The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 1 of 20
Back to Result List

Vergleichende Analysen zwischen dreidimensionaler und konventioneller Kephalometrie bei Dysgnathiepatienten – Digitale Volumentomographie versus laterales Fernröntgenseitenbild

Comparative analysis between three-dimensional and conventional cephalometry dysgnathic patients – Cone-beam computed tomography vs. lateral radiographs

Please always quote using this URN: urn:nbn:de:bvb:20-opus-51407
  • In der vorliegenden retrospektiven Querschnittstudie wurde untersucht, ob sich zwei- und dreidimensionale Kephalometrie bei Dysgnathiepatienten unterscheidet. Zur Auswertung herangezogen wurden standardisiert aufgenommene Fernröntgenseitenbilder (FRS) und Cone-beam computed tomography (CB-CT)-Scans von 36 Patienten. Alle Patienten wurden in der Universitätsklinik und Poliklink für Mund-, Kiefer- und Plastische Gesichtschirurgie aufgrund ihrer Dysgnathie operativ versorgt. Vor dem Vergleich der konventionellen Schichtaufnahmen und derIn der vorliegenden retrospektiven Querschnittstudie wurde untersucht, ob sich zwei- und dreidimensionale Kephalometrie bei Dysgnathiepatienten unterscheidet. Zur Auswertung herangezogen wurden standardisiert aufgenommene Fernröntgenseitenbilder (FRS) und Cone-beam computed tomography (CB-CT)-Scans von 36 Patienten. Alle Patienten wurden in der Universitätsklinik und Poliklink für Mund-, Kiefer- und Plastische Gesichtschirurgie aufgrund ihrer Dysgnathie operativ versorgt. Vor dem Vergleich der konventionellen Schichtaufnahmen und der korrespondierenden Volumina des gleichen Patienten miteinander, wurde zunächst eine Prüfung der Methode für beide Verfahren vorgenommen. Die Ergebnisse wurden statistisch deskriptiv und mithilfe eines Einstichproben-T-Test sowie eines F-Tests ausgewertet und interpretiert. Als Signifikanzniveau wurde p ≤ 0,05 gewählt. In der Studie konnte gezeigt werden, dass sich Untersucher bei der Auswertung eines dreidimensionalen Bildes häufiger und deutlicher unterscheiden als bei einer vergleichbaren Analyse auf Grundlage eines zweidimensionalen Bildes. Die Standardabweichungen waren für die Auswertungen der Volumina kleiner. Insbesondere die Messung der Unterkieferlänge zeigte bei dreidimensionalen Bildern deutliche Unterschiede zwischen beiden Untersuchern. Die große Mehrzahl der anderen Messwerte zeigten hingegen keine relevanten Unterschiede zwischen den Untersuchern. Die Varianzen der Messungen waren für die 3-D-Kephalometrie in 71% bzw. 79% der Fälle kleiner als in einer vergleichbaren zweidimensionalen FRS-Messung. Es zeigte sich kein Anhalt für Zusammenhänge zwischen der Anzahl der Referenzpunkte, die einer Messung zugrunde liegen und der entsprechenden Varianz des untersuchten Parameters. Beim direkten Vergleich zwischen zwei- und dreidimensionalem Bild wurden bei 66% der paramedianen Parameter, aber nur bei 25% der medianen Variablen gemittelte Differenzen von mehr als einem Millimeter bzw. Grad festgestellt. Es kommt also bei Parametern, die außerhalb der Schädelmedian-Ebene liegen, häufiger zu klinisch relevanten Differenzen zwischen lateralem FRS und CB-CT. Die CB-CT kann zusammen mit der 3D-Kephalometrie bei Patienten mit fazialen Asymmetrien einen Zugewinn an Information gegenüber der konventionellen Schichtaufnahme bedeuten. Hier zeigen sich die Vorteile einer überlagerungsfreien und präzisen Darstellung des Gesichtsschädels klar.show moreshow less
  • The purpose of the present retrospective cross-sectional study was to review if the method of a two-dimensional cephalometric measurement distinguishes significantly from a three-dimensional measurement. For its interpretation standardized cone-beam computed tomographs (CBCT) and lateral radiographs (Ceph) of 36 dysgnatic patients have been used. All tested subjects underwent orthognathic surgeries at the Department of Cranio-Maxillo-Facial Surgery at the University of Würzburg (Bavaria/Germany). Before comparing the test results of the sameThe purpose of the present retrospective cross-sectional study was to review if the method of a two-dimensional cephalometric measurement distinguishes significantly from a three-dimensional measurement. For its interpretation standardized cone-beam computed tomographs (CBCT) and lateral radiographs (Ceph) of 36 dysgnatic patients have been used. All tested subjects underwent orthognathic surgeries at the Department of Cranio-Maxillo-Facial Surgery at the University of Würzburg (Bavaria/Germany). Before comparing the test results of the same test subject (derived by conventional radiographs and CBCT scans) different test methods have been reviewed. The results of the tests have been statistically evaluated and analyzed by an F test together with an T test for unpaired and indepented samples with a significance level of p ≤ 0.05. The study shows that observers disagree significantly more often, obvious and distinct when it comes to three-dimensional measurement of dysgnathic patients compared to a two-dimensional examination (standard deviation for CBCT measurements was significantly smaller). In particular measurement of the length of the mandible shows clearly distinctions between the two tested methods. Whereas the majority of the other measured data does not show notable relevant differences. The variances of the three-dimensional measurements have been in 71% (respectively 79% of the cases) smaller than the two-dimensional cephalometric measurement method. There was no sign for coherence between the number of reference points and the corresponding variances of the examined parameters. In a straight comparison between two-dimensional and three-dimensional images was in 66% of the cases (paramedian parameter) and 25% of the cases (median parameter) an averaged difference of one millimeter or degree. It is safe to say that in terms of parameter outside the skull median there are more often clinical relevant differences between lateral radiograph and the CB-CT method to observe. CB-CT method combined with three-dimensional measurement of dysgnathic patients can gain an information plus towards a conventional lateral method and shows clearly the benefits of an accurate and non-overlapping image of the viscerocranium.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Stefan Hartmann
URN:urn:nbn:de:bvb:20-opus-51407
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie
Date of final exam:2010/09/20
Language:German
Year of Completion:2010
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
GND Keyword:Kraniometrie; Volumentomographie; Fernröntgenseitenbild; Dysgnathie
Tag:Dysgnathie; Fernröntgenseitenbild; Kephalometrie; Kraniometrie; Volumentomographie
CBCT; Cephalometry; lateral radiograph; malocclusion
Release Date:2010/10/01
Advisor:Prof. Dr. Dr. Alexander Kübler
Licence (German):License LogoDeutsches Urheberrecht