TY - JOUR A1 - Baur, Johannes A1 - Ritter, Christian O. A1 - Germer, Christoph-Thomas A1 - Klein, Ingo A1 - Kickuth, Ralph A1 - Steger, Ulrich T1 - Transarterial chemoembolization with drug-eluting beads versus conventional transarterial chemoembolization in locally advanced hepatocellular carcinoma JF - Hepatic Medicine N2 - Purpose: In hepatocellular carcinoma patients with large or multinodal tumors, where curative treatment options are not feasible, transarterial therapies play a major role. Transarterial chemoembolization (TACE) with drug-eluting beads (DEB-TACE) is a promising new approach due to higher intratumoral and lower systemic concentration of the chemotherapeutic agent compared to conventional TACE (cTACE). Patients and methods: In a retrospective analysis, 32 patients with hepatocellular carcinoma who received either DEB or a cTACE were compared regarding survival time, disease recurrence, and side effects such as pain and fever. Results: No significant differences could be detected between the cTACE and DEB-TACE groups with regard to mean hospital stay, appearance of postinterventional fever, or 30-day mortality. However, the application of intravenous analgesics as postinterventional pain medication was needed more often in patients treated with DEB-TACE (57.1% vs 12.5%, P=0.0281). The overall median survival after the initial procedure was 10.8 months in the cTACE group and 9.2 months in the DEB-TACE group, showing no significant difference. Conclusion: No survival benefit for patients treated with either DEB-TACE or cTACE was observed. Surprisingly, a higher rate of postinterventional pain could be detected after DEB-TACE. KW - transarterial chemoembolization KW - hepatocellular carcinoma KW - drug-eluting beads Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-146553 VL - 2016 IS - 8 ER - TY - JOUR A1 - Baur, Johannes A1 - Schedelbeck, Ulla A1 - Pulzer, Alina A1 - Bluemel, Christina A1 - Wild, Vanessa A1 - Fassnacht, Martin A1 - Steger, U. T1 - A case report of a solitary pancreatic metastasis of an adrenocortical carcinoma JF - BMC Surgery N2 - Background Solitary metastases to the pancreas are rare. Therefore the value of resection in curative intention remains unclear. In the literature there are several promising reports about resection of solitary metastasis to the pancreas mainly of renal origin. Case presentation Here we report for the first time on the surgical therapy of a 1.5 cm solitary pancreatic metastasis of an adrenocortical carcinoma. The metastasis occurred almost 6 years after resection of the primary tumor. A partial pancreatoduodenectomy was performed and postoperatively adjuvant mitotane treatment was initiated. During the follow-up of 3 years after surgery no evidence of tumor recurrence occurred. Conclusion Resection of pancreatic tumors should be considered, even if the mass is suspicious for metastatic disease including recurrence of adrenocortical cancer. KW - surgical treatment KW - adrenocortical KW - carcinoma metastases to pancreas Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126130 VL - 15 IS - 93 ER - TY - JOUR A1 - Dietz, Ulrich A. A1 - Kudsi, O. Yusef A1 - Garcia-Ureña, Miguel A1 - Baur, Johannes A1 - Ramser, Michaela A1 - Maksimovic, Sladjana A1 - Keller, Nicola A1 - Dörfer, Jörg A1 - Eisner, Lukas A1 - Wiegering, Armin T1 - Robotische Hernienchirurgie III: Robotische Inzisionalhernienversorgung mit „transversus abdominis release“ (r-TAR). Videobeitrag und Ergebnisse einer Kohortenstudie JF - Der Chirurg N2 - Das Prinzip der gezielten Trennung bzw. Schwächung einzelner Komponenten der Bauchdecke zur Spannungsentlastung der Medianlinie bei großen abdominellen Rekonstruktionen ist seit über 30 Jahren als anteriore Komponentenseparation (aKS) bekannt und ein etabliertes Verfahren. Auf der Suche nach Alternativen mit geringerer Komplikationsrate wurde die posteriore Komponentenseparation (pKS) entwickelt; der „transversus abdominis release“ (TAR) ist eine nervenschonende Modifikation der pKS. Mit den ergonomischen Ressourcen der Robotik (z. B. abgewinkelte Instrumente) kann der TAR minimal-invasiv durchgeführt werden (r-TAR): Bruchlücken von bis zu 14 cm lassen sich verschließen und ein großes extraperitoneales Netz implantieren. In diesem Videobeitrag wird die Versorgung großer Inzisionalhernien in der r‑TAR-Technik präsentiert. Exemplarisch werden die Ergebnisse einer Kohortenstudie an 13 konsekutiven Patienten vorgestellt. Der Eingriff ist anspruchsvoll, die eigenen Ergebnisse sind – wie auch die Berichte aus der Literatur – ermutigend. Der r‑TAR entwickelt sich zur Königsdisziplin der Bauchdeckenrekonstruktion. KW - posteriore Komponentenseparation KW - Robotik KW - inzisionale Hernie KW - ventrale Hernie KW - retromuskuläres Netz Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-265172 VL - 92 IS - 10 ER - TY - JOUR A1 - Baur, Johannes A1 - Büntemeyer, Tjark-Ole A1 - Megerle, Felix A1 - Deutschbein, Timo A1 - Spitzweg, Christine A1 - Quinkler, Marcus A1 - Nawroth, Peter A1 - Kroiss, Matthias A1 - Germer, Christoph-Thomas A1 - Fassnacht, Martin A1 - Steger, Ulrich T1 - Outcome after resection of Adrenocortical Carcinoma liver metastases: a retrospective study JF - BMC Cancer N2 - Background: Metastatic Adrenocortical Carcinoma (ACC) is a rare malignancy with a poor 5-year-survival rate (<15%). A surgical approach is recommended in selected patients if complete resection of distant metastasis can be achieved. To date there are only limited data on the outcome after surgical resection of hepatic metastases of ACC. Methods: A retrospective analysis of the German Adrenocortical Carcinoma Registry was conducted. Patients with liver metastases of ACC but without extrahepatic metastases or incomplete tumour resection were included. Results: Seventy-seven patients fulfilled these criteria. Forty-three patients underwent resection of liver metastases of ACC. Complete tumour resection (R0) could be achieved in 30 (69.8%). Median overall survival after liver resection was 76.1 months in comparison to 10.1 months in the 34 remaining patients with unresected liver metastases (p < 0.001). However, disease free survival after liver resection was only 9.1 months. Neither resection status (R0/R1) nor extent of liver resection were significant predictive factors for overall survival. Patients with a time interval to the first metastasis/recurrence (TTFR) of greater than 12 months or solitary liver metastases showed significantly prolonged survival. Conclusions: Liver resection in the case of ACC liver metastases can achieve long term survival with a median overall survival of more than 5 years, but disease free survival is short despite metastasectomy. Time to recurrence and single versus multiple metastases are predictive factors for the outcome. KW - Adrenocortical Carcinoma KW - liver resection KW - retrospective study KW - prognosis KW - survival analysis Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-159409 VL - 17 IS - 522 ER - TY - JOUR A1 - Kress, Sebastian A1 - Baur, Johannes A1 - Otto, Christoph A1 - Burkard, Natalie A1 - Braspenning, Joris A1 - Walles, Heike A1 - Nickel, Joachim A1 - Metzger, Marco T1 - Evaluation of a miniaturized biologically vascularized scaffold in vitro and in vivo JF - Scientific Reports N2 - In tissue engineering, the generation and functional maintenance of dense voluminous tissues is mainly restricted due to insufficient nutrient supply. Larger three-dimensional constructs, which exceed the nutrient diffusion limit become necrotic and/or apoptotic in long-term culture if not provided with an appropriate vascularization. Here, we established protocols for the generation of a pre-vascularized biological scaffold with intact arterio-venous capillary loops from rat intestine, which is decellularized under preservation of the feeding and draining vascular tree. Vessel integrity was proven by marker expression, media/blood reflow and endothelial LDL uptake. In vitro maintenance persisted up to 7 weeks in a bioreactor system allowing a stepwise reconstruction of fully vascularized human tissues and successful in vivo implantation for up to 4 weeks, although with time-dependent decrease of cell viability. The vascularization of the construct lead to a 1.5× increase in cellular drug release compared to a conventional static culture in vitro. For the first time, we performed proof-of-concept studies demonstrating that 3D tissues can be maintained within a miniaturized vascularized scaffold in vitro and successfully implanted after re-anastomosis to the intrinsic blood circulation in vivo. We hypothesize that this technology could serve as a powerful platform technology in tissue engineering and regenerative medicine. KW - biological models KW - translational research Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176343 VL - 8 IS - 4719 ER - TY - JOUR A1 - Wiegering, Armin A1 - Riegel, Johannes A1 - Wagner, Johanna A1 - Kunzmann, Volker A1 - Baur, Johannes A1 - Walles, Thorsten A1 - Dietz, Ulrich A1 - Loeb, Stefan A1 - Germer, Christoph-Thomas A1 - Steger, Ulrich A1 - Klein, Ingo T1 - The impact of pulmonary metastasectomy in patients with previously resected colorectal cancer liver metastases JF - PLoS ONE N2 - Background 40–50% of patients with colorectal cancer (CRC) will develop liver metastases (CRLM) during the course of the disease. One third of these patients will additionally develop pulmonary metastases. Methods 137 consecutive patients with CRLM, were analyzed regarding survival data, clinical, histological data and treatment. Results were stratified according to the occurrence of pulmonary metastases and metastases resection. Results 39% of all patients with liver resection due to CRLM developed additional lung metastases. 44% of these patients underwent subsequent pulmonary resection. Patients undergoing pulmonary metastasectomy showed a significantly better five-year survival compared to patients not qualified for curative resection (5-year survival 71.2% vs. 28.0%; p = 0.001). Interestingly, the 5-year survival of these patients was even superior to all patients with CRLM, who did not develop pulmonary metastases (77.5% vs. 63.5%; p = 0.015). Patients, whose pulmonary metastases were not resected, were more likely to redevelop liver metastases (50.0% vs 78.6%; p = 0.034). However, the rate of distant metastases did not differ between both groups (54.5 vs.53.6; p = 0.945). Conclusion The occurrence of colorectal lung metastases after curative liver resection does not impact patient survival if pulmonary metastasectomy is feasible. Those patients clearly benefit from repeated resections of the liver and the lung metastases. KW - hepatic resection KW - surgical resection KW - lung resection KW - curative resection KW - metastasis KW - colorectal cancer KW - cancer treatment KW - surgical oncology Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158036 VL - 12 IS - 3 ER - TY - JOUR A1 - Baur, Johannes A1 - Ramser, Michaela A1 - Keller, Nicola A1 - Muysoms, Filip A1 - Dörfer, Jörg A1 - Wiegering, Armin A1 - Eisner, Lukas A1 - Dietz, Ulrich A. T1 - Robotische Hernienchirurgie II: Robotische primär ventrale und inzisionale Hernienversorgung (rv-TAPP und r-Rives/r-TARUP). Videobeitrag und Ergebnisse einer Kohortenstudie an 118 Patienten JF - Der Chirurg N2 - Die endoskopische Versorgung von Umbilikal- und Inzisionalhernien hat sich in den vergangenen 30 Jahren an die Limitationen der konventionellen laparoskopischen Instrumente angepasst. Dazu gehört die Entwicklung von Netzen für die intraperitoneale Lage (intraperitoneales Onlay-Mesh, IPOM) mit antiadhäsiven Beschichtungen; allerdings kommt es bei einem beträchtlichen Teil dieser Patienten doch zu Adhäsionen. Minimal-invasive Verfahren führen zu weniger perioperativen Komplikationen, bei einer etwas höheren Rezidivrate. Mit den ergonomischen Ressourcen der Robotik, die abgewinkelte Instrumente anbietet, besteht erstmals die Möglichkeit, Netze minimal-invasiv in unterschiedliche Bauchdeckenschichten zu implantieren und gleichzeitig eine morphologische und funktionelle Rekonstruktion der Bauchdecke zu erreichen. In diesem Videobeitrag wird die Versorgung von Ventral- und Inzisionalhernien mit Netzimplantation in den präperitonealen Raum (robotische ventrale transabdominelle präperitoneale Patchplastik, rv-TAPP) sowie in den retrorektalen Raum (r-Rives bzw. robotische transabdominelle retromuskuläre umbilikale Patchplastik [r-TARUP]) präsentiert. Es werden die Ergebnisse einer Kohortenstudie an 118 konsekutiven Patienten vorgestellt und im Hinblick auf den Mehrwert der robotischen Technik in der Extraperitonealisierung der Netze und in der Weiterbildung diskutiert. KW - retrorektus Netz KW - Umbilikalhernie KW - Inzisionalhernie KW - primär ventrale Hernie KW - minimalinvasiv KW - linea alba Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-264912 VL - 92 IS - 9 ER - TY - JOUR A1 - Ramser, Michaela A1 - Baur, Johannes A1 - Keller, Nicola A1 - Kukleta, Jan F. A1 - Dörfer, Jörg A1 - Wiegering, Armin A1 - Eisner, Lukas A1 - Dietz, Ulrich A. T1 - Robotische Hernienchirurgie I: Robotische Leistenhernienversorgung (r‑TAPP). Videobeitrag und Ergebnisse einer Kohortenstudie an 302 operierten Hernien JF - Der Chirurg N2 - Die Versorgung von Leistenhernien mit offenen und minimal-invasiven Verfahren hat in den vergangenen 30 Jahren einen vom Ergebnis her gesehen hohen Standard erreicht. Allerdings besteht noch Bedarf an einer weiteren Reduktion der postoperativen Serome, chronischen Schmerzen und des Rezidivs. In diesem Videobeitrag wird die endoskopische Anatomie der Leiste im Hinblick auf die robotische transabdominelle präperitoneale Patchplastik (r‑TAPP) dargestellt und die Operationsschritte der r‑TAPP als Video illustriert. Es werden die Ergebnisse einer Kohortenstudie an 302 konsekutiven Hernien, die mittels r‑TAPP operiert wurden, vorgestellt und hinsichtlich des Mehrwerts der robotischen Technik – auch in der Weiterbildung – diskutiert. Die r‑TAPP ist die natürliche Weiterentwicklung der konventionellen TAPP und hat das Potenzial, bei zunehmender Geräteverfügbarkeit und Reduktion der Materialkosten zu einem neuen Standard zu werden. Künftige Studien werden den vielseitigen Mehrwert der r‑TAPP auch mit neuen Parametern verfeinern müssen. KW - robotische Leistenhernienversorgung KW - r-TAPP Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-264883 VL - 92 IS - 8 ER - TY - JOUR A1 - Pelz, Jörg O. W. A1 - Wagner, Johanna A1 - Lichthardt, Sven A1 - Baur, Johannes A1 - Kastner, Caroline A1 - Matthes, Niels A1 - Germer, Christoph-Thomas A1 - Wiegering, Armin T1 - Laparoscopic right-sided colon resection for colon cancer - has the control group so far been chosen correctly? JF - World Journal of Surgical Oncology N2 - Background: The treatment strategies for colorectal cancer located in the right side of the colon have changed dramatically during the last decade. Due to the introduction of complete mesocolic excision (CME) with central ligation of the vessels and systematic lymph node dissection, the long-term survival of affected patients has increased significantly. It has also been proposed that right-sided colon resection can be performed laparoscopically with the same extent of resection and equal long-term results. Methods: A retrospective evaluation of a prospectively expanded database on right-sided colorectal cancer or adenoma treated at the University Hospital of Wuerzburg between 2009 and 2016 was performed. All patients underwent CME. This data was analyzed alone and in comparison to the published data describing laparoscopic right-sided colon resection for colon cancer. Results: The database contains 279 patients, who underwent right-sided colon resection due to colorectal cancer or colorectal adenoma (255 open; 24 laparoscopic). Operation data (time, length of stay, time on ICU) was equal or superior to laparoscopy, which is comparable to the published results. Surprisingly, the surrogate parameter for correct CME (the number of removed lymph nodes) was significantly higher in the open group. In a subgroup analysis only including patients who were feasible for laparoscopic resection and had been operated with an open procedure by an experienced surgeon, operation time was significantly shorter and the number of removed lymph nodes is significantly higher in the open group. Conclusion: So far, several studies demonstrate that laparoscopic right-sided colon resection is comparable to open resection. Our data suggests that a consequent CME during an open operation leads to significantly more removed lymph nodes than in laparoscopically resected patients and in several so far published data of open control groups from Europe. Further prospective randomized trials comparing the long-term outcome are urgently needed before laparoscopy for right-sided colon resection can be recommended ubiquitously. KW - colon cancer KW - laparoscopic right colectomy KW - lymph nodes Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176186 VL - 16 IS - 117 ER - TY - JOUR A1 - Baur, Johannes A1 - Mathe, Katrin A1 - Gesierich, Anja A1 - Weyandt, Gerhard A1 - Wiegering, Armin A1 - Germer, Christoph-Thomas A1 - Gasser, Martin A1 - Pelz, Jörg O. W. T1 - Morbidity and oncologic outcome after saphenous vein-sparing inguinal lymphadenectomy in melanoma patients JF - World Journal of Surgical Oncology N2 - Background: Inguinal lymph node dissection (LND) is a surgical procedure with a high morbidity rate. Variations in surgical procedure, such as sparing of the saphenous vein, have been proposed to reduce surgical morbidity. While sparing of the saphenous vein has shown promising results in earlier studies, data for this procedure in melanoma patients are rare. In this retrospective study, we report 10-year findings on the effects of saphenous vein-sparing LND on surgical morbidity and oncologic outcomes in melanoma patients. Methods: A retrospective analysis of melanoma patients receiving inguinal LND in our facility between 2003 and 2013 was performed. Patients were divided into two groups: the saphenous vein resection group and the vein sparing group. Surgical morbidity, including wound infection, lymphatic fistula, severe bleeding, neurological complications, and chronic lymphedema, as well as regional recurrence-free survival were investigated. Results: A total of 106 patients were included in this study; of these, the saphenous vein was spared in 41 patients (38.7%). The rate of lymphatic fistula was 51.6 vs. 48.8%, wound infection occurred in 31.3 vs. 24.4%, and patients suffered from chronic lymphedema in 30.0 vs. 26.5% in V. saphena magna resection vs. sparing group. Differences observed, however, were not significant. No difference in regional recurrence-free survival between the two study groups was detected. Conclusions: The results of our retrospective analysis could not confirm the promising results reported in earlier studies. Thus, sparing of the saphenous vein appears to be optional. KW - malignant melanoma KW - inguinal lymph node dissection KW - regional recurrence KW - V. saphena magna Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-157687 VL - 15 IS - 99 ER - TY - JOUR A1 - Baur, Johannes A1 - Ramser, Michaela A1 - Keller, Nicola A1 - Muysoms, Filip A1 - Dörfer, Jörg A1 - Wiegering, Armin A1 - Eisner, Lukas A1 - Dietz, Ulrich A. T1 - Robotic hernia repair II. English version BT - Robotic primary ventral and incisional hernia repair (rv‑TAPP and r‑Rives or r‑TARUP). Video report and results of a series of 118 patients JF - Der Chirurg N2 - Endoscopic management of umbilical and incisional hernias has adapted to the limitations of conventional laparoscopic instruments over the past 30 years. This includes the development of meshes for intraperitoneal placement (intraperitoneal onlay mesh, IPOM), with antiadhesive coatings; however, adhesions do occur in a significant proportion of these patients. Minimally invasive procedures result in fewer perioperative complications, but with a slightly higher recurrence rate. With the ergonomic resources of robotics, which offers angled instruments, it is now possible to implant meshes in a minimally invasively manner in different abdominal wall layers while achieving morphologic and functional reconstruction of the abdominal wall. This video article presents the treatment of ventral and incisional hernias with mesh implantation into the preperitoneal space (robot-assisted transabdominal preperitoneal ventral hernia repair, r‑ventral TAPP) as well as into the retrorectus space (r-Rives and robotic transabdominal retromuscular umbilical prosthetic repair, r‑TARUP, respectively). The results of a cohort study of 118 consecutive patients are presented and discussed with regard to the added value of the robotic technique in extraperitoneal mesh implantation and in the training of residents. N2 - Die endoskopische Versorgung von Umbilikal- und Inzisionalhernien hat sich in den vergangenen 30 Jahren an die Limitationen der konventionellen laparoskopischen Instrumente angepasst. Dazu gehört die Entwicklung von Netzen für die intraperitoneale Lage (intraperitoneales Onlay-Mesh, IPOM) mit antiadhäsiven Beschichtungen; allerdings kommt es bei einem beträchtlichen Teil dieser Patienten doch zu Adhäsionen. Minimal-invasive Verfahren führen zu weniger perioperativen Komplikationen, bei einer etwas höheren Rezidivrate. Mit den ergonomischen Ressourcen der Robotik, die abgewinkelte Instrumente anbietet, besteht erstmals die Möglichkeit, Netze minimal-invasiv in unterschiedliche Bauchdeckenschichten zu implantieren und gleichzeitig eine morphologische und funktionelle Rekonstruktion der Bauchdecke zu erreichen. In diesem Videobeitrag wird die Versorgung von Ventral- und Inzisionalhernien mit Netzimplantation in den präperitonealen Raum (robotische ventrale transabdominelle präperitoneale Patchplastik, rv-TAPP) sowie in den retrorektalen Raum (r-Rives bzw. robotische transabdominelle retromuskuläre umbilikale Patchplastik [r-TARUP]) präsentiert. Es werden die Ergebnisse einer Kohortenstudie an 118 konsekutiven Patienten vorgestellt und im Hinblick auf den Mehrwert der robotischen Technik in der Extraperitonealisierung der Netze und in der Weiterbildung diskutiert. T2 - Robotische Hernienchirurgie II: Robotische primär ventrale und inzisionale Hernienversorgung (rv-TAPP und r-Rives/r-TARUP). Videobeitrag und Ergebnisse einer Kohortenstudie an 118 Patienten KW - umbilical hernia KW - incisional hernia KW - primary ventral hernia KW - minimally invasive KW - retrorectus mesh KW - linea alba KW - Umbilikalhernie KW - Inzisionalhernie KW - primär ventrale Hernie KW - Minimalinvasiv KW - Retrorektus Netz KW - Linea alba Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-323866 VL - 92 IS - Suppl 1 ER - TY - JOUR A1 - Ramser, Michaela A1 - Baur, Johannes A1 - Keller, Nicola A1 - Kukleta, Jan F. A1 - Dörfer, Jörg A1 - Wiegering, Armin A1 - Eisner, Lukas A1 - Dietz, Ulrich A. T1 - Robotic hernia surgery I. English version BT - Robotic inguinal hernia repair (r‑TAPP). Video report and results of a series of 302 hernia operations JF - Der Chirurg N2 - The treatment of inguinal hernias with open and minimally invasive procedures has reached a high standard in terms of outcome over the past 30 years. However, there is still need for further improvement, mainly in terms of reduction of postoperative seroma, chronic pain, and recurrence. This video article presents the endoscopic anatomy of the groin with regard to robotic transabdominal preperitoneal patch plasty (r‑TAPP) and illustrates the surgical steps of r‑TAPP with respective video sequences. The results of a cohort study of 302 consecutive hernias operated by r‑TAPP are presented and discussed in light of the added value of the robotic technique, including advantages for surgical training. r‑TAPP is the natural evolution of conventional TAPP and has the potential to become a new standard as equipment availability increases and material costs decrease. Future studies will also have to refine the multifaceted added value of r‑TAPP with new parameters. N2 - Die Versorgung von Leistenhernien mit offenen und minimal-invasiven Verfahren hat in den vergangenen 30 Jahren einen vom Ergebnis her gesehen hohen Standard erreicht. Allerdings besteht noch Bedarf an einer weiteren Reduktion der postoperativen Serome, chronischen Schmerzen und des Rezidivs. In diesem Videobeitrag wird die endoskopische Anatomie der Leiste im Hinblick auf die robotische transabdominelle präperitoneale Patchplastik (r‑TAPP) dargestellt und die Operationsschritte der r‑TAPP als Video illustriert. Es werden die Ergebnisse einer Kohortenstudie an 302 konsekutiven Hernien, die mittels r‑TAPP operiert wurden, vorgestellt und hinsichtlich des Mehrwerts der robotischen Technik – auch in der Weiterbildung – diskutiert. Die r‑TAPP ist die natürliche Weiterentwicklung der konventionellen TAPP und hat das Potenzial, bei zunehmender Geräteverfügbarkeit und Reduktion der Materialkosten zu einem neuen Standard zu werden. Künftige Studien werden den vielseitigen Mehrwert der r‑TAPP auch mit neuen Parametern verfeinern müssen. T2 - Robotische Hernienchirurgie I : Robotische Leistenhernienversorgung (r-TAPP). Videobeitrag und Ergebnisse einer Kohortenstudie an 302 operierten Hernien KW - groin hernia KW - endoscopic groin hernia repair KW - learning curve KW - transverse fascia KW - seroma KW - Leistenhernie KW - Minimalinvasive Leistenhernienversorgung KW - Lernkurve KW - Fascia transversalis KW - Serom Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-323934 VL - 92 IS - Suppl 1 ER - TY - JOUR A1 - Dietz, Ulrich A. A1 - Kudsi, O. Yusef A1 - Garcia-Ureña, Miguel A1 - Baur, Johannes A1 - Ramser, Michaela A1 - Maksimovic, Sladjana A1 - Keller, Nicola A1 - Dörfer, Jörg A1 - Eisner, Lukas A1 - Wiegering, Armin T1 - Robotic hernia repair III. English version BT - Robotic incisional hernia repair with transversus abdominis release (r‑TAR). Video report and results of a cohort study JF - Der Chirurg N2 - The principle of targeted separation or weakening of individual components of the abdominal wall to relieve tension in the median line during major abdominal reconstruction has been known for over 30 years as anterior component separation (aCS) and is an established procedure. In search of alternatives with lower complication rates, posterior component separation (pCS) was developed; transversus abdominis release (TAR) is a nerve-sparing modification of pCS. With the ergonomic resources of robotics (e.g., angled instruments), TAR can be performed in a minimally invasive manner (r-TAR): hernia gaps of up to 14 cm can be closed and a large extraperitoneal mesh implanted. In this video article, the treatment of large incisional hernias using the r‑TAR technique is presented. Exemplary results of a cohort study in 13 consecutive patients are presented. The procedure is challenging, but our own results—as well as reports from the literature—are encouraging. The r‑TAR is becoming the pinnacle procedure for abdominal wall reconstruction. N2 - Das Prinzip der gezielten Trennung bzw. Schwächung einzelner Komponenten der Bauchdecke zur Spannungsentlastung der Medianlinie bei großen abdominellen Rekonstruktionen ist seit über 30 Jahren als anteriore Komponentenseparation (aKS) bekannt und ein etabliertes Verfahren. Auf der Suche nach Alternativen mit geringerer Komplikationsrate wurde die posteriore Komponentenseparation (pKS) entwickelt; der „transversus abdominis release“ (TAR) ist eine nervenschonende Modifikation der pKS. Mit den ergonomischen Ressourcen der Robotik (z. B. abgewinkelte Instrumente) kann der TAR minimal-invasiv durchgeführt werden (r-TAR): Bruchlücken von bis zu 14 cm lassen sich verschließen und ein großes extraperitoneales Netz implantieren. In diesem Videobeitrag wird die Versorgung großer Inzisionalhernien in der r‑TAR-Technik präsentiert. Exemplarisch werden die Ergebnisse einer Kohortenstudie an 13 konsekutiven Patienten vorgestellt. Der Eingriff ist anspruchsvoll, die eigenen Ergebnisse sind – wie auch die Berichte aus der Literatur – ermutigend. Der r‑TAR entwickelt sich zur Königsdisziplin der Bauchdeckenrekonstruktion. T2 - Robotische Hernienchirurgie III : Robotische Inzisionalhernienversorgung mit transversus abdominis release (r-TAR). Videobeitrag und Ergebnisse einer Kohortenstudie KW - robotic surgical procedures KW - incisional hernia KW - ventral hernia KW - retromuscular mesh KW - posterior component separation KW - Robotik KW - Inzisionale Hernie KW - Ventrale Hernie KW - Retromuskuläres Netz KW - Posteriore Komponentenseparation Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-323896 VL - 92 IS - Suppl 1 ER - TY - GEN A1 - Dietz, Ulrich A. A1 - Kudsi, O. Yusef A1 - Garcia-Ureña, Miguel A1 - Baur, Johannes A1 - Ramser, Michaela A1 - Maksimovic, Sladjana A1 - Keller, Nicola A1 - Dörfer, Jörg A1 - Eisner, Lukas A1 - Wiegering, Armin T1 - Erratum to: Robotic hernia repair III. English version BT - Robotic incisional hernia repair with transversus abdominis release (r-TAR). Video report and results of a cohort study T2 - Der Chirurg N2 - No abstract available. KW - Erratum Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-329360 VL - 92 IS - Suppl 1 SP - 40 ER -