TY - JOUR A1 - Born, Dennis-Peter A1 - Holmberg, Hans-Christer A1 - Goernet, Florian A1 - Sperlich, Billy T1 - A novel compression garment with adhesive silicone stripes improves repeated sprint performance – a multi-experimental approach on the underlying mechanisms JF - BMC Sports Science, Medicine and Rehabilitation N2 - Background Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors. Methods In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12). Results In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered. Conclusion Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique. KW - textile KW - tissue saturation index KW - venous system KW - video analysis KW - oxygen uptake KW - blood flow KW - clothing KW - oscillation KW - oxygenation Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-120591 SN - 2052-1847 VL - 6 IS - 21 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Holmberg, Hans-Christer A1 - Goernert, Florian A1 - Sperlich, Billy T1 - A novel compression garment with adhesive silicone stripes improves repeated sprint performance – a multi-experimental approach on the underlying mechanisms JF - BMC Sports Science, Medicine and Rehabilitation N2 - Background Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors. Methods In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12). Results In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered. Conclusion Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique. KW - tissue saturation index KW - blood flow KW - clothing KW - oscillation KW - oxygenation KW - oxygen uptake KW - textile KW - venous system KW - video analysis Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-116995 UR - http://www.biomedcentral.com/2052-1847/6/21 VL - 6 IS - 21 ER - TY - JOUR A1 - Sperlich, Paula F. A1 - Holmberg, Hans-Christer A1 - Reed, Jennifer L. A1 - Zinner, Christoph A1 - Mester, Joachim A1 - Sperlich, Billy T1 - Individual versus standardized running protocols in the determination of VO\(_{2max}\) JF - Journal of Sports Science and Medicine N2 - The purpose of this study was to determine whether an individually designed incremental exercise protocol results in greater rates of oxygen uptake VO\(_{2max}\) than standardized testing. Fourteen well-trained, male runners performed five incremental protocols in randomized order to measure their VO\(_{2max}\): i) an incremental test (INC\(_{S+I}\)) with pre-defined increases in speed (2 min at 8.64 km.h\(^{-1}\), then a rise of 1.44 km.h\(^{-1}\) every 30 s up to 14.4 km.h\(^{-1}\)) and thereafter inclination (0.5.every 30 s); ii) an incremental test (INC\(_{I}\)) at constant speed (14.4 km.h\(^{-1}\)) and increasing inclination (2 degrees every 2 min from the initial 0 degrees); iii) an incremental test (INC\(_{S}\)) at constant inclination (0 degrees) and increasing speed (0.5 km.h\(^{-1}\) every 30 s from the initial 12.0 km.h\(^{-1}\)); iv) a graded exercise protocol (GXP) at a 1 degrees incline with increasing speed (initially 8.64 km.h\(^{-1}\) + 1.44 km.h\(^{-1}\) every 5 min); v) an individual exercise protocol (INDXP) in which the runner chose the inclination and speed. VO\(_{2max}\) was lowest (-4.2%) during the GXP (p = 0.01; d = 0.06 - 0.61) compared to all other tests. The highest rating of perceived exertion, heart rate, ventilation and end-exercise blood lactate concentration were similar between the different protocols (p < 0.05). The time to exhaustion ranged from 7 min 18 sec (INC\(_{S}\)) to 25 min 30 sec (GXP) (p = 0.01). The VO\(_{2max}\) attained by employing an individual treadmill protocol does not differ from the values derived from various standardized incremental protocols. KW - maximum oxygen uptake KW - aerobic power KW - treadmill running KW - ramp test KW - treadmill protocol Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-151890 VL - 14 ER - TY - JOUR A1 - Zinner, Christoph A1 - Hauser, Anna A1 - Born, Dennis-Peter A1 - Wehrlin, Jon P. A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Influence of Hypoxic Interval Training and Hyperoxic Recovery on Muscle Activation and Oxygenation in Connection with Double-Poling Exercise JF - PLoS One N2 - Here, we evaluated the influence of breathing oxygen at different partial pressures during recovery from exercise on performance at sea-level and a simulated altitude of 1800 m, as reflected in activation of different upper body muscles, and oxygenation of the m. triceps brachii. Ten well-trained, male endurance athletes (25.3±4.1 yrs; 179.2±4.5 cm; 74.2±3.4 kg) performed four test trials, each involving three 3-min sessions on a double-poling ergometer with 3-min intervals of recovery. One trial was conducted entirely under normoxic (No) and another under hypoxic conditions \((Ho; F_iO_2 = 0.165)\). In the third and fourth trials, the exercise was performed in normoxia and hypoxia, respectively, with hyperoxic recovery \((HOX; F_iO_2 = 1.00)\) in both cases. Arterial hemoglobin saturation was higher under the two HOX conditions than without HOX (p<0.05). Integrated muscle electrical activity was not influenced by the oxygen content (best d = 0.51). Furthermore, the only difference in tissue saturation index measured via near-infrared spectroscopy observed was between the recovery periods during the NoNo and HoHOX interventions (P<0.05, d = 0.93). In the case of HoHo the athletes’ \(P_{mean}\) declined from the first to the third interval (P < 0.05), whereas Pmean was unaltered under the HoHOX, NoHOX and NoNo conditions. We conclude that the less pronounced decline in \(P_{mean}\) during 3 x 3-min double-poling sprints in normoxia and hypoxia with hyperoxic recovery is not related to changes in muscle activity or oxygenation. Moreover, we conclude that hyperoxia \((F_iO_2 = 1.00)\) used in conjunction with hypoxic or normoxic work intervals may serve as an effective aid when inhaled during the subsequent recovery intervals. KW - triceps KW - bood KW - medical hypoxia KW - blood KW - arms KW - hyperoxia KW - breathing KW - near-infrared spectroscopy Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-126299 VL - 10 IS - 10 ER - TY - JOUR A1 - Düking, Peter A1 - Hotho, Andreas A1 - Holmberg, Hans-Christer A1 - Fuss, Franz Konstantin A1 - Sperlich, Billy T1 - Comparison of Non-Invasive Individual Monitoring of the Training and Health of Athletes with Commercially Available Wearable Technologies JF - Frontiers in Physiology N2 - Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables) provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete's training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health. KW - sports technology KW - wearable technologies KW - performance parameters KW - health monitoring KW - performance monitoring Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-165516 VL - 7 IS - 71 ER - TY - JOUR A1 - Sperlich, Billy A1 - Wallmann-Sperlich, Birgit A1 - Zinner, Christoph A1 - Von Stauffenberg, Valerie A1 - Losert, Helena A1 - Holmberg, Hans-Christer T1 - Functional High-intensity Circuit Training Improves Body Composition,Peak Oxygen Uptake, Strength, and Alters Certain Dimensions of Quality of Life in Overweight Women JF - Frontiers in Physiology N2 - The effects of circuit-like functional high-intensity training (Circuit\(_{HIIT}\)) alone or in combination with high-volume low-intensity exercise (Circuit\(_{combined}\)) on selected cardio-respiratory and metabolic parameters, body composition, functional strength and the quality of life of overweight women were compared. In this single-center, two-armed randomized, controlled study, overweight women performed 9-weeks (3 sessions·wk\(^{−1}\)) of either Circuit\(_{HIIT}\) (n = 11), or Circuit\(_{combined}\) (n = 8). Peak oxygen uptake and perception of physical pain were increased to a greater extent (p < 0.05) by Circuit\(_{HIIT}\), whereas Circuit\(_{combined}\) improved perception of general health more (p < 0.05). Both interventions lowered body mass, body-mass-index, waist-to-hip ratio, fat mass, and enhanced fat-free mass; decreased ratings of perceived exertion during submaximal treadmill running; improved the numbers of push-ups, burpees, one-legged squats, and 30-s skipping performed, as well as the height of counter-movement jumps; and improved physical and social functioning, role of physical limitations, vitality, role of emotional limitations, and mental health to a similar extent (all p < 0.05). Either forms of these multi-stimulating, circuit-like, multiple-joint training can be employed to improve body composition, selected variables of functional strength, and certain dimensions of quality of life in overweight women. However, Circuit\(_{HIIT}\) improves peak oxygen uptake to a greater extent, but with more perception of pain, whereas Circuit\(_{Combined}\) results in better perception of general health. KW - power training KW - aerobic fitness KW - body composition KW - female KW - functional training KW - interval training Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-171015 VL - 8 IS - 172 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Instant Biofeedback Provided by Wearable Sensor Technology Can Help to Optimize Exercise and Prevent Injury and Overuse JF - Frontiers in Physiology KW - sports KW - training optimization KW - performance monitoring KW - health monitoring KW - technology KW - coaching Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158044 VL - 8 IS - 167 ER - TY - JOUR A1 - Sperlich, Billy A1 - Holmberg, Hans-Christer T1 - The responses of elite athletes to exercise: an all-day, 24-h integrative view is required! JF - Frontiers in Physiology N2 - No abstract available. KW - physiological KW - athletes KW - wearable sensors KW - training intensity distribution KW - monitoring KW - biofeedback Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158655 VL - 8 IS - 564 ER - TY - JOUR A1 - Sperlich, Billy A1 - Düking, Peter A1 - Holmberg, Hans-Christer T1 - A SWOT analysis of the use and potential misuse of implantable monitoring devices by athletes JF - Frontiers in Physiology N2 - Kein Abstract vorhanden. KW - ingestible sensor KW - sensor assessment KW - implant KW - implantable neurostimulators KW - athletes Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158742 VL - 8 IS - 629 ER - TY - JOUR A1 - Düking, Peter A1 - Achtzehn, Silvia A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Integrated framework of load monitoring by a combination of smartphone applications, wearables and point-of-care testing provides feedback that allows individual responsive adjustments to activities of daily living JF - Sensors N2 - Athletes schedule their training and recovery in periods, often utilizing a pre-defined strategy. To avoid underperformance and/or compromised health, the external load during training should take into account the individual’s physiological and perceptual responses. No single variable provides an adequate basis for planning, but continuous monitoring of a combination of several indicators of internal and external load during training, recovery and off-training as well may allow individual responsive adjustments of a training program in an effective manner. From a practical perspective, including that of coaches, monitoring of potential changes in health and performance should ideally be valid, reliable and sensitive, as well as time-efficient, easily applicable, non-fatiguing and as non-invasive as possible. Accordingly, smartphone applications, wearable sensors and point-of-care testing appear to offer a suitable monitoring framework allowing responsive adjustments to exercise prescription. Here, we outline 24-h monitoring of selected parameters by these technologies that (i) allows responsive adjustments of exercise programs, (ii) enhances performance and/or (iii) reduces the risk for overuse, injury and/or illness. KW - biofeedback KW - eHealth KW - individualized training KW - injury prevention KW - IoT KW - periodization KW - load management Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176506 VL - 18 IS - 5 ER - TY - JOUR A1 - Sperlich, Billy A1 - De Clerck, Ine A1 - Zinner, Christoph A1 - Holmberg,, Hans-Christer A1 - Wallmann-Sperlich, Birgit T1 - Prolonged sitting interrupted by 6-min of high-intensity exercise: circulatory, metabolic, hormonal, thermal, cognitive, and perceptual responses JF - Frontiers in Physiology N2 - The aim was to examine certain aspects of circulatory, metabolic, hormonal, thermoregulatory, cognitive, and perceptual responses while sitting following a brief session of high-intensity interval exercise. Twelve students (five men; age, 22 ± 2 years) performed two trials involving either simply sitting for 180 min (SIT) or sitting for this same period with a 6-min session of high-intensity exercise after 60 min (SIT+HIIT). At T\(_0\) (after 30 min of resting), T\(_1\) (after a 20-min breakfast), T\(_2\) (after sitting for 1 h), T\(_3\) (immediately after the HIIT), T\(_4\), T\(_5\), T\(_6\), and T\(_7\) (30, 60, 90, and 120 min after the HIIT), circulatory, metabolic, hormonal, thermoregulatory, cognitive, and perceptual responses were assessed. The blood lactate concentration (at T\(_3\)–T\(_5\)), heart rate (at T\(_3\)–T\(_6\)), oxygen uptake (at T\(_3\)–T\(_7\)), respiratory exchange ratio, and sensations of heat (T\(_3\)–T\(_5\)), sweating (T\(_3\), T\(_4\)) and odor (T\(_3\)), as well as perception of vigor (T\(_3\)–T\(_6\)), were higher and the respiratory exchange ratio (T\(_4\)–T\(_7\)) and mean body and skin temperatures (T\(_3\)) lower in the SIT+HIIT than the SIT trial. Levels of blood glucose and salivary cortisol, cerebral oxygenation, and feelings of anxiety/depression, fatigue or hostility, as well as the variables of cognitive function assessed by the Stroop test did not differ between SIT and SIT+HIIT. In conclusion, interruption of prolonged sitting with a 6-min session of HIIT induced more pronounced circulatory and metabolic responses and improved certain aspects of perception, without affecting selected hormonal, thermoregulatory or cognitive functions. KW - inactivity KW - high-intensity interval training KW - sedentary lifestyle KW - students KW - workplace KW - intervention KW - physical activity KW - health promotion Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-177307 VL - 9 IS - 1279 ER - TY - JOUR A1 - Sperlich, Billy A1 - Hahn, Lea-Sofie A1 - Edel, Antonia A1 - Behr, Tino A1 - Helmprobst, Julian A1 - Leppich, Robert A1 - Wallmann-Sperlich, Birgit A1 - Holmberg, Hans-Christer T1 - A 4-week intervention involving mobile-based daily 6-minute micro-sessions of functional high-intensity circuit training improves strength and quality of life, but not cardio-respiratory fitness of young untrained adults JF - Frontiers in Physiology N2 - The present study was designed to assess the psycho-physiological responses of physically untrained individuals to mobile-based multi-stimulating, circuit-like, multiple-joint conditioning (Circuit\(_{HIIT}\)) performed either once (1xCircuitHIIT) or twice (2xCircuit\(_{HIIT}\)) daily for 4 weeks. In this single-center, two-arm randomized, controlled study, 24 men and women (age: 25 ± 5 years) first received no training instructions for 4 weeks and then performed 4 weeks of either 1xCircuitHIIT or 2xCircuit\(_{HIIT}\) (5 men and 7 women in each group) daily. The 1xCircuitHIIT and 2xCircuit\(_{HIIT}\) participants carried out 90.7 and 85.7% of all planned training sessions, respectively, with average heart rates during the 6-min sessions of 74.3 and 70.8% of maximal heart rate. Body, fat and fat-free mass, and metabolic rate at rest did not differ between the groups or between time-points of measurement. Heart rate while running at 6 km⋅h\(^{-1}\) declined after the intervention in both groups. Submaximal and peak oxygen uptake, the respiratory exchange ratio and heart rate recovery were not altered by either intervention. The maximal numbers of push-ups, leg-levers, burpees, 45°-one-legged squats and 30-s skipping, as well as perception of general health improved in both groups. Our 1xCircuit\(_{HIIT}\) or 2xCircuit\(_{HIIT}\) interventions improved certain parameters of functional strength and certain dimensions of quality of life in young untrained individuals. However, they were not sufficient to enhance cardio-respiratory fitness, in particular peak oxygen uptake. KW - aerobic fitness KW - body composition KW - functional training KW - mHealth KW - power training KW - V800 KW - wearable KW - web-based apps Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176565 VL - 9 IS - 423 ER - TY - JOUR A1 - Düking, Peter A1 - Fuss, Franz Konstantin A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Recommendations for assessment of the reliability, sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity JF - JMIR Mhealth and Uhealth N2 - Although it is becoming increasingly popular to monitor parameters related to training, recovery, and health with wearable sensor technology (wearables), scientific evaluation of the reliability, sensitivity, and validity of such data is limited and, where available, has involved a wide variety of approaches. To improve the trustworthiness of data collected by wearables and facilitate comparisons, we have outlined recommendations for standardized evaluation. We discuss the wearable devices themselves, as well as experimental and statistical considerations. Adherence to these recommendations should be beneficial not only for the individual, but also for regulatory organizations and insurance companies. KW - internet of things KW - activity tracker KW - data mining KW - load management KW - physical activity KW - smartwatch Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176202 VL - 6 IS - 4 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - The potential usefulness of virtual reality systems for athletes: a short SWOT analysis JF - Frontiers in Physiology N2 - No abstract available. KW - SWOT KW - virtual reality KW - athletes Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176178 VL - 9 IS - 128 ER - TY - JOUR A1 - Kunz, Philipp A1 - Zinner, Christoph A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Intra- and post-match time-course of indicators related to perceived and performance fatigability and recovery in elite youth soccer players JF - Frontiers in Physiology N2 - PurposeOur aims were to examine (i) the internal load during simulated soccer match-play by elite youth players; and (ii) the time-course of subsequent recovery from perceived and performance fatigability. MethodsEleven male youth players (16 ± 1 years, 178 ± 7 cm, 67 ± 7 kg) participated in a 2 × 40-min simulated soccer match, completing 30 rounds (160 s each) with every round including multidirectional and linear sprinting (LS20m), jumping (CMJ) and running at different intensities. During each round, LS20m, CMJ, agility, heart rate (HR), oxygen uptake (VO2), energy expenditure (EE), substrate utilization and perceived exertion RPE were assessed. In addition, the blood level of lactate (Lac) was obtained after each of the five rounds. Creatine kinase (CK) concentration, maximal voluntary isometric knee extension and flexion, CMJ, number of skippings in 30 s, and subjective ratings on the Acute Recovery and Stress Scale (ARSS) were examined before and immediately, 24 and 48 h after the simulation. Results: During the game %HR\(_{peak}\) (p < 0.05, d = 1.08), %VO2\(_{peak}\) (p < 0.05; d = 0.68), Lac (p < 0.05, d = 2.59), RPE\(_{total}\) (p < 0.05, d = 4.59), and RPE\(_{legs}\) (p < 0.05, d = 4.45) all increased with time during both halves (all p < 0.05). Agility improved (p < 0.05, d = 0.70) over the time-course of the game, with no changes in LS20m (p ≥ 0.05, d = 0.34) or CMJ (p ≥ 0.05, d = 0.27). EE was similar during both halves (528 ± 58 vs. 514 ± 61 kcal; p = 0.60; d = 0.23), with 62% (second half: 65%) carbohydrate, 9% (9%) protein and 26% (27%) fat utilization. With respect to recovery, maximal voluntary knee extension (p ≥ 0.05, d = 0.50) and flexion force (p ≥ 0.05, d = 0.19), CMJ (p ≥ 0.05, d = 0.13), number of ground contacts (p ≥ 0.05, d = 0.57) and average contact time (p ≥ 0.05, d = 0.39) during 30-s of skipping remained unaltered 24 and 48 h after the game. Most ARSS dimensions of load (p < 0.05, d = 3.79) and recovery (p < 0.05, d = 3.22) returned to baseline levels after 24 h of recovery. Relative to baseline values, CK was elevated immediately and 24 h after (p < 0.05, d = 2.03) and normalized 48 h later. ConclusionIn youth soccer players the simulated match evoked considerable circulatory, metabolic and perceptual load, with an EE of 1042 ± 118 kcal. Among the indicators of perceived and performance fatigability examined, the level of CK and certain subjective ratings differed considerably immediately following or 24–48 h after a 2 × 40-min simulated soccer match in comparison to baseline. Accordingly, monitoring these variables may assist coaches in assessing a U17 player’s perceived and performance fatigability in connection with scheduling training following a soccer match. KW - soccer (football) KW - youth KW - match load KW - fatigue KW - intermittent exercise KW - performance Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-195657 SN - 1664-042X VL - 10 IS - 1383 ER - TY - JOUR A1 - Kunz, Philipp A1 - Azad Engel, Florian A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - A meta-comparison of the effects of high-intensity interval training to those of small-sided games and other training protocols on parameters related to the physiology and performance of youth soccer players JF - Sports Medicine - Open N2 - Background High-intensity interval training (HIIT) is frequently employed to improve the endurance of various types of athletes. To determine whether youth soccer players may benefit from the intermittent load and time efficiency of HIIT, we performed a meta-analysis of the relevant scientific literature. Objectives Our primary objective was to compare changes in various physiological parameters related to the performance of youth soccer players in response to running-based HIIT to the effects of other common training protocols (i.e., small-sided games, technical training and soccer-specific training, or high-volume endurance training). A secondary objective was to compare specifically running-based HIIT to a soccer-specific form of HIIT known as small-sided games (SSG) in this same respect, since this latter type of training is being discussed extensively by coaches. Method A systematic search of the PubMed, SPORTDiscus, and Web of Science databases was performed in August of 2017 and updated during the review process in December of 2018. The criteria for inclusion of articles for analysis were as follows: (1) comparison of HIIT to SSG or some other training protocol employing a pre-post design, (2) involvement of healthy young athletes (≤ 18 years old), and (3) assessment of variables related to endurance or soccer performance. Hedges’ g effect size (dppc2) and associated 95% confidence intervals for the comparison of the responses to HIIT and other interventions were calculated. Results Nine studies, involving 232 young soccer players (mean age 16.2 ± 1.6 years), were examined. Endurance training in the form of HIIT or SSG produced similar positive effects on most parameters assessed, including peak oxygen uptake and maximal running performance during incremental running (expressed as Vmax or maximal aerobic speed (MAS)), shuttle runs (expressed as the distance covered or time to exhaustion), and time-trials, as well as submaximal variables such as running economy and running velocity at the lactate threshold. HIIT induced a moderate improvement in soccer-related tests involving technical exercises with the soccer ball and other game-specific parameters (i.e., total distance covered, number of sprints, and number of involvements with the ball). Neuromuscular parameters were largely unaffected by HIIT or SSG. Conclusion The present meta-analysis indicates that HIIT and SSG have equally beneficial impacts on variables related to the endurance and soccer-specific performance of youth soccer players, but little influence on neuromuscular performance. KW - adolescents KW - children KW - conditioning KW - endurance KW - repeated sprint Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-200332 VL - 5 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans‑Christer A1 - Kunz, Philipp A1 - Leppich, Robert A1 - Sperlich, Billy T1 - Intra-individual physiological response of recreational runners to different training mesocycles: a randomized cross-over study JF - European Journal of Applied Physiology N2 - Purpose Pronounced differences in individual physiological adaptation may occur following various training mesocycles in runners. Here we aimed to assess the individual changes in performance and physiological adaptation of recreational runners performing mesocycles with different intensity, duration and frequency. Methods Employing a randomized cross-over design, the intra-individual physiological responses [i.e., peak (\(\dot{VO}_{2peak}\)) and submaximal (\(\dot{VO}_{2submax}\)) oxygen uptake, velocity at lactate thresholds (V\(_2\), V\(_4\))] and performance (time-to-exhaustion (TTE)) of 13 recreational runners who performed three 3-week sessions of high-intensity interval training (HIIT), high-volume low-intensity training (HVLIT) or more but shorter sessions of HVLIT (high-frequency training; HFT) were assessed. Results \(\dot{VO}_{2submax}\), V\(_2\), V\(_4\) and TTE were not altered by HIIT, HVLIT or HFT (p > 0.05). \(\dot{VO}_{2peak}\) improved to the same extent following HVLIT (p = 0.045) and HFT (p = 0.02). The number of moderately negative responders was higher following HIIT (15.4%); and HFT (15.4%) than HVLIT (7.6%). The number of very positive responders was higher following HVLIT (38.5%) than HFT (23%) or HIIT (7.7%). 46% of the runners responded positively to two mesocycles, while 23% did not respond to any. Conclusion On a group level, none of the interventions altered \(\dot{VO}_{2submax}\), V\(_2\), V\(_4\) or TTE, while HVLIT and HFT improved \(\dot{VO}_{2peak}\). The mean adaptation index indicated similar numbers of positive, negative and non-responders to HIIT, HVLIT and HFT, but more very positive responders to HVLIT than HFT or HIIT. 46% responded positively to two mesocycles, while 23% did not respond to any. These findings indicate that the magnitude of responses to HIIT, HVLIT and HFT is highly individual and no pattern was apparent. KW - cardiorespiratory fitness KW - endurance KW - personalized training Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235022 SN - 1439-6319 VL - 120 ER - TY - JOUR A1 - Düking, Peter A1 - Giessing, Laura A1 - Frenkel, Marie Ottilie A1 - Koehler, Karsten A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study JF - JMIR mhealth and uhealth N2 - Background: Physical activity reduces the incidences of noncommunicable diseases, obesity, and mortality, but an inactive lifestyle is becoming increasingly common. Innovative approaches to monitor and promote physical activity are warranted. While individual monitoring of physical activity aids in the design of effective interventions to enhance physical activity, a basic prerequisite is that the monitoring devices exhibit high validity. Objective: Our goal was to assess the validity of monitoring heart rate (HR) and energy expenditure (EE) while sitting or performing light-to-vigorous physical activity with 4 popular wrist-worn wearables (Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa). Methods: While wearing the 4 different wearables, 25 individuals performed 5 minutes each of sitting, walking, and running at different velocities (ie, 1.1 m/s, 1.9 m/s, 2.7 m/s, 3.6 m/s, and 4.1 m/s), as well as intermittent sprints. HR and EE were compared to common criterion measures: Polar-H7 chest belt for HR and indirect calorimetry for EE. Results: While monitoring HR at different exercise intensities, the standardized typical errors of the estimates were 0.09-0.62, 0.13-0.88, 0.62-1.24, and 0.47-1.94 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 0.9%-4.3%, 2.2%-6.7%, 2.9%-9.2%, and 4.1%-19.1%, respectively, for the 4 wearables. While monitoring EE at different exercise intensities, the standardized typical errors of the estimates were 0.34-1.84, 0.32-1.33, 0.46-4.86, and 0.41-1.65 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 13.5%-27.1%, 16.3%-28.0%, 15.9%-34.5%, and 8.0%-32.3%, respectively. Conclusions: The Apple Watch Series 4 provides the highest validity (ie, smallest error rates) when measuring HR while sitting or performing light-to-vigorous physical activity, followed by the Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, in that order. The Apple Watch Series 4 and Polar Vantage V are suitable for valid HR measurements at the intensities tested, but HR data provided by the Garmin Fenix 5 and Fitbit Versa should be interpreted with caution due to higher error rates at certain intensities. None of the 4 wrist-worn wearables should be employed to monitor EE at the intensities and durations tested." KW - cardiorespiratory fitness KW - innovation KW - smartwatch KW - technology KW - wearable KW - digital health Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229413 VL - 8 IS - 5 ER - TY - JOUR A1 - Düking, Peter A1 - Zinner, Christoph A1 - Reed, Jennifer L. A1 - Holmberg, Hans‐Christer A1 - Sperlich, Billy T1 - Predefined vs data‐guided training prescription based on autonomic nervous system variation: A systematic review JF - Scandinavian Journal of Medicine & Science in Sports N2 - Monitoring variations in the functioning of the autonomic nervous system may help personalize training of runners and provide more pronounced physiological adaptations and performance improvements. We systematically reviewed the scientific literature comparing physiological adaptations and/or improvements in performance following training based on responses of the autonomic nervous system (ie, changes in heart rate variability) and predefined training. PubMed, SPORTDiscus, and Web of Science were searched systematically in July 2019. Keywords related to endurance, running, autonomic nervous system, and training. Studies were included if they (a) involved interventions consisting predominantly of running training; (b) lasted at least 3 weeks; (c) reported pre‐ and post‐intervention assessment of running performance and/or physiological parameters; (d) included an experimental group performing training adjusted continuously on the basis of alterations in HRV and a control group; and (e) involved healthy runners. Five studies involving six interventions and 166 participants fulfilled our inclusion criteria. Four HRV‐based interventions reduced the amount of moderate‐ and/or high‐intensity training significantly. In five interventions, improvements in performance parameters (3000 m, 5000 m, Loadmax, Tlim) were more pronounced following HRV‐based training. Peak oxygen uptake (VO\(_{2peak}\)) and submaximal running parameters (eg, LT1, LT2) improved following both HRV‐based and predefined training, with no clear difference in the extent of improvement in VO\(_{2peak}\). Submaximal running parameters tended to improve more following HRV‐based training. Research findings to date have been limited and inconsistent. Both HRV‐based and predefined training improve running performance and certain submaximal physiological adaptations, with effects of the former training tending to be greater. KW - cardiorespiratory fitness KW - eHealth KW - endurance KW - innovation KW - technology KW - training KW - wearable Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217893 VL - 30 IS - 12 SP - 2291 EP - 2304 ER - TY - JOUR A1 - McIlroy, Benjamin A1 - Passfield, Louis A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Virtual training of endurance cycling – A summary of strengths, weaknesses, opportunities and threats JF - Frontiers in Sports and Active Living N2 - Virtual online training has emerged as one of the top 20 worldwide fitness trends for 2021 and continues to develop rapidly. Although this allows the cycling community to engage in virtual training and competition, critical evaluation of virtual training platforms is limited. Here, we discuss the strengths, weaknesses, opportunities and threats associated with virtual training technology and cycling in an attempt to enhance awareness of such aspects. Strengths include immersive worlds, innovative drafting mechanics, and versatility. Weaknesses include questionable data accuracy, inadequate strength and reliability of power-speed algorithms. Opportunities exist for expanding strategic partnerships with major cycling races, brands, and sponsors and improving user experience with the addition of video capture and “e-coaching.” Threats are present in the form of cheating during competition, and a lack of uptake and acceptance by a broader community. KW - algorithms KW - cycling KW - e-coach KW - e-health KW - ergometer KW - simulation KW - virtual training KW - SWOT Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-258876 VL - 3 ER -