004 Datenverarbeitung; Informatik
Filtern
Volltext vorhanden
- ja (1)
Gehört zur Bibliographie
- ja (1)
Erscheinungsjahr
- 2022 (1) (entfernen)
Dokumenttyp
Sprache
- Englisch (1)
Institut
This document presents a networking latency measurement setup that focuses on affordability and universal applicability, and can provide sub-microsecond accuracy. It explains the prerequisites, hardware choices, and considerations to respect during measurement. In addition, it discusses the necessity for exhaustive latency measurements when dealing with high availability and low latency requirements. Preliminary results show that the accuracy is within ±0.02 μs when used with the Intel I350-T2 network adapter.