Quantitative Feuchtesensorik mit lumineszierenden Ln-MOFs und Polymer-MOF-Matrix-Membranen
Quantitative humidity sensning with luminescent Ln-MOFs and Polymer-MOF-Matrix-Membranes
Please always quote using this URN: urn:nbn:de:bvb:20-opus-173190
- In der vorliegenden Arbeit werden die Sensorikeigenschaften der lumineszierenden metallorganischen Gerüstverbindungen (metal-organic frameworks, MOFs) ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), ■(3@∞)[Sr0.90Eu0.10(Im)2] (2), ■(3@∞)[Tb(Im)3] (3), ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) und ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5), sowohl in Form der Bulksubstanzen als auch in Form von mixed-matrix membranes (MMMs) gegenüber den Analyten Wasser, Methanol, Ethanol und Isopropanol untersucht und mittels kinetischer Betrachtungen quantitativIn der vorliegenden Arbeit werden die Sensorikeigenschaften der lumineszierenden metallorganischen Gerüstverbindungen (metal-organic frameworks, MOFs) ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), ■(3@∞)[Sr0.90Eu0.10(Im)2] (2), ■(3@∞)[Tb(Im)3] (3), ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) und ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5), sowohl in Form der Bulksubstanzen als auch in Form von mixed-matrix membranes (MMMs) gegenüber den Analyten Wasser, Methanol, Ethanol und Isopropanol untersucht und mittels kinetischer Betrachtungen quantitativ beschrieben. Hierfür wurde ein Versuchsaufbau konstruiert, der den Anforderungen einer quantitativen Erfassung der Sensorikeigenschaften genügt und einflussgebende externe und interne Parameter, wie die Konzentration des Analyten, Temperatur, Druck, Probenmenge und Probenoberfläche standardisiert, um eine möglichst genaue Erfassung der auftretenden Veränderung der Lumineszenzintensität zu ermöglichen. Zusätzlich wurde eine mathematische Betrachtung genutzt, um die Ergebnisse der Experimente zu interpretieren und in einen Gesamtkontext zu setzen. Für jedes der fünf Modellsysteme wurde je eine Messreihe gegen ein breites Spektrum an relativen Feuchten (Wasser als Analyt) bei 25 °C durchgeführt. Der in allen Fällen auftretende Lumineszenzverlust ließ sich jeweils mittels einer Exponentialfunktion beschreiben und zur Bestimmung der konzentrationsabhängigen Reaktionskonstanten sowie der Halbwertszeiten nutzen. Die gewonnenen Informationen wurden verwendet, um die Reaktionskonstanten und die Schwellenwerte der Sensorik der jeweiligen Systeme zu bestimmten. In weiteren Versuchsreihen wurde der Messaufbau genutzt und der Einfluss der Alkohole Methanol, Ethanol und Isopropanol auf die Lumineszenz der MOFs ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) und ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5) bei verschie-denen Konzentrationen in der Gasphase und bei unterschiedlichen Temperaturen untersucht, quantitativ bestimmt und gemäß der vorangegangen Messreihen für Feuchte beschrieben. Zusätzlich wurde die Veränderung des Lumineszenzmusters der MOFs ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) und ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5) untersucht. Die Möglichkeiten der Prozessierung von ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), und ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) wurden im Hinblick auf eine praktische Anwendung im Bereich der Sensorik hin untersucht. Hierfür wurden die jeweiligen Bulksubstanzen via Dropcoating in die drei Polymere Polystyrol (PS), Polyvinychlorid (PVC) und Polymethylpenten (TPX) eingebettet. Die so dargestellten MMMs wurden auf ihre Sensorikeigenschaften hin untersucht und der Lumineszenzverlust wurde quantitativ beschrieben. Des Weiteren wurde die korrespondierende Bulksubstanz, in Bezug auf die (konzentrationsabhängigen) Reaktionskonstanten und Halbwertszeiten, mit den MMMs verglichen. Im Rahmen einer Kooperation mit der Arbeitsgruppe von Prof. Dr. Janiak der Heinrich-Heine-Universität Düsseldorf wurden die MOFs ■(3@∞)[Ba0.98Eu0.02(Im)2] (1) und ■(3@∞)[Sr0.90Eu0.10(Im)2] (2) in Polysulfon (PSF) eingebettet und ebenfalls auf ihre Fähigkeit zur Feuchtesensorik hin untersucht. Im Rahmen der vorliegenden Arbeit war es erstmals möglich, die Sensoreigenschaften der genutzten MOFs und CPs (1 - 5) quantitativ zu erfassen und mathematisch zu beschreiben. Ebenso konnte das entwickelte Sensorikkonzept erfolgreich auf die Erfassung von verschiedenen Alkoholen in der Gasphase übertragen werden (für System 1, 4 und 5). Anschließend war es möglich, die genutzten Modellsysteme 1, 2 und 4 unter dem Erhalt der Lumineszenzeigenschaft in verschiedene Polymere einzubetten und deren Eigenschaften zur Feuchtesensorik ebenfalls quantitativ zu erfassen und mathematisch zu beschreiben. Im letzten Abschnitt der Arbeit wurden die beiden porösen ZIFs (zeolitic imidazolate frameworks) Na-Rho-ZMOF (6) und Zn(nmIm)2 (7) mit einer Terbiumnitratlösung behandelt, um durch die Füllung der Kavitäten die Lumineszenzeigenschaft der Terbiumionen in das ZIF zu implementieren. Der Grad und die Qualität der Befüllung wurden anschließend analytisch auf Lumineszenzeigenschaften hin untersucht. Hierbei konnte die Befüllung von Na-Rho-ZMOF (6) erfolgreich nachgewiesen werden, während es bei Zn(nmIm)2 (7) nicht zu einer Befüllung des Porensystems kam.…
- In the present work, the sensor properties of luminescent metal-organic frameworks (MOFs) ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), ■(3@∞)[Sr0.90Eu0.10(Im)2] (2), ■(3@∞)[Tb(Im)3] (3), ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4), and ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5) were investigated and quantitatively described. Therefore, bulk substances and MMMs (mixed-matrix membranes) were generated and tested against different analytes like water (relative humidity) and alcohols like, methanol, ethanol and isopropanol. For this purpose, a specialIn the present work, the sensor properties of luminescent metal-organic frameworks (MOFs) ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), ■(3@∞)[Sr0.90Eu0.10(Im)2] (2), ■(3@∞)[Tb(Im)3] (3), ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4), and ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5) were investigated and quantitatively described. Therefore, bulk substances and MMMs (mixed-matrix membranes) were generated and tested against different analytes like water (relative humidity) and alcohols like, methanol, ethanol and isopropanol. For this purpose, a special experimental setup was constructed, which meets the requirements of a quantitative detection of the sensor properties and influential environmental parameters, such as the concentration of the analyte (e.g. in the form of relative humidity of the atmosphere), temperature, pressure, sample mass and sample surface. This standardized method allowed a precise determination of the occurring luminescence changes. In addition, a mathematical methodology was used to interpret the results of the experiments and place them in an overall context. For each of the five model systems, a series of measurements were carried out against a wide range of relative humidity at 25 °C. In all cases the occurring "turn-off"-effect could be described for each experiment with an exponential function and used to determine the concentration-dependent reaction constants and the half-lifes. The obtained information was used to determine the reaction constants and the thresholds of the sensor properties of the respective systems. In a further series of experiments, the influence of the alcohols methanol, ethanol, and isopropanol onto the luminescence of the MOFs ■(3@∞)[Ba0.98Eu0.02(Im)2] (1), ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4), and ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5) at various concentrations and temperatures, was quantitatively determined and described mathematically. The relevant properties, such as concentration-dependent reaction constants and half-lifes, were determined. In addition, changes in the luminescence pattern of the MOFs were observed, studied, and described for ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) and ■(2@∞)[Eu2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (5). To enable a real application, the possibilities of processing ■(3@∞)[Ba0.98Eu0.02(Im)2] (1) and ■(2@∞)[Tb2Cl6(4,4‘-bipy)3]•2(4,4‘-bipy) (4) were investigated. For this purpose, the respective bulk substances were embedded in the three polymers polystyrene (PS), polyvinyl chloride (PVC), and polymethylpentene (TPX) via dropcoating. The MMMs were tested for their ability of sensing humidity. The "turn-off"-effect was quantitatively described and analyzed. The corresponding bulk substance was set in relation to point out the occurring changes in stability (concentration-dependent reaction constants and half-lifes). Within a cooperation with the working group Prof. Janiak of the Heinrich Heine University, the MOFs ■(3@∞)[Ba0.98Eu0.02(Im)2] (1) and ■(3@∞)[Sr0.90Eu0.10(Im)2] (2) were embedded into polysulfone (PSF) and also tested for their ability to sense humidity. In this work it was possible to quantify and mathematically describe the sensor properties of the MOFs and CPs used (1 - 5) for the first time. The developed sensing concept was successfully transferred to detect various alcohols in the gas phase (for systems 1, 4, and 5). Subsequently, it was possible to embed the model systems (1, 2, and 4) used in different polymers, while obtaining the luminescence property. Subsequnt, it was possible to record quantitatively and describe mathematically their properties for humidity sensing. In the last part of the work, the two porous ZIFs (zeolitic imidazolate frameworks) Na-Rho-ZMOF (6) and Zn(nmIm)2 (7) were mixed with a terbium nitrate solution to implement the luminescence properties into the ZIFs by filling the cavities. The degree and the quality of the filling were then checked by a number of analytical methods and the luminescence properties were investigated. The filling of the pore system was detected successfully for Na-Rho-ZMOF (6). For Zn(nmIm)2 (7) no evidence of pore filling was found.…
Author: | Johannes Maria Stangl |
---|---|
URN: | urn:nbn:de:bvb:20-opus-173190 |
Document Type: | Doctoral Thesis |
Granting Institution: | Universität Würzburg, Fakultät für Chemie und Pharmazie |
Faculties: | Fakultät für Chemie und Pharmazie / Institut für Anorganische Chemie |
Referee: | Prof. Dr. Klaus Müller-Buschbaum, Prof. Dr. Maik Finze |
Date of final exam: | 2018/11/27 |
Language: | German |
Year of Completion: | 2018 |
Dewey Decimal Classification: | 5 Naturwissenschaften und Mathematik / 54 Chemie / 546 Anorganische Chemie |
Tag: | Lumineszenz; MOFs; Sensorik |
Release Date: | 2018/12/07 |
Licence (German): | CC BY-SA: Creative-Commons-Lizenz: Namensnennung, Weitergabe unter gleichen Bedingungen 4.0 International |