Usefulness of an implantable loop recorder to detect clinically relevant arrhythmias in patients with advanced fabry cardiomyopathy

Please always quote using this URN: urn:nbn:de:bvb:20-opus-188093
  • Patients with genetic cardiomyopathy that involves myocardial hypertrophy often develop clinically relevant arrhythmias that increase the risk of sudden death. Consequently, guidelines for medical device therapy were established for hypertrophic cardiomyopathy, but not for conditions with only anecdotal evidence of arrhythmias, like Fabry cardiomyopathy. Patients with Fabry cardiomyopathy progressively develop myocardial fibrosis, and sudden cardiac death occurs regularly. Because 24-hour Holier electrocardiograms (ECGs) might not detectPatients with genetic cardiomyopathy that involves myocardial hypertrophy often develop clinically relevant arrhythmias that increase the risk of sudden death. Consequently, guidelines for medical device therapy were established for hypertrophic cardiomyopathy, but not for conditions with only anecdotal evidence of arrhythmias, like Fabry cardiomyopathy. Patients with Fabry cardiomyopathy progressively develop myocardial fibrosis, and sudden cardiac death occurs regularly. Because 24-hour Holier electrocardiograms (ECGs) might not detect clinically important arrhythmias, we tested an implanted loop recorder for continuous heart rhythm surveillance and determined its impact on therapy. This prospective study included 16 patients (12 men) with advanced Fabry cardiomyopathy, relevant hypertrophy, and replacement fibrosis in "loco typico." No patients previously exhibited clinically relevant arrhythmias on Holier ECGs. Patients received an implantable loop recorder and were prospectively followed with telemedicine for a median of 1.2 years (range 0.3 to 2.0 years). The primary end point was a clinically meaningful event, which required a therapy change, captured with the loop recorder. Patients submitted data regularly (14 +/- 11 times per month). During follow-up, 21 events were detected (including 4 asystole, i.e., ECG pauses >= 3 seconds) and 7 bradycardia events; 5 episodes of intermittent atrial fibrillation (>3 minutes) and 5 episodes of ventricular tachycardia (3 sustained and 2 nonsustained). Subsequently, as defined in the primary end point, 15 events leaded to a change of therapy. These patients required therapy with a pacemaker or cardioverter defibrillator implantation and/or anticoagulation therapy for atrial fibrillation. In conclusion, clinically relevant arrhythmias that require further device and/or medical therapy are often missed with Holier ECGs in patients with advanced stage Fabry cardiomyopathy, but they can be detected by telemonitoring with an implantable loop recorder.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Frank Weidemann, Sebastian K. G. Maier, Stefan Störk, Thomas Brunner, Dan Liu, Kai Hu, Nora Seydelmann, Andreas Schneider, Jan Becher, Sima Canan-Kühl, Daniela Blaschke, Bart Bijnens, Georg Ertl, Christoph Wanner, Peter Nordbeck
URN:urn:nbn:de:bvb:20-opus-188093
Document Type:Journal article
Faculties:Medizinische Fakultät / Deutsches Zentrum für Herzinsuffizienz (DZHI)
Language:English
Parent Title (English):The American Journal of Cardiology
Year of Completion:2016
Volume:118
Issue:2
Pagenumber:264-274
Source:The American Journal of Cardiology (2016) 118:2, 264-274. https://doi.org/10.1016/j.amjcard.2016.04.033
DOI:https://doi.org/10.1016/j.amjcard.2016.04.033
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:Cardiovascular magnetic-resonance; Coronary artery disease; Enzyme replacement therapy; Guidelines; Hypertrophic cardiomyopathy; Management; Manifestation; Myocardial fibrosis; Task force; Ventricular-arrhythmias
Release Date:2020/06/18