TY - JOUR A1 - Tsamadou, Chrysanthi A1 - Fürst, Daniel A1 - Vucinic, Vladan A1 - Bunjes, Donald A1 - Neuchel, Christine A1 - Mytilineos, Daphne A1 - Gramatzki, Martin A1 - Arnold, Renate A1 - Wagner, Eva Maria A1 - Einsele, Hermann A1 - Müller, Carlheinz A1 - Schrezenmeier, Hubert A1 - Mytilineos, Joannis T1 - Human leukocyte antigen-E mismatch is associated with better hematopoietic stem cell transplantation outcome in acute leukemia patients JF - Haematologica N2 - The immunomodulatory role of human leukocyte antigen (HLA)-E in hematopoietic stem cell transplantation (HSCT) has not been extensively investigated. To this end, we genotyped 509 10/10 HLA unrelated transplant pairs for HLA-E, in order to study the effect of HLA-E as a natural killer (NK)-alloreactivity mediator on HSCT outcome in an acute leukemia (AL) setting. Overall survival (OS), disease free survival (DFS), relapse incidence (RI) and non-relapse mortality (NRM) were set as endpoints. Analysis of our data revealed a significant correlation between HLA-E mismatch and improved HSCT outcome, as shown by both univariate (53% vs. 38%, P=0.002, 5-year OS) and multivariate (hazard ratio (HR)=0.63, confidence interval (CI) 95%=0.48–0.83, P=0.001) analyses. Further subgroup analysis demonstrated that the positive effect of HLA-E mismatch was significant and pronounced in advanced disease patients (n=120) (5-year OS: 50% vs. 18%, P=0.005; HR=0.40, CI 95%=0.22–0.72, P=0.002; results from univariate and multivariate analyses, respectively). The study herein is the first to report an association between HLA-E incompatibility and improved post–transplant prognosis in AL patients who have undergone matched unrelated HSCT. Combined NK and T cell HLA-E-mediated mechanisms may account for the better outcomes observed. Notwithstanding the necessity for in vitro and confirmational studies, our findings highlight the clinical relevance of HLA-E matching and strongly support prospective HLA-E screening upon donor selection for matched AL unrelated HSCTs. KW - medicine KW - acute leukemia (AL) KW - hematopoietic stem cell transplantation (HSCT) KW - human leukocyte antigen-E (HLA-E) KW - HLA-E matching KW - HSTC outcome Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-173325 VL - 102 IS - 11 ER - TY - JOUR A1 - Walter, Steffen A1 - Gruss, Sascha A1 - Neidlinger, Jana A1 - Stross, Isabelle A1 - Hann, Alexander A1 - Wagner, Martin A1 - Seufferlein, Thomas A1 - Walter, Benjamin T1 - Evaluation of an Objective Measurement Tool for Stress Level Reduction by Individually Chosen Music During Colonoscopy—Results From the Study “ColoRelaxTone” JF - Frontiers in Medicine N2 - Background and Aims: Colonoscopy as standard procedure in endoscopy is often perceived as uncomfortable for patients. Patient's anxiety is therefore a significant issue, which often lead to avoidance of participation of relevant examinations as CRC-screening. Non-pharmacological anxiety management interventions such as music might contribute to relaxation in the phase prior and during endoscopy. Although music's anxiolytic effects have been reported previously, no objective measurement of stress level reduction has been reported yet. Focus of this study was to evaluate the objective measurement of the state of relaxation in patients undergoing colonoscopy. Methods: Prospective study (n = 196) performed at one endoscopic high-volume center. Standard colonoscopy was performed in control group. Interventional group received additionally self-chosen music over earphones. Facial Electromyography (fEMG) activity was obtained. Clinician Satisfaction with Sedation Instrument (CSSI) and Patients Satisfaction with Sedation Instrument (PSSI) was answered by colonoscopists and patients, respectively. Overall satisfaction with music accompanied colonoscopy was obtained if applicable. Results: Mean difference measured by fEMG via musculus zygomaticus major indicated a significantly lower stress level in the music group [7.700(±5.560) μV vs. 4.820(±3.330) μV; p = 0.001]. Clinician satisfaction was significantly higher with patients listening to music [82.69(±15.04) vs. 87.3(±15.02) pts.; p = 0.001]. Patient's satisfaction was higher but did not differ significantly. Conclusions: We conclude that self-chosen music contributes objectively to a reduced stress level for patients and therefore subjectively perceived satisfaction for endoscopists. Therefore, music should be considered as a non-pharmacological treatment method of distress reduction especially in the beginning of endoscopic procedures. KW - colonoscopy KW - anxiety KW - stress level KW - music KW - relaxation Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-212337 VL - 7 ER - TY - JOUR A1 - Wagner-Drouet, Eva A1 - Teschner, Daniel A1 - Wolschke, Christine A1 - Schäfer-Eckart, Kerstin A1 - Gärtner, Johannes A1 - Mielke, Stephan A1 - Schreder, Martin A1 - Kobbe, Guido A1 - Hilgendorf, Inken A1 - Klein, Stefan A1 - Verbeek, Mareike A1 - Ditschkowski, Markus A1 - Koch, Martina A1 - Lindemann, Monika A1 - Schmidt, Traudel A1 - Rascle, Anne A1 - Barabas, Sascha A1 - Deml, Ludwig A1 - Wagner, Ralf A1 - Wolff, Daniel T1 - Comparison of cytomegalovirus-specific immune cell response to proteins versus peptides using an IFN-γ ELISpot assay after hematopoietic stem cell transplantation JF - Diagnostics N2 - Cytomegalovirus (CMV) infection is a major cause of morbidity and mortality following hematopoietic stem cell transplantation (HSCT). Measuring CMV-specific cellular immunity may improve the risk stratification and management of patients. IFN-γ ELISpot assays, based on the stimulation of peripheral blood mononuclear cells with CMV pp65 and IE-1 proteins or peptides, have been validated in clinical settings. However, it remains unclear to which extend the T-cell response to synthetic peptides reflect that mediated by full-length proteins processed by antigen-presenting cells. We compared the stimulating ability of pp65 and IE-1 proteins and corresponding overlapping peptides in 16 HSCT recipients using a standardized IFN-γ ELISpot assay. Paired qualitative test results showed an overall 74.4% concordance. Discordant results were mainly due to low-response tests, with one exception. One patient with early CMV reactivation and graft-versus-host disease, sustained CMV DNAemia and high CD8\(^+\) counts showed successive negative protein-based ELISpot results but a high and sustained response to IE-1 peptides. Our results suggest that the response to exogenous proteins, which involves their uptake and processing by antigen-presenting cells, more closely reflects the physiological response to CMV infection, while the response to exogenous peptides may lead to artificial in vitro T-cell responses, especially in strongly immunosuppressed patients. KW - CMV KW - CMV-specific cellular immunity KW - hematopoietic stem cell transplantation KW - recall antigen KW - peptide KW - immune monitoring KW - IFN-γ ELISpot KW - T cells KW - antigen processing and presentation KW - immunosuppression Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-228843 SN - 2075-4418 VL - 11 IS - 2 ER -