• Treffer 2 von 3
Zurück zur Trefferliste

Revision to reverse shoulder arthroplasty with retention of the humeral component Good outcome in 14 patients followed for a mean of 2.5 years

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-131621
  • Background: Revision in failed shoulder arthroplasty often requires removal of the humeral component with a significant risk of fracture and bone loss. Newer modular systems allow conversion from anatomic to reverse shoulder arthroplasty with retention of a well-fixed humeral stem. We report on a prospectively evaluated series of conversions from hemiarthroplasty to reverse shoulder arthroplasty. Methods: In 14 cases of failed hemiarthroplasty due to rotator cuff deficiency and painful pseudoparalysis (in 13 women), revision to reverseBackground: Revision in failed shoulder arthroplasty often requires removal of the humeral component with a significant risk of fracture and bone loss. Newer modular systems allow conversion from anatomic to reverse shoulder arthroplasty with retention of a well-fixed humeral stem. We report on a prospectively evaluated series of conversions from hemiarthroplasty to reverse shoulder arthroplasty. Methods: In 14 cases of failed hemiarthroplasty due to rotator cuff deficiency and painful pseudoparalysis (in 13 women), revision to reverse shoulder arthroplasty was performed between October 2006 and 2010, with retention of the humeral component using modular systems. Mean age at the time of operation was 70 (56-80) years. Pre- and postoperative evaluation followed a standardized protocol including Constant score, range of motion, and radiographic analysis. Mean follow-up time was 2.5 (2-5.5) years. Results: Mean Constant score improved from 9 (2-16) to 41 (17-74) points. Mean lengthening of the arm was 2.6 (0.9-4.7) cm without any neurological complications. One patient required revision due to infection. Interpretation Modular systems allow retainment of a well-fixed humeral stem with good outcome. There is a risk of excessive humeral lengthening.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Birgit S. Werner, Dorota Boehm, Frank Gohlke
URN:urn:nbn:de:bvb:20-opus-131621
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Lehrstuhl für Orthopädie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Acta Orthopaedica
Erscheinungsjahr:2013
Band / Jahrgang:84
Heft / Ausgabe:5
Seitenangabe:473-478
Originalveröffentlichung / Quelle:Acta Orthopaedica 2013; 84 (5): 473–478. DOI 10.3109/17453674.2013.842433
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 617 Chirurgie und verwandte medizinische Fachrichtungen
Freie Schlagwort(e):cultures; etiology; failed hemiarthroplasty; fractures; prothesis; proximal humerus
Datum der Freischaltung:18.05.2016
Lizenz (Deutsch):License LogoCC BY-NC: Creative-Commons-Lizenz: Namensnennung, Nicht kommerziell