TY - JOUR A1 - Wagenbrenner, Mike A1 - Mayer-Wagner, Susanne A1 - Rudert, Maximilian A1 - Holzapfel, Boris Michael A1 - Weissenberger, Manuel T1 - Combinations of hydrogels and mesenchymal stromal cells (MSCs) for cartilage tissue engineering — a review of the literature JF - Gels N2 - Cartilage offers limited regenerative capacity. Cell-based approaches have emerged as a promising alternative in the treatment of cartilage defects and osteoarthritis. Due to their easy accessibility, abundancy, and chondrogenic potential mesenchymal stromal cells (MSCs) offer an attractive cell source. MSCs are often combined with natural or synthetic hydrogels providing tunable biocompatibility, biodegradability, and enhanced cell functionality. In this review, we focused on the different advantages and disadvantages of various natural, synthetic, and modified hydrogels. We examined the different combinations of MSC-subpopulations and hydrogels used for cartilage engineering in preclinical and clinical studies and reviewed the effects of added growth factors or gene transfer on chondrogenesis in MSC-laden hydrogels. The aim of this review is to add to the understanding of the disadvantages and advantages of various combinations of MSC-subpopulations, growth factors, gene transfers, and hydrogels in cartilage engineering. KW - hydrogels KW - osteoarthritis KW - cartilage defects KW - MSCs KW - cartilage regeneration KW - tissue engineering Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-250177 SN - 2310-2861 VL - 7 IS - 4 ER - TY - THES A1 - Schillinger, Judith Hanna T1 - Schmerzen und ihre Therapie in der Hüftendoprothetik. Eine retrospektive Studie zum Vergleich des minimal-invasiven direkt anterioren mit dem transglutealen Zugang nach Bauer T1 - Pain and its therapy in hip arthroplasty. A retrospective study comparing the minimally invasive direct anterior approach with the transgluteal approach according to Bauer N2 - Hintergrund: Die Entwicklung minimal-invasiver gewebeschonender Zugangswege in der Hüftendoprothetik ist im Allgemeinen mit einer schnelleren Rehabilitation, einer Verringerung der postoperativen Schmerzen und einem erhöhten Patientenkomfort verbunden. Das Ziel dieser Studie war es, einen anterioren minimal-invasiven mit einem transglutealen lateralen Zugangsweg für Hüftgelenksersatzoperationen in Bezug auf postoperatives Schmerzniveau, den Schmerzmittelgebrauch, die Länge des Krankenhausaufenthalts und die Zeit bis zum Erreichen eines definierten physiotherapeutischen Therapiezieles zu vergleichen. Methoden: In dieser retrospektiven Kohortenstudie untersuchten wir 200 Patienten, die sich einer Hüftendoprothesenimplantation unterzogen. Gruppe I (n = 100) erhielt einen minimal-invasiven anterioren Hüftzugang (modifiziert nach Smith-Peterson), Gruppe II (n = 100) erhielt einen lateralen transglutealen Zugang (nach Bauer). Die Untersuchungsziele waren der Schmerz in Ruhe und während der Physiotherapie, der Schmerzmittelgebrauch, die Länge des stationären Aufenthaltes sowie die Zeitdauer bis zum Erreichen des physiotherapeutischen Therapiezieles. Ergebnisse: Die Patienten der Gruppe I konsumierten weniger Schmerzmedikamente (19,6 ± 6,9 mg Piritramid gegenüber 23,6 ± 11,3 mg; p = 0,005) und hatten in der frühen postoperativen Phase weniger Schmerzen (Operationstag: VAS 1,3 ± 1 gegenüber 2,3 ± 1,3, p = 0,0001, erster postoperativer Tag: VAS 0,41 ± 0,8 vs. 0,66 ± 1,1, p = 0,036). Die Zeit bis zum Erreichen des definierten Therapiezieles (6,4 ± 2 Tage gegenüber 7,4 ± 2,1 Tagen; p = 0,001) und die Dauer des Krankenhausaufenthalts waren kürzer (10,2 ± 1,9 Tage gegenüber 13,4 ± 1,6 Tagen; p = 0,0001) für Gruppe I. Die Schmerzen während der Physiotherapie waren jedoch am dritten und sechsten bis neunten Tag nach der Operation im Vergleich zu Gruppe II höher (p = 0,001–0,013). Schlussfolgerung: Die Implantation einer Hüftprothese über einen minimal-invasiven anterioren Zugang führt in der direkt postoperativen Phase zu einer Reduktion des Schmerzniveaus und des Schmerzmittelgebrauchs. Zusätzlich werden das Erreichen des physiotherapeutischen Therapiezieles und die Länge des stationären Aufenthaltes positiv beeinflusst. Den höheren Schmerzen während der Physiotherapie könnte durch eine Reduktion der erlaubten Gewichtsbelastung in der frühen postoperativen Phase entgegengewirkt werden. N2 - Purpose: The development of minimal-incision techniques for total hip replacement with preservation of soft tissue is generally associated with faster rehabilitation, reduction of postoperative pain and increased patient comfort. The aim of this study was to compare a minimal-incision anterior approach with a transgluteal lateral technique for hip replacement surgery with respect to postoperative pain, consumption of rescue medication, length of hospital stay and time to reach a defined range of motion. Methods: In this retrospective cohort study we investigated 100 patients with a minimal-incision anterior approach (group I) and 100 patients with a transgluteal lateral approach (group II) retrospectively undergoing unilateral hip replacement. The study variables were pain at rest and during physiotherapy, amount of rescue medication, the time to reach a defined flexion and time in hospital. Results: The patients of group I consumed less rescue medication (19.6 ± 6.9 mg vs. 23.6 ± 11.3 mg;  p = 0.005) and experienced less pain on the day of surgery (1.3 ± 1 vs. 2.3 ± 1.3, p = 0.0001) and the first postoperative day (0.41 ± 0.8 vs. 0.66 ± 1.1, p = 0.036). The time to reach the defined range of motion (6.4 ± 2 days vs. 7.4 ± 2.1 days; p = 0.001) and the length of hospital stay were shorter (10.2 ± 1.9 days vs. 13.4 ± 1.6 days; p = 0.0001) for group I. However, pain during physiotherapy was higher on the third and sixth through ninth days after surgery in comparison to group II (p = 0.001–0.013). Conclusion: The implantation of a hip prosthesis through a minimal-incision anterior approach is successful in reducing postoperative pain and consumption of pain medication. Time to recovery and length of hospital stay are also influenced positively. Pain increases during physiotherapy, and may be mitigated by adopting limited weight bearing during the early postoperative period. KW - minimal-invasiv KW - vorderer Zugang KW - Hüftendoprothetik KW - Postoperativer Schmerz KW - minimally invasiv KW - THA KW - anterior approach KW - total hip arthroplasty KW - postoperative pain KW - minimalinvasive KW - hip KW - arthroplasty Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-225745 ER - TY - THES A1 - Hacker, Dorothee T1 - Prospektiv randomisierte Untersuchungen zum klinischen Outcome nach Knierevisionen mit den Endoprothesen „EnduRo“ im Vergleich zur Prothese „Endo-Modell“ T1 - Clinical Outcome of two rotating hinge prostheses designs in revision total knee arthroplasty – a prospective randomized study N2 - Aufgrund des demographischen Wandels mit einer zunehmend älter werdenden Bevölkerung ist die Zahl der Knieprothesen und vor allem auch der Revisionsoperationen in den letzten Jahren deutlich gestiegen. Mit ebenfalls zunehmendem medizinischem Anspruch wurden die bestehenden Prothesenmodelle stetig weiter entwickelt. Ziel der vorliegenden Studie war es, in einer prospektiv angelegten einfach verblindeten Studie zwei verschiedene Rotating-Hinge-Revisionsprothesen unterschiedlicher Hersteller miteinander zu vergleichen und sie auf ihr klinisches Outcome zu überprüfen. Von Juni 2012 bis Mai 2013 wurden insgesamt 25 Patienten in die Studie aufgenommen und dann bis zu 12 Monate nach erfolgter Revisionsoperation nachuntersucht. Die Zuteilung der Prothesenarten erfolgte randomisiert, sodass 13 Patienten die Prothese „EnduRo“ und 12 Patienten die Prothese „Endo-Modell“ erhielten. Als Vergleichswerte wurden klinische Scores herangezogen. In der Untersuchung zeigten beiden Vergleichsgruppen insgesamt eine deutliche Schmerzreduktion sowie eine Funktionsverbesserungen in allen erhobenen Scores. Zwar erreichten die Patienten der Gruppe „Endo-Modell“ etwas höhere Punktwerte, jedoch waren die Unterschiede im Vergleich zur Patientengruppe „EnduRo“ im durchgeführten Zweistichproben-T-Test nicht statistisch signifikant. N2 - The number of revision surgerys of the knee is increasing due to demographic change and higher life expectancy. Therefore the development and constant improvement of prosthesis design is essential. Aim of this study was to compare the clinical outcome of two rotating hinge prostheses (EnduRo and Endo-Model). Twentyfive patients with the indication for a total knee arthroplasty replacement because of ligament instability were prospectively randomised to either the Link Endo-Model (n = 12) or the EnduRo (n = 13). Clinical Scores (American Knee Society Score, Oxford Knee Score, Visual Analog Scale and SF-36) were evaluated pre-operatively and up to twelve months postoperatively. Although both prostheses models showed significant improvements as well in function scores as in pain reduction there was a slight advantage in favor of the Endo-Model. KW - Kniegelenk KW - Kniegelenkprothese KW - Vergleichsstudie KW - Total knee arthroplasty KW - Link Endo-Model KW - EnduRo KW - Knievrevision Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-215658 ER - TY - THES A1 - Streck, Laura Elisa T1 - Zweizeitige Implantation reverser Schulterendoprothesen bei Infektionen des Glenohumeralgelenks - Diagnostik und Ergebnisse - T1 - Staged reverse shoulder arthroplasty for the management of glenohumeral joint infections N2 - Infektionen des Schultergelenks gehen mit hoher Mortalität und Morbidität einher. Ihre Diagnostik und Therapie stellen häufig eine Herausforderung dar. Zudem ist - im Gegensatz zu Infektionen von Hüfte und Knie - die schulterspezifische Datenlage spärlich, es mangelt an evidenzbasierten Diagnose- und Therapiealgorithmen. Diese Arbeit evaluiert unter anderem 1) den Erfolg der mehrzeitigen Implantation reverser Schulterendoprothesen zur Therapie von Infektionen des Glenohumeralelenks, 2) das schulterspezifische Keimspektrum, 3) den Stellenwert einer präoperativen Gelenkpunktion und 3) den Stellenwert einer Gelenkspunktion bei einliegendem Spacer. Es handelt sich um eine retrospektive Studie mit prospektiver Datenerfassung an insgesamt 41 Patienten, welche zwischen 2007-2015 in der Orthopädischen Klinik König-Ludwig-Haus (Würzburg) die mehrzeitige Implantation einer Schulterendoprothese mit zwischenzeitlicher Implantation eines PMMA-Spacers auf Grund einer Infektion des Glenohumeralgelenks erhalten haben. Die vorliegende Arbeit konnte zeigen, dass Infektionen des Glenohumeralgelenks gehäuft multimorbide, voroperierte Patienten betreffen. Die Haupterreger waren Cutibakterien und koagulasenegative Staphylokokken, insbesondere S. epidermidis. Diese Erreger sollten bei einer kalkulierten Antibiotikatherapie immer berücksichtigt werden. Mikrobiologische Kulturen der präoperative Gelenkpunktion zeigten eine mäßige Sensitivität (58%) bei guter Spezifität (89%). Die Punktion kann somit keinen sicheren Infektionsausschluss bieten, ermöglicht im Falle eines Keimnachweises jedoch die gezielte antibiotische Therapie sowie die Anpassung der Antibiotika im Spacer und hat somit einen berechtigten Stellenwert in der Infektionsdiagnostik. Die Punktion bei einliegendem Spacer zeigte eine Sensitivität von 0%, ihre routinemäßige Durchführung sollte daher sehr kritisch hinterfragt werden. Für die Therapie mit mehrzeitiger Implantation einer reversen Schulterendoprothese zeigte sich eine Infektionseradikationsrate von 87% und ein kumulatives infektionsfreies Überleben von 91% nach 128 Monaten. Die Funktionalität der Schulter blieb hinter der Funktion der Gegenseite zurück, war jedoch ausreichend um die eigenständige Versorgung und die Durchführung von Alltagsaktivitäten zu ermöglichen. Die große Mehrzahl der Patienten hatte keine/minimale Schmerzen. N2 - Shoulder joint infections (SJI) come along with a high morbidity and mortality. Diagnosis and treatment of SJI can be challenging. In contrast to infections of the hip and knee, shoulder specific data is rare and no shoulder specific evidence based algorithms for diagnosis and treatment are available. This study investigated 1) the outcome of treatment with staged implantation of a reverse shoulder arthroplasty (RSA), 2) the shoulder specific bacterial spectrum, 3) the validity of a preoperative joint aspiration (PA) and 4) the validity of a joint aspiration while a spacer is implanted (interstage aspiration, IA). This work was a retrospective study with prospective data capturing on a total of 41 patients who were treated with staged implantation of a total shoulder arthroplasty with temporary implantation of a PMMA-Spacer for the management of glenohumeral joint infection between 2007-2015 at the Orthopedic department of the University of Wuerzburg (Koenig-Ludwig-Haus). This study showed that SJI mainly appear in multimorbid patients with several preliminary surgeries. Cutibacteria and coagulase negative staphylococci, especially S. epidermidis, were the predominant pathogens. Calculated antibiotic therapy should therefore always cover these pathogens. Microbiological cultures form PA showed a moderate sensitivity (58%) and a good specificity (89%). A negative culture cannot definitely rule out infection but in case of detection of bacteria, systemic antibiotic therapy as well as the antibiotics in the spacer can be adjusted specifically. PA therefore plays an important role in the diagnosis of SJI. IA showed a sensitivity of 0%. For this reason, IA as a part of the routine diagnostic procedure should be discussed very critically. Infection eradication after staged implantation of RSA was 87%, the cumulative infection-free survival rate was 91% after 128 months. Shoulder function was limited in most cases but yet sufficient to cope with activities of daily life properly. The vast majority of patients had no/minimal pain. KW - Endoprothese KW - Gelenkinfektion KW - Schultergelenk KW - Diagnostik KW - Therapieerfolg KW - Reverse Schulterendoprothese KW - Schultergelenksinfektion Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-222626 ER - TY - THES A1 - Huber, Simon T1 - Klinisch-radiologische Evaluation des Merete® BioBall™-Adapter-Systems in der Hüftendoprothetik T1 - Outcome of a modular head-neck adapter system in hip arthroplasty N2 - Die Revisionsendoprothetik des Hüftgelenkes ist eine große Herausforderung, insbesondere bei Teilwechseln von Komponenten bei fest-implantiertem Schaft. In einer retrospektiven Analyse wurde eine Implantat-Komponente des Medizinprodukteherstellers Merete Medical (Berlin) untersucht. Ziel der Untersuchung war es, eine Aussage über die Stabilität des Implantats und den klinischen Versorgungserfolg bei dessen Verwendung treffen zu können. Es wurden Daten von insgesamt 72 Patienten erhoben. Es erfolgte eine klinische und radiologische Nachuntersuchung. Die Daten wurden einer deskriptiven und explorativen Analyse unterzogen, eine Überlebenszeitanalyse wurde durchgeführt. Das Implantat zeigte mechanische Stabilität in einem mittelfristigen Zeitraum. Der Versorgungserfolg (gemessen am Harris Hip Score) war durchschnittlich bis gut. Es zeigten sich Zusammenhänge zwischen dem präoperativen Zustand der Patienten und dem Versorgungerfolg. N2 - Revision hip arthroplasty remains a challenging task, especially when it comes to a partial exchange of components with a well-fixed stem. A retrospective analysis was performed to investigate an implant component of Merete Medical (Berlin). The aim of the study was to determine the mechanical stability and quality of care by use of the implant. Data of 72 patients were collected by conducting clinical and radiological follow-up examinations. The collected data were used for an extensive analysis. The implant showed mechanical stability during a middle-term period. The quality of care was good to average (measured by Harris Hip Score). A relation between the preoperative condition and the quality of care was found. KW - Endoprothetik KW - Hüfte KW - Revision KW - modular KW - Merete KW - Revision KW - Hip Arthroplasty KW - Implant Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-228643 ER - TY - JOUR A1 - Weissenberger, M. A1 - Weissenberger, M. H. A1 - Gilbert, F. A1 - Groll, J. A1 - Evans, C. H. A1 - Steinert, A. F. T1 - Reduced hypertrophy in vitro after chondrogenic differentiation of adult human mesenchymal stem cells following adenoviral SOX9 gene delivery JF - BMC Musculoskeletal Disorders N2 - Background Mesenchymal stem cell (MSC) based-treatments of cartilage injury are promising but impaired by high levels of hypertrophy after chondrogenic induction with several bone morphogenetic protein superfamily members (BMPs). As an alternative, this study investigates the chondrogenic induction of MSCs via adenoviral gene-delivery of the transcription factor SOX9 alone or in combination with other inducers, and comparatively explores the levels of hypertrophy and end stage differentiation in a pellet culture system in vitro. Methods First generation adenoviral vectors encoding SOX9, TGFB1 or IGF1 were used alone or in combination to transduce human bone marrow-derived MSCs at 5 x 10\(^2\) infectious particles/cell. Thereafter cells were placed in aggregates and maintained for three weeks in chondrogenic medium. Transgene expression was determined at the protein level (ELISA/Western blot), and aggregates were analysed histologically, immunohistochemically, biochemically and by RT-PCR for chondrogenesis and hypertrophy. Results SOX9 cDNA was superior to that encoding TGFB1, the typical gold standard, as an inducer of chondrogenesis in primary MSCs as evidenced by improved lacuna formation, proteoglycan and collagen type II staining, increased levels of GAG synthesis, and expression of mRNAs associated with chondrogenesis. Moreover, SOX9 modified aggregates showed a markedly lower tendency to progress towards hypertrophy, as judged by expression of the hypertrophy markers alkaline phosphatase, and collagen type X at the mRNA and protein levels. Conclusion Adenoviral SOX9 gene transfer induces chondrogenic differentiation of human primary MSCs in pellet culture more effectively than TGFB1 gene transfer with lower levels of chondrocyte hypertrophy after 3 weeks of in vitro culture. Such technology might enable the formation of more stable hyaline cartilage repair tissues in vivo. KW - Mesenchymal stem cell KW - Cartilage KW - SOX9 KW - Gene therapy KW - Chondrogenesis KW - Hypertrophy KW - Adenovirus KW - Bone marrow Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229232 VL - 20 ER - TY - THES A1 - Kramer, Lisa Sophie T1 - Charakterisierung des Einflusses von Estrogenrezeptoren auf mechanoresponsive Reporter T1 - Characterization of the influence of estrogen receptors according to mechanoresponsive reporter N2 - Osteoporose wird definiert als erworbene, generalisierte Skeletterkrankung, die durch eine verminderte Knochenfestigkeit und einen pathologischen Knochenverlust charakterisiert wird. Durch die Störung der Mikroarchitektur kommt es zu strukturellen und funktionellen Defiziten im Sinne von Fragilitätsfrakturen. Mechanische Stimulation erhält die Gewebemasse und stimuliert deren kontinuierliche Anpassung. Östrogene spielen bei der Entwicklung, dem Wachstum und der Regeneration des Knochens eine bedeutende Rolle und wirken über Bindung an die Östrogenrezeptoren ER und ER in bestimmten Zielgeweben. Östrogenrezeptoren sind unverändert sehr geeignete Targets für die Entwicklung von Medikamenten im Rahmen der Osteoporosetherapie wie z.B. die selektiven Östrogen-Rezeptor-Modulatoren (SERMs). Die molekulare Klärung der Einflüsse von ER und ER ist unverändert von großer klinischer Bedeutung. Die Herstellung stabiler Zelllinien mit Überexpression von Reportergenkonstrukten und Rezeptoren kann dabei hilfreich sein. In dieser Arbeit wurde eine stabile Zelllinie mit Überexpression von ERβ etabliert, die unterschiedliche Wirkung von ER und ER wurden analysiert und die Effekte von zyklischer Dehnung auf Reportergenexpression unter der Kontrolle von mechanosensitiven responsiven Elementen wurden charakterisiert. N2 - Osteoporosis is defined as an acquired, generalized skeletal disorder which is characterized by reduced bone stability and pathological bone loss. A disorder of the microarchitecture leads to structural and functional deficiencies in the form of fragility fractures. Mechanical strain sustains tissue and stimulates its continuous adaptation. Estrogen plays an important role in the development, growth and regeneration of bones and works by binding to the estrogen receptors ERα und ERβ in certain target tissues. Estrogen receptors continue to be significant targets in the development of pharmaceuticals for osteoporosis therapy as for example selective estrogen receptor modulators (SERMs). The clarification of the influence of ERα and ERβ on a molecular level continue to be of great clinical significance. The creation of stable cell lines with overexpression of reporter gene constructs and receptors can be helpful in this. In this thesis a stable cell line with overexpression of ERβ was established, different effects of ERα und ERβ were analyzed and the effects of mechanical strain on reporter gene constructs under controlled mechanosensitive response elements were characterized. KW - Östrogene KW - Mechanorezeptor KW - Osteoporose KW - Östrogenrezeptor KW - osteoporosis KW - Mechanotransduktion KW - mechanoresponsive Elemente KW - estrogen receptor KW - mechanotransduction KW - mechanoresponsive elements Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-222709 ER - TY - THES A1 - Swalve, Enno T1 - Wirksamkeit von niedrig dosierter Tranexamsäure bei Implantation von Knie - Endo - Prothesen T1 - Efficacy of Low Dose Tranexamic Acid in Implantation of Knee - Endo - Prostheses N2 - Eine retrospektive Studie anhand von Patientenunterlagen zum Blutverlust, Transfusionshäufigkeit und postoperativen Komplikationen bei Knie-Endo-Prothesen mit systemischer Gabe von 500 mg Tranexamsäure kurz vor Eröffnung der Blutleere! 229 Patienten in der Studiengruppe, von denen 9 eine erlaubte Wiederholungsdosis erhalten hatten, wurden verglichen mit 231 Patienten, die keine Tranexamsäure erhalten hatten. 3 Patienten der Studiengruppe gegenüber 14 Patienten der Kontrollgruppe benötigten eine Bluttransfusion. In der Studiengruppe war der niedrigste postoperative Hb bei 71,2% der Patienten 10 g/dl oder höher. In der Kontrollgruppe war es nur bei 49,4% der Patienten der Fall. Durch die Gabe von Tranexamsäure konnte der durchschnittliche, berechnete Blutverlust bei Männern von etwa 1850 ml auf 1450 ml und bei Frauen von etwa 1300 ml auf etwa 1000 ml gesenkt werden. Die Unterschiede waren signifikant! Im beobachteten Kollektiv konnte keine Steigerung der Rate an Thrombosen oder thrombembolischen Ereignissen festgestellt werden. Das Antifibrinolytikum Tranexamsäure ist in dieser niedrigen Dosierung effektiv und scheint sicher zu sein. N2 - A retrospective study based on patient blood loss, transfusion frequency and postoperative complications in knee endo prostheses with systemic administration of 500 mg Tranexamic Acid shortly before opening of the tourniquet! 229 patients in the study Group, 9 of them had received a permitted repeat dose, were compared to 231 patients who had not received Tranexamic Acid. 3 patients in the study group versus 14 patients in the control group needed a blood transfusion. The lowest postoperative Hb was 10 g/dl or higher in 71,2% of the patients in the study Group. Only 49,4% of the patients in the Control Group did so. The Administration of Tranexamic Acid reduced the average of calculated blood loss from about 1850 ml to 1450 ml in male und from about 1300 ml to about 1000 ml in female. The differences were significant No increase in the rate of thrombosis or thrombembolic Events could be observed in the collective. The antifibronolytic Tranexamic Acid is effective at this low dosage and seems to be safe. KW - Knieprothese KW - Tranexamsäure KW - Niedrig dosierte Tranexamsäure KW - Knie Endo Prothese KW - Low Dose Tranexamic acid KW - Knee Endo Prostheses Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-217446 ER - TY - THES A1 - Hann von Weyhern, Andreas T1 - Ergebnisse der Schulterendoprothetik T1 - Results in shoulder arthroplasty N2 - An der Orthopädischen Klinik König-Ludwig-Haus wurden insgesamt 65 Patienten, bei denen im Zeitraum von Juni 1991 bis Oktober 2001 zusammen 33 Hemiprothesen und 41 Totalendoprothesen implantiert worden waren, im Durchschnitt 24,2 Monate postoperativ klinisch und radiologisch nachuntersucht. Das mittlere Lebensalter der Patienten, die wegen unterschiedlichen Indikationen und mit zwei verschiedenen Systemen (Aequalis und BIOMET) versorgt worden waren, lag zum Zeitpunkt der Operation bei 64,6 Jahren. Die Ergebnisse wurden anhand des Constant Scores erhoben (maximal 100 Punkte möglich). Subjektiv waren 45% (33 Fälle) der Patienten mit dem Ergebnis sehr zufrieden und 49% (36 Fälle) zufrieden, wohingegen nur 3% (2 Fälle) unzufrieden waren. Der Constant Score lag präoperativ durchschnittlich bei 22,9 Punkten und konnte postoperativ auf 53,8 Punkte erhöht werden. Innerhalb diesen Scores zeigte die Schmerzsymptomatik die deutlichste Besserung, wenngleich der aktive Bewegungsumfang und damit die Funktionalität der Schulter ebenso gesteigert werden konnte. Deutlich geringer fiel die Besserung der Kraft aus. Lockerungszeichen der Komponenten, im Sinne von Lysesäumen im Röntgen, zeigten sich vor allem beim Glenoid (39%), welche klinisch aber bedeutungslos blieben. In elf Fällen (15%) kam es zu Komplikationen unterschiedlichen Ausmaßes,die drei Mal (4%) einen Revisionseingriff nötig werden ließen. Hinsichtlich der Indikationsstellung wurden die besten Endwerte des Constant Score bei den Patienten mit primären Omarthrosen und avaskulären Nekrosen erzielt. Im Gegensatz hierzu schnitten die Fälle mit posttraumatischen Schäden und Defektarthropathien am schlechtesten ab. Hemi- und Totalendoprothesen erzielten in unseren Untersuchungen ähnliche Ergebnisse, während die Aequalis- Prothese einen geringen Vorteil gegenüber der BIOMET-Prothese zeigte. N2 - In the time between June 1991 and octobre 2001 65 patients were treatet in the "Orthopädischen Klinik König-Ludwig Haus" by shoulder replacement. In 33 cases we did an hemiarthroplasty and in 41 cases total shoulder replacement. That means that 9 patients were treated on both sides. The average time of follow up (clinical and radiological) was 24,2 months. The mean age of the patients, who were treated by different indications and with 2 different kinds of prosthesis (Aequalis, BIOMET) was 64,4 years. To evaluate the results we used the "Constant Score" (max. Score 100 Points). In 45% (36 cases) the patients themselves were very happy and in 49% (36 cases) they were happy while only 3% (2 cases) were disappointed about the results. The mean preoperative Constant Score was 22,9 Pts. and reached up to 53,8 Pts. postoperatively. The best improvement was shwon in the indicator "pain". But also mobility and aktivity could be improved while the possible strenght of the involved shoulder showed the worst results. Lysis of the components of the prosthesis was shown in x-rays in up to 39% at the glenoid as there were no clinical symtoms (patients had no problems). In 11 cases (15%) we had minor or major complications. In 3 times (4%) it was necessary to do a revision-surgery. As we compared the different indications we got the best results (Constant Score) in cases with diagnosis "primary omarthritis" and "avascular necrosis of the humeral head" while the "posttraumatic shoulders" and the "cuff-arthropathies" showed the worst results. The were no great differences between hemi- and total-shoulder replacement, while the Aequalis Prosthesis showed an advantage towards the BIOMET-prosthesis KW - Schulterendoprothetik KW - Aequalis KW - Omarthrose KW - Rheumatoide Arthritis KW - Constant Score Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-11373 ER - TY - THES A1 - Mehling, Andreas T1 - Quantitative Knochendichtemessungen an der Scapula als Basis für dreidimensionale Finite-Elemente-Modelle T1 - Quantitative bone-density measurement at the scapular bone as a base for finite element modells N2 - Finite Elemente Modelle werden derzeit als Basis von biomechanischen Analysen für Glenoidimplantate verwendet. Dafür werden üblicherweise herkömmliche CT-Daten benutzt, die jedoch nur eine grobe Annäherung an die dreidimensionalen trabekulären Strukturen der Spongiosa darstellen. Ziel der Untersuchung war eine genaue räumliche Erfassung des strukturellen Aufbaus und der Mineralisation der gelenknahen Scapula. Für die Untersuchung wurden 34 Scapulae von 17 Leichen (9 weibliche und 8 männliche) mit einem Sterbealter von 47 - 86 Jahren (Durchschnitt 76 Jahre) in einer Alkohol-Formmalin-Lösung fixiert und mit einem pQCT-Scanner (Stratec XCT 2000)untersucht. Der pQCT-Scanner erlaubt eine selektive, volumenbezogene Bestimmung der kortikalen und spongiösen Bereiche des Knochens. 35 definierte Schnittbilder pro Scapula wurden anschließend auf einem UNIX-System der Firma HERMES in digitale 3D-Modelle umgewandelt. Die Auswertung der Daten und Vermessung, sowie die Berechnung der Geometrie erfolgte mittels des Programms AVS-Express der Firma Advanced Visual Systems. Bestimmte ROIs (Regions of Interest) wurden an Punkten der Scapula definiert und anschließend vermessen. Als zentraler Fixpunkt wurde das geometrische Zentrum der Glenoidfläche verwendet. Es konnte gezeigt werden, dass die übliche Reduktion auf kortikale und spongiöse Bereiche gleicher Dichte nur eine grobe Annäherung darstellt, die zugunsten einer komplexeren räumlichen Verteilung verlassen werden muss. Die gewonnen Daten stellen eine solide Grundlage für zukünftige Finite-Element-Analysen unter Einbeziehung der komplexen trabekulären Strukturen innerhalb der Scapula dar. N2 - Finite element modells are used as a base for biomechanical analyses for glenoidimplants. Most commonly though the database used is from computertomographic measurements, which are only an approximation of the trabecular threedimensional structures of the cancellous bone. This study was done for an exact measurement of space of the structural building and the mineralisation in the joint area of the scapula. 34 Scapulae, taken from 17 corpses (9 female 8 male) with dying age from 47 - 86 years, fixated in alcohol-formalin-solution, were examinated by pQCT scanning (Stratec XCT 2000). A pQCT scan allows selective volume-based determination of cortical and cancellous bone. 35 scans per scapula were taken and were digitized on an unix system by HERMES. Analyses of the data and measurement was done with AVS-Express by Advanced Visual Systems. Certain ROIs (regions of interest) were set at definated spots within the scapula and were measured. The central fiaxtion point was the geometrical center of the glenoid. We could show, that the usual distinction in cortical and cancellous bone of homogenic density is only an approximation, which should be left for a more complex structure. The achieved data is a base for further finite element analyses regarding the more complex trabecular strutures found in the scapula. KW - Schulter KW - Finite Elemente KW - Knochendichte KW - shoulder KW - finite element KW - bone density Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-11054 ER -