The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 2 of 19077
Back to Result List

Biomechanische Analyse eines anterioren Fixateur Interne zur Stabilisierung der vorderen Beckenringverletzung als Alternative zum Fixateur Externe an einem synthetischen Knochenmodell

Biomechanical analysis of anterior subcutaneous internal fixation of pelvic ring injuries as an alternative to external fixation on a synthetic bone model

Please always quote using this URN: urn:nbn:de:bvb:20-opus-209710
  • In dieser Studie wird die biomechanische Stabilität des anterioren subkutanen Fixateur Interne (USS II Polyaxiales- bzw. Click’X System) zur Stabilisierung der vorderen Beckenringverletzung mit der des supraacetabulären Fixateur Externe verglichen. An 36 Beckenmodellen aus Polyurethanschaum wurden instabile Beckenringverletzungen generiert. Diese wurden zunächst posterior mit je zwei sakroiliakalen Schrauben und anterior jeweils mit einem der drei genannten Fixateure versorgt und dann im Einbeinstand für je 1000 Zyklen mit 300, 400 und 500 NIn dieser Studie wird die biomechanische Stabilität des anterioren subkutanen Fixateur Interne (USS II Polyaxiales- bzw. Click’X System) zur Stabilisierung der vorderen Beckenringverletzung mit der des supraacetabulären Fixateur Externe verglichen. An 36 Beckenmodellen aus Polyurethanschaum wurden instabile Beckenringverletzungen generiert. Diese wurden zunächst posterior mit je zwei sakroiliakalen Schrauben und anterior jeweils mit einem der drei genannten Fixateure versorgt und dann im Einbeinstand für je 1000 Zyklen mit 300, 400 und 500 N be- und entlastet. Statistisch zeigt sich zwischen den drei Gruppen kein signifikanter Unterschied für die Stabilität. Mit geringeren Komplikationsraten und vergleichbarer Stabilität bietet der anteriore subkutane Fixateur Interne klinisch sowie biomechanisch eine Alternative zum Fixateur Externe. Zudem besteht die Forderung nach einem für die Beckenringfixation konzipierten subkutanen Fixations-System, das unerwünschte Bewegungsfreiheiten des Titanbügels verhindert und damit Risiken für die Patienten minimiert.show moreshow less
  • This study compares the biomechanical stability of anterior subcutaneous fixation (USS II Polyaxial- resp. Click’X system) of pelvic ring injuries to the supraacetabular external fixator. On 36 synthetic pelvic bone models an unstable pelvic ring fracture was generated. Posterior fixation was achieved by two sacroiliacal screws. Anterior fixation was performed with one of the three mentioned Fixators. They were tested for each 1000 cycles with 300, 400, and 500 N using a single-leg stance model. Statistically there was no significantThis study compares the biomechanical stability of anterior subcutaneous fixation (USS II Polyaxial- resp. Click’X system) of pelvic ring injuries to the supraacetabular external fixator. On 36 synthetic pelvic bone models an unstable pelvic ring fracture was generated. Posterior fixation was achieved by two sacroiliacal screws. Anterior fixation was performed with one of the three mentioned Fixators. They were tested for each 1000 cycles with 300, 400, and 500 N using a single-leg stance model. Statistically there was no significant difference in stabilitiy between any of the groups. With a smaller rate of complication and comparable stability the anterior subcutaneous fixator clinically and biomechanically offers an alternative to the external fixator. Further, a fixation device specifically designed for pelvic ring fixation is required to prevent undesired movement of the titanious rod and thereby minimize risks for the patients.show moreshow less

Download full text files

Export metadata

Metadaten
Author: Anna-Christina Brems
URN:urn:nbn:de:bvb:20-opus-209710
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II)
Referee:Prof. Dr. med. Rainer H. Meffert
Date of final exam:2020/07/21
Language:German
Year of Completion:2020
DOI:https://doi.org/10.25972/OPUS-20971
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 617 Chirurgie und verwandte medizinische Fachrichtungen
GND Keyword:Beckenringfraktur; Fixateur externe; Fixateur interne; Biomechanische
Tag:Beckenringverletzung
anterior subcutaneous internal fixation; pelvic ring injury
Release Date:2020/08/07
Licence (German):License LogoDeutsches Urheberrecht mit Print on Demand