TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans‑Christer A1 - Kunz, Philipp A1 - Leppich, Robert A1 - Sperlich, Billy T1 - Intra-individual physiological response of recreational runners to different training mesocycles: a randomized cross-over study JF - European Journal of Applied Physiology N2 - Purpose Pronounced differences in individual physiological adaptation may occur following various training mesocycles in runners. Here we aimed to assess the individual changes in performance and physiological adaptation of recreational runners performing mesocycles with different intensity, duration and frequency. Methods Employing a randomized cross-over design, the intra-individual physiological responses [i.e., peak (\(\dot{VO}_{2peak}\)) and submaximal (\(\dot{VO}_{2submax}\)) oxygen uptake, velocity at lactate thresholds (V\(_2\), V\(_4\))] and performance (time-to-exhaustion (TTE)) of 13 recreational runners who performed three 3-week sessions of high-intensity interval training (HIIT), high-volume low-intensity training (HVLIT) or more but shorter sessions of HVLIT (high-frequency training; HFT) were assessed. Results \(\dot{VO}_{2submax}\), V\(_2\), V\(_4\) and TTE were not altered by HIIT, HVLIT or HFT (p > 0.05). \(\dot{VO}_{2peak}\) improved to the same extent following HVLIT (p = 0.045) and HFT (p = 0.02). The number of moderately negative responders was higher following HIIT (15.4%); and HFT (15.4%) than HVLIT (7.6%). The number of very positive responders was higher following HVLIT (38.5%) than HFT (23%) or HIIT (7.7%). 46% of the runners responded positively to two mesocycles, while 23% did not respond to any. Conclusion On a group level, none of the interventions altered \(\dot{VO}_{2submax}\), V\(_2\), V\(_4\) or TTE, while HVLIT and HFT improved \(\dot{VO}_{2peak}\). The mean adaptation index indicated similar numbers of positive, negative and non-responders to HIIT, HVLIT and HFT, but more very positive responders to HVLIT than HFT or HIIT. 46% responded positively to two mesocycles, while 23% did not respond to any. These findings indicate that the magnitude of responses to HIIT, HVLIT and HFT is highly individual and no pattern was apparent. KW - cardiorespiratory fitness KW - endurance KW - personalized training Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-235022 SN - 1439-6319 VL - 120 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Instant Biofeedback Provided by Wearable Sensor Technology Can Help to Optimize Exercise and Prevent Injury and Overuse JF - Frontiers in Physiology KW - sports KW - training optimization KW - performance monitoring KW - health monitoring KW - technology KW - coaching Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158044 VL - 8 IS - 167 ER - TY - JOUR A1 - Düking, Peter A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - The potential usefulness of virtual reality systems for athletes: a short SWOT analysis JF - Frontiers in Physiology N2 - No abstract available. KW - SWOT KW - virtual reality KW - athletes Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176178 VL - 9 IS - 128 ER - TY - JOUR A1 - Düking, Peter A1 - Giessing, Laura A1 - Frenkel, Marie Ottilie A1 - Koehler, Karsten A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study JF - JMIR mhealth and uhealth N2 - Background: Physical activity reduces the incidences of noncommunicable diseases, obesity, and mortality, but an inactive lifestyle is becoming increasingly common. Innovative approaches to monitor and promote physical activity are warranted. While individual monitoring of physical activity aids in the design of effective interventions to enhance physical activity, a basic prerequisite is that the monitoring devices exhibit high validity. Objective: Our goal was to assess the validity of monitoring heart rate (HR) and energy expenditure (EE) while sitting or performing light-to-vigorous physical activity with 4 popular wrist-worn wearables (Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa). Methods: While wearing the 4 different wearables, 25 individuals performed 5 minutes each of sitting, walking, and running at different velocities (ie, 1.1 m/s, 1.9 m/s, 2.7 m/s, 3.6 m/s, and 4.1 m/s), as well as intermittent sprints. HR and EE were compared to common criterion measures: Polar-H7 chest belt for HR and indirect calorimetry for EE. Results: While monitoring HR at different exercise intensities, the standardized typical errors of the estimates were 0.09-0.62, 0.13-0.88, 0.62-1.24, and 0.47-1.94 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 0.9%-4.3%, 2.2%-6.7%, 2.9%-9.2%, and 4.1%-19.1%, respectively, for the 4 wearables. While monitoring EE at different exercise intensities, the standardized typical errors of the estimates were 0.34-1.84, 0.32-1.33, 0.46-4.86, and 0.41-1.65 for the Apple Watch Series 4, Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, respectively. Depending on exercise intensity, the corresponding coefficients of variation were 13.5%-27.1%, 16.3%-28.0%, 15.9%-34.5%, and 8.0%-32.3%, respectively. Conclusions: The Apple Watch Series 4 provides the highest validity (ie, smallest error rates) when measuring HR while sitting or performing light-to-vigorous physical activity, followed by the Polar Vantage V, Garmin Fenix 5, and Fitbit Versa, in that order. The Apple Watch Series 4 and Polar Vantage V are suitable for valid HR measurements at the intensities tested, but HR data provided by the Garmin Fenix 5 and Fitbit Versa should be interpreted with caution due to higher error rates at certain intensities. None of the 4 wrist-worn wearables should be employed to monitor EE at the intensities and durations tested." KW - cardiorespiratory fitness KW - innovation KW - smartwatch KW - technology KW - wearable KW - digital health Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229413 VL - 8 IS - 5 ER - TY - JOUR A1 - Düking, Peter A1 - Fuss, Franz Konstantin A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Recommendations for assessment of the reliability, sensitivity, and validity of data provided by wearable sensors designed for monitoring physical activity JF - JMIR Mhealth and Uhealth N2 - Although it is becoming increasingly popular to monitor parameters related to training, recovery, and health with wearable sensor technology (wearables), scientific evaluation of the reliability, sensitivity, and validity of such data is limited and, where available, has involved a wide variety of approaches. To improve the trustworthiness of data collected by wearables and facilitate comparisons, we have outlined recommendations for standardized evaluation. We discuss the wearable devices themselves, as well as experimental and statistical considerations. Adherence to these recommendations should be beneficial not only for the individual, but also for regulatory organizations and insurance companies. KW - internet of things KW - activity tracker KW - data mining KW - load management KW - physical activity KW - smartwatch Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176202 VL - 6 IS - 4 ER - TY - JOUR A1 - Düking, Peter A1 - Achtzehn, Silvia A1 - Holmberg, Hans-Christer A1 - Sperlich, Billy T1 - Integrated framework of load monitoring by a combination of smartphone applications, wearables and point-of-care testing provides feedback that allows individual responsive adjustments to activities of daily living JF - Sensors N2 - Athletes schedule their training and recovery in periods, often utilizing a pre-defined strategy. To avoid underperformance and/or compromised health, the external load during training should take into account the individual’s physiological and perceptual responses. No single variable provides an adequate basis for planning, but continuous monitoring of a combination of several indicators of internal and external load during training, recovery and off-training as well may allow individual responsive adjustments of a training program in an effective manner. From a practical perspective, including that of coaches, monitoring of potential changes in health and performance should ideally be valid, reliable and sensitive, as well as time-efficient, easily applicable, non-fatiguing and as non-invasive as possible. Accordingly, smartphone applications, wearable sensors and point-of-care testing appear to offer a suitable monitoring framework allowing responsive adjustments to exercise prescription. Here, we outline 24-h monitoring of selected parameters by these technologies that (i) allows responsive adjustments of exercise programs, (ii) enhances performance and/or (iii) reduces the risk for overuse, injury and/or illness. KW - biofeedback KW - eHealth KW - individualized training KW - injury prevention KW - IoT KW - periodization KW - load management Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-176506 VL - 18 IS - 5 ER - TY - JOUR A1 - Domokos, Bruno A1 - Beer, Lisa A1 - Reuther, Stefanie A1 - Raschka, Christoph A1 - Spang, Christoph T1 - Immediate effects of isolated lumbar extension resistance exercise (ILEX) on spine posture and mobility measured with the IDIAG Spinal Mouse System JF - Journal of Functional Morphology and Kinesiology N2 - Posture and mobility are important aspects for spinal health. In the context of low back pain, strategies to alter postural anomalies (e.g., hyper/hypolordosis, hyper/hypokyphosis) and mobility deficits (e.g., bending restrictions) have been of interest to researchers and clinicians. Machine-based isolated lumbar extension resistance exercise (ILEX) has been used successfully for rehabilitation of patients suffering from low back pain. The aim of this study was to analyse the immediate effects of ILEX on spinal posture and mobility. In this interventional cohort study, the posture and mobility measures of 33 healthy individuals (m = 17, f = 16; mean age 30.0 years) were taken using the surface-based Spinal Mouse system (IDIAG M360©, Fehraltdorf, Switzerland). Individuals performed one exercise set to full exhaustion with an ILEX-device (Powerspine, Wuerzburg, Germany) in a standardized setup, including uniform range of motion and time under tension. Scans were made immediately before and after the exercise. There was an immediate significant decrease in standing lumbar lordosis and thoracic kyphosis. No change could be observed in standing pelvic tilt. Mobility measures showed a significant decrease in the lumbar spine and an increase in the sacrum. The results show that ILEX alters spine posture and mobility in the short-term, which may benefit certain patient groups. KW - low back pain KW - spine KW - posture KW - mobility KW - exercise KW - ILEX KW - surface scanner Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-319334 SN - 2411-5142 VL - 8 IS - 2 ER - TY - JOUR A1 - Davidson, Padraig A1 - Düking, Peter A1 - Zinner, Christoph A1 - Sperlich, Billy A1 - Hotho, Andreas T1 - Smartwatch-Derived Data and Machine Learning Algorithms Estimate Classes of Ratings of Perceived Exertion in Runners: A Pilot Study JF - Sensors N2 - The rating of perceived exertion (RPE) is a subjective load marker and may assist in individualizing training prescription, particularly by adjusting running intensity. Unfortunately, RPE has shortcomings (e.g., underreporting) and cannot be monitored continuously and automatically throughout a training sessions. In this pilot study, we aimed to predict two classes of RPE (≤15 “Somewhat hard to hard” on Borg’s 6–20 scale vs. RPE >15 in runners by analyzing data recorded by a commercially-available smartwatch with machine learning algorithms. Twelve trained and untrained runners performed long-continuous runs at a constant self-selected pace to volitional exhaustion. Untrained runners reported their RPE each kilometer, whereas trained runners reported every five kilometers. The kinetics of heart rate, step cadence, and running velocity were recorded continuously ( 1 Hz ) with a commercially-available smartwatch (Polar V800). We trained different machine learning algorithms to estimate the two classes of RPE based on the time series sensor data derived from the smartwatch. Predictions were analyzed in different settings: accuracy overall and per runner type; i.e., accuracy for trained and untrained runners independently. We achieved top accuracies of 84.8 % for the whole dataset, 81.8 % for the trained runners, and 86.1 % for the untrained runners. We predict two classes of RPE with high accuracy using machine learning and smartwatch data. This approach might aid in individualizing training prescriptions. KW - artificial intelligence KW - endurance KW - exercise intensity KW - precision training KW - prediction KW - wearable Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-205686 SN - 1424-8220 VL - 20 IS - 9 ER - TY - JOUR A1 - Chtourou, Hamdi A1 - Engel, Florian Azad A1 - Fakhfakh, Hassen A1 - Fakhfakh, Hazem A1 - Hammouda, Omar A1 - Ammar, Achraf A1 - Trabelsi, Khaled A1 - Souissi, Nizar A1 - Sperlich, Billy T1 - Diurnal Variation of Short-Term Repetitive Maximal Performance and Psychological Variables in Elite Judo Athletes JF - Frontiers in Physiology N2 - Objectives: The aim of this study was to examine the effect of time of day on short-term repetitive maximal performance and psychological variables in elite judo athletes. Methods: Fourteen Tunisian elite male judokas (age: 21 ± 1 years, height:172 ± 7 cm, body-mass: 70.0 ± 8.1 kg) performed a repeated shuttle sprint and jump ability (RSSJA) test (6 m × 2 m × 12.5 m every 25-s incorporating one countermovement jump (CMJ) between sprints) in the morning (7:00 a.m.) and afternoon (5:00 p.m.). Psychological variables (Profile of mood states (POMS-f) and Hooper questionnaires) were assessed before and ratings of perceived exertion (RPE) immediately after the RSSJA. Results: Sprint times (p > 0.05) of the six repetition, fatigue index of sprints (p > 0.05) as well as mean (p > 0.05) jump height and fatigue index (p > 0.05) of CMJ did not differ between morning and afternoon. No differences were observed between the two times-of-day for anxiety, anger, confusion, depression, fatigue, interpersonal relationship, sleep, and muscle soreness (p > 0.05). Jump height in CMJ 3 and 4 (p < 0.05) and RPE (p < 0.05) and vigor (p < 0.01) scores were higher in the afternoon compared to the morning. Stress was higher in the morning compared to the afternoon (p < 0.01). Conclusion: In contrast to previous research, repeated sprint running performance and mood states of the tested elite athletes showed no-strong dependency of time-of-day of testing. A possible explanation can be the habituation of the judo athletes to work out early in the morning. KW - circadian rhythm KW - repeated sprint running KW - repeated exercise KW - mood KW - fatigue Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-189269 SN - 1664-042X VL - 9 ER - TY - JOUR A1 - Born, Dennis‐Peter A1 - Kunz, Philipp A1 - Sperlich, Billy T1 - Reliability and validity of an agility‐like incremental exercise test with multidirectional change‐of‐direction movements in response to a visual stimulus JF - Physiological Reports N2 - The aim of the study was to evaluate the reliability and validity of cardiorespiratory and metabolic variables, that is, peak oxygen uptake (V'O\(_{2peak}\)) and heart rate (HR\(_{peak}\)), obtained from an agility‐like incremental exercise test for team sport athletes. To investigate the test–retest reliability, 25 team sport athletes (age: 22 ± 3 years, body mass: 75 ± 7 kg, height: 182 ± 6 cm) performed an agility‐like incremental exercise test on the SpeedCourt (SC) system incorporating multidirectional change‐of‐direction (COD) movements twice. For each step of the incremental SC test, the athletes covered a 40‐m distance interspersed with a 10‐sec rest period. Each 40 m distance was split into short sprints (2.25–6.36 m) separated by multidirectional COD movements (0°–180°), which were performed in response to an external visual stimulus. All performance and physiological data were validated with variables obtained from a ramp‐like treadmill and Yo‐Yo intermittent recovery level 2 test (Yo‐Yo IR2). The incremental SC test revealed high test–retest reliability for the time to exhaustion (ICC = 0.85, typical error [TE] = 0.44, and CV% = 3.88), V'O\(_{2peak}\), HR\(_{peak}\), ventilation, and breathing frequency (ICC = 0.84, 0.72, 0.89, 0.77, respectively). The time to exhaustion (r = 0.50, 0.74) of the incremental SC test as well as the peak values for V'O\(_{2}\) (r = 0.59, 0.52), HR (r = 0.75, 0.78), ventilation (r = 0.57, 0.57), and breathing frequency (r = 0.68, 0.68) were significantly correlated (P ≤ 0.01) with the ramp‐like treadmill test and the Yo‐Yo IR2, respectively. The incremental SC test represents a reliable and valid method to assess peak values for V'O\(_{2}\) and HR with respect to the specific demand of team sport match play by incorporating multidirectional COD movements, decision making, and cognitive components. KW - speed KW - Yo‐Yo intermittent recovery KW - change‐of‐direction movement KW - repeated sprint ability KW - team sport Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158265 VL - 5 IS - 9 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Zinner, Christoph A1 - Sperlich, Billy T1 - The mucosal immune function is not compromised during a period of high-intensity interval training. Is it time to reconsider an old assumption? JF - Frontiers in Physiology N2 - Purpose: The aim of the study was to evaluate the mucosal immune function and circadian variation of salivary cortisol, Immunoglobin-A (sIgA) secretion rate and mood during a period of high-intensity interval training (HIIT) compared to long-slow distance training (LSD). Methods: Recreational male runners (n = 28) completed nine sessions of either HIIT or LSD within 3 weeks. The HIIT involved 4 × 4 min of running at 90–95% of maximum heart rate interspersed with 3 min of active recovery while the LSD comprised of continuous running at 70–75% of maximum heart rate for 60–80 min. The psycho-immunological stress-response was investigated with a full daily profile of salivary cortisol and immunoglobin-A (sIgA) secretion rate along with the mood state on a baseline day, the first and last day of training and at follow-up 4 days after the last day of training. Before and after the training period, each athlete's running performance and peak oxygen uptake (V·O\(_{2peak}\)) was determined with an incremental exercise test. Results: The HIIT resulted in a longer time-to-exhaustion (P = 0.02) and increased V·O\(_{2peak}\) compared to LSD (P = 0.01). The circadian variation of sIgA secretion rate showed highest values in the morning immediately after waking up followed by a decrease throughout the day in both groups (P < 0.05). With HIIT, the wake-up response of sIgA secretion rate was higher on the last day of training (P < 0.01) as well as the area under the curve (AUC\(_{G}\)) higher on the first and last day of training and follow-up compared to the LSD (P = 0.01). Also the AUC\(_{G}\) for the sIgA secretion rate correlated with the increase in V·O\(_{2peak}\) and running performance. The AUC\(_{G}\) for cortisol remained unaffected on the first and last day of training but increased on the follow-up day with both, HIIT and LSD (P < 0.01). Conclusion: The increased sIgA secretion rate with the HIIT indicates no compromised mucosal immune function compared to LSD and shows the functional adaptation of the mucosal immune system in response to the increased stress and training load of nine sessions of HIIT. KW - high-volume training KW - periodization KW - circadian rhythm KW - cortisol KW - diurnal profile KW - endurance KW - immunoglobin-A Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-158025 VL - 8 IS - 485 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Zinner, Christoph A1 - Düking, Peter A1 - Sperlich, Billy T1 - Multi-Directional Sprint Training Improves Change-Of-Direction Speed and Reactive Agility in Young Highly Trained Soccer Players JF - Journal of Sports Science and Medicine N2 - The aim of this study was to evaluate the effect of a repeated sprint training with multi-directional change-of-direction (COD) movements (RSmulti) compared to repeated shuttle sprints (RSS) on variables related to COD speed and reactive agility. Nineteen highly-trained male U15 soccer players were assigned into two groups performing either RSmulti or RSS. For both groups, each training session involved 20 repeated 15 s sprints interspersed with 30 s recovery. With RSmulti the COD movements were randomized and performed in response to a visual stimulus, while the RSS involved predefined 180° COD movements. Before and following the six training sessions, performance in the Illinois agility test (IAT), COD speed in response to a visual stimulus, 20 m linear sprint time and vertical jumping height were assessed. Both groups improved their performance in the IAT (p < 0.01, ES = 1.13; p = 0.01, ES = 0.55). The COD speed in response to a visual stimulus improved with the RSmulti (p < 0.01, ES = 1.03), but not the RSS (p = 0.46, ES = 0.28). No differences were found for 20 m sprint time (P=0.73, ES = 0.07; p = 0.14, ES = 0.28) or vertical jumping height (p = 0.46, ES = 0.11; p = 0.29, ES = 0.12) for the RSmulti and RSS, respectively. In conclusion, performance in the IAT improved with the RSmulti as well as RSS. With the RSmulti however, the COD movements are performed in response to a visual stimulus, which may result in specific adaptations that improve COD speed and reactive agility in young highly trained soccer players. KW - team sport KW - COD movements KW - repeated shuttle sprints KW - speed KW - Speedcourt Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-146866 UR - http://www.jssm.org/researchjssm-15-314.xml.xml VL - 15 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Holmberg, Hans-Christer A1 - Goernet, Florian A1 - Sperlich, Billy T1 - A novel compression garment with adhesive silicone stripes improves repeated sprint performance – a multi-experimental approach on the underlying mechanisms JF - BMC Sports Science, Medicine and Rehabilitation N2 - Background Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors. Methods In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12). Results In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered. Conclusion Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique. KW - textile KW - tissue saturation index KW - venous system KW - video analysis KW - oxygen uptake KW - blood flow KW - clothing KW - oscillation KW - oxygenation Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-120591 SN - 2052-1847 VL - 6 IS - 21 ER - TY - JOUR A1 - Born, Dennis-Peter A1 - Holmberg, Hans-Christer A1 - Goernert, Florian A1 - Sperlich, Billy T1 - A novel compression garment with adhesive silicone stripes improves repeated sprint performance – a multi-experimental approach on the underlying mechanisms JF - BMC Sports Science, Medicine and Rehabilitation N2 - Background Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors. Methods In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12). Results In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered. Conclusion Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique. KW - tissue saturation index KW - blood flow KW - clothing KW - oscillation KW - oxygenation KW - oxygen uptake KW - textile KW - venous system KW - video analysis Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-116995 UR - http://www.biomedcentral.com/2052-1847/6/21 VL - 6 IS - 21 ER - TY - JOUR A1 - Becker, Manuel A1 - Sperlich, Billy A1 - Zinner, Christoph A1 - Achtzehn, Silvia T1 - Intra-Individual and Seasonal Variation of Selected Biomarkers for Internal Load Monitoring in U-19 Soccer Players JF - Frontiers in Physiology N2 - The aim of this study was to investigate inter-day and -week as well as intra- and inter-individual variation of selected biomarkers in high-performance youth soccer players to assist practitioners interpreting player’s internal load to counteract underperformance and unwanted health risks. Eleven male youth soccer players were tested multiple times during two 3-week periods at midpoint (3-wkmid) and at the end (3-wkend) of the first half of a German under-19 1. Bundesliga season. The levels of creatine kinase (CK), urea, and C-reactive protein (CRP) were measured during 3-wkmid and 3-wkend each Monday, Wednesday, and Friday. In 3-wkmid the CK median was 14% higher (241 vs. 212 U/L) compared to 3-wkend (P = 0.26, ES = 0.16). Overall, the medians of CK, urea (P = 0.59, ES = 0.08), and CRP (P = 0.56, ES = 0.10) during 3-wkmid did not differ to the values of 3-wkend. Daily coefficient of variations (CVs) ranged from 22 to 71% (CK), 17 to 37% (urea), and 9 to 164% (CRP). Individual medians ranged from 101 to 350 U/L (CK), 23 to 50 mg/dL (urea), and 0.6 to 1.1 mg/L (CRP). High intra-individual variability was demonstrated by large intra-individual CVs (medians: CK 50%, urea 18%, and CRP 45%). Our data show (i) large inter-day and inter-week variability of all biomarkers, depending on the external load and (ii) considerable inter- and intra-individual parameter variations. Creatine kinase concentrations could sensitively reflect soccer-specific loads during the season. KW - biomarker variability KW - creatine kinase KW - soccer KW - youth soccer KW - internal load KW - monitoring KW - point of care testing Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-209616 SN - 1664-042X VL - 11 IS - 838 ER - TY - JOUR A1 - Beck, Franziska A1 - Engel, Florian A. A1 - Reimers, Anne Kerstin T1 - Compensation or displacement of physical activity in children and adolescents: a systematic review of empirical studies JF - Children N2 - Regular physical activity during childhood and adolescence is associated with health benefits. Consequently, numerous health promotion programs for children and adolescents emphasize the enhancement of physical activity. However, the ActivityStat hypothesis states that increases in physical activity in one domain are compensated for by decreasing physical activity in another domain. Currently, little is known about how physical activity varies in children and adolescents within intervals of one day or multiple days. This systematic review provides an overview of studies that analyzed changes in (overall) physical activity, which were assessed with objective measurements, or compensatory mechanisms caused by increases or decreases in physical activity in a specific domain in children and adolescents. A systematic search of electronic databases (PubMed, Scopus, Web of Science, SportDiscus) was performed with a priori defined inclusion criteria. Two independent researchers screened the literature and identified and rated the methodological quality of the studies. A total of 77 peer-reviewed articles were included that analyzed changes in overall physical activity with multiple methodological approaches resulting in compensation or displacement. Of 40,829 participants, 16,265 indicated compensation associated with physical activity. Subgroup analyses separated by study design, participants, measurement instrument, physical activity context, and intervention duration also showed mixed results toward an indication of compensation. Quality assessment of the included studies revealed that they were of high quality (mean = 0.866). This review provides inconclusive results about compensation in relation to physical activity. A trend toward increased compensation in interventional studies and in interventions of longer duration have been observed. KW - compensation KW - displacement KW - physical activity KW - children KW - adolescents Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-267231 SN - 2227-9067 VL - 9 IS - 3 ER - TY - JOUR A1 - Bauer, Nikolai A1 - Sperlich, Billy A1 - Holmberg, Hans-Christer A1 - Engel, Florian A. T1 - Effects of High-Intensity Interval Training in School on the Physical Performance and Health of Children and Adolescents: A Systematic Review with Meta-Analysis JF - Sports Medicine - Open N2 - Objectives To assess the impact of HIIT performed at school, i.e. both in connection with physical education (intra-PE) and extracurricular sports activities (extra-PE), on the physical fitness and health of children and adolescents. Methods PubMed and SPORTDiscus were searched systematically utilizing the following criteria for inclusion: (1) healthy children and adolescents (5–18 years old) of normal weight; (2) HIIT performed intra- and/or extra-PE for at least 5 days at an intensity ≥ 80% of maximal heart rate (HR\(_{max}\)) or peak oxygen uptake (VO\(_{2peak}\)) or as Functional HIIT; (3) comparison with a control (HIIT versus alternative interventions); and (4) pre- and post-analysis of parameters related to physical fitness and health. The outcomes with HIIT and the control interventions were compared utilizing Hedges’ g effect size (ES) and associated 95% confidence intervals. Results Eleven studies involving 707 participants who performed intra-PE and 388 participants extra-PE HIIT were included. In comparison with the control interventions, intra-PE HIIT improved mean ES for neuromuscular and anaerobic performance (ES jump performance: 5.89 ± 5.67 (range 1.88–9.90); ES number of push-ups: 6.22 (range n.a.); ES number of sit-ups: 2.66 ± 2.02 (range 1.24–4.09)), as well as ES fasting glucose levels (− 2.68 (range n.a.)) more effectively, with large effect sizes. Extra-PE HIIT improved mean ES for neuromuscular and anaerobic performance (ES jump performance: 1.81 (range n.a.); ES number of sit-ups: 2.60 (range n.a.)) to an even greater extent, again with large effect sizes. Neither form of HIIT was more beneficial for parameters related to cardiorespiratory fitness than the control interventions. Conclusion Compared to other forms of exercise (e.g. low-to-moderate-intensity running or walking), both intra- and extra-PE HIIT result in greater improvements in neuromuscular and anaerobic performance, as well as in fasting levels of glucose in school children. KW - adolescents KW - health-related fitness KW - physical fitness KW - children KW - high-intensity interval training KW - physical education Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-301205 SN - 2199-1170 VL - 8 IS - 1 ER - TY - JOUR A1 - Alfredson, Håkan A1 - Waldén, Markus A1 - Roberts, David A1 - Spang, Christoph T1 - Combined midportion Achilles and plantaris tendinopathy: a 1-year follow-up study after ultrasound and color-Doppler-guided WALANT surgery in a private setting in southern Sweden JF - Medicina N2 - Background and Objectives: Chronic painful midportion Achilles combined with plantaris tendinopathy can be a troublesome condition to treat. The objective was to prospectively follow patients subjected to ultrasound (US)- and color doppler (CD)-guided wide awake, local anesthetic, no-tourniquet (WALANT) surgery in a private setting. Material and Methods: Twenty-six Swedish patients (17 men and 9 women, mean age 50 years (range 29–62)) and eight international male patients (mean age of 38 years (range 25–71)) with combined midportion Achilles and plantaris tendinopathy in 45 tendons altogether were included. All patients had had >6 months of pain and had tried non-surgical treatment with eccentric training, without effect. US + CD-guided surgical scraping of the ventral Achilles tendon and plantaris removal under local anesthesia was performed on all patients. A 4–6-week rehabilitation protocol with an immediate full-weight-bearing tendon loading regime was used. The VISA-A score and a study-specific questionnaire evaluating physical activity level and subjective satisfaction with the treatment were used for evaluation. Results: At the 1-year follow-up, 32/34 patients (43 tendons) were satisfied with the treatment result and had returned to their pre-injury Achilles tendon loading activity. There were two dropouts (two tendons). For the Swedish patients, the mean VISA-A score increased from 34 (0–64) before surgery to 93 (61–100) after surgery (p < 0.001). There were two complications, one wound rupture and one superficial skin infection. Conclusions: For patients suffering from painful midportion Achilles tendinopathy and plantaris tendinopathy, US + CD-guided surgical Achilles tendon scraping and plantaris tendon removal showed a high satisfaction rate and good functional results 1 year after surgery. KW - Achilles tendinopathy KW - plantaris tendinopathy KW - surgical treatment KW - follow-up Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-303966 SN - 1648-9144 VL - 59 IS - 3 ER -