The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 8 of 8519
Back to Result List

Vergleich von Dual- und Single-Source Dual-Energy CT in der Diagnostik der akuten Lungenarterienembolie hinsichtlich Bildqualität und Strahlendosis

Comparison of Dual- and Single-Source Dual-Energy CT for the Diagnosis of Acute Pulmonary Embolism Regarding Image Quality and Radiation Dose

Please always quote using this URN: urn:nbn:de:bvb:20-opus-352064
  • Hintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) können mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik ermöglicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualität sowie der Strahlendosis mit einem etabliertem DS-DECT-Gerät verglichen werden. Material undHintergrund: Die CT-Pulmonalisangiographie (CTPA) ist diagnostischer Goldstandard der Diagnostik der Lungenarterienembolie (LAE). Durch Dual-Energy CT (DECT) können mithilfe von Joddistributionskarten LAEs auf Segment- und Subsegmentebene besser detektiert werden. Neben der etablierten Dual-Source-Technik ermöglicht ein Split-Filter eine DECT-Akquisition mit Single-Source-Scannern. Ein solcher SF-DECT-Scanner sollte hinsichtlich der Bildqualität sowie der Strahlendosis mit einem etabliertem DS-DECT-Gerät verglichen werden. Material und Methoden: Insgesamt wurden 135 Patienten eingeschlossen, die eine CTPA erhielten: 68 erhielten einen DS-DECT-Scan mit 90/Sn150 kV und 67 einen SF-DECT-Scan mit Au/Sn120 kV. Für beide Protokolle wurden farbkodierte Joddistributionskarten erstellt. Die objektive (CT-Abschwächung in relevanten Gefäßen in HU, Signal-Rausch-Verhältnis (SNR), Kontrast-Rausch-Verhältnis (CNR), perfused blood volume (PBV)) und subjektive Bildqualität (2 Befunder (B), 5-Punkte-Likert-Skala) sowie Dosisparameter wurden erhoben und verglichen. Ergebnisse: Alle CTPAs waren von diagnostischer Qualität. Ihre subjektive Bildqualität wurde in 80,9/82,4% (B1/B2) der DS-DECT und in 77,6/76,1% der SF-DECT als exzellent oder gut bewertet. Die subjektive Bildqualität der Joddistributionskarten der SF-DECT wurde von beiden Befundern als schlechter beurteilt. Die HU-Werte der relevanten Gefäße unterschieden sich nicht signifikant (p>0.05), SNR und CNR der SF-Gruppe waren in zentralen Gefäßen jedoch höher (p<0.05); die PBV-Werte der SF-Gruppe waren teils höher (p<0.05). Alle erhobenen Dosisparameter waren in der SF-Gruppe höher (p<0,05). Konklusion: In der diagnostischen Abklärung eines V.a. eine akute LAE ermöglicht der Einsatz eines Split-Filters an einem Single-Source-CT-Scanner eine Dual-Energy-Untersuchung. Dies geht im Vergleich zu etablierten DS-Scannern jedoch mit einer schlechteren Qualität der Joddistributionskarten und einer höheren Strahlendosis einher.show moreshow less
  • Background: CT pulmonary angiography (CTPA) has established as reference standard in the diagnostic workup of suspected pulmonary embolism (PE). With dual-energy CT (DECT), iodine maps can help to detect segmental and subsegmental PEs. Next to established dual-source techniques, the use of a split-filter enables DECT acquisition with single-source scanners. This study compared a SF-DECT scanner with an established DS-DECT scanner with regard to image quality and radiation dose. Material and Methods: A total of 135 patients receiving a CTPABackground: CT pulmonary angiography (CTPA) has established as reference standard in the diagnostic workup of suspected pulmonary embolism (PE). With dual-energy CT (DECT), iodine maps can help to detect segmental and subsegmental PEs. Next to established dual-source techniques, the use of a split-filter enables DECT acquisition with single-source scanners. This study compared a SF-DECT scanner with an established DS-DECT scanner with regard to image quality and radiation dose. Material and Methods: A total of 135 patients receiving a CTPA were included: 68 received a DS-DECT scan with 90/Sn 150 kV and 67 received a SF-DECT scan with Au/Sn 120 kV. Color-coded iodine-distribution maps were reconstructed for both protocols. Objective (CT attenuation in relevant vessels in HU, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), perfused blood volume (PBV)) and subjective image quality (2 readers (R), 5-point Likert scale) as well as radiation dose parameters were documented and compared. Results: All CTPAs were of diagnostic image quality. Subjective image quality was rated as excellent or good in 80,9/82,4% (R1/R2) of DS-DECT scans and in 77,6/76,1% of SF-DECT scans. Subjective image quality of iodine maps of SF-DECT scans was rated lower by both readers. For objective image quality, CT attenuation in HU of relevant vessels did not differ significantly (p>0.05), while SNR and CNR of central vessels in the SF-collective were significantly higher (p<0.05); some PBV-values of the SF-collective were significantly higher (p<0.05). All assessed radiation dose parameters were significantly higher in the SF-collective (p<0.05). Conclusion: In the diagnostic workup of suspected PE the use of a split-filter enables dual-energy acquisition with a single-source CT scanner. However, this is associated with a lower image quality of iodine maps and a higher radiation dose compared to established DS scanners.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Pauline Luisa PannenbeckerORCiD
URN:urn:nbn:de:bvb:20-opus-352064
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik)
Referee:PD Dr. Dr. Bernhard Petritsch
Date of final exam:2024/03/08
Language:German
Year of Completion:2024
DOI:https://doi.org/10.25972/OPUS-35206
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
GND Keyword:LungenembolieGND; Dual-Source-ComputertomographieGND; ComputertomografieGND; StrahlendosisGND; BildqualitätGND
Tag:Image Quality
Single-Source-Dual-Energy-CT; Split-Filter-Dual-Energy-CT
Release Date:2024/03/20
Licence (German):License LogoCC BY-NC-ND: Creative-Commons-Lizenz: Namensnennung, Nicht kommerziell, Keine Bearbeitungen 4.0 International