TY - JOUR A1 - Sherif, Mohammad A. A1 - Ince, Hüseyin A1 - Maniuc, Octavian A1 - Reiter, Therese A1 - Voelker, Wolfram A1 - Ertl, Georg A1 - Öner, Alper T1 - Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation JF - BMC Cardiovascular Disorders N2 - Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. Methods: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. Results: Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 +/- 4 years, and 25 patients (55.6 %) were female. Mean aortic annulus diameter was 20.3 +/- 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 +/- 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over-or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 % of patients. Conclusions: CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies. KW - multicenter KW - TAVI KW - impact KW - complex KW - anatomy KW - dimensions KW - regurgitation KW - root KW - sizing KW - echocardiography KW - multidetector computed-tomography KW - replacement KW - outcomes Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-136002 VL - 15 IS - 181 ER - TY - JOUR A1 - Sherif, Mohammad A. A1 - Herold, Joerg A1 - Voelker, Wolfram A1 - Maniuc, Octavian A1 - Ertl, Georg A1 - Praast, Christian A1 - Braun-Dullaeus, Ruediger Christian T1 - Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case-control study JF - BMC Cardiovascular Disorders N2 - Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. Methods: We analysed 124 patients who underwent successful TAVI using a self-expandable prosthesis, divided equally into two groups; in the study group we used the cross sectional short axis 2D-TEE for measurement of the aortic annulus and in the control group we used the long axis 2D-TEE. Results: Both groups were comparable regarding the clinical parameters. On the other hand, patients in the study group had less left ventricular ejection fraction (38.9 % versus 45.6 %, p = 0.01). The aortic valve annulus was, although not statistically significant, smaller in the study group (21.58 versus 23.28 mm, p = 0.25). Post procedural quantification of the aortic regurgitation revealed that only one patient in both groups had severe aortic regurgitation (AR), in this patient the valve was implanted deep. The incidence of significant AR was higher in the control group (29.0 % versus 12.9 %, p = 0.027). Conclusions: Sizing of the aortic valve annulus using cross-sectional 2D-TEE offers a safe and plausible method for patients undergoing TAVI using the self-expandable prosthesis and is significantly superior to using long axis 2D-TEE. KW - paravalvular regurgitation KW - multicenter KW - management KW - sizing KW - echocardiography KW - replacement KW - tomography KW - guidelines KW - outcomes KW - impact KW - recommendations KW - stenosis KW - TAVI Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-148328 VL - 15 IS - 78 ER - TY - JOUR A1 - Petri, Nils A1 - Lengenfelder, Björn A1 - Voelker, Wolfram A1 - Nordbeck, Peter T1 - Interventional closure of aortomitral perforation after TAVR: A case report JF - Catheterization and Cardiovascular Interventions N2 - Despite TAVR emerging as the gold standard for a broad spectrum of patients, it is associated with serious complications. In this report we present a case, where a TAVR procedure led to a perforation at the aortomitral continuity, discuss the risk factors for the occurrence of perforations and how we decided to treat the patient. KW - medicine KW - closure AV fistula/AVM (CLAV) KW - transcatheter valveimplantation (TVI) KW - percutaneous valve therapy (PVT) KW - aortic valve disease percutaneous intervention (AVDP) KW - imaging TTE/TEE (ITTE) Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-256625 VL - 98 IS - 3 ER - TY - JOUR A1 - Reiter, Theresa A1 - Demirbas, Senem A1 - Schmalzing, Marc A1 - Voelker, Wolfram A1 - Bauer, Wolfgang R. A1 - Güder, Gülmisal T1 - CMR detects extensive intracavitary thrombi as solitary clinical presentation of Antiphospholipid Syndrome: A case report JF - Clinical Case Reports N2 - Intracavitary thrombi are an important differential diagnosis of cardiac masses. Cardiac magnetic resonance imaging (CMR) allows their non-invasive characterization. This case highlights extensive cardiac thrombi detected by CMR as solitary presentation of antiphospholipid syndrome. KW - antiphospholipid syndrome KW - cardiac thrombi KW - CMR Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-312766 SN - 2050-0904 VL - 10 IS - 11 ER -