• search hit 1 of 4
Back to Result List

Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation

Please always quote using this URN: urn:nbn:de:bvb:20-opus-136002
  • Background: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. Methods: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. Results: Sixty-threeBackground: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. Methods: We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. Results: Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 +/- 4 years, and 25 patients (55.6 %) were female. Mean aortic annulus diameter was 20.3 +/- 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 +/- 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over-or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 % of patients. Conclusions: CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies.show moreshow less

Download full text files

Export metadata

Metadaten
Author: Mohammad A. Sherif, Hüseyin Ince, Octavian Maniuc, Therese Reiter, Wolfram Voelker, Georg Ertl, Alper Öner
URN:urn:nbn:de:bvb:20-opus-136002
Document Type:Journal article
Faculties:Medizinische Fakultät / Medizinische Klinik und Poliklinik I
Language:English
Parent Title (English):BMC Cardiovascular Disorders
Year of Completion:2015
Volume:15
Issue:181
Source:BMC Cardiovascular Disorders (2015) 15:181 DOI 10.1186/s12872-015-0181-3
DOI:https://doi.org/10.1186/s12872-015-0181-3
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:TAVI; anatomy; complex; dimensions; echocardiography; impact; multicenter; multidetector computed-tomography; outcomes; regurgitation; replacement; root; sizing
Release Date:2016/07/11
Licence (German):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung