• Treffer 1 von 2
Zurück zur Trefferliste

Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-159668
  • Introduction The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. Material and methods In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novelIntroduction The goals of successful bi-compartmental knee arthroplasty are to achieve correct fit and positioning of the implant, while appropriately correcting the mechanical alignment of the leg after surgery. As these requirements are not always reliably fulfilled using off-the-shelf implant systems, newer approaches for bi-compartmental resurfacing have been explored. Material and methods In this article we report the radiographic results of 30 patients with anteromedial osteoarthritis (OA) who were treated with a novel patient-specific fixed-bearing bi-compartmental knee resurfacing system using custom-made implants and instruments. Utilizing standardized pre- and postoperative radiographic analyses (based on anterior-posterior and lateral, anterior-posterior weight-bearing full-length radiographs, patella skyline views and preoperative computed tomography (CT) scanning) implant fit and positioning as well as correction of the mechanical axis (hip-knee-ankle angle, HKA) were determined. Results On average, HKA was corrected from 173.4 ±3.47° preoperatively to 179.4 ±2.85° postoperatively. The coronal femoro-tibial angle was corrected on average 5.61°. The preoperative tibial slope measured on lateral views was 6.38 ±2.4°, while the average slope in the CT-based planning protocol (iView) was 6.14 ±2.40°. Postoperative lateral tibial slope was determined to be 5.77 ±1.97°. The thickness of the posterior femoral cuts was measured intraoperatively and, in all cases, corresponded well to the targeted thickness of the cuts provided by the iView. The joint line was preserved in all cases and the average Insall-Salvati index was 1.078 ±0.11 pre- and 1.072 ±0.11 postoperatively. The fit of the implant components measured by over- or underhang was excellent throughout (< 1.01 mm). Conclusions Custom-made bicompartmental knee arthroplasty can ensure optimized fitting and positioning of the implant with restoration of the leg axis. These implants could be considered as an alternative primary solution for knee surgeons treating bi-compartmental disease.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Jörg Arnholdt, Yama Kamawal, Boris Michael Holzapfel, Axel Ripp, Maximilian Rudert, Andre Friedrich Steinert
URN:urn:nbn:de:bvb:20-opus-159668
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Lehrstuhl für Orthopädie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Archives of Medical Science
Erscheinungsjahr:2018
Band / Jahrgang:14
Heft / Ausgabe:6
Seitenangabe:1424-1431
Originalveröffentlichung / Quelle:Archives of Medical Science (2018) 14, 6: 1424–1431. DOI: https://doi.org/10.5114/aoms.2018.79007
DOI:https://doi.org/10.5114/aoms.2018.79007
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 617 Chirurgie und verwandte medizinische Fachrichtungen
Freie Schlagwort(e):bi-compartmental; bi-compartmental knee arthoplasty; implant fit; implant positioning; knee alignment; knee arthroplasty; knee osteoarthritis; patient-specific
Datum der Freischaltung:29.03.2018
Sammlungen:Open-Access-Publikationsfonds / Förderzeitraum 2017
Lizenz (Deutsch):License LogoCC BY-NC-SA: Creative-Commons-Lizenz: Namensnennung, Nicht kommerziell, Weitergabe unter gleichen Bedingungen