franziska T1 - Stellenwert der kontrastmittelverstärkten MRT bei traumatischen Verletzungen und posttraumatischen Veränderungen an der Hand T1 - The importance of contrast-enhanced MRI in traumatic and posttraumatic injuries of the hand N2 - Die vorliegende Arbeit hat zum Ziel, den Stellenwert von kontrastverstärkten MR- Sequenzen in der bildgebenden Diagnostik von Hand und Fingern zu untersuchen. Denn trotz einer breiten empirischen Anwendung von gadoliniumhaltigen Kontrastmitteln im europäischen Raum besteht keine ausreichende wissenschaftliche Datengrundlage zur kontrastverstärkten Hand-MRT nach einem Trauma. Zu diesem Zweck wurden zwischen Januar 2016 und August 2018 am Rhön-Klinikum Campus Bad Neustadt 165 MRT-Untersuchungen von distalem Unterarm, Karpus, Metakarpus und/oder Fingern selektiert. Einschlusskriterien waren eine positive Traumaanamnese, standardisierte MRT-Sequenzen und das Fehlen von Kontraindikationen. Zur Definition eines diagnostischen Referenzstandards wurden alle Fälle vorab durch einen Senior-Investigator mit 36 Jahren Erfahrung in muskuloskelettaler Radiologie analysiert. Für die Bildevaluation wurden aus jeder MRT-Untersuchung zwei Datensätze erstellt, wobei der erste Datensatz nur die nativen Sequenzen (PD / T2 FSE fs und T1 FSE ) und der zweite Datensatz zusätzlich zu eine kontrastverstärkte Sequenz als T1 FSE fs nach Gadolinium-Applikation enthielt. Als Observer fungierten zwei radiologische Fach- bzw. Oberärzte des Universitätsklinikum Würzburgs. In der vorliegenden Studie wurde ein diagnostisch relevantes Kontrastmittelenhancement an Patienten mit traumatischen Handverletzungen nachgewiesen. Der Kontrastmitteleffekt war mit subjektiven und objektiven Messgrößen statistisch signifikant bei Läsionen der Ligamente und an den ligamentähnlichen Insertionen des ulnaren TFCC-Abschnittes. Als Erklärung für das Kontrastmittelenhancement in der MRT dient in erster Linie die bereits früher beschriebene Hyperämie, die posttraumatisch am Traumaort mit Ausgang von der Synovialis entsteht. Anhand der Studienergebnisse kann die Empfehlung ausgesprochen werden, in der MRT-Diagnostik von traumatischen Läsionen der Hand immer dann intravenöses Kontrastmittel auf Gadolinium-Basis zu verabreichen, wenn am vermuteten Läsionsort der T2-Kontrast für eine sichere Diagnose unzureichend ist. N2 - The aim of this study was to examine the impact of contrast-enhanced MRI-sequences in radiological diagnostics of the wrist and fingers. In spite of widespread empirical usage of gadolinium-enhanced contrast agents in Europe, there is insufficient scientific data regarding the contrast-enhanced MRT of the posttraumatic hand. In this study, 165 MRT scans of the distal forearm, carpus, metacarpus and/or fingers were selected at the Rhön-Klinikum Campus Bad Neustadt between January 2016 and August 2018. Inclusion criteria included a positive trauma anamnesis, standardized MRT sequences and the lack of contra-indications. In order to define a diagnostic standard as a reference, each case was analyzed beforehand by a senior-investigator with 36 years of professional experience in musculoskeletal radiology. Two data records were generated from each MRI-Scan, the first data record containing only the native sequences (PD / T2 FSE fs and T1 FSE) and the second record containing an additional contrast-enhanced sequence as T1 FSE fs after gadolinium. Two radiological specialists/assistant medical directors of the Universitätsklinikum Würzburg served as observers. This study succeeded in demonstrating diagnostically relevant contrast enhancement in patients with traumatic hand injuries. It is known that enhancement in MRI scans is linked to posttraumatic synovial hyperemia. The positive diagnostic effect of gadolinium enhancement was demonstrated in ligament lesions and insertions of the ulnar TFCC and proved statistically significant in the subjective and objective radiological examination. Taking these results into account, intravenous application of gadolinium may be beneficial when interpreting traumatic lesions of the hand, especially when T2-contrast is not sufficient for diagnosis. KW - Intravenöse Applikation KW - Kontrastmittel KW - Kernspintomographie KW - Hand KW - Trauma KW - MRT KW - gadoliniumhaltiges Kontrastmittel KW - intravenös KW - traumatisch KW - Karpus KW - TFCC KW - Triangulärer fibrokartilaginärer Komplex KW - SL-Band KW - Hyperämie Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-299370 ER - TY - THES A1 - Kurre, Corinna T1 - Single-Center Erfahrungen bezüglich des Einsatzes eines „Cutting Balloon Katheters“ (= perkutane transluminale Blade-Angioplastie) bei Patienten mit stenosierten Hämodialyseshunts T1 - Using a cutting balloon catheter (= percutaneous transluminal blade angioplasty) for stenotic haemodialysis access: a single center study N2 - Ziel der Arbeit Die vorliegende Arbeit spiegelt Erfahrungen bezüglich des Einsatzes von Cutting Balloon Kathetern in stenosierten Hämodialyseshunts im Institut für Diagnostische und Interventionelle Radiologie der Universitätsklinik Würzburg wider. Ziel war vor allem die Erfassung der technischen und klinischen Erfolgsrate sowie die Untersuchung der primären Offenheitsraten unter verschiedenen Gesichtspunkten und der Komplikationsrate. Patienten, Material, Methoden Zwischen Mai 2006 und Oktober 2010 wurden 44 Interventionen an chronisch niereninsuffizienten Patienten mit stenosierten Dialyseshunts mittels Cutting Balloon Kathetern durchgeführt. Diese wurden retrospektiv ausgewertet. 26 Patienten waren männlich, 18 weiblich. Das Durchschnittsalter zum Zeitpunkt der PTA betrug 66,2 Jahre (±13,3 Jahre). 38 der 44 Patienten erreichten das Follow Up von 450 Tagen. Bei den Interventionen kamen neben den Peripheral Cutting Balloons® (Boston Scientific Corporation, Natick, MA, USA) (n=45) auch konventionelle Ballonkatheter (n=77) und Hochdruckballonkatheter (n=2) zum Einsatz. Betrachtet wurden der technische, klinische und hämodynamische Erfolg, die primären Offenheitsraten nach 30, 60 und 180 Tagen unter verschiedenen Gesichtspunkten sowie die Komplikationsrate. Ergebnisse In neun Fällen konnte durch die DSA der Nachweis von mehr als einer Stenose ausgemacht werden. Insgesamt wurden 62 Stenosen diagnostiziert, wovon 52 mittels Cutting Balloons behandelt wurden. Die Stenosen, welche mittels Cutting Balloons behandelt wurden, wiesen im Mittel eine Länge von 2,6 cm (±2,1 cm) auf. Der technische Erfolg lag bei 100%. Die klinische Erfolgsrate lag bei 92,9%. Hämodynamischer Erfolg konnte in 65,9% der Fälle erzielt werden. Die primäre Offenheitsrate betrug im Mittel 178,2 Tage (±22,8). Sie betrug nach 30 Tagen 88,6%, nach 90 Tagen 68,2% und nach 180 Tagen 36,4%. Bei den Patienten mit autologen Shunts betrug die primäre Offenheitsrate im Mittel 215,0 Tage (±27,3). Sie betrug in diesem Patientenkollektiv nach 30 Tagen 90,9%, nach 90 Tagen 78,8% und nach 180 Tagen 48,5%. Bei den Patienten mit alloplastischen Shunts lag die primäre Offenheitsrate im Schnitt bei 67,8 Tagen (±12,0). Sie betrug hier nach 30 Tagen 81,8%, nach 90 Tagen 36,4% und nach 180 Tagen 0%. Der Unterschied der primären Offenheitsraten war für autologe vs. alloplastische Shunts statistisch signifikant (p=0,002). Die primäre Offenheitsrate betrug im Mittel bei Patienten mit Diabetes mellitus 248,5 Tage (±42,2). Sie betrug in diesem Patientenkollektiv nach 30 Tagen 88,2%, nach 90 Tagen 76,5% und nach 180 Tagen 52,9%. Bei Patienten ohne Diabetes mellitus lag die primäre Offenheitsrate im Schnitt bei 133,9 Tagen (±22,7). Sie betrug hier nach 30 Tagen 85,2%, nach 90 Tagen 63,0% und nach 180 Tagen 25,9%. Der Unterschied der primären Offenheitsraten war bei Diabetikern vs. Nicht-Diabetikern statistisch nicht signifikant. Die primäre Offenheitsrate betrug im Mittel bei den Patienten mit Dyslipoproteinämie 153,6 Tage (±36,9). Sie betrug in diesem Patientenkollektiv nach 30 Tagen 78,9%, nach 90 Tagen 47,4% und nach 180 Tagen 31,6%. Bei den Patienten ohne Dyslipoproteinämie lag die primäre Offenheitsrate im Schnitt bei 196,9 Tagen (±28,8). Sie betrug hier nach 30 Tagen 96,0%, nach 90 Tagen 84,0% und nach 180 Tagen 40,0%. Der Unterschied der primären Offenheitsraten war bei Patienten mit vs. Patienten ohne Dyslipoproteinämie statistisch signifikant (p=0,009). 90,9% der Interventionen (n=40) verliefen komplikationslos. In 9,1% der Fälle (n=4) traten Komplikationen auf, die gemäß den SIR Reporting Standards (62) zu den Minor-Komplikationen zählen. Fazit Die PTA mittels Cutting Balloon Katheter stellt bei hohem technischem und klinischem Erfolg sowie niedriger Komplikationsrate eine effektive Behandlungsmethode stenosierter Hämodialyseshunts dar. Weitere Studien werden benötigt, um im Hinblick auf die Kosten-Nutzen-Relation eindeutige Indikationsstellungen für den Einsatz des Cutting Balloons in dysfunktionellen Hämodialyseshunts zu etablieren. N2 - The study is about a retrospective analysis of 44 interventions on patients with chronic renal failure, having had a percutaneous transluminal angioplasty with a cutting balloon catheter in the Institute of Diagnostic and Interventional Radiology of the University of Wuerzburg in the period of May 2006 to October 2010. In total 26 men and 18 women were treated. The average age of the patients at the time of intervention was 66,2 years (±13,3 years). 38 of 44 patients reached the follow up of 450 days. Beside the Peripheral Cutting Balloons® (Boston Scientific Corporation, Natick, MA, USA) (n=45) also conventional balloon catheters (n=77) and high pressure balloon catheters (n=2) were used to treat lesions. We retrospectively analyzed the technical, clinical and haemodynamic success as well as primary patency rates after 30, 60 and 180 days from various perspectives and also the rate of complications. Via digital subtraction angiography more than one stenosis was reported in nine cases. In total 62 stenoses were diagnosed, whereof 52 were treated with cutting balloons. Stenoses, treated by cutting balloons, have had an average length of 2,6 cm (±2,1 cm). The technical success was 100%, clinical success rated 92,9% and haemodynamic success could be reached in 65,9% of all cases. The primary patency rate was in average 178,2 days (±22,8), 88,6% after 30 days, 68,2% after 90 days and 36,4% after 180 days. We reported that 90,9% of all interventions (n=40) did not cause any complications. There had been complications in 9,1% of all cases (n=4), which pertain to minor complications in accordance with the SIR Reporting Standards. In conclusion PTA with a cutting balloon catheter is an effective method to treat stenoses in haemodialysis accesses and has high technical and clinical success rates as well as a low rate of complications. Further studies are requested to establish clear indications for the use of a cutting balloon catheter for stenotic lesions in haemodialysis accesses in regards to its costeffectiveness. KW - Perkutane transluminale Angioplastie KW - cutting balloon KW - Schneideballon KW - blade angioplastie KW - Shuntstenose Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-138120 ER - TY - THES A1 - Kunz, Julian T1 - Wertigkeit der Absoluten Quantitativen Perfusionsauswertung nach Myokardinfarkt im Akutstadium und im Langzeitverlauf mittels Magnetresonanztomographie T1 - Validity of perfusion measurement using MRI in the acute stage of myocardial infarction and upon one year follow up N2 - Es wurden Perfusionsmessungen mittels MRT an Infarktpatienten im Akutstadium und im Langzeitverlauf durchgeführt und quantitativ mittels einem Sektormodell ausgewertet. Hierbei zeigte sich, dass sich die Perfusionswerte im Infarktareal und gesunden Myokard nicht signifikant unterschieden und dass sich diese auch im Jahresverlauf nicht signifikant änderten. Es ergab sich auch keine signifikante Korrelation zwischen der Größe des Infarkareales und den gemessenen Perfusionswerten. N2 - Quantitative cardiac perfusion was measured in the acute stage of myocardial infarction by means of MRI, as well as upon one year follow-up. Using a sector based model, measured perfusion values did not differ significantly between infarcted and non-infarcted tissue. Also, a significant change between the perfusion value upon one year follow-up could not be shown. Furthermore, no significant correlation between perfusion values and the size of the infarcted area could be shown. KW - Kernspintomografie KW - Funktionelle Kernspintomografie KW - Herzinfarkt KW - Cardioperfusion Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-220952 ER - TY - JOUR A1 - Krämer, Johannes A1 - Bijnens, Bart A1 - Störk, Stefan A1 - Ritter, Christian O. A1 - Liu, Dan A1 - Ertl, Georg A1 - Wanner, Christoph A1 - Weidemann, Frank T1 - Left ventricular geometry and blood pressure as predictors of adverse progression of Fabry cardiomyopathy JF - PLoS ONE N2 - Background In spite of several research studies help to describe the heart in Fabry disease (FD), the cardiomyopathy is not entirely understood. In addition, the impact of blood pressure and alterations in geometry have not been systematically evaluated. Methods In 74 FD patients (mean age 36±12 years; 45 females) the extent of myocardial fibrosis and its progression were quantified using cardiac magnetic-resonance-imaging with late enhancement technique (LE). Results were compared to standard echocardiography complemented by 2D-speckle-tracking, 3D-sphericity-index (SI) and standardized blood pressure measurement. At baseline, no patient received enzyme replacement therapy (ERT). After 51±24 months, a follow-up examination was performed. Results Systolic blood pressure (SBP) was higher in patients with vs. without LE: 123±17 mmHg vs. 115±13 mmHg; P = 0.04. A positive correlation was found between SI and the amount of LE-positive myocardium (r = 0.51; P<0.001) indicating an association of higher SI in more advanced stages of the cardiomyopathy. SI at baseline was positively associated with the increase of LE-positive myocardium during follow-up. The highest SBP (125±19 mmHg) and also the highest SI (0.32±0.05) was found in the subgroup with a rapidly increasing LE (ie, ≥0.2% per year; n = 16; P = 0.04). Multivariate logistic regression analysis including SI, SBP, EF, left ventricular volumes, wall thickness and NT-proBNP adjusted for age and sex showed SI as the most powerful parameter to detect rapid progression of LE (AUC = 0.785; P<0.05). Conclusions LV geometry as assessed by the sphericity index is altered in relation to the stage of the Fabry cardiomyopathy. Although patients with FD are not hypertensive, the SBP has a clear impact on the progression of the cardiomyopathy. KW - cardiovascular magnetic resonance KW - clinical manifestations KW - disease KW - identification KW - fibrosis KW - 2-dimensional speckle tracking KW - myocardial infarction KW - therapy KW - diagnosis KW - impact Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-145131 VL - 10 IS - 11 ER - TY - THES A1 - Krupinski, Tabea T1 - Nachweis von morphologischen Veränderungen beim Nierenscreening von Frühgeborenen und deren klinische Relevanz T1 - Significance of planimetry and densitometry of sonograms in preterm infantswith suspected minor nephrocalcinosis N2 - Die Sonographie ist für die Diagnosestellung der Nephrokalzinose Goldstandard. Gerade durch die technische Weiterentwicklung kommen aber immer wieder neue Herausforderungen auf den Untersucher zu. Höhere Frequenzen und dadurch höhere Auflösungen der Bilder führen zu einer häufigeren Darstellung von Veränderungen, die es zu interpretieren gilt. So kommt es bei Nierenuntersuchungen Frühgeborener auffällig oft zu einem Auftreten von Echogenitätsanhebungen, die meist als Nephrokalzinose diagnostiziert werden. Die vorliegende Studie sollte durch Messungen von Helligkeit und Größenverhältnissen, sowie durch Auswertung bestimmter Laborparameter weitere und unabhängigere Kriterien zur Diagnosestellung der Nephrokalzinose finden. N2 - To assess the possible additional value of planimetry and densitometry of sonograms in preterm infants (PI) with sonographically suspected minor nephrocalcinosis (NC). KW - Ultraschall KW - Frühgeborenes KW - Planimetrie KW - Nephrokalzinose KW - Echogenität KW - nephrocalcinosis KW - echogenicity KW - preterm infants KW - ultrasound Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-73915 ER - TY - THES A1 - Kraus, Philip T1 - Verbesserung von Echoplanarer Bildgebung durch Phasenkorrektur T1 - Improvement of echoplanar imaging by phase correction N2 - Die Arbeit liefert eine Übersicht zu möglichen Korrekturen dynamischer Off-Resonanzen in dichtegewichteten und kartesischen echoplanaren funktionellen MRT Sequenzen. N2 - This scientific work gives an overview about potential corrections of dynamic off-resonances in k-space in density weighted and cartesian MRI sequences. KW - Kernspintomografie KW - Echoplanare Bildgebung KW - Phasenkorrektur KW - MRT KW - Off.Resonanzen Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-154462 ER - TY - JOUR A1 - Kraemer, Markus A1 - Becker, Jana A1 - Bley, Thorsten Alexander A1 - Steinbrecher, Andreas A1 - Minnerup, Jens A1 - Hellmich, Bernhard T1 - Diagnostik und Therapie der Riesenzellarteriitis T1 - Diagnostics and treatment of giant cell arteritis JF - Der Nervenarzt N2 - Die Riesenzellarteriitis (RZA) ist in der Altersgruppe der über 50-Jährigen die häufigste idiopathische systemische Vaskulitis. Die Erkrankung bedarf einer zeitnahen Diagnostik und Therapie, um schwere Komplikationen wie eine Erblindung oder einen Schlaganfall zu vermeiden. Die Rezidivneigung erfordert eine mehrjährige, zum Teil lebenslange Glukokortikoid(GC)-Therapie, was das Risiko GC-induzierter Langzeitnebenwirkungen erhöht. Daher wird bei der Mehrzahl der Patienten eine additive GC-einsparende Therapie empfohlen. Hierzu steht der Anti-IL-6-Rezeptor-Antikörper Tocilizumab in subkutaner Applikation als zugelassene Substanz zur Verfügung, alternativ kann Methotrexat (MTX) eingesetzt werden (off-label). N2 - Giant cell arteritis (GCA) is the most common idiopathic systemic vasculitis in the age group over 50 years. It requires prompt diagnostics and treatment to avoid severe complications, such as visual loss or stroke. The tendency to relapse makes a glucocorticoid (GC) treatment necessary for several years and sometimes lifelong, which increases the risk of GC-induced long-term side effects. Therefore, additive GC-sparing treatment is recommended in the majority of patients. For this purpose, the anti-IL‑6 receptor antibody tocilizumab is available as an approved substance for subcutaneous application; alternatively, methotrexate (MTX) can be used (off-label). KW - Riesenzellarteriitis KW - Diagnose KW - Therapie KW - Glukokortikoide KW - Glukokortikoideinsparende Therapie KW - Tocilizumab KW - Methotrexat KW - giant cell arteritis KW - diagnosis KW - therapy KW - glucocorticoids KW - glucocorticoid-sparing agents KW - Tocilizumab KW - Methotrexate Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-307771 SN - 0028-2804 SN - 1433-0407 VL - 93 IS - 8 ER - TY - THES A1 - Kowallik, Eva-Sophia T1 - Ausmaß und Korrelation von Late Gadolinium Enhancement, mikrovaskulärer Obstruktion und intramyokardialer Einblutung als prognostische Faktoren für das Remodeling bei Patienten nach Myokardinfarkt T1 - Prognostic value of late gadolinium enhancement, microvascular obstruction and intramyocardial hemorrhage on left ventricular remodeling in patients with myocardial infarction N2 - Hintergrund Kardiale Magnetresonanztomographie (CMR) kann für den Nachweis und die Bestimmung von Late Gadolinium Enhancement (LGE), mikrovaskulärer Obstruktion (MO) und intramyokardialer Einblutung (IMH) genutzt werden. Die Studie hat zum Ziel, den prognostischen Nutzen dieser drei MRT-Parameter bei der Entwicklung linksventrikulären Remodelings nach Myokardinfarkt (MI) zu evaluieren. Methoden Das Studienkollektiv umfasste 55 Patienten (Alter: 56±11 Jahre; Geschlecht: 53 m/2 w), welche nach dem Erstereignis eines Myokardinfarkts durch primäre Koronarintervention therapiert wurden. CMR mit Late Gadolinium Enhancement (LGE), First Pass Perfusion (FPP) und T2 gewichteter (T2w) Turbospinecho-Sequenz wurde 72 Stunden und ein Jahr nach MI durchgeführt. Linksventrikuläres Remodeling wird dabei als Anstieg des enddiastolischen Volumens um ≥ 20% und/oder einem Abfall der Ejektionsfraktion um > 10% definiert. Ergebnisse Late Gadolinium Enhancement ist eine effektive Methode, um die Infarktgröße zu bestimmen. Dabei zeigten 77,70 % der Patienten mit linksventrikulärem Remodeling eine Infarktgröße die 20 % der linksventrikulären Masse überschritt. Als ein Teilaspekt der vorliegenden Studie wurden die Patienten in drei Gruppen anhand der Ergebnisse ihrer Koronarintervention unterteilt (RIVA: n= 26; RCA: n= 20; RCX: n = 8). In der Jahresuntersuchung wiesen Patienten mit Vorderwandinfarkt eine niedrigere Ejektionsfraktion, einen signifikanten Anstieg des enddiastolischen Volumens und eine größere Infarktgröße als Probanden mit anderen Infarktlokalisationen auf. Ungefähr die Hälfte aller Remodelingpatienten erlitt einen Verschluss der RIVA. Mikrovaskuläre Obstruktion kann sowohl in der LGE Sequenz, als auch in der First Pass Perfusion nachgewiesen werden. In dieser Studie zeigt sich, dass die Größe der MO in der LGE Sequenz 80 % kleiner als in der FPP ausfiel. Dennoch besitzt die Anwesenheit der MO in der LGE Sequenz den größeren prognostischen Wert, da hier vor allem die ausgeprägten Areale der mikrovaskulären Obstruktion zur Darstellung kommen und Patienten mit diesen gefährdeter sind, ventrikuläres Remodeling zu entwickeln. Patienten mit MO (= MO (+)) (FPP: n= 42; LGE: n=27) besaßen eine kleinere Ejektionsfraktion (20 %), ein größeres enddiastolisches Volumen (24 %) und größere Infarktareale (170 %) in der Jahreskontrolle als Patienten ohne MO (= MO (-)) Intramyokardiale Einblutung wurde bei 29 Patienten (= IMH (+)) beobachtet, welche eine niedrige Ejektionsfraktion (17 %), ein höheres enddiastolisches Volumen (19 %) und eine größere Infarktgröße (180 %) als Patienten ohne IMH (= IMH (-)) nach einem Jahr aufwiesen. IMH fand sich in 72,15% der Patienten mit linksventrikulärem Remodeling. Zusammenfassung Late Gadolinium Enhancement, mikrovaskuläre Obstruktion und intramyokardiale Einblutung können zur Vorhersage linksventrikulären Remodelings bei Patienten nach Myokardinfarkt verwendet werden. In der vorliegenden Studie waren der Nachweis von MO in der LGE Sequenz und die Anwesenheit von IMH in der T2-Bildgebung die aussagekräftigsten prognostischen Faktoren. N2 - Background Cardiovascular magnetic resonance (CMR) can be used to detect and messure late gadolinium enhancement (LGE), microvascular obstruction (MO) and intramyocardial hemorrhage (IMH). This study aimed to evaluate the prognostic value of these three CMR parameters on the development of left ventricular remodeling after myocardial infarction (MI). Methods Fifty-five patients (age: 56±11 years; gender: 53 m/2 f) with a first myocardial infarction undergoing primary percutaneous coronary intervention were studied. CMR including late gadolinium enhancement (LGE), first pass perfusion (FPP) and T2 weighted (T2w) turbospinecho sequence was performed 72 h and 1 year after MI. Left ventricular remodeling was defined as an increase of the end-diastolic volume of ≥ 20% and/or a decrease of the ejection fraction of > 10%. Results Late gadolinium enhancement is an effective method to measure the infarct size. 77,70 % of the patients with left ventricular remodeling showed a infarct size larger than 20 % of the left ventricular mass. As one part of the study the patients were categorized into groups based on the results of the primary percutaneous coronary intervention (LAD: n= 26; RCA: n= 20; LCX: n = 8). After one year patients with anterior myocardial infarction had a lower ejection fraction, a significant increase of end-diastolic volume and a larger infarct size compared to the other infarct types. Nearly 50 % of the patients with remodeling had an occlusion of the RIVA. Microvascular obstruction is detectable in late gadolinium enhancement sequence and first pass perfusion. This study proved that the size of MO was 80 % smaller in LGE compared to FPP. Although the prognostic value of MO in LGE for the prediction of left ventricular remodeling seemed higher. This is caused by the fact, that LGE only shows severe microvascular obstruction, which is a greater risk to develop left ventricular remodeling. Patients with MO (= MO (+) (FPP: n= 42; LGE: n=27) presented lower ejection fraction (20 %), higher end-diastolic volume (24 %) and larger infarct size (170 %) compared to patients without IMH (= IMH (-)) on the follow-up CMR. Intramyocardial hemorrhage was observed in 29 patients (= IMH (+)), who showed lower ejection fraction (17%), higher end-diastolic volume (19 %) and larger infarct size (180 %) compared to patients without IMH (= IMH (-)) after one year. IMH was found in 72,15 % of patients with left ventricular remodeling. Conclusions Late gadolinium enhancement, microvascular obstruction and intramyocardial hemorrhage can be used to predict left ventricular remodeling in patients with myocardial infarction. In this study the presence of MO in the LGE sequence or the presence of IMH in a T2 imaging are the strongest predictors. KW - MRT KW - Myokardinfarkt KW - Late Gadolinium Enhancement KW - Mikrovaskuläre Obstruktion KW - intramyokardiale Einblutung Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-155782 ER - TY - JOUR A1 - Kosmala, Aleksander A1 - Gruschwitz, Philipp A1 - Veldhoen, Simon A1 - Weng, Andreas Max A1 - Krauss, Bernhard A1 - Bley, Thorsten Alexander A1 - Petritsch, Bernhard T1 - Dual-energy CT angiography in suspected pulmonary embolism: influence of injection protocols on image quality and perfused blood volume JF - The International Journal of Cardiovascular Imaging N2 - Abstract To compare intravenous contrast material (CM) injection protocols for dual-energy CT pulmonary angiography (CTPA) in patients with suspected acute pulmonary embolism with regard to image quality and pulmonary perfused blood volume (PBV) values. A total of 198 studies performed with four CM injection protocols varying in CM volume and iodine delivery rates (IDR) were retrospectively included: (A) 60 ml at 5 ml/s (IDR = 1.75gI/s), (B) 50 ml at 5 ml/s (IDR = 1.75gI/s), (C) 50 ml at 4 ml/s (IDR = 1.40gI/s), (D) 40 ml at 3 ml/s (IDR = 1.05gI/s). Image quality and PBV values at different resolution settings were compared. Pulmonary arterial tract attenuation was highest for protocol A (397 ± 110 HU; p vs. B = 0.13; vs. C = 0.02; vs. D < 0.001). CTPA image quality of protocol A was rated superior compared to protocols B and D by reader 1 (p = 0.01; < 0.001), and superior to protocols B, C and D by reader 2 (p < 0.001; 0.02; < 0.001). Otherwise, there were no significant differences in CTPA quality ratings. Subjective iodine map ratings did not vary significantly between protocols A, B, and C. Both readers rated protocol D inferior to all other protocols (p < 0.05). PBV values did not vary significantly between protocols A and B at resolution settings of 1, 4 and 10 (p = 0.10; 0.10; 0.09), while otherwise PBV values displayed a decreasing trend from protocol A to D (p < 0.05). Higher CM volume and IDR are associated with superior CTPA and iodine map quality and higher absolute PBV values. KW - CT KW - dual-energy CT KW - pulmonary embolism KW - contrast media Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-314739 SN - 1569-5794 SN - 1573-0743 VL - 36 IS - 10 ER - TY - GEN A1 - Kosmala, Aleksander A1 - Gruschwitz, Philipp A1 - Veldhoen, Simon A1 - Weng, Andreas Max A1 - Krauss, Bernhard A1 - Bley, Thorsten Alexander A1 - Petritsch, Bernhard T1 - Correction to: Dual-energy CT angiography in suspected pulmonary embolism: infuence of injection protocols on image quality and perfused blood volume T2 - The International Journal of Cardiovascular Imaging N2 - No abstract available. KW - correction Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-350830 VL - 38 IS - 3 SP - 707 ER - TY - THES A1 - Kortüm, Karsten Ulrich T1 - Beurteilung der regionalen Herzwandbewegung bei Probanden und Kardiomyopathiepatienten mit Friedreich Ataxie mittels hochaufgelöster MR‐Phasenkonstrastbildgebung T1 - Evaluation of regional heart movement of healthy volunteers and Friedreich's Ataxia patients suffering from cardiomyopathies using high-resolution MRI-phasecontrastimaging N2 - In der vorliegenden prospektiven experimentellen Studie wurden jeweils 18 Probanden sowie Patienten, die unter einer genetisch gesicherten Friedrich-­Ataxie leiden, mit der Tissue-­Phase‐Mapping (TPM) Sequenz im MRT untersucht. Mit der erwähnten Sequenz ist es möglich, die Geschwindigkeit der Herzwandbewegung über einen Herzzyklus zeitlich hoch aufgelöst (13,8 ms) darzustellen. Es wurde in der Vergangenheit gezeigt, dass die Daten der TPM‐Messung reproduzierbar sowie mit denen aus einer Ultraschalluntersuchung gewonnenen Daten vergleichbar sind. Die Aufnahme erfolgt unter freier Atmung in Navigatortechnik. Dadurch ist diese Untersuchung auch bei Patienten möglich, die aufgrund Ihrer Erkrankung sonst nicht ausreichend lange die Luft anhalten könnten. Die Friedreich‐Ataxie ist die häufigste aller Ataxien in der Adoleszenzphase und wird autosomal-­rezessiv vererbt. Neben neurologischen Ausfällen kann es auch zu einer kardialen Beteiligung kommen. Dabei zeigt sich bei einem großen Teil der Patienten eine Kardiomyopathie mit asymmetrischer septaler Hypertrophie sowie einer dynamischen linksventrikulären Ausflussobstruktion. Die American Heart Association klassifiziert dieses Krankeitsbild als sekundäre Kardiomyopathie neuromuskulären Ursprungs. Es wurde in der Vergangenheit bereits gezeigt, dass es unter einer Therapie mit dem Medikament Idebenone zu einer Verbesserung der kardialen Funktion kommen kann. Im Zusammenhang mit einer groß angelegten, multizentrischen Phase III Studie (MICONOS-­Studie) kamen diese Patienten nach Würzburg für eine MRT-­Untersuchung. Im Rahmen dessen erfolgte dann auf freiwilliger Basis eine Untersuchung mit der TPM-­Sequenz. Diese Substudie wurde von der lokalen Ethikkommission genehmigt und die Patienten wie auch Probanden haben selbst oder durch Erziehungsberechtigte der Untersuchung zugestimmt. Es konnte durch diese Arbeit gezeigt werden, dass zum einen die Methode des Tissue-­Phase‐Mappings erfolgreich am Institut für Röntgendiagnostik des Universitätsklinikums Würzburg eingeführt werden konnte. Zum anderen, dass die Ergebnisse der herzgesunden Probanden mit anderen, in der Vergangenheit durchgeführten Studien, ähnlich und vergleichbar sind. Zudem konnten teilweise signifikante Unterschiede der systolischen wie auch der diastolischen Geschwindigkeiten zwischen Probanden und Patienten der MICONOS Studie in einigen ROIs bzw. global nachgewiesen werden. Dies bedeutet, dass das hier vorgestellte Verfahren in der Lage ist, Unterschiede in den Geschwindigkeiten der regionalen wie auch globalen Herzwandbewegung in allen drei Bewegungsachsen zwischen verschiedenen Kollektiven zu detektieren. Diese Differenzen können ein Frühzeichen für eine pathologische Herzmuskelerkrankung sein und somit helfen, dass frühzeitig eine entsprechende Therapie begonnen wird. Aufgrund der Ergebnisse dieser Dissertation werden weitere Studien folgen, die helfen werden, dass das Tissue-­Phase‐Mapping Verfahren Einzug in die klinische Routine erhalten wird. N2 - In this study, we investigated 18 healthy volunteers as well as 18 patients suffering from Friedreich's Ataxia. The diagnosis of the disease was genetically confirmed. All subjects were examined using the Tissue-Phase-Mapping (TPM) sequence on MRI. This sequence delivers high spatial as well as high temporal (13,8 ms) resolution of local heart wall movements using navigator gated image acquisition in free-breathing. Firstly, we could show that this method could be successfully established at the "Institut für Röntgendiagnostik" of Würzburg for the first time with comparable results as in previous studies. Secondly, we found partly significant differences in local systolic and diastolic heart wall movements between volunteers and Friedreich's Ataxia patients. And lastly, we investigated, if there was a change in local heart wall velocities in Friedreich's patients in the course of time (7 month). KW - Friedreich-Ataxie KW - NMR-Tomographie KW - Herzmuskelkrankheit KW - TPM KW - Phasenkontrast KW - Herzwandbewegung KW - Tissue Phase Mapping KW - Friedreich's Ataxia KW - MRI KW - Phasecontrast Imaging KW - Tissue Phase Mapping KW - Cardiomyopathy Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-65769 ER - TY - JOUR A1 - Kollmann, Cathérine T. A1 - Pretzsch, Elise B. A1 - Kunz, Andreas A1 - Isbert, Christoph A1 - Krajinovic, Katica A1 - Reibetanz, Joachim A1 - Kim, Mia T1 - Anorectal angle at rest predicting successful sacral nerve stimulation in idiopathic fecal incontinence—a cohort analysis JF - International Journal of Colorectal Disease N2 - Purpose Sacral nerve stimulation is an effective treatment for patients suffering from fecal incontinence. However, less is knownabout predictors of success before stimulation. The purpose of this study was to identify predictors of successful sacral nervestimulation in patients with idiopathic fecal incontinence. Methods Consecutive female patients, receiving peripheral nerve evaluation and sacral nerve stimulation between September2008 and October 2014, suffering from idiopathic fecal incontinence were included in this study. Preoperative patient’scharac-teristics, anal manometry, and defecography results were collected prospectively and investigated by retrospective analysis. Mainoutcome measures were independent predictors of treatment success after sacral nerve stimulation. Results From, all in all, 54 patients suffering from idiopathic fecal incontinence receiving peripheral nerve evaluation, favorableoutcome was achieved in 23 of 30 patients after sacral nerve stimulation (per protocol 76.7%; intention to treat 42.6%). From allanalyzed characteristics, wide anorectal angle at rest in preoperative defecography was the only independent predictor offavorable outcome in multivariate analysis (favorable 134.1 ± 13.9° versus unfavorable 118.6 ± 17.1°). Conclusions Anorectal angle at rest in preoperative defecography might present a predictor of outcome after sacral nervestimulation in patients with idiopathic fecal incontinence. KW - sacral nerve stimulation KW - idiopathic fecal incontinence KW - sacral neuromodulation KW - anorectal angl Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-232379 SN - 0179-1958 VL - 35 ER - TY - THES A1 - Koeppe, Sabrina T1 - Diagnosefindung und Therapieevaluation bei Kardiomyopathien mittels Magnetresonanztomographie am Beispiel M. Fabry T1 - Diagnosis and therapy evaluation in cardiomyopathies with magnetic resonance tomography in Fabry disease N2 - Einführung M. Fabry ist eine x-chromosomal vererbte Enzymmangelerkrankung und führt zu progressiver Niereninsuffizienz und hypertropher Kardiomyopathie. Ziel dieser Studie war die Analyse der kardialen Veränderungen im Rahmen der Erkrankung und unter Enzymersatztherapie (ERT) mittels kontrastmittelgestützter Magnetresonanztomographie (MRT). Material und Methoden 25 Patienten (4 Frauen, Alter 18-55 Jahre) mit genetisch bestätigtem M. Fabry wurden vor und nach 12 Monaten ERT mit Fabrazyme® untersucht. Es erfolgte eine umfassende Analyse morphologischer und funktioneller Parameter des linken Ventrikels (LV) mit Fokussierung auf regionale Wandveränderungen sowie Late Enhancement (LE). Eine Gruppe von 43 gesunden Probanden diente als Kontrollgruppe. Ergebnisse Vor Therpiebeginn war bei 50% aller Patienten eine LV Hypertrophie mit erhöhter enddiastolischen Wanddicke (EDWT) nachweisbar. Die ERT führte zu einer Reduktion der EDWT und der LV Masse um 3,6 bis 10,3% innerhalb von 12 Monaten. Die initial erhöhten LV Volumina nahmen ebenfalls unter Therapie ab. Männliche Patienten wiesen eine eingeschränkte Ejektionsfraktion (EF) auf als Zeichen einer globalen Herzinsuffizienz, welche sich unter Therapie signifikant verbesserte. Die segmentale Analyse der systolischen Wanddickenzunahme (WT) zeigte teils ausgedehnte Wandbewegungsstörungen und eine Verbesserung der Kontraktilität unter ERT. Letztere war am stärksten ausgeprägt, wenn kein LE vorhanden war. Ein LE in der LV Seitenwand ist charakteristisch für M. Fabry und konnte bei 11 von 21 männlichen Patienten nachgewiesen werden mit einem Volumen von durchschnittlich 1,9 ± 1,8% der LV Masse. Das Ausmaß nahm häufig unter Therapie noch zu, es kam zu keiner Reduktion. Allerdings wurde auch kein Neuauftreten beobachtet. Frauen waren nicht betroffen. Das Alter LE-positiver Patienten lag etwa 10 Jahre über dem LE-negativer Patienten. Im Frauenkollektiv war die LV Hypertrophie geringer ausgeprägt als bei männlichen Patienten, lag aber dennoch über dem Normwert. Zwar war der Schweregrad der segmentalen Hypertrophie geringer, aber die regionale Verteilung war dennoch ähnlich der bei männlichen Patienten und blieb unter ERT auf hohem Niveau konstant. Auch die regionale Kontraktilität war mäßig beeinträchtigt und durchaus vergleichbar mit dem Ausmaß der Wandbewegungsstörungen bei LE-negativen männlichen Patienten. Bei Frauen war keine globale LV Insuffizienz nachweisbar. Dennoch belegen die erhöhte LV Wanddicke und segmentale Hypokinesien eine messbare kardiale Beeinträchtigung durch M. Fabry auch bei heterozygoten Patienten. Fazit Insgesamt erwies sich die MRT des Herzens als ideales Instrument zur strahlungsfreien Überwachung von Fabry Patienten unter ERT. So können bereits diskrete und regional beschränkte Veränderungen mit hoher Reliabilität diagnostiziert werden, auch in Regionen, die der Echokardiographie nur schwer zugänglich sind. Die LV Masse ist bereits in frühen Krankheitsstadien erhöht und korreliert gut mit der allgemeinen Erkrankungsschwere. Desweiteren impliziert die enge Verknüpfung zwischen Hypertrophie, erhöhten LV Volumina, Wandbewegungsstörungen und letztenendes globaler Herzinsuffizienz, dass die LV Hypertrophie einen wichtigen und früh sichtbaren Risikofaktor darstellt. Das LE als Zeichen der myokardialen Fibrose in späten Erkrankungsstadien ist irreversibel, ebenfalls eng verbunden mit der kardialen Funktion und scheint ein weiterer Risikofaktor zu sein für ein vermindertes Therapieansprechen. Mit dem Auftreten eines LE und zunehmenden LE-Scores erhöht sich die Wahrscheinlichkeit des Auftretens einer LV Hypertrophie und von Wandbewegungsstörungen. Das Patientenalter hatte keinen offensichtlichen Einfluss auf die Wirkung der ERT. Es gibt jedoch Hinweise auf eine Art „point of no return“, jenseits dessen der Therapieeffekt - zumindest das Herz betreffend - begrenzt zu sein scheint. N2 - Introduction Fabry disease is a x-chromosomal linked storage disorder and presents with renal failure and hypertrophic cardiomyopathy. The purpose of this study was to investigate cardiac alterations and treatment effects in Fabry patients undergoing enzyme replacement therapy (ERT) using contrast enhanced magnetic resonance imaging (MRI). Material and methods 25 patients (4 women, age 18-55 years) with genetically proven Fabry disease were examined prior to and after one year of ERT with Fabrazyme®. The analysis comprised morphologic and functional parameters of the heart with a focus on regional alterations and late enhancement (LE). A group of 43 healthy volunteers served as a control group. Results Before therapy, 50% of all patients presented with left ventricular (LV) hypertrophy and increased endiastolic wall thickness (EDWT). ERT led to a reduction of EDWT and LV mass of about 3.6 to 10.3% during 12 months. Initially increased LV volumes decreased under therapy as well. The ejection fraction (EF) in male patients was restricted as a sign of global heart failure and improved significantly under therapy. A segmental analysis of the systolic wall thickening (WT) revealed partly pronounced wall motion abnormalities declining under therapy. The improvement was most obvious if no LE was detectable. LE in the LV free wall is typical of Fabry disease and was found in 11 of 21 male patients with volumes of about 1.9 ± 1.8% of the LV mass. These volumes often increased significantly under ERT and no lesion reduced. No patient developed a new LE and no women were affected. The average age of patients with LE was about 10 years above that of LE negative patients. LV hypertrophy in female patients was minor to that of male patients but pathologically superior to normal values. Even if the segmental hypertrophy was less pronounced, the regional distribution was still comparable to that of male patients and remained stable on a high level. The regional contractility was also impaired moderately and was throughout comparable to the extent of wall motion abnormalities in LE negative men. No global dysfunction was detected in women. Nevertheless, increased LV wall thickness and segmental hypokinesia demonstrated a significant impairment of the cardiac system even in heterocygous patients. Conclusions After all, cardiac MRI is an ideal instrument for the monitoring of Fabry patients under ERT without radiation, which can detect already minor and regional restricted changes with high reliability and can assess even regions that are hard to examine by echocardiography. LV mass increases already in early stages of disease and correlates well with the severity of disease. Furthermore, the close connection between hypertrophy, increased LV volumes, wall motion abnormalities, and finally global function loss implicates that LV hypertrophy is an important risk factor. LE as a marker of myocardial fibrosis in later stages is irreversible and closely connected to functional cardiac parameters and therefore seems to be another risk factor for a worse outcome after therapy. In the presence of LE and the higher the LE scores, LV hypertrophy and wall motion abnormalities are more likely. The individual age did not influence therapy effects apparently. There are some arguments indicating a kind of ‘point of no return’. Beyond this point, the effects of ERT seemed to be restricted at least regarding the cardiac function. KW - Fabry-Krankheit KW - Funktionelle NMR-Tomographie KW - Hypertrophische Herzmuskelkrankheit KW - Funktionsanalyse KW - Fibrose KW - Herzmuskel KW - Late Enhancement KW - Delayed Enhancement KW - Fabry disease KW - cardiomyopathy KW - magnetic resonance imaging MRI KW - delayed enhancement KW - functional analysis Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-36009 ER - TY - THES A1 - Knödler, Pascal Alain T1 - Bestimmung der Altersabhängigkeit der Endothel-vermittelten Herzperfusion mittels MR Cold-Pressor-Test und Adenosin-Stress-Test T1 - Age-related comparison of myocardial perfusion imaging using MR cold pressor test and adenosine stress test N2 - In der vorliegenden Arbeit wurde die myokardiale Perfusion gesunder Probanden in Ruhe und unter Adenosin–induziertem, sowie Kälte-induziertem Stress quantitativ mittels First-Pass-Perfusions MR-Bildgebung beim gleichen Probanden untersucht und die Perfusionswerte alters- und geschlechtsabhängig verglichen. Hierbei wurden zwanzig Probanden in altersabhängige Gruppen eingeteilt, wobei der cut-off vierzig Jahre war. Diese Arbeit zeigt, dass der Einsatz des CPT zur Beurteilung der endothelvermittelten Vasodilatation im MRT möglich ist. Im Vergleich zum Einsatz von Adenosin zeigt die Stress-Untersuchung mittels CPT weniger bis keine unerwünschten Nebenwirkungen und die Kontraindikationen sind geringer. Somit ist der Einsatz des CPT zur Beurteilung der myokardialen Stressperfusion als eine nebenwirkungsarme Untersuchungsmodalität anzusehen, die es ermöglicht, die frühesten Veränderungen des Endothels bei beginnender koronarer Arteriosklerose zu detektieren. Als Ergebnis ist festzuhalten, dass in dieser Arbeit alle Probanden eine statistisch signifikante Perfusionserhöhung beim CPT aufweisen. Es zeigt sich kein statistisch signifikanter Alters- oder Geschlechtsunterschied beim CPT. Auf die Verabreichung von Adenosin reagiert die junge Probandengruppe mit einer statistisch signifikant höheren Myokardperfusion. Dies könnte in erster Linie durch den höheren Anteil an Frauen in der jungen Gruppe zu erklären sein. N2 - The response of myocardial blood flow (MBF) to adenosine stress and to sympathetic stimulation (Cold-Pressor-Test = CPT) with cold can be examined with the MRT. This work compares and evaluates a possible age and gender dependency of absolute myocardial perfusion values of stress MRT and MRT-CPT in the same healthy subjects divided into twogroups. First-Pass perfusion-studies were performed in 20 healthy, non-smoking volunteers, 10 with a mean age of 25±2.5yrs. and 10 with a mean age of 50.5±6.5yrs. using a 1.5 T MR-scanner with a multislice SSFP perfusion sequence in prebolus-technique. The MR-CPT was performed using a two minutes ice-water bath of the left hand. Second imaging was performed 15 minutes later to examine the perfusion at rest. In a further examination rest and adenosine stress perfusion was performed. The mean myocardial perfusion (cc/g/min) in the younger group rose from 0.77±0.13 at rest to 1.33±0.45 for CPT and from 0.76±0.16 at rest to 1.92±0.58 for adenosine stress. In the older group the myocardial perfusion rose from 0.81±0.16 at rest to 1.44±0.38 for CPT and from 0.71±0.16 at rest to 1.44±0.62 for adenosine stress. Perfusion values show a significant increase in both tests. A significant age or gender dependence was not found for the CPT. KW - NMR-Tomographie KW - Cold pressure test KW - Adenosin KW - Koronarperfusion KW - myocardial blood flow KW - sympathetic stimulation (CPT) KW - age dependency Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-71742 ER - TY - THES A1 - Knestel, Thomas T1 - Darstellung und Bewertung von interventionellen Drainagebehandlungen. Retrospektive Studie an 131 Patienten der Jahre 2001 bis 2003 T1 - Presentation and evaluation of interventional drainage-treatments. Retrospective study with 131 patients in the years 2001 to 2003 N2 - Die interventionelle radiologische Drainagenbehandlung ist heutzutage ein unverzichtbarer Bestandteil der modernen minimalinvasiven Therapie von Abszessen und infizierten Flüssigkeitsansammlungen. 180 Drainagebehandlungen an 131 Patienten der Chirurgischen Uniklinik Würzburg wurden im Zeitraum von Januar 2001 bis Juli 2003 untersucht. Es werden die beiden angewandten Verfahren der Seldinger- und Trokartechnik beschrieben und nach ihrem Erfolg bewertet. Dargestellt werden zunächst die rein technischen Ergebnisse der Punktionen. Danach werden die Behandlungen im Hinblick auf Erfolg und Misserfolg bewertet. Der Abszess wird bei der Behandlung unterschiedlicher Verhalte besonders berücksichtigt. Verglichen werden die Behandlungserfolge bei septischen Patienten mit denen bei nicht-septischen Patienten. Außerdem wird der Gesundheitszustand von intensivpflichtigen Patienten mithilfe des APACHE III-Scores bewertet. N2 - Today, interventional radiologic drainage therapy is an indispensable part of modern minimal- invasive therapy of abcesses and infected fluid collections. 180 treatments with drainage therapy in 131 patients of the surgical unit of the university wuerzburg from january 2001 to july 2003 have been analysed. The applied methods, trocar and the technique of seldinger are described and evaluated. First the pure technical results are presented. Then the therapies are evaluated by success or failure. Within the treatment of diverse fluid collections, especially, abscesses are regarded, followed by a comparison of successful therapy in patients with and without sepsis. Futhermore, patients of intensive care unit are stated with help of the APACHE III scoring system. KW - Abszess KW - Drainage KW - Interventionsradiologie KW - minimalinvasiv KW - perkutan KW - abscess KW - drainage-treatment Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-28829 ER - TY - THES A1 - Klinnert Vlachopoulou, Cristina Maria T1 - Comparison between Dual-Energy-CT perfusion imaging and perfusion-weighted SElf-gated Non-Contrast-Enhanced FUnctional MR imaging of the lung in patients with pulmonary artery embolism T1 - Vergleich zwischen Perfusionskarten der Lunge des DECT und "SElf-gated Non-Contrast-Enhanced Functional” MRT bei Patienten mit einer Lungenembolie N2 - Pulmonary artery embolism (PE) is a common condition and an even more common clinical suspect. The computed tomography pulmonary angiogram (CTPA) is the main medical imaging tool used to diagnose a suspected case of PE. To gain a better impression of the effects of a PE on the perfusion and hence the gas exchange, a functional imaging method is beneficial. One approach for functional imaging using radiation exposure is the generation of color-coded iodine perfusion maps acquired by Dual-Energy Computed Tomography (DECT), which enable the detection of perfusion defects in the pulmonary parenchyma. In contrast to the existing approach of DECT with iodine color-coded maps, the SElf-gated Non-Contrast-Enhanced FUnctional Lung (SENCEFUL) MRI technique offers the possibility to interpret perfusion maps without any radiation exposure or application of contrast agents. The measurement in SENCEFUL MRI can be performed during conditions of free breathing and without electrocardiogram triggering. The purpose of this study was to determine whether PE can be diagnosed on the basis of visible perfusion defects in the perfusion maps of SENCEFUL MRI and in the iodine-coded maps of DECT and to compare the diagnostic performance of these methods. Both SENCEFUL-MRI and iodine distribution maps from DECT have been compared with the CTPA of ten patients with PE. Additionally, the functional images were compared with each other on a per-patient basis. The iodine perfusion maps of DECT had a sensitivity of 84.2 % and specificity of 65.2 % for the diagnosis of PE. The SENCEFUL technique in MRI showed a sensitivity of 78.9 % and a specificity of 26.1 %. When comparing the whole lung depicted in both series of functional images, the main perfusion defect location matched in four of ten patients (40 %). In conclusion, this work found that DECT iodine maps have higher sensitivity and specificity in the diagnosis of pulmonary embolism compared with SENCEFUL MRI. N2 - Die Lungenembolie (LE) ist eine häufige Erkrankung und eine noch häufigere Verdachtsdiagnose. Die Computertomographie der Pulmonalarterien (CTPA) ist die Bildgebung erster Wahl für die Diagnose einer LE. Für eine bessere Darstellung der Folgen einer LE dienen Perfusionskarten. Eine existierende Bildgebungstechnik mit ionisierender Strahlung sind die Iodkarten der Dual-Energy-Computertomographie (DECT), welche bei einer LE Perfusionsdefekte im Lungenparenchym wiedergeben. Eine weitere strahlungsfreie und kontrastmittelfreie Methode ist die „SElf-gated Non-Contrast-Enhanced FUnctional Lung” (SENCEFUL) Magnet-Resonanz-Tomographie (MRT). Diese Technik kann ohne Atemhaltemanöver und ohne EKG-Monitoring stattfinden. Ziel der Arbeit war es zu bestimmen, ob eine LE aufgrund eines Perfusionsdefekts in den Iodkarten des DECT und SENCEFUL MRT diagnostiziert werden kann. Beide Bildgebungstechniken wurden mit der CTPA von zehn Patienten mit LE verglichen. Außerdem wurden die Perfusionsbilder untereinander verglichen. Die Iodkarten hatten eine Sensitivität von 84.2 % und eine Spezifizität von 65.2 %. Die SENCEFUL MRT Bilder zeigten eine Sensitivität von 78.9 % und eine Spezifizität von 26.1 %. Der Vergleich beider funktioneller Bildgebungstechniken bezogen auf die gesamte Lunge ergab, dass in vier von zehn Patienten die prädominierende Lokalisation der Minderperfusion übereinstimmte. Zusammenfassend konnte in dieser Arbeit festgestellt werden, dass die Iodkarten des DECTs im Vergleich zum SENCEFUL MRT eine höhere Sensitivität und Spezifizität in der Diagnose einer Lungenembolie aufweisen. KW - Lungenembolie KW - pulmonary embolism KW - perfusion map Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-313034 ER - TY - THES A1 - Kleineisel, Jonas T1 - Variational networks in magnetic resonance imaging - Application to spiral cardiac MRI and investigations on image quality T1 - Variational Networks in der Magnetresonanztomographie - Anwendung auf spirale Herzbildgebung und Untersuchungen zur Bildqualität N2 - Acceleration is a central aim of clinical and technical research in magnetic resonance imaging (MRI) today, with the potential to increase robustness, accessibility and patient comfort, reduce cost, and enable entirely new kinds of examinations. A key component in this endeavor is image reconstruction, as most modern approaches build on advanced signal and image processing. Here, deep learning (DL)-based methods have recently shown considerable potential, with numerous publications demonstrating benefits for MRI reconstruction. However, these methods often come at the cost of an increased risk for subtle yet critical errors. Therefore, the aim of this thesis is to advance DL-based MRI reconstruction, while ensuring high quality and fidelity with measured data. A network architecture specifically suited for this purpose is the variational network (VN). To investigate the benefits these can bring to non-Cartesian cardiac imaging, the first part presents an application of VNs, which were specifically adapted to the reconstruction of accelerated spiral acquisitions. The proposed method is compared to a segmented exam, a U-Net and a compressed sensing (CS) model using qualitative and quantitative measures. While the U-Net performed poorly, the VN as well as the CS reconstruction showed good output quality. In functional cardiac imaging, the proposed real-time method with VN reconstruction substantially accelerates examinations over the gold-standard, from over 10 to just 1 minute. Clinical parameters agreed on average. Generally in MRI reconstruction, the assessment of image quality is complex, in particular for modern non-linear methods. Therefore, advanced techniques for precise evaluation of quality were subsequently demonstrated. With two distinct methods, resolution and amplification or suppression of noise are quantified locally in each pixel of a reconstruction. Using these, local maps of resolution and noise in parallel imaging (GRAPPA), CS, U-Net and VN reconstructions were determined for MR images of the brain. In the tested images, GRAPPA delivers uniform and ideal resolution, but amplifies noise noticeably. The other methods adapt their behavior to image structure, where different levels of local blurring were observed at edges compared to homogeneous areas, and noise was suppressed except at edges. Overall, VNs were found to combine a number of advantageous properties, including a good trade-off between resolution and noise, fast reconstruction times, and high overall image quality and fidelity of the produced output. Therefore, this network architecture seems highly promising for MRI reconstruction. N2 - Eine Beschleunigung des Bildgebungsprozesses ist heute ein wichtiges Ziel von klinischer und technischer Forschung in der Magnetresonanztomographie (MRT). Dadurch könnten Robustheit, Verfügbarkeit und Patientenkomfort erhöht, Kosten gesenkt und ganz neue Arten von Untersuchungen möglich gemacht werden. Da sich die meisten modernen Ansätze hierfür auf eine fortgeschrittene Signal- und Bildverarbeitung stützen, ist die Bildrekonstruktion ein zentraler Baustein. In diesem Bereich haben Deep Learning (DL)-basierte Methoden in der jüngeren Vergangenheit bemerkenswertes Potenzial gezeigt und eine Vielzahl an Publikationen konnte deren Nutzen in der MRT-Rekonstruktion feststellen. Allerdings besteht dabei das Risiko von subtilen und doch kritischen Fehlern. Daher ist das Ziel dieser Arbeit, die DL-basierte MRT-Rekonstruktion weiterzuentwickeln, während gleichzeitig hohe Bildqualität und Treue der erzeugten Bilder mit den gemessenen Daten gewährleistet wird. Eine Netzwerkarchitektur, die dafür besonders geeignet ist, ist das Variational Network (VN). Um den Nutzen dieser Netzwerke für nicht-kartesische Herzbildgebung zu untersuchen, beschreibt der erste Teil dieser Arbeit eine Anwendung von VNs, welche spezifisch für die Rekonstruktion von beschleunigten Akquisitionen mit spiralen Auslesetrajektorien angepasst wurden. Die vorgeschlagene Methode wird mit einer segmentierten Rekonstruktion, einem U-Net, und einem Compressed Sensing (CS)-Modell anhand von qualitativen und quantitativen Metriken verglichen. Während das U-Net schlecht abschneidet, zeigen die VN- und CS-Methoden eine gute Bildqualität. In der funktionalen Herzbildgebung beschleunigt die vorgeschlagene Echtzeit-Methode mit VN-Rekonstruktion die Aufnahme gegenüber dem Goldstandard wesentlich, von etwa zehn zu nur einer Minute. Klinische Parameter stimmen im Mittel überein. Die Bewertung von Bildqualität in der MRT-Rekonstruktion ist im Allgemeinen komplex, vor allem für moderne, nichtlineare Methoden. Daher wurden anschließend forgeschrittene Techniken zur präsizen Analyse von Bildqualität demonstriert. Mit zwei separaten Methoden wurde einerseits die Auflösung und andererseits die Verstärkung oder Unterdrückung von Rauschen in jedem Pixel eines untersuchten Bildes lokal quantifiziert. Damit wurden lokale Karten von Auflösung und Rauschen in Rekonstruktionen durch Parallele Bildgebung (GRAPPA), CS, U-Net und VN für MR-Aufnahmen des Gehirns berechnet. In den untersuchten Bildern zeigte GRAPPA gleichmäßig eine ideale Auflösung, aber merkliche Rauschverstärkung. Die anderen Methoden verhalten sich lokal unterschiedlich je nach Struktur des untersuchten Bildes. Die gemessene lokale Unschärfe unterschied sich an den Kanten gegenüber homogenen Bildbereichen, und Rauschen wurde überall außer an Kanten unterdrückt. Insgesamt wurde für VNs eine Kombination von verschiedenen günstigen Eigenschaften festgestellt, unter anderem ein guter Kompromiss zwischen Auflösung und Rauschen, schnelle Laufzeit, und hohe Qualität und Datentreue der erzeugten Bilder. Daher erscheint diese Netzwerkarchitektur als ein äußerst vielversprechender Ansatz für MRT-Rekonstruktion. KW - Kernspintomografie KW - Convolutional Neural Network KW - Maschinelles Lernen KW - Bildgebendes Verfahren KW - magnetic resonance imaging KW - convolutional neural network KW - variational network KW - cardiac imaging KW - machine learning KW - local point-spread function KW - resolution KW - g-factor Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-347370 ER -