Vergleich der biochemischen Qualität von Erythrozytenkonzentraten, gewonnen durch Multikomponentenspende oder herkömmliche Vollblutspende und Einfluß auf ausgewählte biochemische Laborparameter und in-vivo-Mikrozirkulation des Spenders

Comparison of the biochemical quality of packed red cells, produced by either mcs+ cell separator or by whole blood donation and the influence on selected biochemical bloodparameters and the in-vivo microcirculation of the donor

Please always quote using this URN: urn:nbn:de:bvb:20-opus-6035
  • Die vorliegende Arbeit untersuchte in einem prospektiven Paarvergleich mit cross-over die biochemische Qualität von Erythrozytenkonzentraten, die mittels konventioneller Vollblutspende (VBS) bzw. maschineller Multikomponentenspende (MKS) gewonnen und über einen Zeitraum von 63 Tagen gelagert wurden. Dabei wurde die Überlebensfähigkeit der roten Zellen anhand des ATP-Gehaltes, ihre Sauerstoffabgabefähigkeit mittels des 2,3-DPG-Spiegels sowie die Zellschädigung durch die Bestimmung mehrerer Hämolyseparameter bewertet. Dabei fanden sich,Die vorliegende Arbeit untersuchte in einem prospektiven Paarvergleich mit cross-over die biochemische Qualität von Erythrozytenkonzentraten, die mittels konventioneller Vollblutspende (VBS) bzw. maschineller Multikomponentenspende (MKS) gewonnen und über einen Zeitraum von 63 Tagen gelagert wurden. Dabei wurde die Überlebensfähigkeit der roten Zellen anhand des ATP-Gehaltes, ihre Sauerstoffabgabefähigkeit mittels des 2,3-DPG-Spiegels sowie die Zellschädigung durch die Bestimmung mehrerer Hämolyseparameter bewertet. Dabei fanden sich, ungeachtet des Herstellungsganges (VBS - MKS), in den ersten drei Wochen nur geringfügige Hinweise auf eine lagerungsbedingte Alteration der Erythrozyten. Nach der dritten Lagerungswoche nahm die Qualität der Erythrozytenkonzentrate aufgrund einer zunehmenden Zellschädigung und Verarmung an Energieträgern ab. Aus den erzielten Resultaten geht hervor, daß keines der beiden Spendeverfahren dem anderen wesentlich überlegen ist, sondern beide Methoden Präparate von hoher Qualität lieferten. Der zweite Teil der Arbeit befaßte sich mit den Auswirkungen der Spende auf die Blut-flußgeschwindigkeit und Blutflußrate in den Fingerkapillaren der Blutspender. Zum Zeitpunkt vor, eine Stunde nach sowie 24 Stunden nach der Spende wurde die Blutflußrate kapillarmikroskopisch mit dem CAM 1 Laser Doppler Anemometer am Fingermittelglied des dritten Fingers der linken Hand bestimmt. Dabei ließen sich keine signifikanten Steigerungen der kapillären Blutflußrate nachweisen.show moreshow less
  • In the present thesis, the biochemical quality of stored erythrocytes, produced by either whole blood donation or by mcs+ cell separator was investigated over a period of 63 days of storage. Therefore, both the survival ratio of the erythrocytes was valued by the content of ATP as well as the reaction of the oxygen dissociation curve messured by the content of 2,3 DPG. Several parameters investigating the ratio of hemolysis were used to describe the extent of the red cell damage during the storage time. The results showed that the whole bloodIn the present thesis, the biochemical quality of stored erythrocytes, produced by either whole blood donation or by mcs+ cell separator was investigated over a period of 63 days of storage. Therefore, both the survival ratio of the erythrocytes was valued by the content of ATP as well as the reaction of the oxygen dissociation curve messured by the content of 2,3 DPG. Several parameters investigating the ratio of hemolysis were used to describe the extent of the red cell damage during the storage time. The results showed that the whole blood donation as well as the mcs+ cell separator produced packed red cells of high quality. Within the first three weeks of storage the quality of the packed erythrocytes was nearly not influenced by the storing conditions. After this observation period the damage of the red cells was increasing because of the decreasing levels of ATP and 2,3-DPG. In the second part of this thesis the influence of a blood donation on the blood flow velocity in the microcirculation of the donors was investigated. Therefore, the blood flow velocity was measured before the donation as well as one hour or 24 hours respectively after the donation. Measurements were made in the capillaries of the third finger (interphalangeal joint), valued by the CAM 1 laser doppler anemometer. The results showed that despite a blood donation of min. 500 ml an increase of the blood flow velocity could not be found.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Ulrike Stephan
URN:urn:nbn:de:bvb:20-opus-6035
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I)
Date of final exam:2003/06/17
Language:German
Year of Completion:2003
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:2; 3-DPG; ATP; Erythrozytenkonzentrat; Kapillarmikroskopie; Multikomponentenspende
2; 3-DPG; ATP; Clinical capillaroscopy; MCS+ cell separator; Quality of packed red cells
Release Date:2003/07/15
Advisor:Prof. Dr. med. Dieter Wiebecke