Performance Evaluation of a Preclinical SPECT Scanner with a Collimator Designed for Medium-Sized Animals
Please always quote using this URN: urn:nbn:de:bvb:20-opus-300713
- Background. Equipped with two stationary detectors, a large bore collimator for medium-sized animals has been recently introduced for dedicated preclinical single-photon emission computed tomography (SPECT) imaging. We aimed to evaluate the basic performance of the system using phantoms and healthy rabbits. Methods. A general-purpose medium-sized animal (GP-MSA) collimator with 135 mm bore diameter and thirty-three holes of 2.5 mm diameter was installed on an ultrahigh-resolution scanner equipped with two large stationary detectorsBackground. Equipped with two stationary detectors, a large bore collimator for medium-sized animals has been recently introduced for dedicated preclinical single-photon emission computed tomography (SPECT) imaging. We aimed to evaluate the basic performance of the system using phantoms and healthy rabbits. Methods. A general-purpose medium-sized animal (GP-MSA) collimator with 135 mm bore diameter and thirty-three holes of 2.5 mm diameter was installed on an ultrahigh-resolution scanner equipped with two large stationary detectors (U-SPECT5-E/CT). The sensitivity and uniformity were investigated using a point source and a cylinder phantom containing 99mTc-pertechnetate, respectively. Uniformity (in %) was derived using volumes of interest (VOIs) on images of the cylinder phantom and calculated as , with lower values of % indicating superior performance. The spatial resolution and contrast-to-noise ratios (CNRs) were evaluated with images of a hot-rod Derenzo phantom using different activity concentrations. Feasibility of in vivo SPECT imaging was finally confirmed by rabbit imaging with the most commonly used clinical myocardial perfusion SPECT agent [99mTc]Tc-sestamibi (dynamic acquisition with a scan time of 5 min). Results. In the performance evaluation, a sensitivity of 790 cps/MBq, a spatial resolution with the hot-rod phantom of 2.5 mm, and a uniformity of 39.2% were achieved. The CNRs of the rod size 2.5 mm were 1.37, 1.24, 1.20, and 0.85 for activity concentration of 29.2, 1.0, 0.5, and 0.1 MBq/mL, respectively. Dynamic SPECT imaging in rabbits allowed to visualize most of the thorax and to generate time-activity curves of the left myocardial wall and ventricular cavity. Conclusion. Preclinical U-SPECT5-E/CT equipped with a large bore collimator demonstrated adequate sensitivity and resolution for in vivo rabbit imaging. Along with its unique features of SPECT molecular functional imaging is a superior collimator technology that is applicable to medium-sized animal models and thus may promote translational research for diagnostic purposes and development of novel therapeutics.…
Author: | Yohji Matsusaka, Rudolf A. Werner, Paula Arias-Loza, Naoko Nose, Takanori Sasaki, Xinyu Chen, Constantin Lapa, Takahiro Higuchi |
---|---|
URN: | urn:nbn:de:bvb:20-opus-300713 |
Document Type: | Journal article |
Faculties: | Medizinische Fakultät / Klinik und Poliklinik für Nuklearmedizin |
Language: | English |
Parent Title (English): | Molecular Imaging |
Year of Completion: | 2022 |
Volume: | 2022 |
Article Number: | 9810097 |
Source: | Molecular Imaging 2022, Vol 2022, Article ID 9810097. DOI: 10.1155/2022/9810097 |
DOI: | https://doi.org/10.1155/2022/9810097 |
Dewey Decimal Classification: | 6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit |
Tag: | SPECT Scanner; medium-sized animals; performance |
Release Date: | 2023/04/03 |
Collections: | Open-Access-Publikationsfonds / Förderzeitraum 2022 |