• search hit 2 of 4
Back to Result List

Rapid deployment valve system shortens operative times for aortic valve replacement through right anterior minithoracotomy

Please always quote using this URN: urn:nbn:de:bvb:20-opus-159439
  • Background: There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT. Methods: Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR betweenBackground: There is growing evidence from the literature that right anterior minithoracotomy aortic valve replacement (RAT-AVR) improves clinical outcome. However, increased cross clamp time is the strongest argument for surgeons not performing RAT-AVR. Rapid deployment aortic valve systems have the potential to decrease cross-clamp time and ease this procedure. We assessed clinical outcome of rapid deployment and conventional valves through RAT. Methods: Sixty-eight patients (mean age 76 ± 6 years, 32% females) underwent RAT-AVR between 9/2013 and 7/2015. According to the valve type implanted the patients were divided into two groups. In 43 patients (R-group; mean age 74.1 ± 6.6 years) a rapid deployment valve system (Edwards Intuity, Edwards Lifesciences Corp; Irvine, Calif) and in 25 patients (C-group; mean age 74.2 ± 6.6 years) a conventional stented biological aortic valve was implanted. Results: Aortic cross-clamp (42.1 ± 12 min vs. 68.3 ± 20.3 min; p < 0.001) and bypass time (80.4 ± 39.3 min vs. 106.6 ± 23.2 min; p = 0.001) were shorter in the rapid deployment group (R-group). We observed no differences in clinical outcome. Postoperative gradients (R-group: max gradient, 14.3 ± 8 mmHg vs. 15.5 ± 5 mmHg (C-group), mean gradient, 9.2 ± 1.7 mmHg (R-group) vs. 9.1 ± 2.3 mmHg (C-group) revealed no differences. However, larger prostheses were implanted in C-group (25 mm; IQR 23–27 mm vs. 23 mm; IQR 21–25; p = 0.009). Conclusions: Our data suggest that the rapid deployment aortic valve system reduced cross clamp and bypass time in patients undergoing RAT-AVR with similar hemodynamics as with larger size stented prosthesis. However, larger studies and long-term follow-up are mandatory to confirm our findings.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Constanze Bening, Khaled Hamouda, Mehmet Oezkur, Christoph Schimmer, Ina Schade, Armin Gorski, Ivan Aleksic, Rainer Leyh
URN:urn:nbn:de:bvb:20-opus-159439
Document Type:Journal article
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Thorax-, Herz- u. Thorakale Gefäßchirurgie
Medizinische Fakultät / Institut für Klinische Epidemiologie und Biometrie
Language:English
Parent Title (English):Journal of Cardiothoracic Surgery
Year of Completion:2017
Volume:12
Issue:27
Source:Journal of Cardiothoracic Surgery (2017) 12:27. DOI: 10.1186/s13019-017-0598-0
DOI:https://doi.org/10.1186/s13019-017-0598-0
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 617 Chirurgie und verwandte medizinische Fachrichtungen
Tag:aortic valve replacement; biological rapid deployment aortic valve; heart valve prosthesis; minimally invasive surgery
Release Date:2018/03/28
Collections:Open-Access-Publikationsfonds / Förderzeitraum 2017
Licence (German):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International