• Treffer 3 von 3
Zurück zur Trefferliste

Restoring the patient's pre-arthritic posterior slope is the correct target for maximizing internal tibial rotation when implanting a PCL retaining TKA with calipered kinematic alignment

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-240996
  • Introduction: The calipered kinematically-aligned (KA) total knee arthroplasty (TKA) strives to restore the patient's individual pre-arthritic (i.e., native) posterior tibial slope when retaining the posterior cruciate ligament (PCL). Deviations from the patient's individual pre-arthritic posterior slope tighten and slacken the PCL in flexion that drives tibial rotation, and such a change might compromise passive internal tibial rotation and coupled patellofemoral kinematics. Methods: Twenty-one patients were treated with a calipered KA TKA andIntroduction: The calipered kinematically-aligned (KA) total knee arthroplasty (TKA) strives to restore the patient's individual pre-arthritic (i.e., native) posterior tibial slope when retaining the posterior cruciate ligament (PCL). Deviations from the patient's individual pre-arthritic posterior slope tighten and slacken the PCL in flexion that drives tibial rotation, and such a change might compromise passive internal tibial rotation and coupled patellofemoral kinematics. Methods: Twenty-one patients were treated with a calipered KA TKA and a PCL retaining implant with a medial ball-in-socket and a lateral flat articular insert conformity that mimics the native (i.e., healthy) knee. The slope of the tibial resection was set parallel to the medial joint line by adjusting the plane of an angel wing inserted in the tibial guide. Three trial inserts that matched and deviated 2°> and 2°< from the patient's pre-arthritic slope were 3D printed with goniometric markings. The goniometer measured the orientation of the tibia (i.e., trial insert) relative to the femoral component. Results: There was no difference between the radiographic preoperative and postoperative tibial slope (0.7 ± 3.2°, NS). From extension to 90° flexion, the mean passive internal tibial rotation with the pre-arthritic slope insert of 19° was greater than the 15° for the 2°> slope (p < 0.000), and 15° for the 2°< slope (p < 0.000). Discussion: When performing a calipered KA TKA with PCL retention, the correct target for setting the tibial component is the patient's individual pre-arthritic slope within a tolerance of ±2°, as this target resulted in a 15–19° range of internal tibial rotation that is comparable to the 15–18° range reported for the native knee from extension to 90° flexion.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Alexander J. Nedopil, Connor Delman, Stephen M. Howell, Maury L. Hull
URN:urn:nbn:de:bvb:20-opus-240996
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Lehrstuhl für Orthopädie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Journal of Personalized Medicine
ISSN:2075-4426
Erscheinungsjahr:2021
Band / Jahrgang:11
Heft / Ausgabe:6
Aufsatznummer:516
Originalveröffentlichung / Quelle:Journal of Personalized Medicine (2021) 11:6, 516. https://doi.org/10.3390/jpm11060516
DOI:https://doi.org/10.3390/jpm11060516
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Freie Schlagwort(e):kinematic alignment; rotation; slope; total knee arthroplasty; total knee replacement
Datum der Freischaltung:02.09.2022
Datum der Erstveröffentlichung:04.06.2021
Lizenz (Deutsch):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International