The search result changed since you submitted your search request. Documents might be displayed in a different sort order.
  • search hit 15 of 100
Back to Result List

Qualitative Charakterisierung polydisperser Macrogole sowie strukturell verwandter Hilfsstoffe mittels HPLC-CAD

Qualitative characterization of polydisperse macrogols and related excipients with HPLC-CAD

Please always quote using this URN: urn:nbn:de:bvb:20-opus-179274
  • Der Gruppe der Macrogole sowie den darauf basierenden Abkömmlingen, den Macrogolfettalkoholethern, Macrogolfettsäureestern und Polysorbaten, kommt in der modernen Galenik eine wichtige Rolle zu. Dienten sie vormals nur als gewöhnliche Emulgatoren, so finden sie heutzutage vor allem im Bereich der gezielten Wirkstofffreisetzung, der Erhöhung der Bioverfügbarkeit sowie als Löslichkeitsvermittler komplexer Systeme Anwendung. Diese vielschichtigen Anwendungsgebiete erfordern, auch aufgrund der polydispersen Strukturen der Macrogole, eineDer Gruppe der Macrogole sowie den darauf basierenden Abkömmlingen, den Macrogolfettalkoholethern, Macrogolfettsäureestern und Polysorbaten, kommt in der modernen Galenik eine wichtige Rolle zu. Dienten sie vormals nur als gewöhnliche Emulgatoren, so finden sie heutzutage vor allem im Bereich der gezielten Wirkstofffreisetzung, der Erhöhung der Bioverfügbarkeit sowie als Löslichkeitsvermittler komplexer Systeme Anwendung. Diese vielschichtigen Anwendungsgebiete erfordern, auch aufgrund der polydispersen Strukturen der Macrogole, eine reproduzierbare und aussagekräftige Analytik. Das Europäische Arzneibuch (Ph. Eur.) bietet zur Charakterisierung der Hilfsstoffe eine Handvoll Messgrößen, die sog. Fettkennzahlen, die eine Größenordnung vorhandener funktioneller Gruppen liefern. Zu diesen gehören Werte wie Hydroxylzahl, Iodzahl, Peroxidzahl oder Säurezahl. Diese bieten zwar einen Überblick über den Größenbereich der mittleren Kettenlängen oder einen möglichen Abbau der Strukturen, beispielsweise durch Autoxidation, jedoch geben sie keine Auskunft über die Polymerverteilung. Insbesondere diese kann jedoch, je nach Herstellungsweise, stark variieren. Außerdem ist die Methodik der Fettkennzahlenbestimmungen aufgrund der strikten Reaktionsabläufe und zahlreicher Reaktionsschritte einerseits sehr zeitaufwändig und andererseits anfällig für Fehler. Die HPLC hat, insbesondere aufgrund der Automation, bereits seit Jahren den Status des Goldstandards in der pharmazeutischen Analytik inne. Gekoppelt mit der UV-Detektion bietet sie für zahlreiche Wirkstoffe die Möglichkeit zur schnellen, einfachen und robusten Analyse. Im Bereich der Hilfsstoffe verbreitet sich die HPLC-Analytik langsamer, da viele Hilfsstoffe keinen Chromophor aufweisen. Eine Anwendung der hochsensitiven Massenspektrometrie wäre zwar zur Detektion geeignet, würde sich für die Routineanwendung jedoch als zu komplex und kostenintensiv gestalten. Doch mit der Entwicklung der Aerosol-basierten Detektoren wie dem ELSD (evaporative light scattering detector), dem CAD (charged aerosol detector) und dem NQADTM (nano quantity aerosol detector) wurde auch für nicht-chromophore Substanzen ein Einsatz der HPLC möglich. Die vorliegende Arbeit befasste sich mit der Entwicklung einer HPLC-CAD-Methode, die eine möglichst große Bandbreite der Macrogole und der darauf basierenden Hilfsstoffe erfassen kann. Die Trennung erfolgte an einer C18-Trennsäule. Es wurde eine Gradienten-Methode entwickelt, die aus mehreren linearen Gradientenstufen zusammengesetzt wurde, um verschiedene Kettenlängen der Polymere besser voneinander zu trennen. Als mobile Phasen dienten Wasser und Acetonitril, denen jeweils 0.1 % Ameisensäure zugesetzt wurden. Es konnten Macrogole im Bereich PEG 300 bis PEG 3000 mit akzeptabler Auflösung aufgetrennt werden. Diese Ergebnisse wurden für PEG 300 – 1500 mittels Massenspektrometrie verifiziert. Es konnten fünf gesättigte und zwei ungesättigte Fettsäuren, sowie zwei Fettalkohole verschiedener Kettenlängen voneinander getrennt werden. Es wurden 13 Macrogol-basierte Hilfsstoffe mit der entwickelten Methode untersucht und erfolgreich getrennt. Die Macrogolfettalkoholether, -stearate und Polysorbate wurden insoweit aufgetrennt, dass die Polymerverteilung beobachtet werden konnte. Freie PEGs in den Hilfsstoffen wurden getrennt und identifiziert. Anhand dieser konnten unterschiedliche Herstellungsweisen zugeordnet werden. Abhängig von der mittleren Kettenlänge der verarbeiteten PEGs konnten teilweise die freien Fettsäuren bzw. -alkohole von den Estern bzw. Ethern getrennt und identifiziert werden. Im Bereich der kürzeren mittleren Kettenlängen wurden die freien Fettsäuren und -alkohole von den Estern und Ethern überlagert. Macrogolglycerolhydroxystearat (Cremophor® RH40) wurde in seine Komponenten aufgetrennt, mit Ausnahme der linearen Monoester, die mit den freien PEGs partiell koeluierten und die Glyceroltriester, die Größenausschlusseffekte zeigten. Die Methode wurde für Stabilitätsuntersuchungen der ungesättigten Fettsäuren, Öl- und Linolsäure, eingesetzt. Hierzu wurden diese Säuren in Lösung chemisch (Wasserstoffperoxid) und thermisch (60 °C) gestresst und in bestimmten Zeitabständen analysiert. Es zeigte sich ein zeit- und temperaturabhängiger Abbau. Die teilweise Zuordnung der Abbauprodukte erfolgte durch Bestimmung des m/z mittels Massenspektrometrie. Die Methode war geeignet, um das Ausmaß eines oxidativen Abbaus von der Hauptsubstanz zu trennen und strukturell einzuordnen. Generell bietet die Methode eine gute Basis, die eine Vielzahl an Substanzgruppen erfassen und charakterisieren kann. Sie bietet eine Ergänzung der Fettkennzahlen, die einen verringerten Arbeitsaufwand mit sich bringt. Für spezifischere Betrachtungen (Langzeitstabilität, verwandte Substanzgruppen) stellt sie einen guten Ausgangspunkt dar.show moreshow less
  • The class of macrogols and macrogol-based excipients, i.e. macrogol fatty alcohol ethers, macrogol fatty acid esters, and polysorbates, plays an important role in modern galenic formulations. Formerly used as simple emulsifiers, they are nowadays utilized in fields such as targeted drug release to increase bioavailability, and as solubilizers for complex systems. For these multifaceted applications, and regarding the polydisperse structures of the macrogols, a reproducible and significant analytical procedure is required. For theThe class of macrogols and macrogol-based excipients, i.e. macrogol fatty alcohol ethers, macrogol fatty acid esters, and polysorbates, plays an important role in modern galenic formulations. Formerly used as simple emulsifiers, they are nowadays utilized in fields such as targeted drug release to increase bioavailability, and as solubilizers for complex systems. For these multifaceted applications, and regarding the polydisperse structures of the macrogols, a reproducible and significant analytical procedure is required. For the characterization of excipients, the European Pharmacopoeia (Ph. Eur.) provides some compendial protocols which are able to describe the number of functional groups present in the substance. Some examples of these bulk parameters are the hydroxyl value, the iodine value, the peroxide value, or the acid value. Thus, these bulk parameters allow an overview of the average molar weight or possible degradation processes (e.g. autoxidation), but they provide no further information about the polymeric distribution which can heavily depend on the manufacturing process. Furthermore, bulk parameter investigations are very time-consuming and prone to errors due to their stringent reaction processes and numerous reaction steps. Since several years, the HPLC has been the gold standard of pharmaceutical analytics particularly due to the fact of automation. Coupled to UV detection, it offers the opportunity for a quick, easy, and robust analysis for many drugs. In the field of excipients, the development progress of HPLC-analysis is much slower due to the fact that most excipients lack a UV-chromophore. The application of the highly sensitive mass spectrometry would be eligible for detection but is rather complex and expensive. However, the development of the aerosol-based detectors such as the ELSD (evaporative light scattering detection), the CAD (charged aerosol detection), and the NQADTM (nano quantity aerosol detection) enables the application of HPLC for analyzing non-chromophoric substances. This work aimed to develop a generic HPLC-CAD method to analyze a wide range of macrogols and macrogol-based excipients. The separation was performed on a C18-column. A gradient method was developed based upon several linear gradient steps in order to be able to separate the different chain lengths. The mobile phases were water and acetonitrile, respectively, to which 0.1% formic acid was added. Macrogols in the average size range of PEG 300 to PEG 3000 were separated with acceptable resolution. The separation results were verified by mass spectrometry for PEG 300 - 1500. Five saturated and two non-saturated fatty acids, as well as two fatty alcohols of different chain lengths were successfully separated. 13 macrogol-based excipients were analyzed with the developed method and separated successfully. The macrogol fatty alcohol ethers, macrogol stearates, and polysorbates were separated to sufficient extent to analyze the polymeric distribution. The free PEGs in the excipients were separated and identified. Based on these free PEGs, different manufactural processes could be determined. Depending on the average chain lengths of the processed PEGs, the free fatty acids or alcohols could be identified and separated from the esters or ethers, respectively. For the smaller average chain lengths, the free fatty acids and alcohols coeluted with the esters and ethers. Macrogol glycerol hydroxy stearate (Cremophor® RH40) was separated into its components except for the linear monoesters which partially coeluted with the free PEGs, and the glycerol triesters which showed effects of size exclusion. The developed method was also used for stability tests of the non-saturated fatty acids, i.e. oleic and linoleic acid. Here, the fatty acid solutions were chemically (hydrogen peroxide) and thermally (60 °C) stressed and analyzed after different time spans. A time and temperature dependent degradation was observed. An assignment of some degradation products was performed by determining the m/z values with mass spectrometry. The method proved to be capable of separating the degradation products of the main substance and allows to estimate the dimension of degradational processes and partly identify the structures of the degradational products. In general, the provided method offers a good basis for analyzing and characterizing a wide field of substance classes. It provides an extension of bulk parameters (e.g. hydroxyl value) with a reduction of analytical effort. It offers a good starting point for more specific observations such as long-term stability or other related substance classes.show moreshow less

Download full text files

Export metadata

Metadaten
Author: Christiane Theiss
URN:urn:nbn:de:bvb:20-opus-179274
Document Type:Doctoral Thesis
Granting Institution:Universität Würzburg, Fakultät für Chemie und Pharmazie
Faculties:Fakultät für Chemie und Pharmazie / Institut für Pharmazie und Lebensmittelchemie
Referee:Prof. Dr. Ulrike Holzgrabe
Date of final exam:2019/04/12
Language:German
Year of Completion:2019
DOI:https://doi.org/10.25972/OPUS-17927
Dewey Decimal Classification:5 Naturwissenschaften und Mathematik / 54 Chemie / 543 Analytische Chemie
GND Keyword:HPLC; Macrogol; Pharmazeutischer Hilfsstoff
Tag:Chromatographie; Hilfsstoffanalytik; Macrogole; Pharmacy
Charged Aerosol Detection; Excipients
Release Date:2019/04/23
Licence (German):License LogoDeutsches Urheberrecht mit Print on Demand