TY - JOUR A1 - Sinn, Stefan A1 - Eichler, Mirjam A1 - Müller, Lothar A1 - Bünger, Daniel A1 - Groll, Jüergen A1 - Ziemer, Gerhard A1 - Rupp, Frank A1 - Northoff, Hinnak A1 - Geis-Gerstorfer, Jürgen A1 - Gehring, Frank K. A1 - Wendel, Hans P. T1 - NCO-sP(EO-stat-PO) Coatings on Gold Sensors-a QCM Study of Hemocompatibility JF - Sensors N2 - The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide-polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), beta-thromboglobulin (beta-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules. KW - self-assembled monolayers KW - 316L stainless-steel KW - protein adsorption KW - poly(ethylene glycol) KW - platelet-adhesion KW - blood-plasma KW - surfaces KW - biosensor KW - cell self-assembled monolayers KW - cell coagulation KW - surface coating KW - biosensors KW - hemocompatibility KW - QCM Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-141110 VL - 11 IS - 5 ER - TY - JOUR A1 - Paschke, Ralf A1 - Lincke, Thomas A1 - Müller, Stefan P. A1 - Kreissl, Michael C. A1 - Dralle, Henning A1 - Fassnacht, Martin T1 - The Treatment of Well-Differentiated Thyroid Carcinoma JF - Deutsches Ärzteblatt International N2 - Background: Recent decades have seen a rise in the incidence of well-differentiated (mainly papillary) thyroid carcinoma around the world. In Germany, the age-adjusted incidence of well-differentiated thyroid carcinoma in 2010 was 3.5 per 100 000 men and 8.7 per 100 000 women per year. Method: This review is based on randomized, controlled trials and multicenter trials on the treatment of well-differentiated thyroid carcinoma that were retrieved by a selective literature search, as well as on three updated guidelines issued in the past two years. Results: The recommended extent of surgical resection depends on whether the tumor is classified as low-risk or high-risk, so that papillary microcar cinomas, which carry a highly favorable prognosis, will not be overtreated. More than 90% of localized, well-differentiated thyroid carcinomas can be cured with a combination of surgery and radioactive iodine therapy. Radio active iodine therapy is also effective in the treatment of well-differentiated thyroid carcinomas with distant metastases, yielding a 10-year survival rate of 90%, as long as there is good iodine uptake and the tumor goes into remission after treatment; otherwise, the 10-year survival rate is only 10%. In the past two years, better treatment options have become available for radioactive-iodine-resistant thyroid carcinoma. Phase 3 studies of two different tyrosine kinase inhibitors have shown that either one can markedly prolong progression-free survival, but not overall survival. Their more common clinically significant side effects are hand-foot syndrome, hypertension, diarrhea, proteinuria, and weight loss. Conclusion: Slow tumor growth, good resectability, and susceptibility to radioactive iodine therapy lend a favorable prognosis to most cases of well-differentiated thyroid carcinoma. The treatment should be risk-adjusted and interdisciplinary, in accordance with the current treatment guidelines. Even metastatic thyroid carcinoma has a favorable prognosis as long as there is good iodine uptake. The newly available medical treatment options for radioactive-iodine-resistant disease need to be further studied. KW - BRAF(V600E) mutation KW - distant metastases KW - papillary KW - guidelines KW - surgery KW - dissection KW - management KW - association KW - cancer KW - radioiodine therapy Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-151636 VL - 112 SP - 452 EP - 458 ER - TY - JOUR A1 - Herrmann, David P. A1 - Müller-Graff, Franz-Tassilo A1 - Kaulitz, Stefan A1 - Cebulla, Mario A1 - Kurz, Anja A1 - Hagen, Rudolf A1 - Neun, Tilmann A1 - Rak, Kristen T1 - Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position JF - Scientific Reports N2 - This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCT\(_{SECO}\)). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion. KW - facial nerve KW - electromyographic KW - cochlear implantation Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300197 VL - 12 IS - 1 ER -