TY - JOUR A1 - Schuster, Frank A1 - Wessig, Carsten A1 - Schimmer, Christoph A1 - Johannsen, Stephan A1 - Lazarus, Marc A1 - Aleksic, Ivan A1 - Leyh, Rainer A1 - Roewer, Norbert T1 - In vitro contracture test results and anaesthetic management of a patient with emery-dreifuss muscular dystrophy for cardiac transplantation JF - Case Reports in Anesthesiology N2 - Emery-Dreifuss muscular dystrophy (EDMD) is a hereditary neuromuscular disorder characterized by slowly progressive muscle weakness, early contractures, and dilated cardiomyopathy. We reported an uneventful general anaesthesia using total intravenous anaesthesia (TIVA) for cardiac transplantation in a 19-year-old woman suffering from EDMD. In vitro contracture test results of two pectoralis major muscle bundles of the patient suggest that exposition to triggering agents does not induce a pathological sarcoplasmic calcium release in the lamin A/C phenotype. However, due to the lack of evidence in the literature, we would recommend TIVA for patients with EDMD if general anaesthesia is required. KW - Emery-Dreifuss muscular dystrophy Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-123413 VL - 2012 IS - 349046 ER - TY - JOUR A1 - Gassenmaier, Tobias A1 - Gorski, Armin A1 - Aleksic, Ivan A1 - Deubner, Nikolas A1 - Weidemann, Frank A1 - Beer, Meinrad T1 - Impact of cardiac magnet resonance imaging on management of ventricular septal rupture after acute myocardial infarction JF - World Journal of Cardiology N2 - A 74-year-old man was admitted to the cardiac catheterization laboratory with acute myocardial infarction. After successful angioplasty and stent implantation into the right coronary artery, he developed cardiogenic shock the following day. Echocardiography showed ventricular septal rupture. Cardiac magnet resonance imaging (MRI) was performed on the critically ill patient and provided detailed information on size and localization of the ruptured septum by the use of fast MRI sequences. Moreover, the MRI revealed that the ventricular septal rupture was within the myocardial infarction area, which was substantially larger than the rupture. As the patient’s condition worsened, he was intubated and had intra-aortic balloon pump implanted, and extracorporeal membrane oxygenation was initiated. During the following days, the patient’s situation improved, and surgical correction of the ventricular septal defect could successfully be performed. To the best of our knowledge, this case report is the first description of postinfarction ventricular septal rupture by the use of cardiac MRI in an intensive care patient with cardiogenic shock and subsequent successful surgical repair. KW - Cardiac magnetic resonance imaging KW - Ventricular septal rupture KW - Myocardial infarction KW - surgical repair KW - Extracorporeal membrane oxygenation Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-96562 ER - TY - JOUR A1 - Penov, Kiril A1 - Radakovic, Dejan A1 - Madrahimov, Nodir A1 - Aleksic, Ivan T1 - Subacute Aortic Rupture Due to Mechanical Chest Compression with Indwelling Impella JF - The Thoracic and Cardiovascular Surgeon Reports N2 - Mechanical cardiopulmonary resuscitation (CPR) devices like Lund University Cardiopulmonary Assist System (LUCAS) cause more skeletal and visceral injuries than standard CPR. A 62-year-old woman with ST-elevation myocardial infarction was resuscitated with LUCAS and Impella CP for refractory cardiogenic shock during percutaneous coronary intervention. She suffered delayed ascending aortic rupture necessitating supracommissural ascending aortic replacement plus triple bypass grafting. Prolonged mechanical CPR with concomitant Impella may lead to aortic rupture. The combined use of LUCAS and Impella may have disastrous consequences. KW - cardiac catheterization/ intervention KW - shock (systemic, cardiac or circulatory) KW - circulatory assist devices Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300174 SN - 2194-7635 VL - 11 IS - 1 SP - e64 EP - e66 ER - TY - JOUR A1 - Bening, Constanze A1 - Hamouda, Khaled A1 - Oezkur, Mehmet A1 - Schimmer, Christoph A1 - Schade, Ina A1 - Gorski, Armin A1 - Aleksic, Ivan A1 - Leyh, Rainer T1 - Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior minithoracotomy JF - Journal of Cardiothoracic Surgery N2 - Background: There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT. Methods: Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted. Results: Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23–27 mm vs. 23 mm; IQR 21–25; p = 0.009). Conclusions: Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings. KW - aortic valve replacement KW - minimally invasive surgery KW - heart valve prosthesis KW - biological rapid deployment aortic valve Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159439 VL - 12 IS - 27 ER - TY - JOUR A1 - Sayed, Sameh A1 - Schimmer, Christoph A1 - Shade, Ina A1 - Leyh, Rainer A1 - Aleksic, Ivan T1 - Combined pulmonary and left ventricular support with veno-pulmonary ECMO and impella 5.0 for cardiogenic shock after coronary surgery JF - Journal of Cardiothoracic Surgery N2 - Background: Mechanical circulatory support is a common practice nowadays in the management of patients after cardiogenic shock due to myocardial infarction. The single or combined use of one or more devices for mechanical support depends not only on the advantage or disadvantage of these devices but also on the timing of use of these devices before the development of multi organ failure. In our case we used more than one tool for mechanical circulatory support during the prolonged and complicated course of our patient with postcardiotomy cardiogenic shock after coronary artery bypass surgery. Case Presentation: We describe the combined use of Impella 5.0 and veno- pulmonary extra corporeal membrane oxygenation (VP-ECMO) for biventricular failure in a 52 years—old man. He presented with cardiogenic shock after inferior wall ST-elevation myocardial infarction. After emergency coronary artery bypass surgery and failure to wean from extracorporeal circulation we employed V-P ECMO and consecutively Impella 5.0 to manage the primarily failing right and secondarily failing left ventricles. He remained hemodynamically stable on both Impella 5.0 and VP-ECMO until Heart Mate II left ventricular assist device implantation on the 14th postoperative day. Right sided support was weaned on 66th postoperative day. The patient remained in the intensive care unit for 77 days. During his prolonged stay, he underwent renal replacement therapy and tracheostomy with complete recovery. Six months later, he was successfully heart transplanted and has completed three and half years of unremarkable follow up. Conclusions: The combined use of VP ECMO and Impella 5.0 is effective in the management of postcardiotomy biventricular failure as a bridge for further mechanical support or heart transplantation. KW - cardiogenic shock KW - extra corporeal membrane oxygenator KW - impella 5.0 Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-157598 VL - 12 IS - 38 ER - TY - JOUR A1 - Radakovic, Dejan A1 - Penov, Kiril A1 - Hamouda, Khaled A1 - Madrahimov, Nodir A1 - Radakovic, Darko A1 - Bening, Constanze A1 - Leyh, Rainer G. A1 - Aleksic, Ivan T1 - Benefits of intra-aortic balloon pump support in patients with postcardiotomy shock requiring venoarterial extracorporeal membrane oxygenation JF - Life N2 - Background: The benefit of the combined use of an intra-aortic balloon pump (IABP) and venoarterial extracorporeal membrane oxygenation (VA-ECMO) for postcardiotomy shock remains unclear. We aimed to analyse the potential benefits and safety of combining these two devices. Methods: We enrolled 200 patients treated with either VA-ECMO only or in combination with IABP (ECMO-I group) between January 2012 and January 2021. To adjust the patients’ backgrounds, we used propensity score matching for additional analyses, resulting in 57 pairs. The primary endpoint was 30-day survival. Secondary endpoints included successful weaning and complication rates. We also analysed hemodynamic parameters in both groups. Results: After propensity score matching, 30-day survival was better in the ECMO-I group (log-rank p = 0.004). The ECMO-I and ECMO-only groups differed regarding the secondary endpoints, including successful weaning (50.9% and 26.3%, respectively; p = 0.012) and the need for continuous renal replacement therapy (28.1% and 50.9%, p = 0.021). Complication rates were not statistically different between the two groups. Conclusion: Compared to VA-ECMO alone, the combined use of VA-ECMO and IABP is beneficial regarding 30-day survival in selected patients with postcardiotomy shock; successful ECMO weaning and freedom from renal replacement therapy is more common in patients supported with VA-ECMO plus IABP. KW - postcardiotomy shock KW - VA-ECMO KW - IABP Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-286241 SN - 2075-1729 VL - 12 IS - 8 ER -