• Treffer 4 von 8
Zurück zur Trefferliste

A surgeon that switched to unrestricted kinematic alignment with manual instruments has a short learning curve and comparable resection accuracy and outcomes to those of an experienced surgeon

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-281842
  • After starting an orthopedic practice, a surgeon with a fellowship in mechanically aligned (MA) TKA initiated this study to characterize their learning curve after they switched to unrestricted kinematic alignment (KA) TKA using manual instruments. Accordingly, the present study determined for the inexperienced (IE) surgeon the number of cases required to achieve consistent femoral resections and operating times, and whether the femoral resection accuracy, patient-reported outcome measures (PROMs), and component alignment were different from anAfter starting an orthopedic practice, a surgeon with a fellowship in mechanically aligned (MA) TKA initiated this study to characterize their learning curve after they switched to unrestricted kinematic alignment (KA) TKA using manual instruments. Accordingly, the present study determined for the inexperienced (IE) surgeon the number of cases required to achieve consistent femoral resections and operating times, and whether the femoral resection accuracy, patient-reported outcome measures (PROMs), and component alignment were different from an experienced (E) surgeon. This prospective cohort study analyzed the IE surgeon's first 30 TKAs, all performed with KA, and 30 consecutive KA TKAs performed by an E surgeon. The resection accuracy or deviation was the calipered thickness of the distal and posterior medial and lateral femoral resections minus the planned resection thickness, which was the thickness of the corresponding condyle of the femoral component, minus 2 mm for cartilage wear, and 1 mm for the kerf of the blade. Independent observers recorded the femoral resection thickness, operative times, PROMs, and alignment. For each femoral resection, the deviation between three groups of patients containing ten consecutive KA TKAs, was either insignificant (p = 0.695 to 1.000) or within the 0.5 mm resolution of the caliper, which indicated no learning curve. More than three groups were needed to determine the learning curve for the operative time; however, the IE surgeon's procedure dropped to 77 min for the last 10 patients, which was 20 min longer than the E surgeon. The resection deviations of the IE and E surgeon were comparable, except for the posterolateral femoral resection, which the IE surgeon under-resected by a mean of −0.8 mm (p < 0.0001). At a mean follow-up of 9 and 17 months, the Forgotten Joint Score, Oxford Knee Score, KOOS, and the alignment of the components and limbs were not different between the IE and E surgeon (p ≥ 0.6994). A surgeon that switches to unrestricted KA with manual instruments can determine their learning curve by computing the deviation of the distal and posterior femoral resections from the planned resection. Based on the present study, an IE surgeon could have resection accuracy, post-operative patient outcomes, and component alignment comparable to an E surgeon.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Alexander J. Nedopil, Anand Dhaliwal, Stephen M. Howell, Maury L. Hull
URN:urn:nbn:de:bvb:20-opus-281842
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Lehrstuhl für Orthopädie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Journal of Personalized Medicine
ISSN:2075-4426
Erscheinungsjahr:2022
Band / Jahrgang:12
Heft / Ausgabe:7
Aufsatznummer:1152
Originalveröffentlichung / Quelle:Journal of Personalized Medicine (2022) 12:7, 1152. https://doi.org/10.3390/jpm12071152
DOI:https://doi.org/10.3390/jpm12071152
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Freie Schlagwort(e):accuracy; efficiency; kinematic alignment; learning curve; total knee arthroplasty
Datum der Freischaltung:05.05.2023
Datum der Erstveröffentlichung:16.07.2022
Lizenz (Deutsch):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International