• search hit 1 of 2
Back to Result List

A multi-center, prospective, open-label, 8-week study of certoparin for anticoagulation during maintenance hemodialysis – the membrane study

Please always quote using this URN: urn:nbn:de:bvb:20-opus-124052
  • Background Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting. Methods Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary. Results 120 patients were screened, 109 enrolled (median age 71; range 26–90 years) and 106 availableBackground Adequate anticoagulation is prerequisite for effective hemodialysis to prevent clotting in the extracorporeal circuit. We aimed providing first data on the efficacy and safety of the low-molecular-weight heparin certoparin in this setting. Methods Multicenter, open-label, 8-week trial. Patients received a single dose of 3,000 IU certoparin i.v. with additional titration steps of 600 IU and/or continuous infusion if necessary. Results 120 patients were screened, 109 enrolled (median age 71; range 26–90 years) and 106 available for efficacy analyses. The percentage of unsatisfactory dialysis results at 8 weeks due to clotting or bleeding, was 1.9% (n = 2/106; 95% confidence interval [CI] 0.23–6.65%); no major bleeding. 1.9% had moderate/severe clotting in the lines/bubble catcher and 2.8% in the dialyser at week 8. 15.7 ± 14.3% of the dialysis filters’ visual surface area was showing redness. In subgroups of patients receiving median doses of 3000 ± 0, 3000 (2400–6000) and 4200 (3000–6600) IU, plasma aXa levels at baseline, 4 and 8 weeks were 0.24 [95%CI 0.21–0.27], 0.33 [0.27–0.40] and 0.38 [0.33–0.45] aXa IU/ml at 2 h. \(C_{48h}\) was 0.01 [0.01–0.02] aXa IU at all visits. At baseline and 4 weeks \(AUC_{0-48h}\) was 2.66 [2.19–3.24] and 3.66 [3.00–4.45] aXa IU*h/ml. In 3.0% of dialyses (n = 83/2724) prolonged fistula compression times were documented. Eight patients (7.34%) had at least one episode of minor bleeding. 4) 85.3% of patients had any adverse event, 9.2% were serious without suspected drug relation; and in 32 patients a drug-relation was suspected. Conclusions Certoparin appears effective and safe for anticoagulation in patients undergoing maintenance hemodialysis.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Oliver Dorsch, Detlef H. Krieter, Horst-Dieter Lemke, Stefan Fischer, Nima Melzer, Christian Sieder, Peter Bramlage, Job Harenberg
URN:urn:nbn:de:bvb:20-opus-124052
Document Type:Journal article
Faculties:Medizinische Fakultät / Medizinische Klinik und Poliklinik I
Language:English
Parent Title (English):BMC Nephrology
Year of Completion:2012
Volume:13
Issue:50
Source:BMC Nephrol. 2012; 13: 50. doi:10.1186/1471-2369-13-50
DOI:https://doi.org/10.1186/1471-2369-13-50
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 616 Krankheiten
Tag:hemodialysis
Release Date:2016/01/13
Licence (German):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung