TY - JOUR A1 - Staab, Wieland A1 - Hottowitz, Ralf A1 - Sohns, Christian A1 - Sohns, Jan Martin A1 - Gilbert, Fabian A1 - Menke, Jan A1 - Niklas, Andree A1 - Lotz, Joachim T1 - Accelerometer and Gyroscope Based Gait Analysis Using Spectral Analysis of Patients with Osteoarthritis of the Knee JF - Journal of Physical Therapy Science N2 - [Purpose] A wide variety of accelerometer tools are used to estimate human movement, but there are no adequate data relating to gait symmetry parameters in the context of knee osteoarthritis. This study's purpose was to evaluate a 3D-kinematic system using body-mounted sensors (gyroscopes and accelerometers) on the trunk and limbs. This is the first study to use spectral analysis for data post processing. [Subjects] Twelve patients with unilateral knee osteoarthritis (OA) (10 male) and seven age-matched controls (6 male) were studied. [Methods] Measurements with 3-D accelerometers and gyroscopes were compared to video analysis with marker positions tracked by a six-camera optoelectronic system (VICON 460, Oxford Metrics). Data were recorded using the 3D-kinematic system. [Results] The results of both gait analysis systems were significantly correlated. Five parameters were significantly different between the knee OA and control groups. To overcome time spent in expensive post-processing routines, spectral analysis was performed for fast differentiation between normal gait and pathological gait signals using the 3D-kinematic system. [Conclusions] The 3D-kinematic system is objective, inexpensive, accurate and portable, and allows long-term recordings in clinical, sport as well as ergonomic or functional capacity evaluation (FCE) settings. For fast post-processing, spectral analysis of the recorded data is recommended. KW - gait KW - accelerometer KW - gyroscope KW - HIP osteoarthritis KW - kinematic analysis KW - human movement KW - in-vivo KW - artifact KW - systems KW - people Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-115907 VL - 26 IS - 7 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Horas, Konstantin A1 - Holzapfel, Boris M. A1 - Gilbert, Fabian A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre F. T1 - Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty JF - BMC Musculoskeletal Disorders N2 - Background For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA). Methods We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses. Results On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching. Conclusion The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system. KW - total knee replacement KW - knee axis KW - patient-specific knee arthroplasty KW - knee osteoarthritis KW - implant positioning Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230012 VL - 21 ER - TY - JOUR A1 - Holzapfel, Boris Michael A1 - Prodinger, Peter M. A1 - Pilge, Hakan A1 - Banke, Ingo J. A1 - Bürklein, Dominik A1 - Miethke, Thomas A1 - Gradinger, Reiner T1 - Acute Osteomyelitis of the Humerus mimicking Malignancy: Streptococcus pneumoniae as Exceptional Pathogen in an Immunocompetent Adult JF - BMC Infectious Diseases N2 - Background Chronic osteomyelitis due to direct bone trauma or vascular insufficiency is a frequent problem in orthopaedic surgery. In contrast, acute haematogenous osteomyelitis represents a rare entity that almost exclusively affects prepubescent children or immunodeficient adults. Case Presentation In this article, we report the case of acute pneumococcal osteomyelitis of the humerus in an immunocompetent and otherwise healthy 44-year-old male patient presenting with minor inflammation signs and misleading clinical features. Conclusions The diagnosis had to be confirmed by open biopsy which allowed the initiation of a targeted therapy. A case of pneumococcal osteomyelitis of a long bone, lacking predisposing factors or trauma, is unique in adults and has not been reported previously. KW - Acute osteomyelitis KW - Haematogenous KW - Long bones KW - Immunodeficiency KW - Osteomyelitis of the humerus Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-95790 ER - TY - JOUR A1 - Ebert, Regina A1 - Benisch, Peggy A1 - Krug, Melanie A1 - Zeck, Sabine A1 - Meißner-Weigl, Jutta A1 - Steinert, Andre A1 - Rauner, Martina A1 - Hofbauer, Lorenz A1 - Jakob, Franz T1 - Acute phase serum amyloid A induces proinflammatory cytokines and mineralization via toll-like receptor 4 in mesenchymal stem cells JF - Stem Cell Research N2 - The role of serum amyloid A (SAA) proteins, which are ligands for toll-like receptors, was analyzed in human bone marrow-derived mesenchymal stem cells (hMSCs) and their osteogenic offspring with a focus on senescence, differentiation andmineralization. In vitro aged hMSC developed a senescence-associated secretory phenotype (SASP), resulting in enhanced SAA1/2, TLR2/4 and proinflammatory cytokine (IL6, IL8, IL1\(\beta\), CXCL1, CXCL2) expression before entering replicative senescence. Recombinant human SAA1 (rhSAA1) induced SASP-related genes and proteins in MSC, which could be abolished by cotreatment with the TLR4-inhibitor CLI-095. The same pattern of SASP-resembling genes was stimulated upon induction of osteogenic differentiation, which is accompanied by autocrine SAA1/2 expression. In this context additional rhSAA1 enhanced the SASP-like phenotype, accelerated the proinflammatory phase of osteogenic differentiation and enhanced mineralization. Autocrine/paracrine and rhSAA1 via TLR4 stimulate a proinflammatory phenotype that is both part of the early phase of osteogenic differentiation and the development of senescence. This signaling cascade is tightly involved in bone formation and mineralization, but may also propagate pathological extraosseous calcification conditions such as calcifying inflammation and atherosclerosis. KW - human atherosclerotic lesions KW - senescence KW - expression KW - toll-like receptor KW - mineralization KW - osteogenic differentiation KW - serum amyloid A KW - inflammation KW - mesenchymal stem cells KW - WNT5A KW - model KW - lines KW - stromal cells KW - RT-PCR Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-148491 VL - 15 ER - TY - JOUR A1 - Hochleitner, Gernot A1 - Jüngst, Tomasz A1 - Brown, Toby D A1 - Hahn, Kathrin A1 - Moseke, Claus A1 - Jakob, Franz A1 - Dalton, Paul D A1 - Groll, Jürgen T1 - Additive manufacturing of scaffolds with sub-micron filaments via melt electrospinning writing JF - Biofabrication N2 - The aim of this study was to explore the lower resolution limits of an electrohydrodynamic process combined with direct writing technology of polymer melts. Termed melt electrospinning writing, filaments are deposited layer-by-layer to produce discrete three-dimensional scaffolds for in vitro research. Through optimization of the parameters (flow rate, spinneret diameter, voltage, collector distance) for poly-ϵ-caprolactone, we could direct-write coherent scaffolds with ultrafine filaments, the smallest being 817 ± 165 nm. These low diameter filaments were deposited to form box-structures with a periodicity of 100.6 ± 5.1 μm and a height of 80 μm (50 stacked filaments; 100 overlap at intersections). We also observed oriented crystalline regions within such ultrafine filaments after annealing at 55 °C. The scaffolds were printed upon NCO-sP(EO-stat-PO)-coated glass slide surfaces and withstood frequent liquid exchanges with negligible scaffold detachment for at least 10 days in vitro. KW - additive manufacturing KW - 3D printing KW - biodegradable polymers KW - microstructures KW - nanostructures Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-254053 VL - 7 IS - 3 ER - TY - THES A1 - Weissenberger [geb. Kunz], Manuela-Hermina T1 - Adenoviraler Gentransfer von SOX9 zur chondrogenen Differenzierung von humanen mesenchymalen Stammzellen T1 - Adenoviral gene transfer of SOX9 for chondrogenic differentiation of human mesenchymal stem cells N2 - Der adenovirale SOX9-Gentransfer induziert nach 3-wöchiger in vitro Pelletkultur die chondrogene Differenzierung humaner mesenchymaler Stammzellen in Pelletkultur wirksamer als der TGFB1 Gentransfer mit geringerer Chondrozytenhypertrophie. Eine solche Technologie könnte zukünftig in vivo die Bildung von stabilerem hyalinem Knorpelregeneratgewebe ermöglichen. N2 - Adenoviral SOX9 genetransfer in human mesenchymal stem cells can be used for chondrogenic differentiation and to generate stable hyaline cartilage regeneration in vitro in pellet culture system. KW - Hyaliner Knorpel KW - Adenoviraler Gentransfer KW - Knorpelregeneration KW - Stammzellen KW - chondrogene Differenzierung KW - SOX9 KW - Stammzelle Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-321221 ER - TY - THES A1 - Freytag, Andreas T1 - Adhärenz humanpathogener Staphylokokken auf orthopädischen Implantatmaterialien T1 - adherence of human pathogen staphylococci on orthopedic joint-prosthesis N2 - Die Anzahl an implantierten Gelenkendoprothesen hat in den letzten Jahrzehnten stark zugenommen. Mit ihr auch die Anzahl an Protheseninfektionen. Die Haupterreger sind Staphylokokken (>80%). Diese sind in vivo unempfindlich gegenüber Antibiotika und somit ist die einzige sinnvolle Therapie der Ausbau der infizierten Prothese, welcher lange und kostenspielige Krankenhausaufenthalte für den Patienten mit sich bringt. Der Grund für diese Resistenz der Bakterien liegt darin, dass sie zur Biofilmbildung fähig sind und sehr gut an Fremdkörper-Oberflächen adhärieren können. Welche Methode nun geeignet ist, die Adhärenz von Staphylokokken am besten unter klinisch relevanten Bedingungen zu untersuchen, ist zu prüfen. Das in der Arbeit entwickelte Modell ermöglicht eine semiquantitative Bestimmung der Adhärenz. Für die Versuche wurden Metallprüfkörper aus Titan und Kobalt-Chrom-Legierung verwendet. Zuvor wurden diese Metalle mit bestimmen Reinigungs- und Sterilisationsvorgängen gesäubert. Ein Teil der verwendeten Prüfkörper ist vor Beimpfung mit den Keimen durch Serumproteine bzw. Gewebsflüssigkeiten beschichtet worden, um das Anheftungsverhalten unter verschiedenen Bedingungen beurteilen zu können. Hierfür wurden Albumin, Kollagen Typ I und Typ II, Fibronektin und Fibrinogen verwendet. Sieben Titan-Prüfkörper sind in Schlieren (Schweiz) durch ein spezielles Verfahren mit PLL-g-PEG, einem Makromolekül welches die Adhäsion von Proteinen herabsetzt, beschichtet worden. Eine Auswirkung durch Infektionen sollte hierbei überprüft werden. Die Auswertung wurde unter REM-Betrachtung durchgeführt. Hierbei ist eine semiquantitative Abstufung der Adhärenzkraft von 1-5 getroffen worden. In den Ergebnissen zeigten die beiden verwendeten Metalle Titan und Kobalt-Chrom-Legierung keine wesentlichen Unterschiede in der gezeigten Adhärenz von Staphylokokken. Durch die Serumprotein- und Gewebsflüssigkeitsbeschichtung ließen sich Unterschiede unter verschiedenen Bedingungen feststellen. Fibronektin und Fibrinogen bewirken eine starke Zunahme an adhärenten Bakterienzellen. Kollagen Typ I und II zeigen eine leichte Adhärenzverstärkung und bewirken Biofilmbildung. Albuminbeschichtung reduziert die Anzahl adhärenter Staphylokokken. Die PLL-g-PEG Beschichtung löst starke Adhärenz und Biofilmbildung aus. Die hier angewandte Methode, kontaminierte Metallprüfkörper unter dem Rasterelektronenmikroskop zu betrachten, eignet sich um das Adhärenzverhalten von Bakterien zu beurteilen. Dabei lassen sich die Versuchsbedingungen auf vielfache Weise verändern. Verschiedene Metalle und andere Materialien können miteinander verglichen werden. Des Weiteren ist es möglich, unterschiedliche Proteinbeschichtungen vorzunehmen, um deren Einfluss auf die Adhärenz zu zeigen. Zusätzlich ist eine Durchführung der Versuche unter Bewegung möglich, was eine Annäherung an die Verhältnisse im menschlichen Körper bedeutet. Neben Staphylokokken könnten auch andere Bakterienspezies untersucht werden. In dieser Studie wird erstmals gezeigt, dass Kollagen eine Biofilmbildung bei Staphylokokken induziert. Dies bedarf weiterer Untersuchung, welcher Mechanismus hierfür verantwortlich ist. Die PLL-g-PEG Beschichtung hat auf Infektionen keine erfolgsversprechende Wirkung. Im Gegenteil, es kommt zu einer starken Besiedlung des Fremdmaterials. Albumin dagegen zeichnet sich durch eine Herabsetzung der Adhärenzstärke aus. Daraus könnte man therapeutischen Nutzen ziehen und Implantate vor Einbau mit Albumin beschichten. N2 - The number of orthopedic joint implantation has increased strongly within the last decades. With it also the number of implant infections. The main pathogenes are Staphylococci (> 80%). These are insensitive in vivo opposite antibiotics and therefore the only meaningful therapy is the removal of the infected artificial joint, which brings long and expensive hospital stays for the patients. On the one hand the reason for this resistance of the bacterias is biofilm formation and on the other hand the very well adherence on artifical surfaces. Which method is suitable now to examine the adherence of Staphylococci best under clinically relevant conditions has to be checked. The model developed in the work makes a semiquantitative determination of the adherence possible. For the tests metal test bodies of titanium and cobalt chrome are used. At first these metals were cleaned with special cleanings and sterilizations . A part of the used test bodies has been coated with serum proteins to judge the adherence under different conditions. Albumin, collagen type I and type II, fibronectin and fibrinogen were used for it. Seven titanium test bodies were coated in Schlieren (Switzerland) by a special method with PLL-g-PEG, a macro molecule, that reduces the adhesion of proteins. A consequence by infections should be checked at this. The evaluation was carried out under REM consideration. At it a semiquantitative layering of the adherence-power of 1-5 has been made. In the results the two used metals titanium and cobalt chrome alloying didn't show any essential differences in the shown adherence of Staphylococci. By the serum protein coatings differences could be stated under different conditions. Fibronectin and fibrinogen cause a strong increase to adherent bacterium cells. Collagen type I and II show low increase and cause biofilm formation. Albumin coating reduces the number of adherent bacterias. The PLL-g-PEG coating triggers strong adherence and biofilm formation. The method to look at contaminated metal test bodies under the REM used here is suitable to judge the adhesion behave of bacteria. At this the test conditions can be changed in a multiple way. Different metals and other materials can be compared with each other. Furthermore it is possible to carry out different protein coatings to show the influence on the adherence. An execution of the tests in addition is possible under movement, that approach towards the conditions in the human body. Also other bacterium species could be examined besides staphylococci. In this study it is shown for the first time that collagen induces a biofilm formation at staphylococci. This requires a further examination, which mechanism for it is responsible. The PLL-g-PEG coating doesn't have any success promising effect on infections. On the contrary, it comes to a strong settlement of the bacterias. Albumin however stands out due to a reduction of the adherence. A therapeutical use would be the coating of foreign bodies with albumin before implantation. KW - Staphylokokken KW - Adhärenz KW - orthopädische Implantate KW - Kollagen KW - Biofilm KW - staphylococci KW - biofilm KW - adherence KW - orthopedic joint prosthesis KW - collagen Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-14178 ER - TY - JOUR A1 - Rudert, Maximilian A1 - Holzapfel, Boris Michael A1 - Jakubietz, Michael T1 - Adjuvant Radiotherapy JF - Deutsches Ärzteblatt International N2 - No abstract available. KW - Soft-tissue sarcoma Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-133571 VL - 108 IS - 33 ER - TY - JOUR A1 - Trivanović, Drenka T1 - Adult stem cells in aging JF - Journal of Personalized Medicine N2 - No abstract available KW - adult stem cells Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-275226 SN - 2075-4426 VL - 12 IS - 5 ER - TY - THES A1 - von Rottkay, Eberhard T1 - Aktivität und Funktionalität nach Hüfttotalendoprothese über einen direkten anterioren Zugang verglichen mit einem gesunden Bevölkerungskollektiv T1 - Activity and functionality after total hip arthroplasty via direct anterior approach compared to a healthy population N2 - Die Möglichkeiten der operativen Rekonstruktion degenerativ veränderter Hüftgelenke sind komplex und vielfältig. Bei den derzeit zur Verfügung stehenden operativen Behandlungsmassnahmen führen die Vor- und Nachteile immer wieder zur Diskussionen und Abwägung der Operationsverfahren. Hierbei stehen sich die rasche postoperative Mobilisierung sowie eine verminderte Rekonvaleszenzzeit mit den diskutierten Nachteilen einer schlechteren Übersichtlichkeit und damit verbundenen Fehlimplantationen gegenüber. Dies und die damit verbundene volkswirtschaftliche Bedeutung sind ein ständiger Ausgangspunkt für das Bemühen den optimalen Zugangsweg zu etablieren. Daher stellte das von Smith-Peterson 1949 publizierte Verfahren einen Meilenstein in der operativen Therapie dar. Hierdurch konnten zum einen die operationstechnischen Vorteile wie auch das volkswirtschaftliche Begehren nach kürzeren postoperativen Verweildauern vereint werden. Die Modifizierung dieses Zugangsweges hat sich bereits in einer großen Anzahl prospektiver Studien als zuverlässiges Rekonstruktionsverfahren etabliert und erfüllt zudem auch die Anforderungen der heutigen Medizin nach ästhetisch schönen Ergebnissen. In der vorliegenden Arbeit wurde eine prospektive Fallstudie des direkten anterioren Zugangs mit einem gesunden Vergleichskollektiv durchgeführt. Mit dem Ziel, die Aktivität ein Jahr postoperativ nach Implantation einer HTEP mit gesunden Probanden zu vergleichen. Von Januar 2009 bis Mai 2011 wurden insgesamt 77 Patienten und 59 Probanden in die Studie aufgenommen. Als Vergleichswerte wurde zum einen die klinische wie auch die radiologische Untersuchung herangezogen. In der klinischen Untersuchung zeigte sich insgesamt ein signifikanter Anstieg der untersuchten Scores im Vergleich mit den präoperativen Ergebnissen bei den Operierten. Im Vergleich zu den Probanden erzielen die Patienten ein Jahr nach HTEP teilweise noch schlechtere Werte in dem Bewegungsumfang und den Aktivitätsniveaus welche mittels der Auswertung des Stepwatches, des TWB und des Arzt-Patienten-Fragebogens erhoben wurden. Die radiologische Bewertung diente zur Feststellung der Positionierung der HTEP. Mit guten Positionierungen durch den direkten anterioren Zugang. Die Bewertung der Funktionalität zwischen den beiden Gruppen erfolgte durch den HHS, XSFMA- D und den Arzt-Patientenfragenbogen. Hierbei konnten ähnliche Ergebnisse, wie bereits oben beschrieben, verzeichnet werden mit guten Werten in der Gruppe der untersuchten Patienten, jedoch einer geringeren Funktionalität im Vergleich zu den Probanden. Die vorliegende Arbeit zeigt, dass der direkte anteriore Zugang die Wiederherstellung eines guten postoperativen Gesundheitszustandes mit erreichen eines hohen postoperativen Aktivitätslevels der Patienten ermöglicht. Ebenso erfüllt dieser Zugangsweg die Anforderungen der heutigen Medizin im Sinne einer schnellen postoperativen Mobilisation. Im Vergleich zu anderen minimal-invasiven Verfahren zeigen sich eine gute Implantierbarkeit, eine gute Positionierung und ein niedriges Komplikationsniveau. Prinzipiell hat der minimal-invasive anteriore Zugang das Potenzial sich als ein Standardverfahren in der operativen Rekonstruktion bei Hüftgelenksersatz zu etablieren, jedoch wäre ein direkter Vergleich mit dem lateralen Zugang erstrebenswert und sollte in weiteren Studien verglichen werden. N2 - Background: The aim of this prospectve study was to evaluate the clinical results one year after total hip arthroplasty performed through a minimally invasive direct anterior approach versus a healthy volunteer group. Methods: 77 patients and 59 probands have been evaltuated applying the Stepwatch activity monitor (SAM), the Harris hip score (HHS), the SF 36, a daliy activity questionnaire (DAQ) and the XSFMA. Results: The average SAM showed significant differences of 5658 steps (patients) compared to 6417 steps (proband) (p=0,011). The same routcome can be seen in the DAQ with 4226 (patients) and 4686 (proband) cycles (p=0,327) respectively. No significant difference occured by using the average HHS reflecting an equal outcome of 90,7 points in the patient group compared to 90.8 points in the proband group (p=0,022). In contrast tot he afore-mentioned HHS, was a significant increase of the XSFMA reported with 10,9 (patients) and 5.0 (proband) (p=0,001). The SF -36 physical component scores were 45.8 (patients) and 50.6 (proband) while the psychometric properties added up to 56.6 (patients) and 55.9 (proband). While the physical component scores (p=0,001) showed a significant difference this couldnt be observed for the psychometric properties (p=0,511). Conclusion: In our study, good results have been obtained after the first year of the total hip arthroplasty, however these are not as beneficial as the outcomes in the healthy volunteer group. KW - AMIS KW - Direct anterior approach KW - hip arthroplasty KW - stepwatch KW - comparison KW - AMIS KW - Direct anterior approach KW - hip arthroplasty KW - stepwatch KW - comparison Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-178206 N1 - Dieses Dokument wurde aus Urheberrechtsschutzgründen erneut veröffentlicht. Die ursprüngliche Veröffentlichung war am 18.01.2016. ER - TY - THES A1 - von Rottkay, Eberhard T1 - Aktivität und Funktionalität nach Hüfttotalendoprothese über einen direkten anterioren Zugang verglichen mit einem gesunden Bevölkerungskollektiv T1 - Activity and functionality after total hip arthroplasty via direct anterior approach compared to a healthy population N2 - Die Möglichkeiten der operativen Rekonstruktion degenerativ veränderter Hüftgelenke sind komplex und vielfältig. Bei den derzeit zur Verfügung stehenden operativen Behandlungsmassnahmen führen die Vor- und Nachteile immer wieder zur Diskussionen und Abwägung der Operationsverfahren. Hierbei stehen sich die rasche postoperative Mobilisierung sowie eine verminderte Rekonvaleszenzzeit mit den diskutierten Nachteilen einer schlechteren Übersichtlichkeit und damit verbundenen Fehlimplantationen gegenüber. Dies und die damit verbundene volkswirtschaftliche Bedeutung sind ein ständiger Ausgangspunkt für das Bemühen den optimalen Zugangsweg zu etablieren. Daher stellte das von Smith-Peterson 1949 publizierte Verfahren einen Meilenstein in der operativen Therapie dar. Hierdurch konnten zum einen die operationstechnischen Vorteile wie auch das volkswirtschaftliche Begehren nach kürzeren postoperativen Verweildauern vereint werden. Die Modifizierung dieses Zugangsweges hat sich bereits in einer großen Anzahl prospektiver Studien als zuverlässiges Rekonstruktionsverfahren etabliert und erfüllt zudem auch die Anforderungen der heutigen Medizin nach ästhetisch schönen Ergebnissen. In der vorliegenden Arbeit wurde eine prospektive Fallstudie des direkten anterioren Zugangs mit einem gesunden Vergleichskollektiv durchgeführt. Mit dem Ziel, die Aktivität ein Jahr postoperativ nach Implantation einer HTEP mit gesunden Probanden zu vergleichen. Von Januar 2009 bis Mai 2011 wurden insgesamt 77 Patienten und 59 Probanden in die Studie aufgenommen. Als Vergleichswerte wurde zum einen die klinische wie auch die radiologische Untersuchung herangezogen. In der klinischen Untersuchung zeigte sich insgesamt ein signifikanter Anstieg der untersuchten Scores im Vergleich mit den präoperativen Ergebnissen bei den Operierten. Im Vergleich zu den Probanden erzielen die Patienten ein Jahr nach HTEP teilweise noch schlechtere Werte in dem Bewegungsumfang und den Aktivitätsniveaus welche mittels der Auswertung des Stepwatches, des TWB und des Arzt-Patienten-Fragebogens erhoben wurden. Die radiologische Bewertung diente zur Feststellung der Positionierung der HTEP. Mit guten Positionierungen durch den direkten anterioren Zugang. Die Bewertung der Funktionalität zwischen den beiden Gruppen erfolgte durch den HHS, XSFMA- D und den Arzt-Patientenfragenbogen. Hierbei konnten ähnliche Ergebnisse, wie bereits oben beschrieben, verzeichnet werden mit guten Werten in der Gruppe der untersuchten Patienten, jedoch einer geringeren Funktionalität im Vergleich zu den Probanden. Die vorliegende Arbeit zeigt, dass der direkte anteriore Zugang die Wiederherstellung eines guten postoperativen Gesundheitszustandes mit erreichen eines hohen postoperativen Aktivitätslevels der Patienten ermöglicht. Ebenso erfüllt dieser Zugangsweg die Anforderungen der heutigen Medizin im Sinne einer schnellen postoperativen Mobilisation. Im Vergleich zu anderen minimal-invasiven Verfahren zeigen sich eine gute Implantierbarkeit, eine gute Positionierung und ein niedriges Komplikationsniveau. Prinzipiell hat der minimal-invasive anteriore Zugang das Potenzial sich als ein Standardverfahren in der operativen Rekonstruktion bei Hüftgelenksersatz zu etablieren, jedoch wäre ein direkter Vergleich mit dem lateralen Zugang erstrebenswert und sollte in weiteren Studien verglichen werden. N2 - Background: The aim of this prospectve study was to evaluate the clinical results one year after total hip arthroplasty performed through a minimally invasive direct anterior approach versus a healthy volunteer group. Methods: 77 patients and 59 probands have been evaltuated applying the Stepwatch activity monitor (SAM), the Harris hip score (HHS), the SF 36, a daliy activity questionnaire (DAQ) and the XSFMA. Results: The average SAM showed significant differences of 5658 steps (patients) compared to 6417 steps (proband) (p=0,011). The same routcome can be seen in the DAQ with 4226 (patients) and 4686 (proband) cycles (p=0,327) respectively. No significant difference occured by using the average HHS reflecting an equal outcome of 90,7 points in the patient group compared to 90.8 points in the proband group (p=0,022). In contrast tot he afore-mentioned HHS, was a significant increase of the XSFMA reported with 10,9 (patients) and 5.0 (proband) (p=0,001). The SF -36 physical component scores were 45.8 (patients) and 50.6 (proband) while the psychometric properties added up to 56.6 (patients) and 55.9 (proband). While the physical component scores (p=0,001) showed a significant difference this couldnt be observed for the psychometric properties (p=0,511). Conclusion: In our study, good results have been obtained after the first year of the total hip arthroplasty, however these are not as beneficial as the outcomes in the healthy volunteer group. KW - AMIS, Direct anterior approach, hip arthroplasty, stepwatch, comparison KW - AMIS, Direct anterior approach, hip arthroplasty, stepwatch, comparison Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-123448 N1 - Aus urheberrechtlichen Gründen wurde der Zugriff auf den Volltext zu diesem Dokument gesperrt. Eine neue Version ist erhältlich unter: urn:nbn:de:bvb:20-opus-178206 ER - TY - THES A1 - Kranz, Julius Fabian T1 - Aktivität, Funktionalität und Lebensqualität sechs Wochen nach Hüftprothesenimplantation über den klassischen transglutealen (lateralen) OP-Zugang nach Bauer T1 - Activity, functionality and quality of life six weeks after total hip arthroplasty via the classic transgluteal (lateral) approach according to Bauer N2 - Einführung Der laterale Zugang nach Bauer ist weiterhin einer der etabliertesten Standardzugänge für die Hüftendoprothetik in Deutschland und weltweit. Im Zuge der Entwicklung in Richtung „Fast-Track“ Endoprothetik gewinnt die frühe postoperative Phase zunehmend an Bedeutung. Material und Methoden: Die vorliegende Arbeit untersucht die Ergebnisse des lateralen OP-Zugangs bis sechs Wochen postoperativ, die in einer übergeordneten prospektiv randomisierten Studie zum Vergleich des lateralen mit dem anterioren MIS-Zugangs erhoben wurden. Diese Studie wurde bereits international publiziert. In der vorliegenden Arbeit sollte ermittelt werden, welche Änderungen sich in den Outcome-Kriterien Aktivität, Funktion und Lebensqualität durch den lateralen Zugang bis sechs Wochen postoperativ ergeben. Hierfür wurden neben den etablierten Scores HHS, AP, SF-36 und PHQ-D der Aktivitätsscore TWB sowie der Funktionsscore XSMFA-D erstmalig in der frühen postoperativen Phase eingesetzt. Ergebnisse: Maßgeblich für die Bewertung der Ergebnisqualität sind neben den Ergebnissen der Scores auch die intra- und postoperativen Komplikationen, welche auf einem vergleichsweise niedrigen Niveau waren. 7,5 % der Patienten mit lateralem Zugang zeigten Hinweise für eine Schwächung der Hüftabduktoren, die häufig mit dem transglutealen Zugangsweg in Verbindung gebracht wird. Der laterale Zugang konnte bis sechs Wochen postoperativ und auch im Gesamtkontext der Studie nicht mit einem erhöhten peri- und postoperativen Komplikationsrisiko in Zusammenhang gebracht werden. Das Outcome in Aktivität, Funktion und Lebensqualität zeigte im prä- und postoperativen W6-Vergleich signifikante Zunahmen in den Scores HHS, XSMFA-D, SF-36 und AP mit hohen Korrelationen untereinander und jeweils anhand der Score-Outcome-Kriterien und im Literaturvergleich guten bis sehr guten Ergebnissen. Dies trifft ebenfalls auf den Einsatz des StepWatch™ präoperativ und im weiteren Verlauf der Studie zu. Im Gesamtkontext der bereits publizierten übergeordneten Studie konnten jedoch für den MIS-Zugang in einzelnen Scores bessere Ergebnisse in den Outcome-Kategorien erzielt werde. Schlussfolgerungen: Die Ergebnisse des erstmalig früh postoperativ eingesetzten TWB lassen die Eignung des Scores zur validen Datenerhebung unter diesen Bedingungen fraglich erscheinen. Eine evtl. Revalidierung des TWB sollte deshalb, bei Bestätigung der vorliegenden Beobachtungen im weiteren klinischen Gebrauch in Betracht gezogen werden. Auch der PHQ-D konnte seine in der Literatur beschriebene Eignung zur postoperativen Datenerhebung von psychischen Komorbitäten bei chirurgischen Patienten bis W6 nicht unterstreichen. Im Gegensatz zu TWB und PHQ-D hat sich der erstmalige Einsatz des XSMFA-D im frühen Nachuntersuchungsintervall bewährt. Es konnten Verbesserungen für Funktion und Beeinträchtigung sechs Wochen postoperativ bereits auf vergleichbarem Niveau wie zu den späteren Nachuntersuchungen ermittelt werden. Schlussfolgern lässt sich, dass die frühe postoperative Phase eine in der klinischen Bedeutung und postoperativen Ergebnisbeurteilung zunehmend wichtige Zwischenstation darstellt, bei der die bis dort in den Outcome-Kriterien Aktivität, Funktion und Lebensqualität auftretenden signifikanten Verbesserungen auch Rückschlüsse auf die weitere Prognose und Outcome-Entwicklung zulassen. Der in der vorliegenden Arbeit speziell untersuchte laterale OP-Zugang konnte im Gesamtkontext der übergeordneten prospektiven randomisierten Studie die Ergebnisqualität des MIS-Verfahrens sechs Wochen postoperativ nicht erreichen. Die Ergebnisqualität des lateralen Zugangs zur Behandlung der Coxarthrose ist aber anhand der Score-Outcome-Kriterien und den verglichenen Literaturergebnissen bis sechs Wochen postoperativ dennoch als gut zu bewerten. Vorteilhaft und von Bedeutung sind diese Erkenntnisse insbesondere für diejenigen Patienten, welche nicht für das MIS-Verfahren, sondern den lateralen OP-Zugang in Frage kommen. N2 - Introduction: The lateral approach according to Bauer continues to be one of the most established standard approaches for hip arthroplasty in Germany and worldwide. In the course of the development towards "fast-track" endoprosthetics, the early postoperative phase is becoming increasingly important. Material and methods: The present study examines the results of the lateral approach up to six weeks postoperatively, which were collected in a superordinate prospective randomized study comparing lateral and anterior MIS approach. This study has already been published internationally. The aim of the present study was to determine changes in the outcome criteria of activity, function and quality of life result after lateral approach up to six weeks postoperatively. In addition to the established scores HHS, AP, SF-36 and PHQ-D, the activity score TWB and the functional score XSMFA-D were used for the first time in the early postoperative period. Results: In addition to the results of the scores, the intraoperative and postoperative complications, which were at a comparatively low level, were decisive for the evaluation of the outcome quality. 7.5% of patients with lateral access showed signs of weakening of the hip abductors, which is often associated with the transgluteal approach. The lateral approach could not be associated with an increased risk of peri-and postoperative complications until six weeks postoperatively and also in the overall context of the study.The outcome in terms of activity, function and quality of life in the pre- and postoperative W6 comparison showed significant increases in the scores HHS, XSMFA-D, SF-36 and AP with high correlations and very good results according to the score-outcome criteria and in the literature comparison. This also applies to the use of StepWatch™ preoperatively and during the whole study. In the overall context of the already published long-term study, however, better results in the outcome categories could be achieved for the MIS approach in individual scores. Conclusions: The results of the TWB, which was used for the first time in the early postoperative phase, make the suitability of the scores for valid data collection under these conditions questionable. A possible revalidation of the TWB should therefore be considered when the present observations are confirmed in further clinical use. The PHQ-D was also unable to underline its suitability for postoperative data collection of psychic comorbidities in surgical patients up to W6. In contrast to TWB and PHQ-D, the first use of the XSMFA-D in the early follow-up interval has proven itself. Improvements in function and impairment could be identified six weeks postoperatively at a comparable level as at the later follow - up examinations.It can be concluded that the early postoperative phase is an increasingly important part in the clinical significance and postoperative evaluation of results. The significant improvements in the outcome criteria activity, function and quality of life also allow conclusions about the further prognosis and outcome development. In the overall context of the superordinate prospective randomized study, the specifically examined lateral approach could not achieve the outcome quality of the MIS approach six weeks postoperatively. However, the outcome quality of lateral approach to the treatment of osteoarthritis of the hip joint can still be assessed as good based on the score-outcome criteria and the compared literature results up to six weeks postoperatively. These findings might be important in particular for those patients who are not candidates for the MIS procedure but for the lateral approach during total hip joint arthroplasty. KW - Hüftgelenk KW - Totalendoprothese KW - Operationstechnik KW - Körperliche Aktivität KW - Therapieerfolg KW - Hip arthroplasty Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-192573 ER - TY - THES A1 - Kaufmann, Katharina T1 - Aktivitätsverlauf, Funktionsstatus und Lebensqualität nach minimal-invasivem anteriorem Zugang bei Hüfttotalendoprothesen T1 - Activity, functionality outcome and health-related quality of life using a minimally invasive anterior approach for total hip arthroplasty N2 - Die Studie untersucht Aktivitätsverlauf, Funktionsstatus und Lebensqualität nach minimal-invasivem anteriorem Zugang bei Hüfttotalendoprothesen (präoperativ bis sechs Wochen postoperativ) mit Hilfe der Fragebögen PHQ-D, XSMFA-D, SF-36, HHS, Täglicher Würzburger Aktivitätsfragebogen, Arzt- u. Patientenbogen Hüfte. N2 - This clinical study investigates activity, functionality outcome and health-related quality of life using a minimally invasive anterior approach for total hip arthroplasty (preoperatively up to six weeks postoperatively) using questionnaires inter alia PHQ-D, XSMFA-D, SF-36, HHS, Daily activity questionnaire (DAQ). KW - Endoprothese KW - Hüftgelenk KW - Klinisches Experiment KW - Aktivität KW - Funktion KW - Lebensqualität KW - minimal-invasiv KW - anteriorer Zugang KW - activity KW - functionality outcome KW - health-related quality of life KW - minimally invasive anterior approach KW - total hip arthroplasty Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-81583 ER - TY - JOUR A1 - Holzapfel, Boris Michael A1 - Rechl, Hans A1 - Lehner, Stefan A1 - Pilge, Hakan A1 - Gollwitzer, Hans A1 - Steinhauser, Erwin T1 - Alloplastic Reconstruction of the Extensor Mechanism after Resection of Tibial Sarcoma [Research Article] N2 - Reconstruction of the extensor mechanism is essential for good extremity function after endoprosthetic knee replacement following tumor resection. Only a few biological methods have been able to reliably restore a functional extensor mechanism, but they are often associated with significant complication rates. Reattachment of the patellar tendon to the prosthesis using an alloplastic patellar ligament (Trevira cord) can be an appropriate alternative. In vivo and in vitro studies have already shown that complete fibrous ingrowth in polyethylene chords can be seen after a period of six months. However, until now, no biomechanical study has shown the efficacy of an alloplastic cord and its fixation device in providing sufficient stability and endurance in daily life-activity until newly formed scar tissue can take over this function. In a special test bench developed for this study, different loading regimes were applied to simulate loads during everyday life. Failure loads and failuremodes were evaluated. The properties of the cord were compared before and after physiological conditioning. It was shown that rubbing was the mode of failure under dynamic loading. Tensile forces up to 2558N did not result in material failure. Thus, using an artificial cord together with this fixation device, temporary sufficient stable fixation can be expected. KW - Medizin Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-69072 ER - TY - JOUR A1 - Nedopil, Alexander J. A1 - Shekhar, Adithya A1 - Howell, Stephen M. A1 - Hull, Maury L. T1 - An insert with less than spherical medial conformity causes a loss of passive internal rotation after calipered kinematically aligned TKA JF - Archives of Orthopaedic and Trauma Surgery N2 - Introduction In total knee arthroplasty (TKA), the level of conformity, a medial stabilized (MS) implant, needs to restore native (i.e., healthy) knee kinematics without over-tensioning the flexion space when the surgeon chooses to retain the posterior cruciate ligament (PCL) is unknown. Whether an insert with a medial ball-in-socket conformity and lateral flat surface like the native knee or a less than spherical medial conformity restores higher and closer to native internal tibial rotation without anterior lift-off, an over-tension indicator, when implanted with calipered kinematic alignment (KA), is unknown. Methods and Materials Two surgeons treated 21 patients with calipered KA and a PCL retaining MS implant. Validated verification checks that restore native tibial compartment forces in passive flexion without release of healthy ligaments were used to select the optimal insert thickness. A goniometer etched onto trial inserts with the ball-in-socket and the less than spherical medial conformity measured the tibial rotation relative to the femoral component at extension and 90° and 120° flexion. The surgeon recorded the incidence of anterior lift-off of the insert. Results The insert with the medial ball-in-socket and lateral flat surface restored more internal tibial rotation than the one with less than spherical medial conformity, with mean values of 19° vs. 17° from extension to 90° flexion (p < 0.01), and 23° vs. 20°-120° flexion (p < 0.002), respectively. There was no anterior lift-off of the insert at 90° and 120° flexion. Conclusion An MS insert with a medial ball-in-socket and lateral flat surface that matches the native knee's spherical conformity restores native tibial internal rotation when implanted with calipered KA and PCL retention without over-tensioning the flexion space. KW - calipered KW - medial stabilized KW - spherical KW - conforming KW - insert KW - rotation KW - total knee arthroplasty KW - total knee replacement KW - kinematic alignment Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-266710 SN - 1434-3916 VL - 141 IS - 12 ER - TY - THES A1 - Dörries, Susanne T1 - Analyse der Gründe für Revisionsoperationen bei einliegender Knieprothese T1 - Analysis of the reasons for revision surgery with inserted knee arthroplasty N2 - Die Knieendoprothetik verzeichnet in den letzten Jahren steigende Zahlen, was wiederum steigende Zahlen an Revisionen zur Folge hat. Diese Studie hat die Gründe für Revisionen ermittelt. Hierzu wurden 1245 Operationen gesammelt und ausgewertet. Instabilität, Infektion und aseptische Lockerungen stellen die Hauptgründe für eine Revisionsoperation dar. Es wurden zusätzlich verschiedene Zeiträume zwischen Primärimplantation und Revision unterteilt und die jeweiligen Gründe ermittelt. N2 - Recent years have shown an increasing number of knee arthroplasty implantations with raising numbers of revisions as a result. This study has investigated into the reasons of revisions. For this purpose 1245 operations were collected and evaluated. Instability, periprosthetic infection and aseptic loosening are the main reasons for revision surgery. In addition, different time periods between primary implantation and revision were subdivided and the respective reasons were identified. KW - Reoperation KW - Knieprothese KW - knee arthroplasty KW - Revision KW - revision surgery Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-214034 ER - TY - THES A1 - Dreßler, Simone Anneliese T1 - Analyse der postoperativen Versorgung von Patienten mit proximaler Femurfraktur in einer Rehabilitationsklinik T1 - Analysis of postsurgical treatment of patients with fracture of the proximal femur in a rehabilitation centre N2 - Osteoporotische Frakturen sind im Zusammenhang mit proximalen Femurfrakturen beim älteren Menschen von hoher klinischer und sozioökonomischer Bedeutung. Trotz des weltweiten exponentiellen Anstiegs osteoporotischer Fakturen findet vor allem in den primär versorgenden Kliniken eine Identifizierung und adäquate Behandlung von Patienten mit hohem Risiko nur unzureichend statt. Es besteht eine hohe Variabilität innerhalb der Versorgung osteoporotischer Patienten mit PFF in der Rehabilitationsklinik. Eine systematische und evidenzbasierte Osteoporose- und Frakturprävention wird nur teilweise durchgeführt. Innerhalb des Untersuchungszeitraumes von 1993-2002 wurden 795 Patienten in einem hessischen Neuro-Orthopädischen Rehabilitations- Zentrum mit durchgeführter Knochendichtemessung in die Analyse aufgenommen, wovon 156 Patienten wegen einer PFF behandelt wurden. Das Durchschnittsalter der Patienten mit PFF liegt bei 70,4 Jahre und ist um ca. zehn Jahre älter als das Kontrollkollektiv. Mehr als 90% der proximalen Femurfrakturen treten über dem 50. Lebensjahr auf. Knapp die Hälfte der Patienten mit PFF weisen Knochendichtewerte im osteopenischen Bereich auf, fast 50% der Patienten haben nach WHO-Klassifikation eine Osteoporose. Das Frakturrisiko für Patienten mit osteoporotischen Knochendichtewerten nach WHO-Klassifikation ist im Vergleich zu Patienten ohne Osteoporose um 154% erhöht ist. Das Auftreten niedriger Knochendichtewerte scheint eine stärkere Assoziation zu proximalen Femurfrakturen als zu anderen osteoporotischen Frakturtypen zu haben. Präexistente Frakturen sind bei Patienten mit PFF seltener anzutreffen als bei Patienten ohne PFF. Das Frakturrisiko ist durch das Vorliegen früherer Frakturen um die Hälfte niedriger. Radiusfrakturen treten bei Patienten mit PFF häufiger auf als Wirbelfrakturen und sind ein Indikator für potentielle proximale Femurfrakturen, da sie zu einem frühren Zeitpunkt als PFF innerhalb der Osteoporoseerkrankung auftreten. Je älter der Patient zum Zeitpunkt des Rehabilitationsaufenthalts ist, desto häufiger weist er frühere osteoporotische Frakturen auf. Frauen mit PFF geben anamnestisch fast doppelt so häufig prävalente Frakturen an. Innerhalb des Kollektivs mit proximalen Femurfrakturen ist eine hohe Koinzidenz von Sturz- und Frakturereignissen erkennbar. Das Sturzrisiko erhöht sich für Patienten mit positiver Sturzanamnese um 150%. Statistisch sind keine signifikanten Unterschiede zwischen Patienten mit und ohne PFF bezüglich der klassischen Sturzrisikofaktoren erkennbar. Es existiert kein einheitliches Risikoprofil für ältere Menschen, vielmehr handelt es sich um ein sehr inhomogenes Patientenkollektiv. Eine Feststellung des attributalen Anteils eines potentiellen Risikofaktors zum Sturzrisiko ist oft nicht möglich. Fast alle Patienten wurden operativ versorgt. Aufgrund der schnellen postoperativen Belastbarkeit und Mobilisierung werden bevorzugt endoprothetische Operationsverfahren eingesetzt. In den operativen Kliniken zeichnet sich eine gleich bleibend defiziente posttraumatische Osteoporosediagnose über den gesamten Untersuchungszeitraum ab. Innerhalb der Akutkliniken erhalten nur knapp ein Fünftel der Patienten mit PFF eine Osteoporosemedikation. Innerhalb der Rehabilitationsklinik wurden hauptsächlich physiotherapeutische Maßnahmen zur Stärkung der Muskelkraft, Stabilitäts- und Balancetraining angewandt. Unterstützend findet eine adäquate Schmerztherapie und psychologische Betreuung der Patienten statt. Es erfolgt eine solide Abklärung eines potentiellen Vorliegens einer Osteoporose. Im Vergleich zu den primär versorgenden Kliniken ist die Versorgung innerhalb des Rehabilitations- Zentrums besser. Es bestehen jedoch Mängel in der konsequenten Verabreichung einer adäquaten spezifischen medikamentösen Therapie. Fast die Hälfte der Patienten mit PFF und osteoporotischen Knochendichtewerte gehören nach DVO-Definition zur Hochrisikogruppe für weitere osteoporotische Frakturen. Allerdings findet eine nach den heutigen Erkenntnissen der DVO-Leitlinien unzureichende medikamentöse Intervention statt. Nur jeder 10. Patient mit PFF wird mit einem Bisphosphonat als spezifische medikamentöse Therapie versorgt. Eine Nachuntersuchung der Patienten des Rehabilitations- Zentrums ab 2003 nach Implementierung der DVO- Leitlinien wäre sicherlich interessant, um eine systematische Umsetzung leitliniengerechter klinischer Behandlungspfade in der Osteoporose- und Frakturprävention zu erkennen. N2 - Osteoporotic fractures of the proximal femur (PFF)of the elderly are of high clinical and socioeconomic relevance. Despite the worldwide exponential increase in the incidence of osteoporotic fractures, patients with high risk for osteporosis are often not identified during primary care resulting in an inadequate treatment. In the examined rehabilitation centre the treatment of patients with osteoporosis and PFF varies considerably. A systematic and evidence based osteoporosis- and fracture- prevention is only partly implemented. Within the examinated period from 1993 to 2002 795 patients of a hessischen neuro-orthopedic rehabilitation centre with measured bone density were included in the study. 156 of these patients were treated due to fractures of the proximal femur (PFF). The mean age of the patients was 70.4 years being 10 years higher than in the control group. Over 90% of the patients with PFF are older than 50 years. Almost half of the patients with PFF have bone density values in the osteopenic range, the other half having osteoporosis according to the WHO classification. The risk of bone fractures for patients with osteoporotic bone density values is increased by 154% compared to patients without osteoporosis. The association of low bone density values with PFF is higher than to any other type of osteoporotic fracture. Patients with PFF show less fractures in their case history as patients without PFF. The risk for PFF is reduced by pre-existing fractures by 50%. Forearm fractures are more frequent in patients with PFF than vertebral fractures. They may be an indicator for a high risk of PFF due to their earlier incidence in osteoporosis. Women with PFF have twice as often pre-existing fractures than men with PFF. The older a patient at the time of his rehabilitation the more frequent are pre existing osteoporotic fractures. Patients with fractures of the proximal femur (PFF) show a high coincidence of fracture and trauma. The risk to fall is increased by 150% for patients with a case history of falling. No significant differences regarding classical risk factors for falling were found in patients with or without fractures of the proximal femur. The riskprofile for elderly patients was inhomogeneous. The determination of the impact of a potential risk factor on the overall risk for falling was not possible. Almost all patients were treated surgically, endoprosthetic replacement were favoured due to the possibility of early loading and mobilisation of patients. The posttraumatic osteoporosis diagnostics was insufficient in all surgical clinics. In the acute-care hospitals only 20% of patients with fracture of the proximal femur get an osteoporosis medication. Rehabilitation centres concentrated on physiotherapy, pain control and psychological support. In spite of an efficient osteoporosis diagnosis in the rehabilitation centres a specific medication was not prescribed consistently. About 50% of the patients with PFF and low BMD have a high risk for osteoporotic fractures according to the DVO guidelines. The pharmacological intervention seems to be insufficient for these patients, as only 10% are treated with bisphosphonates. An examination of the rehabilitation centre after the publication of the DVO guidelines could show if an implementation into the clinical treatment was possible and effective in prevention of osteoporosis and fractures. KW - Oberschenkelbruch KW - Rehabilitationseinrichtung KW - hip fracture KW - rehabilitation centre Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-32850 ER - TY - THES A1 - De Graaf [verh. Weinke], Karlijn T1 - Analyse des postoperativen Offsets nach Hüftprothesenwechsel T1 - Analysis of postoperative offset following revision total hip arthroplasty N2 - Die Rekonstruktion der Anatomie einer nativen Hüfte sowie deren natürlichen Biomechanik ist eine essenzielle Voraussetzung für eine zufriedenstellende Funktion einer Hüftprothese. Diese Studie beschäftigte sich mit dem Zusammenhang der Veränderung des Femoralen Offsets (FO) und dem klinischen Outcome der Patienten nach Hüftprothesenwechsel. 88 Patienten, welche sich einem Hüftprothesenwechsel unterzogen, wurden untersucht. Es wurden in prä- und postoperativen Beckenübersichtsaufnahmen das Femorale Offset, sowie weitere statische Parameter gemessen und verglichen. Die Ergebnisse wurden mit dem klinischen Outcome korreliert. Dies erfolgte anhand des Harris Hip Score (HHS), der Visuellen Analogskala (VAS) und des Merle d’Aubigne und Postel Score (MdAS). Bezüglich der Rekonstruktion des FO kam es zu einem zufriedenstellenden Ergebnis. In 22,6% konnte ein gleichgroßes, in 54% ein vergrößertes und in 22% ein verkleiner- tes FO gemessen werden. Das klinische Outcome ergab durchschnittlich ein gutes bis sehr gutes klnisches Ergebnis in allen erhobenen Scores (Gesamtpunktzahl: HHS 75,09; MdAS 14,36; VAS 0,71). Ein signifikant besseres Ergebnis hinsichtlich der Beweglichkeit und Funktionalität wurde bei gleichbleibendem und vergrößertem FO in allen klinischen Tests (VAS, HHS, MdAS) erzielt. Bei verkleinertem FO traten jedoch weniger Schmerzen auf. Die Rekonstruktion des FO ist nachweislich von Bedeutung für das klinische Outcome nach Hüftprothesenwechsel. Sie beeinflusst den Hebelarm der Muskulatur, was bei einem vergrößertem FO zu einer verbesserten Beweglichkeit und Funktionalität des Gelenkes führt, jedoch auch aufgrund der Dehnung des Bandapparats und der Muskulatur eine vermehrte Schmerzsymptomatik verursachen kann. Die Ergebnisse dieser Arbeit decken sich mit ähnlichen Studien, welche das FO bei primärer H-TEP- Implantation untersuchten. N2 - The reconstruction of the anatomy of a native hip, as well as its natural biomechanics, is an essential prerequisite for the adequate function of a hip prosthesis. This study examined the relationship between the change in Femoral Offset (FO) and the clinical outcomes of patients undergoing hip prosthesis replacement. A total of 88 patients who underwent hip prosthesis replacement were investigated. Pre- and postoperative pelvic radiographs were used to measure and compare the Femoral Offset, as well as other static parameters. The results were correlated with the clinical outcomes and assessed using the Harrison Hip Score (HHS), Visual Analog Scale (VAS) and the Merle d'Aubigné and Postel Score (MdAS). Regarding the reconstruction of FO, the results were satisfactory. In 22.6% of cases, the FO remained unchanged, while it increased in 54% of cases and decreased in 22% of cases. The clinical outcomes, on average, indicated good to very good clinical results in all the scores obtained (Total score: HHS 75.09; MdAS 14.36; VAS 0.71). A significantly better outcome in terms of mobility and functionality was achieved with either an unchanged or increased FO in all clinical tests (VAS, HHS, MdAS). However, a reduced FO was associated with less pain. The reconstruction of FO has been demonstrated to be of significance for the clinical outcomes following hip prosthesis replacement. It influences the lever arm of the abductor muscles, leading to improved joint mobility and functionality with an increased FO, while it can also result in increased pain symptoms due to excessive abductor muscle tension. The findings of this study align with similar studies that examined FO in primary THA implantation. KW - Postoperatives Offset KW - Offset Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-329104 ER - TY - THES A1 - Staab, Holger Hans T1 - Analyse polymorpher Sequenzbereiche des Promotors des Humanen Cystein-Reichen Proteins 61 (hCYR61/CCN1) T1 - Analysis of polymorphic sequence motifs in the promotor of the human cystein rich protein 61 (hCYR61/CCN1) N2 - Analyse polymorpher Sequenzbereiche des Promotors des Humanen Cystein-Reichen Proteins 61 (hCYR61/CCN1) Ziel ist es den Promotor des Wachstumsfaktor und 1,25-Dihydroxy Vitamin D3 regulierten immediate early Genproduktes von Osteoblasten und Signalmolekül im Mikroenvironment des Knochens, hCYR61/CCN1, funktionell zu charakterisieren. Zum ersten sollten 4 unterschiedliche hCYR61/CCN1 Promotorkonstrukte, mit den Längen von 200bp-1000bp auf ihre Promotoraktivität getestet werden, um so eine Vorstellung der Regulationsmechanismen des hCYR61/CCN1 Promotors zu gewinnen. Die andere Fragestellung befasste sich mit der Relevanz eines CA-Repeat Polymorphismus innerhalb des hCYR61/CCN1 Promotors, der anhand einer Gesundenpopulation nachgewiesen worden war. Das Interesse war hierbei, ob unterschiedliche CA-Repeat Längen in einem hCYR61/CCN1 Promotorkonstrukt von 450bp Länge auch unterschiedliche Promotoraktivitäten erzeugen. Die hCYR61/CCN1 Promotorkonstrukte der Länge 200bp-1000bp wurden mittels PCR eines Templates (J23219 aus einer Lambda Phagendatenbank) hergestellt. Die Länge und die Sequenz der Promotorkonstrukte überprüften wir durch Sequenzierung und Fragmentanalysen. Ausgewählte hCYR61/CCN1 Promotorkonstrukte wurden daraufhin in ein Luziferase-Vektor-System kloniert. Die entstandenen hCYR61/CCN1 Promotor-Vektorkonstrukte wurden in zwei Zellsyteme, h-fob Zellen (humane Osteoblaten) und T/C28a2 Zellen (humane Chondrozyten) durch Elektroporation transfiziert. Die Zellen wurden über 48h kultiviert, geerntet und die Promotoraktivität in einem Luminometer in Fluoreszenz Units (FU) gemessen. Es wurden zwei verschiedene Kultivierungsbedingungen der beiden Zelllinien geprüft, nämlich eine serumfreie und eine serumhaltige, um einen in der Literatur beschriebenen Seruminduktionseffekt nachweisen und überprüfen zu können. Insgesamt wurden für die hCYR61/CCN1 Promotorkonstrukte der Länge 200bp-1000bp Experimente in h-fob Zellen und T/C28a2 Zellen, jeweils unter serumfreien und serumhaltigen Bedingungen durchgeführt. Für die 450bp langen hCYR61/CCN1 Promotorkonstrukte mit den variierenden CA-Repeats von 17-22 CA-Repeats, wurden ebenso Transfektionsexperimente in beiden Zelllinien und unter beiden Kultivierungsbedingungen durchgeführt. Als Ergebnisse ist zusammengefasst festzuhalten, dass ein statistisch signifikanter Zusammenhang zwischen den hCYR61/CCN1 Promotorkonstrukten unterschiedlicher Länge von 200bp-1000bp und ihrem Promotoraktivitätsniveau besteht. Die hCYR61/CCN1 Promotorkonstrukte der Länge 200bp-800bp besitzen eine sehr hohe basale Promotoraktivität, die um den Faktor 4-5 bei serumfreier Kultivierung über der Hintergrundsaktivität liegt. Die Aktivität des 1000bp Promotorfragmentes ist signifikant niedriger (p=0,024 in h-fob Zellen und p=0,037 für T/C28a2 Zellen bei serumhaltiger wie serumfreier Kultivierung), als die der übrigen Promotorfragmente, die sich untereinander nicht signifikant in ihren Aktivitäten unterscheiden (p=0,57 in h-fob Zellen und p=0,66 für T/C28a2 Zellen bei serumfreire Kultivierung). Es besteht weiterhin ein signifikanter Seruminduktionseffekt, der für alle Konstrukte und beide Zelllinien nachzuweisen ist. Dieser ist bei den hCYR61/CCN1 Promotorkonstrukten der Länge 200bp-1000bp, ebenso wie bei den hCYR61/CCN1 Promotorkonstrukte 450bp mit den variablen 17-22 CA-Repeats nachweisbar (p=0,001 in h-fob Zellen und p=0,002 für T/C28a2 Zellen). Der Seruminduktionseffekt ist für alle Konstrukte proportional und wirkt signifikant stärker auf die T/C28a2 Zellen, als auf die h-fob Zellen. So liegt die durchschnittliche Steigerung der hCYR61/CCN1 Promotoraktivität etwa bei dem Faktor 1,5-3 in h-fob Zellen, in T/C28a2 Zellen jedoch um den Faktor 8-11. Dieser Effekt wirkt auf den Promotor von hCYR61/CCN1, da die basale Hintergrundsaktivität gemessen anhand der Transfektion des leeren Expressionsvektors pgl3-Baisc, davon unbeeinflusst bleibt. Es besteht kein statistisch signifikanter Zusammenhang zwischen den CA-Repeat Polymorphismen 17-22 CA-Repeats in dem hCYR61/CCN1 Promotorkonstrukt der Länge 450bp und deren Promotoraktivitäten (p=0,495 in h-fob Zellen und p=0,514 für T/C28a2 Zellen bei serumfreier Kultivierung und p=0,397 in h-fob Zellen und p=0,488 für T/C28a2 Zellen bei serumhaltiger Kultivierung). Die Konstrukte haben also unabhängig von der Zahl der CA-Repeats keine unterschiedliche Promotoraktivität gemessen im Luziferase Assay. Somit lässt sich in diesem in vitro System kein relevanter Effekt hinsichtlich der funktionellen Relevanz diese CA-Repeat Polymorphismus nachweisen. Weitere Experimente werden Auskunft über kausale Regulationsmechanismen des hCYR61/CCN1 Promotors und die Relevanz von hCYR61/CCN1 innerhalb des Knochenstoffwechsels geben. N2 - Analysis of polymorphic sequence motifs in the promotor of the human cystein rich protein 61 (hCYR61/CCN1) Keywords: hCYR61/CCN1 promotor · functional characterization of promotor CA-repeat polymorphism activity · Serum inducibility of hCYR61/CCN1 promotor activity · gene regulation Aims: Functional characterization of the promotor of the 1,25-Dihydroxy Vitamin D3 and growth factor regulated immediate early gene product of Osteoblasts and signaling molecule in the microenvironment of the bone hCYR61/CCN1. First, characterization of selected promotor stretches with different length of hCYR61/CCN1 considering their level of promotor activity. The second aim was the characterization of one single CA-repeat polymorphism in the 5´ flanking region of hCYR61/CCN1 in one constant hCYR61/CCN1 promotor fragment. The Hypothesis was that different CA-repeat stretches in a constant promotor fragment cause different levels of promotor activity. Methods: Four different hCYR61/CCN1 promotor stretches from 200bp-1000bp of the 5´ flanking region of hCYR61/CCN1 were produced by PCR from a template of a Phage database. Five different hCYR61/CCN1 fragments with different length of the CA stretch (varying from17-22 CA repeats) in one constant hCYR61/CCN1 promotor fragment length of 450bp, found in a healthy population, were produced by PCR. The control of the PCR products was done by sequencing and by a PCR/fragment analysis protocol. The promotor fragments were cloned into a luciferase assay vector (pgl3-basic) by the TOPO-Blueprint Vector system and transfected into two different cell systems h-fob cells (human Osteoblasts) and T/C28a2 cells (human Chondrocytes) by the use of electroporation. At least 5 different cultivations of each cell system were performed with and without fetal calf serum because the activity of hCYR61/CCN1 was described as growth factor regulated. Measurement of the promotor activity was performed with a luciferase assay system. Results: There is a statistically significant high basic activitity of 3 from 4 promotor stretches of the length 200bp, 450bp and 800bp compared to the base rate (background activity). The biggest promotor fragment 1000bp is significantly lower in promotoractivity (p=0,024 for h-fob cells and p=0,037 for T/C28a2 cells ) compared to the 3 other promotorfragments. This is reproducible for both cell systems and the two types of cell cultivation with and witout fetal calf serum (FCS). There is a significant serum induction effect on the promotor activity of the promotor of hCYR61/CCN1. This is reproducible in both cell systems (p=0,001 for h-fob cells and p=0,002 for T/C28a2 cells). The different length of CA stretches in one constant promotor fragment (450bp) of hCYR61/CCN1 have no statistically significance onto the promotor activity (p=0,495 for h-fob cells and p=0,514 for T/C28a2 cells) Discussion: The significant downregulation of promotor activity in the biggest fragment 1000bp in comparison to the smaller promotor fragments might be caused by a motif called FREAK-1 in 860bp of the 5´ flanking region of hCYR61/CCN1. There is a significant serum induction effect onto the promotoractivity of the promotor of hCYR61/CCN1 despite there is no serum response element onto the promotor like in the murine CYR61 promotor. This fact has to be explained. Further experiments have to explain this interesting effect of downregulation. There seems to exist no relevant functional link between the length of the single CA-stretch in the promotor of hCYR61/CCN1 and the activity of the promotor in vitro. KW - hCYR61/CCN1 Promotoranalyse KW - CA-Repeat Polymorphismen KW - Seruminduktion des hCYR61/CCN1 Promotors KW - Genregulation KW - hCYR61/CCN1 promotor KW - functional characterization of promotor CA-repeat polymorphism activity KW - Serum inducibility of hCYR61/CCN1 promotor activity Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12240 ER - TY - JOUR A1 - Pereira, A. R. A1 - Trivanović, D. A1 - Herrmann, M. T1 - Approaches to mimic the complexity of the skeletal mesenchymal stem/stromal cell niche in vitro JF - European Cells and Materials N2 - Mesenchymal stem/stromal cells (MSCs) are an essential element of most modern tissue engineering and regenerative medicine approaches due to their multipotency and immunoregulatory functions. Despite the prospective value of MSCs for the clinics, the stem cells community is questioning their developmental origin, in vivo localization, identification, and regenerative potential after several years of far-reaching research in the field. Although several major progresses have been made in mimicking the complexity of the MSC niche in vitro, there is need for comprehensive studies of fundamental mechanisms triggered by microenvironmental cues before moving to regenerative medicine cell therapy applications. The present comprehensive review extensively discusses the microenvironmental cues that influence MSC phenotype and function in health and disease – including cellular, chemical and physical interactions. The most recent and relevant illustrative examples of novel bioengineering approaches to mimic biological, chemical, and mechanical microenvironmental signals present in the native MSC niche are summarized, with special emphasis on the forefront techniques to achieve bio-chemical complexity and dynamic cultures. In particular, the skeletal MSC niche and applications focusing on the bone regenerative potential of MSC are addressed. The aim of the review was to recognize the limitations of the current MSC niche in vitro models and to identify potential opportunities to fill the bridge between fundamental science and clinical application of MSCs. KW - Mesenchymal stem/stromal cells KW - skeletal progenitor cells KW - niche KW - in vitro models KW - bone KW - tissue engineering Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-268823 SN - 1473-2262 VL - 37 ER -