TY - JOUR A1 - Dietzsch, Stefan A1 - Braesigk, Annett A1 - Seidel, Clemens A1 - Remmele, Julia A1 - Kitzing, Ralf A1 - Schlender, Tina A1 - Mynarek, Martin A1 - Geismar, Dirk A1 - Jablonska, Karolina A1 - Schwarz, Rudolf A1 - Pazos, Montserrat A1 - Weber, Damien C. A1 - Frick, Silke A1 - Gurtner, Kristin A1 - Matuschek, Christiane A1 - Harrabi, Semi Ben A1 - Glück, Albrecht A1 - Lewitzki, Victor A1 - Dieckmann, Karin A1 - Benesch, Martin A1 - Gerber, Nicolas U. A1 - Obrecht, Denise A1 - Rutkowski, Stefan A1 - Timmermann, Beate A1 - Kortmann, Rolf-Dieter T1 - Types of deviation and review criteria in pretreatment central quality control of tumor bed boost in medulloblastoma—an analysis of the German Radiotherapy Quality Control Panel in the SIOP PNET5 MB trial JF - Strahlentherapie und Onkologie N2 - Purpose In Germany, Austria, and Switzerland, pretreatment radiotherapy quality control (RT-QC) for tumor bed boost (TB) in non-metastatic medulloblastoma (MB) was not mandatory but was recommended for patients enrolled in the SIOP PNET5 MB trial between 2014 and 2018. This individual case review (ICR) analysis aimed to evaluate types of deviations in the initial plan proposals and develop uniform review criteria for TB boost. Patients and methods A total of 78 patients were registered in this trial, of whom a subgroup of 65 patients were available for evaluation of the TB treatment plans. Dose uniformity was evaluated according to the definitions of the protocol. Additional RT-QC criteria for standardized review of target contours were elaborated and data evaluated accordingly. Results Of 65 initial TB plan proposals, 27 (41.5%) revealed deviations of target volume delineation. Deviations according to the dose uniformity criteria were present in 14 (21.5%) TB plans. In 25 (38.5%) cases a modification of the RT plan was recommended. Rejection of the TB plans was rather related to unacceptable target volume delineation than to insufficient dose uniformity. Conclusion In this analysis of pretreatment RT-QC, protocol deviations were present in a high proportion of initial TB plan proposals. These findings emphasize the importance of pretreatment RT-QC in clinical trials for MB. Based on these data, a proposal for RT-QC criteria for tumor bed boost in non-metastatic MB was developed. KW - brain tumor KW - pediatric KW - focal radiotherapy KW - quality assurance KW - individual case review Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-307812 SN - 0179-7158 SN - 1439-099X VL - 198 IS - 3 ER - TY - JOUR A1 - Rau, Markus A1 - Heindel, Tobias A1 - Unsleber, Sebastian A1 - Braun, Tristan A1 - Fischer, Julian A1 - Frick, Stefan A1 - Nauerth, Sebastian A1 - Schneider, Christian A1 - Vest, Gwenaelle A1 - Reitzenstein, Stephan A1 - Kamp, Martin A1 - Forchel, Alfred A1 - Höfling, Sven A1 - Weinfurter, Harald T1 - Free space quantum key distribution over 500 meters using electrically driven quantum dot single-photon sources-a proof of principle experiment JF - New Journal of Physics N2 - Highly efficient single-photon sources (SPS) can increase the secure key rate of quantum key distribution (QKD) systems compared to conventional attenuated laser systems. Here we report on a free space QKD test using an electrically driven quantum dot single-photon source (QD SPS) that does not require a separate laser setup for optical pumping and thus allows for a simple and compact SPS QKD system. We describe its implementation in our 500 m free space QKD system in downtown Munich. Emulating a BB84 protocol operating at a repetition rate of 125 MHz, we could achieve sifted key rates of 5-17 kHz with error ratios of 6-9% and g((2))(0)-values of 0.39-0.76. KW - QKD KW - electrically driven KW - free space KW - quantum dots KW - quantum key distribution Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-116760 VL - 16 IS - 043003 ER -