• search hit 1 of 1
Back to Result List

Vergleich der rheologischen Qualität von Erythrozytenkonzentraten, gewonnen durch herkömmliche Vollblutspende oder Multikomponentenspende und Einfluß der Entnahmeverfahren auf ausgewählte rheologische Laborparameter und in-vivo-Mikrozirkulation des Spenders

Comparison of the rheological quality of red cell concentrates extracted from conventional whole blood donation or multicomponent apheresis and examination of the influence of the extraction method on selected rheological laboratory parameters and in-vivo microcirculation of the donor

Please always quote using this URN: urn:nbn:de:bvb:20-opus-6055
  • 20 Probanden nahmen im prospektiven Paarvergleich im Abstand von mindestens 8 Wochen im cross-over-Verfahren an je einer Vollblutspende (VBS) und einer maschinellen Multikomponentenspende (MKS) teil. Die erzeugten leukozyten-depletierten Erythrozytenkonzentrate beider Gruppen wurden mittels CPD-50 antikoaguliert und über einen Zeitraum von 63 Tagen in PAGGS-Mannitol gelagert. Beurteilt wurden zum einen rheologische in-vitro-Parameter bei Spendern und Blutkonserven in zweiwöchentlichen Abständen: oszillierende Kapillarviskosimetrie,20 Probanden nahmen im prospektiven Paarvergleich im Abstand von mindestens 8 Wochen im cross-over-Verfahren an je einer Vollblutspende (VBS) und einer maschinellen Multikomponentenspende (MKS) teil. Die erzeugten leukozyten-depletierten Erythrozytenkonzentrate beider Gruppen wurden mittels CPD-50 antikoaguliert und über einen Zeitraum von 63 Tagen in PAGGS-Mannitol gelagert. Beurteilt wurden zum einen rheologische in-vitro-Parameter bei Spendern und Blutkonserven in zweiwöchentlichen Abständen: oszillierende Kapillarviskosimetrie, Erythrozytenaggregometrie und Filtrometrie. Zudem kam bei den Maschinenspendern die neue Methode der Laser-Doppler-Anemometrie zur Ermittlung der kapillären in-vivo-Blutflußgeschwindigkeit in Einzelkapillaren zur Anwendung. Konkordant kam es in beiden Gruppen zum Ansteigen der viskösen Viskosität der Erythrozytenkonzentrate mit überproportionalem Anstieg nach 7 Wochen Lagerung. Die elastische Viskosität stieg ebenfalls in beiden Gruppen an, hier wurden in der Gruppe der Vollblutspender bereits zu Beginn deutlich höhere Werte gemessen, welche in der Vergleichsgruppe erst nach 49 Tagen erreicht wurden. Bei den Blutspendern konnten 24 Stunden nach Spende Veränderungen von visköser und elastischer Viskosität gezeigt werden, welche stark mit Erythrozytenanzahl, Hämoglobin und Hämatokrit korrelierten. Bei konstanten Werten der dynamischen Erythrozytenaggregation zeigte die statische Erythrozytenaggregation bei den Vollblutspenden nach drei Wochen eine Zunahme, in der MKS-Gruppe imponierte ein biphasisches Verhalten mit initialer Abnahme der Lichttransmission. Unabhängig vom Spendeverfahren, trat eine deutliche Abnahme der Filtrierbarkeit der Produkte in beiden Gruppen in den letzten beiden Lagerungswochen auf. Eindrucksvoll war die Reduktion der Filterokklusionsrate auf unter 40 % des Ausgangswertes durch Leukozytenfiltration vor der Lagerung. Bereits 1 Stunde nach der Spende konnten filtrometrische Veränderungen bei den Spendern gezeigt werden, das Signifikanzniveau wurde hier nur knapp verfehlt. Die Bestimmung der kapillären Blutflußgeschwindigkeit zeigte eine Stunde nach Spende eine deutliche Abnahme auf 81 % des Ausgangswertes (p=0,064) in der Gruppe der Maschinenspender. Dies wird als Ausdruck einer diskreten Kreislaufbelastung durch das Aphereseverfahren gewertet.show moreshow less
  • 20 test persons took part in the prospective pair-comparison at intervals of at least eight weeks in the cross-over method, consisting of one whole blood donation and one automated cytapheresis. The produced leukocyte-depleted red blood cell concentrates of both groups were anticoagulated via CPD-50 and stored in PAGGS-Mannitol for a period of 63 days. Rheological in-vitro parameters of the donors and the products were evaluated at intervals of two weeks: oscillating capillary viscosimetry, erythrocyte aggregometry and filtrometry. Furthermore20 test persons took part in the prospective pair-comparison at intervals of at least eight weeks in the cross-over method, consisting of one whole blood donation and one automated cytapheresis. The produced leukocyte-depleted red blood cell concentrates of both groups were anticoagulated via CPD-50 and stored in PAGGS-Mannitol for a period of 63 days. Rheological in-vitro parameters of the donors and the products were evaluated at intervals of two weeks: oscillating capillary viscosimetry, erythrocyte aggregometry and filtrometry. Furthermore the new method of laser-Doppler anemometry was implemented with the cytapheresis group in order to determine the capillary in-vivo blood flow velocity in single-capillaries. In both groups the viscous viscosity of the red blood cell concentrates increased by a disproportionately rise after seven weeks in storage. The elastic viscosity also increased in both groups. Notably higher values were gauged in the cytapheresis group already at the beginning, which were reached by the comparison group only after 49 days. 24 hours after the donation alterations of viscous and elastic viscosity of the donors’ blood could be observed, highly correlating with number of erythrocytes, hemoglobin and hematocrit. With the values of the dynamic erythrocyte aggregation remaining constant the static erythrocyte aggregation of whole blood donors showed an increase after three weeks. Within the automated cytapheresis group a biphasic behaviour with initial decrease of light transmission was noticeable. Independent of the donation method a significant decrease of the products’ filterability could be noted in both groups during the last two weeks in storage. The reduction of the clogging rate to below 40 % of the initial value by means of leukocyte filtration before putting the samples into storage was quite impressive. Filtrometric alterations within the donor groups could be verified only one hour after the donation. The level of significance was not reached here. In the automated cytapheresis group the capillary blood flow velocity showed a significant decrease to 81 % of its initial value (p=0,064) one hour after the donation. This is seen as the expression of a discrete strain on the donor’s circulation caused by the apheresis.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Thomas Lang
URN:urn:nbn:de:bvb:20-opus-6055
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I)
Date of final exam:2003/06/17
Language:German
Year of Completion:2002
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:Apherese; Blut; Erythrozyten; Qualität; Rheologie
blood; cytapheresis; erythrocyte; quality; rheology
Release Date:2003/07/11
Advisor:Prof. Dr. Dieter Wiebecke