• search hit 2 of 11
Back to Result List

Aktive Gefäßverschlusssysteme in der interventionellen Radiologie: Sicherheit und Effektivität des neuartigen Doppelclip-basierten Celt ACD® Systems

Active vascular closure devices in interventional radiology: safety and efficacy of a novel double-clip-based Celt ACD® system

Please always quote using this URN: urn:nbn:de:bvb:20-opus-300986
  • Mit steigender Nachfrage an minimal-invasiven Therapieoptionen wächst auch das Interesse an innovativen Alternativen im Bereich des arteriellen Gefäßverschlusses nach PVI. Ziel der vorliegenden Arbeit war es, die Effektivität und Sicherheit eines neu auf dem Markt befindlichen, Doppelclip-basierten aktiven VVS zu prüfen. Eine hohe technische Erfolgsrate von 98,8 % bei einer geringen Komplikationsrate von 3,6 % wurde verzeichnet. Bei Anwesenheit der Komorbiditäten Dm und CNI 5 zeigte sich eine signifikante Assoziation zu einem vermehrtenMit steigender Nachfrage an minimal-invasiven Therapieoptionen wächst auch das Interesse an innovativen Alternativen im Bereich des arteriellen Gefäßverschlusses nach PVI. Ziel der vorliegenden Arbeit war es, die Effektivität und Sicherheit eines neu auf dem Markt befindlichen, Doppelclip-basierten aktiven VVS zu prüfen. Eine hohe technische Erfolgsrate von 98,8 % bei einer geringen Komplikationsrate von 3,6 % wurde verzeichnet. Bei Anwesenheit der Komorbiditäten Dm und CNI 5 zeigte sich eine signifikante Assoziation zu einem vermehrten Auftreten von Komplikationen. Ein nachgewiesener signifikanter Zusammenhang bestand zudem zwischen einem erhöhten Kalzifikationsgrad der Punktionsstelle bei Vorliegen einer pAVK und eines Dm. Eine erhöhte Gefäßrigidität aufgrund von Komorbiditäten und vaskulären Kalzifikationen, intrinsische Fremdkörperreaktionen, vasoregulatorische Reaktionen oder Produktversagen bieten hypothetische Erklärungsansätze für die einzelnen komplikativen Fälle. Die Nutzung des VVS in spezifischen, bisher nicht beschriebenen Situationen (Unterdimensionierung, Anwendung nach Gefäßpunktionen mit Zugangsschleusen bis 9F, antegrade Punktionsrichtung, anspruchsvolle Eingriffe multimorbider Patienten mit komplexem vaskulärem Status) erwies sich als suffizient. Zur Prävention schwerwiegender Komplikationen während zukünftiger Interventionen wurden die Empfehlung ausgesprochen, eine Durchleuchtungsaufnahme zur Lagekontrolle vor Implantation des proximalen Clips anzufertigen. Eine speziell für Gefäßverschlüsse nach antegrader Punktion konzipierte Zugangsschleuse könnte das Abknicken von Zugangsschleusen bei VVS Applikation verhindern. Zusammenfassend kann das untersuchte aktive VVS mit einzigartigem Wirkmechanismus und spezifischen Design als effektiv und sicher angesehen werden.show moreshow less
  • The need of minimally invasive therapy options is constantly growing and so is the need for alternative options of vascular closure after peripheral vascular interventions. The aim of this thesis was to assess the efficacy and safety of the novel double-clip-based vascular closure device (VCD). The overall technical success rate was 98,8% with an overall low complication rate of 3,6 %. The comorbidities diabetes and chronical kidney disease proof to be significant risk factors for the appearance of complications. There was a significantThe need of minimally invasive therapy options is constantly growing and so is the need for alternative options of vascular closure after peripheral vascular interventions. The aim of this thesis was to assess the efficacy and safety of the novel double-clip-based vascular closure device (VCD). The overall technical success rate was 98,8% with an overall low complication rate of 3,6 %. The comorbidities diabetes and chronical kidney disease proof to be significant risk factors for the appearance of complications. There was a significant association between an increased degree of calcification of the puncture site in the presence of peripheral artery disease and diabetes. Increased vascular rigidity due to comorbidities and vascular calcifications, intrinsic foreign body reactions, vasoregulatory reactions, or product failure offer hypothetical explanations for the individual complicative cases. The use of the VCD during previously not analyzed settings e.g. undersizing in relation to the introducer sheath, accesses of up to 8 or 9 Fr with a 7 Fr device, antegrade puncture and challenging patient collective, proofed to be sufficient. To prevent major complications during future application, it is recommended to check the position of the VCD fluoroscopically, before implantation of the proximal wing. A specially designed introducer sheath may be helpful to prevent kinking of the introducer sheath during VCD application in antegrad punctures. In conclusion, the novel VCD proved to be effective and safe.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Anjana HeuerGND
URN:urn:nbn:de:bvb:20-opus-300986
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Medizinische Fakultät
Faculties:Medizinische Fakultät / Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik)
Referee:Prof. Dr. Ralph Kickuth, Prof. Dr. Wolfram Voelker
Date of final exam:2022/12/20
Language:German
Year of Completion:2023
DOI:https://doi.org/10.25972/OPUS-30098
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 617 Chirurgie und verwandte medizinische Fachrichtungen
GND Keyword:Gefäßverschluss
Tag:Vascular closure devices; access site complications; antegrade puncture; femoral access
Release Date:2023/01/31
Licence (German):License LogoDeutsches Urheberrecht mit Print on Demand