TY - JOUR A1 - Michalski, Kerstin A1 - Schlötelburg, Wiebke A1 - Hartrampf, Philipp E. A1 - Kosmala, Aleksander A1 - Buck, Andreas K. A1 - Hahner, Stefanie A1 - Schirbel, Andreas T1 - Radiopharmaceuticals for treatment of adrenocortical carcinoma JF - Pharmaceuticals N2 - Adrenocortical carcinoma (ACC) represents a rare tumor entity with limited treatment options and usually rapid tumor progression in case of metastatic disease. As further treatment options are needed and ACC metastases are sensitive to external beam radiation, novel theranostic approaches could complement established therapeutic concepts. Recent developments focus on targeting adrenal cortex-specific enzymes like the theranostic twin [\(^{123/131}\)I]IMAZA that shows a good image quality and a promising therapeutic effect in selected patients. But other established molecular targets in nuclear medicine such as the C-X-C motif chemokine receptor 4 (CXCR4) could possibly enhance the therapeutic regimen as well in a subgroup of patients. The aims of this review are to give an overview of innovative radiopharmaceuticals for the treatment of ACC and to present the different molecular targets, as well as to show future perspectives for further developments since a radiopharmaceutical with a broad application range is still warranted. KW - adrenocortical carcinoma KW - theranostics KW - endoradiotherapy KW - IMAZA Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-355901 SN - 1424-8247 VL - 17 IS - 1 ER - TY - JOUR A1 - Tutov, Anna A1 - Chen, Xinyu A1 - Werner, Rudolf A. A1 - Mühlig, Saskia A1 - Zimmermann, Thomas A1 - Nose, Naoko A1 - Koshino, Kazuhiro A1 - Lapa, Constantin A1 - Decker, Michael A1 - Higuchi, Takahiro T1 - Rationalizing the binding modes of PET radiotracers targeting the norepinephrine transporter JF - Pharmaceutics N2 - Purpose: A new PET radiotracer \(^{18}\)F-AF78 showing great potential for clinical application has been reported recently. It belongs to a new generation of phenethylguanidine-based norepinephrine transporter (NET)-targeting radiotracers. Although many efforts have been made to develop NET inhibitors as antidepressants, systemic investigations of the structure–activity relationships (SARs) of NET-targeting radiotracers have rarely been performed. Methods: Without changing the phenethylguanidine pharmacophore and 3-fluoropropyl moiety that is crucial for easy labeling, six new analogs of \(^{18}\)F-AF78 with different meta-substituents on the benzene-ring were synthesized and evaluated in a competitive cellular uptake assay and in in vivo animal experiments in rats. Computational modeling of these tracers was established to quantitatively rationalize the interaction between the radiotracers and NET. Results: Using non-radiolabeled reference compounds, a competitive cellular uptake assay showed a decrease in NET-transporting affinity from meta-fluorine to iodine (0.42 and 6.51 µM, respectively), with meta-OH being the least active (22.67 µM). Furthermore, in vivo animal studies with radioisotopes showed that heart-to-blood ratios agreed with the cellular experiments, with AF78(F) exhibiting the highest cardiac uptake. This result correlates positively with the electronegativity rather than the atomic radius of the meta-substituent. Computational modeling studies revealed a crucial influence of halogen substituents on the radiotracer–NET interaction, whereby a T-shaped π–π stacking interaction between the benzene-ring of the tracer and the amino acid residues surrounding the NET binding site made major contributions to the different affinities, in accordance with the pharmacological data. Conclusion: The SARs were characterized by in vitro and in vivo evaluation, and computational modeling quantitatively rationalized the interaction between radiotracers and the NET binding site. These findings pave the way for further evaluation in different species and underline the potential of AF78(F) for clinical application, e.g., cardiac innervation imaging or molecular imaging of neuroendocrine tumors. KW - positron emission tomography KW - norepinephrine transporter KW - sympathetic nervous system KW - structure–activity relationships KW - T-shaped π–π stacking Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-303949 SN - 1999-4923 VL - 15 IS - 2 ER - TY - JOUR A1 - Chen, Xinyu A1 - Kudo, Takashi A1 - Lapa, Constantin A1 - Buck, Andreas A1 - Higuchi, Takahiro T1 - Recent advances in radiotracers targeting norepinephrine transporter: structural development and radiolabeling improvements JF - Journal of Neural Transmission N2 - The norepinephrine transporter (NET) is a major target for the evaluation of the cardiac sympathetic nerve system in patients with heart failure and Parkinson's disease. It is also used in the therapeutic applications against certain types of neuroendocrine tumors, as exemplified by the clinically used \(^{123/131}\)I-MIBG as theranostic single-photon emission computed tomography (SPECT) agent. With the development of more advanced positron emission tomography (PET) technology, more radiotracers targeting NET have been reported, with superior temporal and spatial resolutions, along with the possibility of functional and kinetic analysis. More recently, fluorine-18-labelled NET tracers have drawn increasing attentions from researchers, due to their longer radiological half-life relative to carbon-11 (110 min vs. 20 min), reduced dependence on on-site cyclotrons, and flexibility in the design of novel tracer structures. In the heart, certain NET tracers provide integral diagnostic information on sympathetic innervation and the nerve status. In the central nervous system, such radiotracers can reveal NET distribution and density in pathological conditions. Most radiotracers targeting cardiac NET-function for the cardiac application consistent of derivatives of either norepinephrine or MIBG with its benzylguanidine core structure, e.g. \(^{11}\)C-HED and \(^{18}\)F-LMI1195. In contrast, all NET tracers used in central nervous system applications are derived from clinically used antidepressants. Lastly, possible applications of NET as selective tracers over organic cation transporters (OCTs) in the kidneys and other organs controlled by sympathetic nervous system will also be discussed. KW - norepinephrine transporter KW - benzylguanidine KW - phenethylguanidine KW - antidepressant KW - organic cation transporter Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-241148 VL - 127 ER - TY - JOUR A1 - Hartrampf, Philipp E. A1 - Krebs, Markus A1 - Peter, Lea A1 - Heinrich, Marieke A1 - Ruffing, Julia A1 - Kalogirou, Charis A1 - Weinke, Maximilian A1 - Brumberg, Joachim A1 - Kübler, Hubert A1 - Buck, Andreas K. A1 - Werner, Rudolf A. A1 - Seitz, Anna Katharina T1 - Reduced segmentation of lesions is comparable to whole-body segmentation for response assessment by PSMA PET/CT: initial experience with the keyhole approach JF - Biology N2 - Simple Summary The calculation of PSMA-positive tumor volume (PSMA-TV) of the whole body from PSMA PET scans for response evaluation remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative tumor lesions. Changes in the whole-body PSMA-TV of 65 patients were comparable to the changes in PSMA-TV after including only the ten largest lesions. Moreover, changes in PSMA-TV correlated well with changes in PSA levels, as did the changes in PSMA-TV with the reduced number of lesions. We conclude that a response assessment using PSMA-TV with a reduced number of lesions is feasible and could lead to a simplified process for evaluating PSMA PET/CT. Abstract (1) Background: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET)-derived parameters, such as the commonly used standardized uptake value (SUV) and PSMA-positive tumor volume (PSMA-TV), have been proposed for response assessment in metastatic prostate cancer (PCa) patients. However, the calculation of whole-body PSMA-TV remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative lesions. (2) Methods: Sixty-five patients classified into different disease stages were assessed by PSMA PET/CT for staging and restaging after therapy. Whole-body PSMA-TV and whole-body SUV\(_{max}\) were calculated. We then repeated this calculation only including the five or ten hottest or largest lesions. The corresponding serum levels of prostate-specific antigen (PSA) were also determined. The derived delta between baseline and follow-up values provided the following parameters: ΔSUV\(_{maxall}\), ΔSUV\(_{max10}\), ΔSUV\(_{max5}\), ΔPSMA-TV\(_{all}\), ΔPSMA-TV\(_{10}\), ΔPSMA-TV\(_{5}\), ΔPSA. Finally, we compared the findings from our whole-body segmentation with the results from our keyhole approach (focusing on a limited number of lesions) and correlated all values with the biochemical response (ΔPSA). (3) Results: Among patients with metastatic hormone-sensitive PCa (mHSPC), none showed a relevant deviation for ΔSUV\(_{max10}\)/ΔSUV\(_{max5}\) or ΔPSMA-TV\(_{10}\)/ΔPSMA-TV\(_{5}\) compared to ΔSUV\(_{maxall}\) and ΔPSMA-TV\(_{all}\). For patients treated with taxanes, up to 6/21 (28.6%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only up to 2/21 (9.5%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). For patients treated with radioligand therapy (RLT), up to 5/28 (17.9%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only 1/28 (3.6%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). The highest correlations with ΔPSA were found for ΔPSMA-TV\(_{all}\) (r ≥ 0.59, p ≤ 0.01), followed by ΔPSMA-TV\(_{10}\) (r ≥ 0.57, p ≤ 0.01) and ΔPSMA-TV\(_{5}\) (r ≥ 0.53, p ≤ 0.02) in all cohorts. ΔPSA only correlated with ΔSUV\(_{maxall}\) (r = 0.60, p = 0.02) and with ΔSUV\(_{max10}\) (r = 0.53, p = 0.03) in the mHSPC cohort, as well as with ΔSUV\(_{maxall}\) (r = 0.51, p = 0.01) in the RLT cohort. (4) Conclusion: Response assessment using PSMA-TV with a reduced number of lesions is feasible, and may allow for a simplified evaluation process for PSMA PET/CT. KW - PET/CT KW - PSMA-TV KW - SUV KW - prostate cancer KW - taxane KW - radioligand therapy Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-271191 SN - 2079-7737 VL - 11 IS - 5 ER - TY - JOUR A1 - Göring, Lukas A1 - Schumann, Sarah A1 - Müller, Jessica A1 - Buck, Andreas K. A1 - Port, Matthias A1 - Lassmann, Michael A1 - Scherthan, Harry A1 - Eberlein, Uta T1 - Repair of a-particle-induced DNA damage in peripheral blood mononuclear cells after internal ex vivo irradiation with \(^{223}\)Ra JF - European Journal of Nuclear Medicine and Molecular Imaging N2 - Purpose As α-emitters for radiopharmaceutical therapies are administered systemically by intravenous injection, blood will be irradiated by α-particles that induce clustered DNA double-strand breaks (DSBs). Here, we investigated the induction and repair of DSB damage in peripheral blood mononuclear cells (PBMCs) as a function of the absorbed dose to the blood following internal ex vivo irradiation with [\(^{223}\)Ra]RaCl2. Methods Blood samples of ten volunteers were irradiated by adding [\(^{223}\)Ra]RaCl2 solution with different activity concentrations resulting in absorbed doses to the blood of 3 mGy, 25 mGy, 50 mGy and 100 mGy. PBMCs were isolated, divided in three parts and either fixed directly (d-samples) or after 4 h or 24 h culture. After immunostaining, the induced γ-H2AX α-tracks were counted. The time-dependent decrease in α-track frequency was described with a model assuming a repair rate R and a fraction of non-repairable damage Q. Results For 25 mGy, 50 mGy and 100 mGy, the numbers of α-tracks were significantly increased compared to baseline at all time points. Compared to the corresponding d-samples, the α-track frequency decreased significantly after 4 h and after 24 h. The repair rates R were (0.24 ± 0.05) h−1 for 25 mGy, (0.16 ± 0.04) h−1 for 50 mGy and (0.13 ± 0.02) h−1 for 100 mGy, suggesting faster repair at lower absorbed doses, while Q-values were similar. Conclusion The results obtained suggest that induction and repair of the DSB damage depend on the absorbed dose to the blood. Repair rates were similar to what has been observed for irradiation with low linear energy transfer. KW - DSB damage KW - irradiation KW - α-Particle KW - γ-H2AX KW - repair Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324557 VL - 49 IS - 12 ER - TY - JOUR A1 - Aster, Hans-Christoph A1 - Romanos, Marcel A1 - Walitza, Susanne A1 - Gerlach, Manfred A1 - Mühlberger, Andreas A1 - Rizzo, Albert A1 - Andreatta, Marta A1 - Hasenauer, Natalie A1 - Hartrampf, Philipp E. A1 - Nerlich, Kai A1 - Reiners, Christoph A1 - Lorenz, Reinhard A1 - Buck, Andreas K. A1 - Deserno, Lorenz T1 - Responsivity of the striatal dopamine system to methylphenidate — A within-subject I-123-β-CIT-SPECT study in male children and adolescents with attention-deficit/hyperactivity disorder JF - Frontiers in Psychiatry N2 - Background: Methylphenidate (MPH) is the first-line pharmacological treatment of attention-deficit/hyperactivity disorder (ADHD). MPH binds to the dopamine (DA) transporter (DAT), which has high density in the striatum. Assessments of the striatal dopamine transporter by single positron emission computed tomography (SPECT) in childhood and adolescent patients are rare but can provide insight on how the effects of MPH affect DAT availability. The aim of our within-subject study was to investigate the effect of MPH on DAT availability and how responsivity to MPH in DAT availability is linked to clinical symptoms and cognitive functioning. Methods Thirteen adolescent male patients (9–16 years) with a diagnosis of ADHD according to the DSM-IV and long-term stimulant medication (for at least 6 months) with MPH were assessed twice within 7 days using SPECT after application of I-123-β-CIT to examine DAT binding potential (DAT BP). SPECT measures took place in an on- and off-MPH status balanced for order across participants. A virtual reality continuous performance test was performed at each time point. Further clinical symptoms were assessed for baseline off-MPH. Results On-MPH status was associated with a highly significant change (−29.9%) of striatal DAT BP as compared to off-MPH (t = −4.12, p = 0.002). A more pronounced change in striatal DAT BP was associated with higher off-MPH attentional and externalizing symptom ratings (Pearson r = 0.68, p = 0.01). Striatal DAT BP off-MPH, but not on-MPH, was associated with higher symptom ratings (Pearson r = 0.56, p = 0.04). Conclusion Our findings corroborate previous reports from mainly adult samples that MPH changes striatal DAT BP availability and suggest higher off-MPH DAT BP, likely reflecting low baseline DA levels, as a marker of symptom severity. KW - methylphenidate KW - attention deficit/hyperactivity disorder (ADHD) KW - striatum KW - single photon emission computed tomography (SPECT) KW - responsivity KW - caudate nucleus KW - dopamine transporter (DAT) Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-270862 SN - 1664-0640 VL - 13 ER - TY - JOUR A1 - Tamihardja, Jörg A1 - Zehner, Leonie A1 - Hartrampf, Philipp A1 - Lisowski, Dominik A1 - Kneitz, Susanne A1 - Cirsi, Sinan A1 - Razinskas, Gary A1 - Flentje, Michael A1 - Polat, Bülent T1 - Salvage nodal radiotherapy as metastasis-directed therapy for oligorecurrent prostate cancer detected by positron emission tomography shows favorable outcome in long-term follow-up JF - Cancers N2 - Simple Summary Patients, who suffer from oligorecurrent prostate cancer with limited nodal involvement, may be offered positron emission tomography (PET)-directed salvage nodal radiotherapy to delay disease progression. This current analysis aimed to access salvage radiotherapy for nodal oligorecurrent prostate cancer with simultaneous integrated boost to PET-involved lymph nodes as metastasis-directed therapy. A long-term oncological outcome was favorable after salvage nodal radiotherapy and severe toxicity rates were low. Androgen deprivation therapy plays a major role in recurrent prostate cancer management and demonstrates a positive influence on the rate of biochemical progression in patients receiving salvage nodal radiotherapy. The present long-term analysis may help clinicians identify patients who would benefit from salvage nodal radiotherapy and androgen deprivation therapy, as a multimodal treatment strategy for oligorecurrent prostate cancer. Abstract Background: The study aimed to access the long-term outcome of salvage nodal radiotherapy (SNRT) in oligorecurrent prostate cancer. Methods: A total of 95 consecutive patients received SNRT for pelvic and/or extrapelvic nodal recurrence after prostate-specific membrane antigen (PSMA) or choline PET from 2010 to 2021. SNRT was applied as external beam radiotherapy with simultaneous integrated boost up to a median total dose of 62.9 Gy (EQD2\(_{1.5Gy}\)) to the recurrent lymph node metastases. The outcome was analyzed by cumulative incidence functions with death as the competing risk. Fine–Gray regression analyses were performed to estimate the relative hazards of the outcome parameters. Genitourinary (GU)/gastrointestinal (GI) toxicity evaluation utilized Common Toxicity Criteria for Adverse Events (v5.0). The results are as follows: the median follow-up was 47.1 months. The five-year biochemical progression rate (95% CI) was 50.1% (35.7–62.9%). Concomitant androgen deprivation therapy (ADT) was adminstered in 60.0% of the patients. The five-year biochemical progression rate was 75.0% (42.0–90.9%) without ADT versus 35.3% (19.6–51.4%) with ADT (p = 0.003). The cumulative five-year late grade 3 GU toxicity rate was 2.1%. No late grade 3 GI toxicity occured. Conclusions: Metastasis-directed therapy through SNRT for PET-staged oligorecurrent prostate cancer demonstrated a favorable long-term oncologic outcome. Omittance of ADT led to an increased biochemical progression. KW - metastasis-directed therapy KW - long-term outcome KW - oligorecurrence KW - prostate cancer KW - salvage radiotherapy KW - PSMA Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-286064 SN - 2072-6694 VL - 14 IS - 15 ER - TY - JOUR A1 - Steinhardt, Maximilian Johannes A1 - Zhou, Xiang A1 - Krummenast, Franziska A1 - Meckel, Katharina A1 - Nickel, Katharina A1 - Böckle, David A1 - Messerschmidt, Janin A1 - Knorz, Sebastian A1 - Dierks, Alexander A1 - Heidemeier, Anke A1 - Lapa, Constantin A1 - Einsele, Hermann A1 - Rasche, Leo A1 - Kortüm, Klaus Martin T1 - Sequential CD38 monoclonal antibody retreatment leads to deep remission in a patient with relapsed/refractory multiple myeloma JF - International Journal of Immunopathology and Pharmacology N2 - We report on a currently 76-year-old female patient with relapsed/refractory (RR) multiple myeloma (MM) treated at our institution. This patient had received six lines of therapy including tandem autologous stem cell transplant, proteasome inhibitor, immunomodulatory drugs and CD38 antibody MOR202. At the last relapse, she progressed during treatment with pomalidomide and MOR202. In an individualized therapy concept, we started a multi-agent salvage therapy with pomalidomide, bortezomib, doxorubicin, dexamethasone, and CD38 antibody daratumumab (“Pom-PAD-Dara”), which resulted in a stringent complete remission with minimal residual disease (MRD) negativity after nine cycles. So far, our patient shows a progression free survival of more than 12 months. Our case demonstrates the feasibility of successful CD38 antibody retreatment in a patient with heavily pretreated CD38 antibody resistant MM. KW - CD38 KW - MOR202 KW - daratumumab KW - multiple myeloma KW - refractory KW - relapse Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-236235 VL - 34 ER - TY - JOUR A1 - Schneider, Peter T1 - SIRT Was Given Short Shrift JF - Deutsches Ärzteblatt International N2 - No abstract available. KW - heptacellular carcinoma Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-119564 VL - 111 IS - 26 ER - TY - THES A1 - Hoffmann, Jan Vincent T1 - Small-animal SPECT with Two Stationary Detectors: Performance Evaluation and Image Quality Assessment of Multi-pinhole Collimators T1 - Kleintier-SPECT mit Zwei Stationären Detektoren: Leistungsbewertung und Bildqualitätsanalyse von Multipinhole-Kollimatoren N2 - SPECT as a representative of molecular imaging allows visualization of metabolic processes in vivo. In clinical practice, single photon emission imaging is an established modality for myocardial perfusion imaging or the diagnosis of adrenal or neuroendocrine tumors, to name a few. With technical advances in scanner design and data processing leading to improved spatial resolution and image quality, SPECT has become a serious contender in small animal preclinical imaging. With multi-pinhole collimation, submillimeter spatial resolutions are achieved without limiting sensitivity, which has led to a significant increase of interest in SPECT for preclinical research in recent years. In this dissertation, the potential of a two-detector system through an analysis of three dedicated mouse collimators with multi-pinhole configurations was demonstrated. For this, sensitivity, spatial resolution, and uniformity as key parameters were determined. In the second part of the present work, an evaluation of the image quality at different activity concentrations to allow prediction of the system performance related to in vivo studies was performed. Therefore, a visual evaluation, as well as a calculation of the contrastto-noise ratio, was performed using mini Derenzo phantoms for the respective three mouse collimators. To better classify the results, the study was extended by a comparison with the predecessor system. Due to the absence of the third bottom detector, sensitivity and uniformity are slightly compromised. All three collimators were able to achieve a spatial resolution in the submillimeter range, XUHR-M offers a peak resolution of up to 0.35 mm. In terms of resolution, both evaluated systems performed on an equal level. Visual assessment of image quality indicates a slight advantage of the new two-detector system, and the contrast-to-noise ratio seems to benefit from the improved SROSEM algorithm. However, the differences between the two systems are marginal. The U-SPECT5/CT E-Class is proven to be state-of-the-art for small animal imaging and is a powerful instrument for preclinical molecular imaging research. Improvements in system design compensate well for the reduction in the detection area, allowing excellent imaging even with low activity concentrations. N2 - SPECT als Vertreter der molekularen Bildgebung ermöglicht die Visualisierung von Stoffwechselprozessen in vivo. In der klinischen Praxis ist die Einzelphotonen-Emissions-Bildgebung eine etablierte Modalität für die Myokard-Perfusions-Bildgebung oder die Diagnose von Nebennieren- oder neuroendokrinen Tumoren, um nur einige Beispiele zu nennen. Mit den technischen Fortschritten bei der Konstruktion von Scannern und der Datenverarbeitung, die zu einer verbesserten räumlichen Auflösung und Bildqualität führen, ist SPECT zu einem ernstzunehmenden Mitbewerber in der präklinischen Bildgebung von Kleintieren geworden. Unter der Verwendung von Multipinhole-Kollimatoren lassen sich Ortsauflösungen von unter einem Millimeter erzielen, ohne die Sensitivität deutlich einzuschränken. Dies trug dazu bei, dass das Interesse an SPECT in der präklinischen Forschung in den letzten Jahren zugenommen hat. In dieser Dissertation wurde das Potenzial eines Zweidetektorsystems unter Verwendung von drei Multipinhole-Mauskollimatoren evaluiert. Zur Leistungsbewertung wurde Sensitivität, Ortsauflösung und Homogenität bestimmt. Im zweiten Teil dieser Arbeit wurde eine Analyse der Bildqualität mit verschiedenen Aktivitätskonzentrationen durchgeführt, um eine Vorhersage der Leistung des Systems in In-vivo-Studien zu ermöglichen. Dazu wurde eine visuelle Bewertung sowie eine Berechnung des Kontrast-zu-Rausch-Verhältnisses mit Mini-Derenzo-Phantomen für die entsprechenden drei Mauskollimatoren durchgeführt. Um die Ergebnisse besser einordnen zu können, wurde die Studie um einen Vergleich mit dem Vorgängersystem erweitert. Durch das Fehlen des dritten unteren Detektors sind Sensitivität und Homogenität leicht beeinträchtigt. Alle drei Kollimatoren konnten eine Ortsauflösung unter einem Millimeter erreichen, wobei XUHR-M die höchste Auflösung von bis zu 0.35 mm erreicht. Die beiden untersuchten Systeme sind hinsichtlich der Ortsauflösung gleichwertig. Die visuelle Bewertung der Bildqualität deutet auf einen leichten, jedoch nur marginalen Vorteil des neuen Zweidetektorsystems hin, und das Kontrast-zu-Rausch-Verhältnis scheint von dem verbesserten SROSEM-Algorithmus zu profitieren. Das U-SPECT5/CT E-Class ist nachweislich auf dem neuesten Stand der Technik für die Bildgebung bei Kleintieren und ein leistungsfähiges Instrument für die präklinische Forschung. Das System kompensiert die Reduktion der Detektionsfläche und ermöglicht eine hervorragende Bildgebung auch bei geringen Aktivitätskonzentrationen. KW - SPECT KW - small-animal SPECT KW - performance evaluation KW - multi-pinhole collimation Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-328195 ER -