"Eignet sich die kritische Flimmerfrequenz zur Diagnose einer minimal hepatischen Enzephalopathie?"

"Is the critical flicker frequency suitable for the diagnosis of minimal hepatic encephalopathy?"

Please always quote using this URN: urn:nbn:de:bvb:20-opus-349363
  • Korrelation und Kontingenzprüfung von Kritischer Flimmerfrequenz als diagnostischem Mittel bei minimal hepatischer Enzephalopathie mit anderen etablierten diagnostischen Mitteln und beschreibenden Parametern. In den Ergebnissen lediglich Korrelation mit Alertness Testung in der Testbatterie. Minimal hepatische Enzephalopathie braucht zur Diagnostik mindestens 2 verschiedene ergänzende diagnostische Verfahren (neuropsychologisch und -physiologisch), um sicher entdeckt werden zu können. Bei nur einem Testverfahren blieben zahlreicheKorrelation und Kontingenzprüfung von Kritischer Flimmerfrequenz als diagnostischem Mittel bei minimal hepatischer Enzephalopathie mit anderen etablierten diagnostischen Mitteln und beschreibenden Parametern. In den Ergebnissen lediglich Korrelation mit Alertness Testung in der Testbatterie. Minimal hepatische Enzephalopathie braucht zur Diagnostik mindestens 2 verschiedene ergänzende diagnostische Verfahren (neuropsychologisch und -physiologisch), um sicher entdeckt werden zu können. Bei nur einem Testverfahren blieben zahlreiche Betroffene unentdeckt. Möglicherweise ist das verschiedenen pathophysiologischen Subgruppen geschuldet.show moreshow less
  • Correlation and contingency testing of critical flicker frequency as a diagnostic tool in minimal hepatic encephalopathy with other established diagnostic tools and descriptive parameters. In the results only correlation with alertness testing in the test battery. Minimal hepatic encephalopathy requires at least 2 different complementary diagnostic procedures (neuropsychological and -physiological) in order to be reliably detected. With only one test procedure, many affected persons remain undetected. This may be due to differentCorrelation and contingency testing of critical flicker frequency as a diagnostic tool in minimal hepatic encephalopathy with other established diagnostic tools and descriptive parameters. In the results only correlation with alertness testing in the test battery. Minimal hepatic encephalopathy requires at least 2 different complementary diagnostic procedures (neuropsychological and -physiological) in order to be reliably detected. With only one test procedure, many affected persons remain undetected. This may be due to different pathophysiological subgroups.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Marlies GöserGND
URN:urn:nbn:de:bvb:20-opus-349363
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Neurologische Klinik und Poliklinik
Referee:Prof. Dr. Daniel Zeller
Date of final exam:2023/10/05
Language:German
Year of Completion:2024
DOI:https://doi.org/10.25972/OPUS-34936
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
GND Keyword:Encephalopathia hepaticaGND
Tag:Kritische Flimmerfrequenz; minimal hepatische Enzephalopathie
PHES; TAP Alertness; critical flimmer frequency
Release Date:2024/02/20
Licence (German):License LogoDeutsches Urheberrecht mit Print on Demand