TY - JOUR A1 - Kraft, Johannes A1 - Weick, Stefan A1 - Breuer, Kathrin A1 - Lutyj, Paul A1 - Bratengeier, Klaus A1 - Exner, Florian A1 - Richter, Anne A1 - Tamihardja, Jörg A1 - Lisowski, Dominik A1 - Polat, Bülent A1 - Flentje, Michael T1 - Treatment plan comparison for irradiation of multiple brain metastases with hippocampal avoidance whole brain radiotherapy and simultaneous integrated boost using the Varian Halcyon and the Elekta Synergy platforms JF - Radiation Oncology N2 - No abstract available. KW - treatment plan KW - multiple brain metastases Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301221 VL - 17 ER - TY - JOUR A1 - Lisowski, Dominik A1 - Lutyj, Paul A1 - Abazari, Arya A1 - Weick, Stefan A1 - Traub, Jan A1 - Polat, Bülent A1 - Flentje, Michael A1 - Kraft, Johannes T1 - Impact of Radiotherapy on Malfunctions and Battery Life of Cardiac Implantable Electronic Devices in Cancer Patients JF - Cancers N2 - Purpose: This study analyses a large number of cancer patients with CIEDs for device malfunction and premature battery depletion by device interrogation after each radiotherapy fraction and compares different guidelines in regard to patient safety. Methods: From 2007 to 2022, a cohort of 255 patients was analyzed for CIED malfunctions via immediate device interrogation after every RT fraction. Results: Out of 324 series of radiotherapy treatments, with a total number of 5742 CIED interrogations, nine device malfunctions (2.8%) occurred. Switching into back-up/safety mode and software errors occurred four times each. Once, automatic read-out could not be performed. The median prescribed cumulative dose at planning target volume (PTV) associated with CIED malfunction was 45.0 Gy (IQR 36.0–64.0 Gy), with a median dose per fraction of 2.31 Gy (IQR 2.0–3.0 Gy). The median maximum dose at the CIED at time of malfunction was 0.3 Gy (IQR 0.0–1.3 Gy). No correlation between CIED malfunction and maximum photon energy (p = 0.07), maximum dose at the CIED (p = 0.59) nor treatment localization (p = 0.41) could be detected. After excluding the nine malfunctions, premature battery depletion was only observed three times (1.2%). Depending on the national guidelines, 1–9 CIED malfunctions in this study would have been detected on the day of occurrence and in none of the cases would patient safety have been compromised. Conclusion: Radiation-induced malfunctions of CIEDs and premature battery depletion are rare. If recommendations of national safety guidelines are followed, only a portion of the malfunctions would be detected directly after occurrence. Nevertheless, patient safety would not be compromised. KW - battery depletion KW - cardiac implantable electronic devices (CIED) KW - cardiac resynchronization therapy (CRT) KW - implantable cardioverter defibrillator (ICD) KW - CIED malfunction; pacemaker (PM) KW - radiotherapy (RT) Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-358008 SN - 2072-6694 VL - 15 IS - 19 ER - TY - JOUR A1 - Lisowski, Dominik A1 - Trömel, Jannik A1 - Lutyj, Paul A1 - Lewitzki, Victor A1 - Hartrampf, Philipp E. A1 - Polat, Bülent A1 - Flentje, Michael A1 - Tamihardja, Jörg T1 - Health-related quality of life and clinical outcome after radiotherapy of patients with intracranial meningioma JF - Scientific Reports N2 - This retrospective, single-institutional study investigated long-term outcome, toxicity and health-related quality of life (HRQoL) in meningioma patients after radiotherapy. We analyzed the data of 119 patients who received radiotherapy at our department from 1997 to 2014 for intracranial WHO grade I-III meningioma. Fractionated stereotactic radiotherapy (FSRT), intensity modulated radiotherapy (IMRT) or radiosurgery radiation was applied. The EORTC QLQ-C30 and QLQ-BN20 questionnaires were completed for assessment of HRQoL. Overall survival (OS) for the entire study group was 89.6% at 5 years and 75.9% at 10 years. Local control (LC) at 5 and 10 years was 82.4% and 73.4%, respectively. Local recurrence was observed in 22 patients (18.5%). Higher grade acute and chronic toxicities were observed in seven patients (5.9%) and five patients (4.2%), respectively. Global health status was rated with a mean of 59.9 points (SD 22.3) on QLQ-C30. In conclusion, radiotherapy resulted in very good long-term survival and tumor control rates with low rates of severe toxicities but with a deterioration of long-term HRQoL. KW - CNS cancer KW - outcomes research KW - radiotherapy Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301233 VL - 12 ER - TY - JOUR A1 - Tamihardja, Jörg A1 - Lawrenz, Ingulf A1 - Lutyj, Paul A1 - Weick, Stefan A1 - Guckenberger, Matthias A1 - Polat, Bülent A1 - Flentje, Michael T1 - Propensity score-matched analysis comparing dose-escalated intensity-modulated radiation therapy versus external beam radiation therapy plus high-dose-rate brachytherapy for localized prostate cancer JF - Strahlentherapie und Onkologie N2 - Purpose Dose-escalated external beam radiation therapy (EBRT) and EBRT + high-dose-rate brachytherapy (HDR-BT) boost are guideline-recommended treatment options for localized prostate cancer. The purpose of this study was to compare long-term outcome and toxicity of dose-escalated EBRT versus EBRT + HDR-BT boost. Methods From 2002 to 2019, 744 consecutive patients received either EBRT or EBRT + HDR-BT boost, of whom 516 patients were propensity score matched. Median follow-up was 95.3 months. Cone beam CT image-guided EBRT consisted of 33 fractions of intensity-modulated radiation therapy with simultaneous integrated boost up to 76.23 Gy (D\(_{Mean}\)). Combined treatment was delivered as 46 Gy (D\(_{Mean}\)) EBRT, followed by two fractions HDR-BT boost with 9 Gy (D\(_{90\%}\)). Propensity score matching was applied before analysis of the primary endpoint, estimated 10-year biochemical relapse-free survival (bRFS), and the secondary endpoints metastasis-free survival (MFS) and overall survival (OS). Prognostic parameters were analyzed by Cox proportional hazard modelling. Genitourinary (GU)/gastrointestinal (GI) toxicity evaluation used the Common Toxicity Criteria for Adverse Events (v5.0). Results The estimated 10-year bRFS was 82.0% vs. 76.4% (p = 0.075) for EBRT alone versus combined treatment, respectively. The estimated 10-year MFS was 82.9% vs. 87.0% (p = 0.195) and the 10-year OS was 65.7% vs. 68.9% (p = 0.303), respectively. Cumulative 5‑year late GU ≥ grade 2 toxicities were seen in 23.6% vs. 19.2% (p = 0.086) and 5‑year late GI ≥ grade 2 toxicities in 11.1% vs. 5.0% of the patients (p = 0.002); cumulative 5‑year late grade 3 GU toxicity occurred in 4.2% vs. 3.6% (p = 0.401) and GI toxicity in 1.0% vs. 0.3% (p = 0.249), respectively. Conclusion Both treatment groups showed excellent long-term outcomes with low rates of severe toxicity. KW - long-term outcome KW - dose escalation KW - high-dose-rate brachytherapy boost KW - propensity score matching KW - toxicity Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-325055 VL - 198 IS - 8 ER - TY - JOUR A1 - Tamihardja, Jörg A1 - Lutyj, Paul A1 - Kraft, Johannes A1 - Lisowski, Dominik A1 - Weick, Stefan A1 - Flentje, Michael A1 - Polat, Bülent T1 - Two-Weekly High-Dose-Rate Brachytherapy Boost After External Beam Radiotherapy for Localized Prostate Cancer: Long-Term Outcome and Toxicity Analysis JF - Frontiers in Oncology N2 - Purpose Evaluation of clinical outcome of two-weekly high-dose-rate brachytherapy boost after external beam radiotherapy (EBRT) for localized prostate cancer. Methods 338 patients with localized prostate cancer receiving definitive EBRT followed by a two-weekly high-dose-rate brachytherapy boost (HDR-BT boost) in the period of 2002 to 2019 were analyzed. EBRT, delivered in 46 Gy (DMean) in conventional fractionation, was followed by two fractions HDR-BT boost with 9 Gy (D90%) two and four weeks after EBRT. Androgen deprivation therapy (ADT) was added in 176 (52.1%) patients. Genitourinary (GU)/gastrointestinal (GI) toxicity was evaluated utilizing the Common Toxicity Criteria for Adverse Events (version 5.0) and biochemical failure was defined according to the Phoenix definition. Results Median follow-up was 101.8 months. 15 (4.4%)/115 (34.0%)/208 (61.5%) patients had low-/intermediate-/high-risk cancer according to the D`Amico risk classification. Estimated 5-year and 10-year biochemical relapse-free survival (bRFS) was 84.7% and 75.9% for all patients. The estimated 5-year bRFS was 93.3%, 93.4% and 79.5% for low-, intermediate- and high-risk disease, respectively. The estimated 10-year freedom from distant metastasis (FFM) and overall survival (OS) rates were 86.5% and 70.0%. Cumulative 5-year late GU toxicity and late GI toxicity grade ≥ 2 was observed in 19.3% and 5.0% of the patients, respectively. Cumulative 5-year late grade 3 GU/GI toxicity occurred in 3.6%/0.3%. Conclusions Two-weekly HDR-BT boost after EBRT for localized prostate cancer showed an excellent toxicity profile with low GU/GI toxicity rates and effective long-term biochemical control. KW - prostate cancer KW - high-dose-rate (HDR) brachytherapy KW - radiotherapy KW - long-term outcome KW - toxicity KW - external beam radiotherapy (EBRT) KW - biochemical relapse free survival Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-250992 SN - 2234-943X VL - 11 ER - TY - JOUR A1 - Weick, Stefan A1 - Breuer, Kathrin A1 - Richter, Anne A1 - Exner, Florian A1 - Ströhle, Serge-Peer A1 - Lutyj, Paul A1 - Tamihardja, Jörg A1 - Veldhoen, Simon A1 - Flentje, Michael A1 - Polat, Bülent T1 - Non-rigid image registration of 4D-MRI data for improved delineation of moving tumors JF - BMC Medical Imaging N2 - Background To increase the image quality of end-expiratory and end-inspiratory phases of retrospective respiratory self-gated 4D MRI data sets using non-rigid image registration for improved target delineation of moving tumors. Methods End-expiratory and end-inspiratory phases of volunteer and patient 4D MRI data sets are used as targets for non-rigid image registration of all other phases using two different registration schemes: In the first, all phases are registered directly (dir-Reg) while next neighbors are successively registered until the target is reached in the second (nn-Reg). Resulting data sets are quantitatively compared using diaphragm and tumor sharpness and the coefficient of variation of regions of interest in the lung, liver, and heart. Qualitative assessment of the patient data regarding noise level, tumor delineation, and overall image quality was performed by blinded reading based on a 4 point Likert scale. Results The median coefficient of variation was lower for both registration schemes compared to the target. Median dir-Reg coefficient of variation of all ROIs was 5.6% lower for expiration and 7.0% lower for inspiration compared with nn-Reg. Statistical significant differences between the two schemes were found in all comparisons. Median sharpness in inspiration is lower compared to expiration sharpness in all cases. Registered data sets were rated better compared to the targets in all categories. Over all categories, mean expiration scores were 2.92 +/- 0.18 for the target, 3.19 +/- 0.22 for nn-Reg and 3.56 +/- 0.14 for dir-Reg and mean inspiration scores 2.25 +/- 0.12 for the target, 2.72 +/- 215 0.04 for nn-Reg and 3.78 +/- 0.04 for dir-Reg. Conclusions In this work, end-expiratory and inspiratory phases of a 4D MRI data sets are used as targets for non-rigid image registration of all other phases. It is qualitatively and quantitatively shown that image quality of the targets can be significantly enhanced leading to improved target delineation of moving tumors. KW - 4D-MRI KW - Non-rigid image registration KW - Radiotherapy treatment planning KW - Respiratory induced tumor motion Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229271 VL - 20 ER -