Korrelation der intraoperativen Nervevaluation zur postoperativen Stimmfunktion bei Schilddrüsenoperationen

Correlation of intraoperative nerve evaluation of the postoperative vocal cord function after thyroid surgery

Please always quote using this URN: urn:nbn:de:bvb:20-opus-79014
  • In dieser Studie wurde versucht, durch das intraoperative Monitoring des Nervus vagus bestimmte Parameter zu definieren, welche einen intraoperativ drohenden Schaden des Nervus laryngeus recurrens aufzeigen könnten. Im Rahmen der Gesamtstudie erfolgte hier die Auswertung der im Marienkrankenhaus Kassel erhobenen Parameter Amplitude, Signalbreite und Latenz des Nervus vagus nach intraoperativem Ausdruck. Es erfolgte die Auswertung von 158 nerves at risk bei 113 Patienten. Erfasst wurden Patienten, bei denen eine near-total oderIn dieser Studie wurde versucht, durch das intraoperative Monitoring des Nervus vagus bestimmte Parameter zu definieren, welche einen intraoperativ drohenden Schaden des Nervus laryngeus recurrens aufzeigen könnten. Im Rahmen der Gesamtstudie erfolgte hier die Auswertung der im Marienkrankenhaus Kassel erhobenen Parameter Amplitude, Signalbreite und Latenz des Nervus vagus nach intraoperativem Ausdruck. Es erfolgte die Auswertung von 158 nerves at risk bei 113 Patienten. Erfasst wurden Patienten, bei denen eine near-total oder Hemithyreoidektomie, Thyreoidektomie oder subtotale Resektion ein- oder beidseitig erfolgte. In unserem Patientenkollektiv ließ sich eine signifikant längere Latenz des linken Nervus vagus als rechts nachweisen. Bei Männern fand sich eine signifikant längere Latenz des linken Nervus vagus sowohl prä als auch post resectionem gegenüber Frauen. Es zeigten sich keine signifikanten Veränderungen zwischen den prä und post resectionem erhobenen Parametern bezogen auf Alter, Geschlecht, Operationsdauer und Operationsindikation. Insbesondere bei Re- oder Rezidiveingriffen konnte in unserem Patientengut keine signifikante Korrelation der gemessenen Parameter zur postoperativen Stimmbandfunktion nachgewiesen werden. Aus unseren gemessenen Parametern konnten wir keine Rückschlüsse von intraoperativen Veränderungen der gemessenen Parameter auf die postoperative Stimmbandfunktion ziehen. Im Rahmen der Multicenterstudie haben unsere Daten jedoch dazu beigetragen, dass Normwerte für das intraoperative Neuromonitoring bei Schilddrüsenoperationen definiert werden konnten. Diese ermöglichen es vielleicht zukünftigen Studien Muster zu finden, welche zu einer Senkung der Rate an permanenten postoperativen Recurrensparesen führen könnten.show moreshow less
  • The possible effect of recurrent laryngeal nerve (RLN) damage on vagal nerve (VN) monitoring during thyroid surgery was evaluated. Parameters were amplitude, duration and latency of signals. 158 nerves at risk in 113 thyroid procedures were taken into evaluation. Significant findings were a delayed latency of the left VN in comparison to the right. Male had a longer latency of left VN compared to female pre and post manipulation. No significant changes pre to post manipulation were found for age, gender, duration of surgery and diagnosis. ThisThe possible effect of recurrent laryngeal nerve (RLN) damage on vagal nerve (VN) monitoring during thyroid surgery was evaluated. Parameters were amplitude, duration and latency of signals. 158 nerves at risk in 113 thyroid procedures were taken into evaluation. Significant findings were a delayed latency of the left VN in comparison to the right. Male had a longer latency of left VN compared to female pre and post manipulation. No significant changes pre to post manipulation were found for age, gender, duration of surgery and diagnosis. This includes all recurrent thyroid procedures. Thus, in our investigation, no forecast for vocal cord function can be obtained by the given parameters. Nevertheless, the obtained data contributed to the definition of standard parameters in neuromonitoring during thyroid surgery. These might help further studies to detect patterns of imminent vocal cord dysfunction and thus help to reduce vocal cord palsy.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Katrin Schotte
URN:urn:nbn:de:bvb:20-opus-79014
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I)
Date of final exam:2013/03/07
Language:German
Year of Completion:2012
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
GND Keyword:Neuromonitoring
Tag:Neuromonitoring; Recurrensparese; Schilddrüsenoperation
Neuromonitoring; Thyroid surgery; recurrent nerve palsy
Release Date:2013/07/22
Advisor:PD Dr. med. W. Hamelmann
Licence (German):License LogoCC BY-NC-ND: Creative-Commons-Lizenz: Namensnennung, Nicht kommerziell, Keine Bearbeitung