Elektrophysiologische Untersuchungen am Nervus laryngeus recurrence des Menschen mit verschiedenen Verfahren des Neuromonitorings

Electro-physiological studies of the human recurrent nerve with different techniques of neuromonitoring

Please always quote using this URN: urn:nbn:de:bvb:20-opus-23037
  • Einleitung: In den letzten Jahren hat sich das intraoperative, elektrophysiologische Neuromonitoring des Nervus recurrens in der Schilddrüsenchirurgie mehr und mehr etabliert und durchgesetzt. Patienten und Methode: In einer prospektiven Studie wurden 79 Patienten (61 weiblich, 19 männlich) an der Schilddrüse operiert. Dabei haben wir das System Nadelelektrode, bei dem die Elektrode durch das Ligamentum crycothyroideum in den Muskulus vocalis gestochen wird (Neurosign 100, Fa. Inomed) mit dem System Tubuselektrode, bei dem die Elektroden demEinleitung: In den letzten Jahren hat sich das intraoperative, elektrophysiologische Neuromonitoring des Nervus recurrens in der Schilddrüsenchirurgie mehr und mehr etabliert und durchgesetzt. Patienten und Methode: In einer prospektiven Studie wurden 79 Patienten (61 weiblich, 19 männlich) an der Schilddrüse operiert. Dabei haben wir das System Nadelelektrode, bei dem die Elektrode durch das Ligamentum crycothyroideum in den Muskulus vocalis gestochen wird (Neurosign 100, Fa. Inomed) mit dem System Tubuselektrode, bei dem die Elektroden dem Stimmband anliegen (NIM-Response 2.0, Fa. Medtronic), verglichen. Es wurde der Nervus vagus, der Nervus laryngeus recurrens und der Nervus laryngeus superior identifiziert und ein EMG-Signal für jeden Nerv abgeleitet. Anschließend wurden hieraus Amplituden und Latenzzeizen der jeweiligen Ableitung bestimmt. Ergebnisse: Für den linken Nervus vagus ergab sich eine mittlere konstante Latenzzeit im Bereich von ca. 6,3 ms, die damit ca. 2,5 ms länger als die ebenfalls konstante Latenzzeit des rechten Nervus vagus (ungefähr 3,8 ms) war. Beim Nervus laryngeus recurrence wurde auf beiden Seiten eine konstante durchschnittliche Latenzzeit von ca. 2,2 -2,5 ms gemessen. Die Darstellung des Nervus laryngeus superior gestaltete sich technisch schwieriger und gelang nur in 37% der Fälle. Bei den identifizierten Nerven lagen im Mittel sowohl für den linken als auch für den rechten Nervus laryngeus superior mittlere konstante Latenzzeiten zwischen 1,8 ms und 2,0 ms vor. Zwischen beiden Neuromonitoringsystemen („Tubuselektrode“ vs. „Nadelelektrode“) fanden sich bezüglich der Latenzzeiten keine Unterschiede. Die Bestimmung der Amplituden ergab für alle drei Nerven bei den absoluten Messwerten ein inhomogenes Bild. Es zeigte sich allerdings, dass mit der Nadelelektrode ein im Mittel ca. drei- bis fünffach stärkeres Signal als mit der Tubuselektrode abgeleitet werden konnte. Schlussfolgerung: Aus den Ergebnissen kann die Forderung abgeleitet werden, dass das Neuromonitoring in Zukunft nicht nur zur Identifikation des Nervus laryngeus recurrence genutzt werden sollte, sondern auch zur Bestimmung von Amplitude und Latenzzeit, da insbesondere bei Amplitudenveränderungen mögliche Nervenschädigungen frühzeitig erkannt werden könnten. Da mit der Nadelelektrode grundsätzlich höhere Signalstärken zu erfassen waren, ist diese zu bevorzugen. Das Neuromonitoring hat sich als sinnvolles technisches Hilfsmittel bei Schilddrüseneingriffen herausgestellt, kann helfen die Rekurrenspareserate zu senken, erhöht die Sicherheit in der Ausbildung von jungen Operateuren und bietet die Möglichkeit der heute geforderten Dokumentation über die Nervendarstellung.show moreshow less
  • Introduction: In the last few years the use of intraoperative electrophysiological monitoring of the recurrent laryngeal nerve in thyroid gland surgery has become more and more important. Patients and method: In a prospective study 79 patients (61 female, 18 male) underwent surgery at the thyroid gland. For these patients, we compared the use of intramuscular needle electrodes, (inserted into the vocal muscle through the conic ligament (Neurosign 100, Fa. Inomed)), to the endolaryngeal tube, where the electrodes were laying against the vocalIntroduction: In the last few years the use of intraoperative electrophysiological monitoring of the recurrent laryngeal nerve in thyroid gland surgery has become more and more important. Patients and method: In a prospective study 79 patients (61 female, 18 male) underwent surgery at the thyroid gland. For these patients, we compared the use of intramuscular needle electrodes, (inserted into the vocal muscle through the conic ligament (Neurosign 100, Fa. Inomed)), to the endolaryngeal tube, where the electrodes were laying against the vocal cord (NIM-Response 2.0, Fa. Medtronic). We identified the vagal nerv, the recurrent nerve and the superior laryngeal nerve and obtained an EMG-signal of each nerve. The amplitudes and latency times were recorded and documented for each nerve. Results: For the left vagal nerve we found a constant latency time around 6.3 ms, in comparison to the constant latency time of the right vagal nerv (around 3.8 ms). The recurrent nerve showed on both sides a constant latency time of about 2.2-2-5 ms. The identification of the superior laryngeal nerve was technically more difficult and was successful in only 37% of cases. In these cases we found a constant latency time between 1.8 and 2.0 ms for both sides. We did not find any differences in the latency times between the two neuromonitoring-systems (needle vs. tube). The measured values of the amplitudes for all three nerves showed an inhomogeneous picture. Nevertheless, in all cases the signal from the needle-system was three to five times stronger in comparison to the tube-system. Conclusions: We conclude that Neuromonitoring should not only be used to identify the recurrent nerve but also to determine the amplitude and the latency time. , An observed change in the amplitude could help to detect a potential nerve injury earlier. Therefore, the needle-system should be preferred, as stronger signals can be obtained (getting higher signals ). Neuromonitoring has been proven to be a sensible and useful technical support method in thyroid gland surgery. It can help to reduce recurrent nerve paralysis, it is useful in the education of young surgeons and offers a possibility to document the identification of nerves, which is nowadays increasingly required.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Jonas Zirkler
URN:urn:nbn:de:bvb:20-opus-23037
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I)
Date of final exam:2007/06/06
Language:German
Year of Completion:2007
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:Latenzzeit; Neuromonitoring; Recurrensparese; Schilddrüsenoperation
latency time; neuromonitoring; recurrent nerve paralysis; thyroid gland surgery
Release Date:2007/07/03
Advisor:Priv.-Doz. Dr. med. W. Hamelmann