The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 10 of 466
Back to Result List

Vagus-somatosensorisch evozierte Potentiale (VSEP) – Testung der Reliabilität und Untersuchungen zu alternativen Stimulations- und Ableitbedingungen

Vagus somatosensory evoked potentials – Testing of reliability and investigation of alternative stimulation and recording sites

Please always quote using this URN: urn:nbn:de:bvb:20-opus-187009
  • Die Ableitung Vagus-somatosensibel evozierter Potentiale (VSEP) ist eine vielversprechende, kostengünstige und nicht-invasive Methode zur Frühdiagnostik von Alzheimer-Demenz. In der vorliegenden Arbeit wurde die Retest-Reliabilität der VSEP untersucht. Des Weiteren wurden alternative Stimulationsbedingungen (Stimulation in der Cymba conchae und im anterioren äußeren Gehörgang) und alternative Ableitbedingungen (referentielle Ableitungen mit Elektroden an Mastoid, Spina scapulae, Vertebra prominens und Handrücken) getestet und mit derDie Ableitung Vagus-somatosensibel evozierter Potentiale (VSEP) ist eine vielversprechende, kostengünstige und nicht-invasive Methode zur Frühdiagnostik von Alzheimer-Demenz. In der vorliegenden Arbeit wurde die Retest-Reliabilität der VSEP untersucht. Des Weiteren wurden alternative Stimulationsbedingungen (Stimulation in der Cymba conchae und im anterioren äußeren Gehörgang) und alternative Ableitbedingungen (referentielle Ableitungen mit Elektroden an Mastoid, Spina scapulae, Vertebra prominens und Handrücken) getestet und mit der herkömmlichen Methode verglichen. Die Reliabilitätsuntersuchungen wurden an 24 gesunden Probanden im Abstand von sechs Monaten durchgeführt. Die alternativen Stimulations- und Ableitbedingungen wurden an je zehn bis zwölf Probanden angewandt und die Ergebnisse mit denen von Messungen mit der herkömmlichen Methode verglichen. Es zeigte sich eine besonders gute Reliabilität in den Ableitungen T3/O1 und T4/O2. Außerdem liegen Hinweise darauf vor, dass das Alter der Probanden die Reliabilität beeinflusst. Als beste alternative Ableitposition erwies sich das Mastoid. Die Messungen mit alternativen Stimulationspositionen ergaben stark von der herkömmlichen Methode abweichende Ergebnisse, deren Ursache die vorliegende Studie nicht sicher klären kann.show moreshow less
  • The recording of vagus somatosensory evoked potentials (VSEP) is a promising, cheap and non-invasive method for the early diagnosis of Alzheimer´s disease. The present study examined the retest-reliability of VSEP. Furthermore alternative stimulation sites (stimulation at cymba concha and at the anterior side of the external auditory canal) as well as alternative recording sides (recording electrodes at mastoid, spina scapulae, vertebra prominens and dorsum of the hand) were examined and compared to the standard method. For the reliabilityThe recording of vagus somatosensory evoked potentials (VSEP) is a promising, cheap and non-invasive method for the early diagnosis of Alzheimer´s disease. The present study examined the retest-reliability of VSEP. Furthermore alternative stimulation sites (stimulation at cymba concha and at the anterior side of the external auditory canal) as well as alternative recording sides (recording electrodes at mastoid, spina scapulae, vertebra prominens and dorsum of the hand) were examined and compared to the standard method. For the reliability tests, VSEP-measures were performed on 24 healthy subjects at intervals of at least six months. For the alternative stimulation and recording sites VSEP measures were carried out on ten to twelve subjects for each site and the results were then compared to the ones of measures with the conventional method. The recording positions T3/O1 and T4/O2 showed the highest reliability. Additionally there is evidence for an affection of reliability by the subjects´ age. Among the alternative recording sites, mastoid showed to be the most appropriate one. The VSEP-measures with alternative stimulation sites revealed highly divergent results compared to the results from standard measures. The present study cannot certainly clarify the reasons for these divergences.show moreshow less

Download full text files

Export metadata

Metadaten
Author: Maren Kopetschke
URN:urn:nbn:de:bvb:20-opus-187009
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Psychiatrie, Psychosomatik und Psychotherapie
Referee:Prof. Dr. Martin J. Herrmann, PD Dr. Thomas Polak
Date of final exam:2019/04/11
Language:German
Year of Completion:2019
DOI:https://doi.org/10.25972/OPUS-18700
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 616 Krankheiten
GND Keyword:Vagus; Evoziertes Potenzial; Evoked potential; Alzheimer; Reliabilität
Tag:Vagus-somatosensorisch evozierte Potentiale
Release Date:2019/09/06
Licence (German):License LogoCC BY-SA: Creative-Commons-Lizenz: Namensnennung, Weitergabe unter gleichen Bedingungen 4.0 International