TY - JOUR A1 - Stuckensen, Kai A1 - Lamo-Espinosa, José M. A1 - Muiños-López, Emma A1 - Ripalda-Cemboráin, Purificación A1 - López-Martínez, Tania A1 - Iglesias, Elena A1 - Abizanda, Gloria A1 - Andreu, Ion A1 - Flandes-Iparraguirre, María A1 - Pons-Villanueva, Juan A1 - Elizalde, Reyes A1 - Nickel, Joachim A1 - Ewald, Andrea A1 - Gbureck, Uwe A1 - Prósper, Felipe A1 - Groll, Jürgen A1 - Granero-Moltó, Froilán T1 - Anisotropic cryostructured collagen scaffolds for efficient delivery of RhBMP−2 and enhanced bone regeneration JF - Materials N2 - In the treatment of bone non-unions, an alternative to bone autografts is the use of bone morphogenetic proteins (BMPs), e.g., BMP–2, BMP–7, with powerful osteoinductive and osteogenic properties. In clinical settings, these osteogenic factors are applied using absorbable collagen sponges for local controlled delivery. Major side effects of this strategy are derived from the supraphysiological doses of BMPs needed, which may induce ectopic bone formation, chronic inflammation, and excessive bone resorption. In order to increase the efficiency of the delivered BMPs, we designed cryostructured collagen scaffolds functionalized with hydroxyapatite, mimicking the structure of cortical bone (aligned porosity, anisotropic) or trabecular bone (random distributed porosity, isotropic). We hypothesize that an anisotropic structure would enhance the osteoconductive properties of the scaffolds by increasing the regenerative performance of the provided rhBMP–2. In vitro, both scaffolds presented similar mechanical properties, rhBMP–2 retention and delivery capacity, as well as scaffold degradation time. In vivo, anisotropic scaffolds demonstrated better bone regeneration capabilities in a rat femoral critical-size defect model by increasing the defect bridging. In conclusion, anisotropic cryostructured collagen scaffolds improve bone regeneration by increasing the efficiency of rhBMP–2 mediated bone healing. KW - rhBMP–2 KW - collagen sponge KW - cryostructured scaffolds KW - bone critical size defect Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-195966 SN - 1996-1944 VL - 12 IS - 19 ER - TY - JOUR A1 - Lüdemann, Martin A1 - Jakuscheit, Axel A1 - Ewald, Andrea A1 - Frühmann, Leena A1 - Hölscher-Doht, Stefanie A1 - Rudert, Maximilian A1 - von Hertzberg-Boelch, Sebastian Philipp T1 - Influence of Tranexamic Acid on Elution Characteristics and Compressive Strength of Antibiotic-Loaded PMMA-Bone Cement with Gentamicin JF - Materials N2 - Purpose: The topical application of tranexamic acid (TXA) into the joint space during total joint arthroplasty (TJA) with no increase of complications, has been widely reported. We investigated the influence of TXA on antibiotic release, activity of the released antibiotic against a clinical isolate of S. aureus, and compressive strength of a widely used commercially prepared gentamicin-loaded cement brand (PALACOS R + G). Method: 12 bone cement cylinders (diameter and height = 6 and 12 mm, respectively) were molded. After curing in air for at least 1 h, six of the cylinders were completely immersed in 5 mL of fetal calf serum (FCS) and the other six were completely immersed in a solution consisting of 4.9 mL of FCS and 0.1 mL (10 mg) of TXA. Gentamicin elution tests were performed over 7 d. Four hundred µL of the gentamicin eluate were taken every 24 h for the first 7 d without renewing the immersion fluid. The gentamicin concentration was determined in a clinical analyzer using a homogeny enzyme immuno-assay. The antimicrobial activity of the eluate, obtained after day 7, was tested. An agar diffusion test regime was used with Staphylococcus aureus. Bacteria were grown in a LB medium and plated on LB agar plates to get a bacterial lawn. Fifty µL of each eluate were pipetted on 12-mm diameter filter discs, which were placed in the middle of the agar gel. After 24 h of cultivation at 37 °C, the zone of inhibition (ZOI) for each specimen was measured. The compressive strength of the cements was determined per ISO 5833. Results: At each time point in the gentamicin release test, the difference in gentamicin concentration, obtained from specimens immersed in the FCS solution only and those immersed in the FCS + TXA solution was not significant (p = 0.055–0.522). The same trend was seen in each of the following parameters, after 7 d of immersion: (1) Cumulative gentamicin concentration (p < 0.297); (2) gentamicin activity against S. aureus (strongly visible); (3) ZOI size (mostly > 20 mm) (p = 0.631); and (4) compressive strength (p = 0.262). Conclusions: For the PALACOS R + G specimens, the addition of TXA to FCS does not produce significant decreases in gentamicin concentration, in the activity of the gentamicin eluate against a clinical isolate of S. aureus, the zone of inhibition of S. aureus, and in the compressive strength of the cement, after 7 d of immersion in the test solution. KW - gentamicin-loaded poly (methyl methacrylate) bone cement KW - total joint arthroplasty KW - total knee arthroplasty KW - tranexamic acid Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-246236 SN - 1996-1944 VL - 14 IS - 19 ER - TY - JOUR A1 - Fuchs, Andreas A1 - Kreczy, Dorothea A1 - Brückner, Theresa A1 - Gbureck, Uwe A1 - Stahlhut, Philipp A1 - Bengel, Melanie A1 - Hoess, Andreas A1 - Nies, Berthold A1 - Bator, Julia A1 - Klammert, Uwe A1 - Linz, Christian A1 - Ewald, Andrea T1 - Bone regeneration capacity of newly developed spherical magnesium phosphate cement granules JF - Clinical Oral Investigations N2 - Objectives Magnesium phosphate-based cements begin to catch more attention as bone substitute materials and especially as alternatives for the more commonly used calcium phosphates. In bone substitutes for augmentation purposes, atraumatic materials with good biocompatibility and resorbability are favorable. In the current study, we describe the in vivo testing of novel bone augmentation materials in form of spherical granules based on a calcium-doped magnesium phosphate (CaMgP) cement. Materials and Methods Granules with diameters between 500 and 710 μm were fabricated via the emulsification of CaMgP cement pastes in a lipophilic liquid. As basic material, two different CaMgP formulations were used. The obtained granules were implanted into drill hole defects at the distal femoral condyle of 27 New Zealand white rabbits for 6 and 12 weeks. After explantation, the femora were examined via X-ray diffraction analysis, histological staining, radiological examination, and EDX measurement. Results Both granule types display excellent biocompatibility without any signs of inflammation and allow for proper bone healing without the interposition of connective tissue. CaMgP granules show a fast and continuous degradation and enable fully adequate bone regeneration. Conclusions Due to their biocompatibility, their degradation behavior, and their completely spherical morphology, these CaMgP granules present a promising bone substitute material for bone augmentation procedures, especially in sensitive areas. Clinical Relevance The mostly insufficient local bone supply after tooth extractions complicates prosthetic dental restoration or makes it even impossible. Therefore, bone augmentation procedures are oftentimes inevitable. Spherical CaMgP granules may represent a valuable bone replacement material in many situations. KW - implantation KW - calcium-magnesium phosphate cement KW - cement pastes KW - prefabricated granules KW - bone replacement material Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-268872 SN - 1436-3771 VL - 26 IS - 3 ER - TY - JOUR A1 - Abd El-Aziz, Asmaa M. A1 - El-Maghraby, Azza A1 - Ewald, Andrea A1 - Kandil, Sherif H. T1 - In-vitro cytotoxicity study: cell viability and cell morphology of carbon nanofibrous scaffold/hydroxyapatite nanocomposites JF - Molecules N2 - Electrospun carbon nanofibers (CNFs), which were modified with hydroxyapatite, were fabricated to be used as a substrate for bone cell proliferation. The CNFs were derived from electrospun polyacrylonitrile (PAN) nanofibers after two steps of heat treatment: stabilization and carbonization. Carbon nanofibrous (CNF)/hydroxyapatite (HA) nanocomposites were prepared by two different methods; one of them being modification during electrospinning (CNF-8HA) and the second method being hydrothermal modification after carbonization (CNF-8HA; hydrothermally) to be used as a platform for bone tissue engineering. The biological investigations were performed using in-vitro cell counting, WST cell viability and cell morphology after three and seven days. L929 mouse fibroblasts were found to be more viable on the hydrothermally-modified CNF scaffolds than on the unmodified CNF scaffolds. The biological characterizations of the synthesized CNF/HA nanofibrous composites indicated higher capability of bone regeneration. KW - HA modifiedCNF membranes KW - cytotoxicity KW - WST test KW - cell counting KW - cell viability KW - cell morphology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-234037 SN - 1420-3049 VL - 26 IS - 6 ER - TY - JOUR A1 - Eidmann, Annette A1 - Ewald, Andrea A1 - Boelch, Sebastian P. A1 - Rudert, Maximilian A1 - Holzapfel, Boris M. A1 - Stratos, Ioannis T1 - In vitro evaluation of antibacterial efficacy of vancomycin-loaded suture tapes and cerclage wires JF - Journal of Materials Science: Materials in Medicine N2 - Usage of implants containing antibiotic agents has been a common strategy to prevent implant related infections in orthopedic surgery. Unfortunately, most implants with microbial repellent properties are characterized by accessibility limitations during daily clinical practice. Aim of this in vitro study was to investigate whether suture tapes and cerclage wires, which were treated with vancomycin, show a sustainable antibacterial activity. For this purpose, we used 24 stainless steel wire cerclages and 24 ultra-high molecular weight polyethylene and polyester suture tape test bodies. The test bodies were incubated for 30 min. in 100 mg/ml vancomycin solution or equivalent volumes of 0.9% NaCl. After measuring the initial solution uptake of the test bodies, antibacterial efficacy via agar diffusion test with Staphylococcus aureus and vancomycin elution tests were performed 1, 2, 3, and 6 days after incubation. Vancomycin-loaded tapes as well as vancomycin-loaded cerclage wires demonstrated increased bacterial growth inhibition when compared to NaCl-treated controls. Vancomycin-loaded tapes showed an additional twofold and eightfold increase of bacterial growth inhibition compared to vancomycin-loaded wires at day 1 and 2, respectively. Elution tests at day 1 revealed high levels of vancomycin concentration in vancomycin loaded tapes and wires. Additionally, the concentration in vancomycin loaded tapes was 14-fold higher when compared to vancomycin loaded wires. Incubating suture tapes and cerclage wires in vancomycin solution showed a good short-term antibacterial activity compared to controls. Considering the ease of vancomycin application on suture tapes or wires, our method could represent an attractive therapeutic strategy in biofilm prevention in orthopedic surgery. KW - anti-bacterial agents / administration & dosage KW - anti-bacterial agents / chemistry KW - bone wires KW - drug liberation KW - materials testing KW - anti-bacterial agents / pharmacology KW - biocompatible Materials KW - prostheses and implants KW - Staphylococcus aureus / drug effects KW - sutures KW - Vancomycin / administration & dosage KW - Vancomycin / chemistry KW - Vancomycin / pharmacology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-260089 VL - 32 IS - 4 ER -