Neugeborenen-Hörscreening mit dem BERAphone® - Beeinflussung der Nachweiszeit durch Vigilanzzustand und Reizrate

ABR-based newborn hearing screening with MB11 BERAphone® - Impact of the vigilance level and the stimulus rate on the screening result time

Please always quote using this URN: urn:nbn:de:bvb:20-opus-180526
  • Hintergrund: Für die zeitgerechte Diagnose und Therapie einer permanenten kindlichen Hörstörung ist ein universelles Neugeborenen-Hörscreening (NHS) unverzichtbar. Der Goldstandard für das NHS basiert auf der Ableitung von akustisch evozierten Hirnstammpotentialen (Brainstem evoked response audiometry, BERA). An der Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen der Universität Würzburg erfolgt das NHS mit dem automatischen BERA-Testsystem MAICO MB11 BERAphone® (MAICO Diagnostics GmbH). InHintergrund: Für die zeitgerechte Diagnose und Therapie einer permanenten kindlichen Hörstörung ist ein universelles Neugeborenen-Hörscreening (NHS) unverzichtbar. Der Goldstandard für das NHS basiert auf der Ableitung von akustisch evozierten Hirnstammpotentialen (Brainstem evoked response audiometry, BERA). An der Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen der Universität Würzburg erfolgt das NHS mit dem automatischen BERA-Testsystem MAICO MB11 BERAphone® (MAICO Diagnostics GmbH). In vorausgegangenen Arbeiten zur Optimierung dieser Messmethode ergaben sich Hinweise auf eine Beziehung zwischen dem Vigilanzzustand (Wachheitsgrad) der Neugeborenen und der Reizrate. In der vorliegenden Studie wurde untersucht, ob durch die Verwendung einer bestimmten Reizrate in Abhängigkeit vom Vigilanzzustand eine Verkürzung der Messzeit bzw. der Testdauer erreicht werden kann. Methoden: An 72 Neugeborenen (Altersmittelwert: 2,3 Tage) wurden 409 Messungen mit dem MB11 BERAphone® im Rahmen des universellen NHS der Universitäts-HNO-Klinik Würzburg durchgeführt. Es wurden drei verschiedene Vigilanzzustände (wach, dösend, schlafend) mit den Reizraten 20/s, 40/s, 60/s, 80/s, 90/s, 100/s untersucht. Ergebnisse: Es konnte gezeigt werden, dass die Nachweiszeit beim NHS vom Vigilanzzustand der Neugeborenen während der Untersuchung beeinflusst wurde. Bei schlafenden Neugeborenen wurden kürzere Nachweiszeiten erzielt als bei wachen Neugeborenen. In Abhängigkeit von der verwendeten Reizrate waren diese Nachweiszeitunterschiede zwischen den schlafenden und wachen Neugeborenen unterschiedlich groß. Bei einer Reizrate von 60/s war im Vergleich zu den übrigen Reizraten (20/s, 40/s, 80/s, 90/s, 100/s) kein signifikanter Unterschied zwischen den Nachweiszeiten der wachen und schlafenden Neugeborenen nachweisbar. Fazit: Eine Reizrate von 60/s ist für das NHS vorteilhaft. Diese Stimulationsrate wird am wenigsten durch die Vigilanz der Neugeborenen beeinflusst. Es treten somit weniger vigilanzbedingte Verlängerungen der Screening-Zeit auf.show moreshow less
  • Background: For an early diagnosis and therapy of an infant hearing loss a newborn hearing screening (NHS) is indispensable. The gold standard for NHS is based on auditory brainstem responses (ABR). The Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery at Würzburg University Hospital uses the MB 11 with BERAphone® (MAICO Diagnostic GmbH, Berlin) for NHS. This device utilizes an optimized Chirp stimulus at 35 dBnHL. Previous studies showed an indication of an impact of different vigilance levels onBackground: For an early diagnosis and therapy of an infant hearing loss a newborn hearing screening (NHS) is indispensable. The gold standard for NHS is based on auditory brainstem responses (ABR). The Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery at Würzburg University Hospital uses the MB 11 with BERAphone® (MAICO Diagnostic GmbH, Berlin) for NHS. This device utilizes an optimized Chirp stimulus at 35 dBnHL. Previous studies showed an indication of an impact of different vigilance levels on the results of NHS. The present study was aimed at finding an optimum repetition rate for the chirp stimulus dependent on the vigilance level that facilitates a short response-detection and accordingly a short screening result time. Methods: 409 measurements taken on 72 Newborns were included in this study. 3 different vigilance levels (awake, dozing, sleeping) were analyzed using the stimulus rates 20/s, 40/s, 60/s, 80/s, 90/s, 100/s. Results: It could be shown that there is an impact of the vigilance level of the newborns on the screening result time. In sleeping newborns significantly lower mean screening result times could be achieved compared to awake newborns. This differences between the screening result times varied depending on the utilized stimulus rate. At a stimulus rate of 60/s there were no significant differences of the screening result times between the sleeping and awake newborns compared to the other stimulus rates (20/s, 40/s, 80/s, 90/s, 100/s). Conclusions: A stimulus rate of 60/s is advantageous for NHS. This stimulus rate is less influenced by the vigilance level of the Newborns and leads to less extensions of the screening result time.show moreshow less

Download full text files

Export metadata

Metadaten
Author: Enrique Murillo
URN:urn:nbn:de:bvb:20-opus-180526
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen
Referee:Prof. Dr.-Ing. Mario Cebulla, Prof. Dr. med. Wafaa Shehata-Dieler
Date of final exam:2019/04/10
Language:German
Year of Completion:2019
DOI:https://doi.org/10.25972/OPUS-18052
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
GND Keyword:Neugeborene; Hörtest
Tag:ASSR; BERA; Chirp-Reiz; Neugeborenenhörscreening; Stimulationsrate; Vigilanz
auditory evoked potentials; newborn hearing screening; stimulus rate; vigilance
Release Date:2019/05/15
Licence (German):License LogoDeutsches Urheberrecht mit Print on Demand