@article{JordanJovicGilbertetal.2020, author = {Jordan, Martin C. and Jovic, Sebastian and Gilbert, Fabian and Kunz, Andreas and Ertl, Maximilian and Strobl, Ute and Jakubietz, Rafael G. and Jakubietz, Michael G. and Meffert, Rainer H. and Fuchs, Konrad F.}, title = {Qualit{\"a}tssteigerung der Abrechnungspr{\"u}fung durch Smartphone-basierte Fotodokumentation in der Unfall-, Hand-, und Plastischen Chirurgie}, series = {Der Unfallchirurg}, volume = {124}, journal = {Der Unfallchirurg}, issn = {0177-5537}, doi = {10.1007/s00113-020-00866-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-232415}, pages = {366-372}, year = {2020}, abstract = {Hintergrund Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungspr{\"u}fung durch den Medizinischen Dienst der Krankenkassen (MDK) hat. Fragestellung Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erl{\"o}srelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern? Material und Methoden Ausstattung der Mitarbeiter mit digitalen Endger{\"a}ten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungspr{\"u}fung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erl{\"o}sver{\"a}nderung bewirkt hat. Ergebnisse Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 F{\"a}llen (7,2 \%) zur Best{\"a}tigung eines Operationen- und Prozedurenschl{\"u}ssels (OPS) (n = 5; 1,3 \%), einer Hauptdiagnose (n = 10; 2,7 \%), einer Nebendiagnose (n = 3; 0,8 \%) oder der Krankenhausverweildauer (n = 9; 2,4 \%). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erl{\"o}ssteigerung von 2119 €. Inklusive Aufwandpauschale f{\"u}r die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt. Diskussion Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualit{\"a}t der Dokumentation verbessern und Erl{\"o}seinbußen bei der Abrechnungspr{\"u}fung verhindern. Die Implementierung digitaler Endger{\"a}te mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.}, language = {de} } @article{FuchsHeiligMcDonoghetal.2020, author = {Fuchs, Konrad F. and Heilig, Philipp and McDonogh, Miriam and Boelch, Sebastian and Gbureck, Uwe and Meffert, Rainer H. and Hoelscher-Doht, Stefanie and Jordan, Martin C.}, title = {Cement-augmented screw fixation for calcaneal fracture treatment: a biomechanical study comparing two injectable bone substitutes}, series = {Journal of Orthopaedic Surgery and Research}, volume = {15}, journal = {Journal of Orthopaedic Surgery and Research}, doi = {10.1186/s13018-020-02009-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230336}, year = {2020}, abstract = {Background The role of cement-augmented screw fixation for calcaneal fracture treatment remains unclear. Therefore, this study was performed to biomechanically analyze screw osteosynthesis by reinforcement with either a calcium phosphate (CP)-based or polymethylmethacrylate (PMMA)-based injectable bone cement. Methods A calcaneal fracture (Sanders type IIA) including a central cancellous bone defect was generated in 27 synthetic bones, and the specimens were assigned to 3 groups. The first group was fixed with four screws (3.5 mm and 6.5 mm), the second group with screws and CP-based cement (Graftys (R) QuickSet; Graftys, Aix-en-Provence, France), and the third group with screws and PMMA-based cement (Traumacem (TM) V+; DePuy Synthes, Warsaw, IN, USA). Biomechanical testing was conducted to analyze peak-to-peak displacement, total displacement, and stiffness in following a standardized protocol. Results The peak-to-peak displacement under a 200-N load was not significantly different among the groups; however, peak-to-peak displacement under a 600- and 1000-N load as well as total displacement exhibited better stability in PMMA-augmented screw osteosynthesis compared to screw fixation without augmentation. The stiffness of the construct was increased by both CP- and PMMA-based cements. Conclusion Addition of an injectable bone cement to screw osteosynthesis is able to increase fixation strength in a biomechanical calcaneal fracture model with synthetic bones. In such cases, PMMA-based cements are more effective than CP-based cements because of their inherently higher compressive strength. However, whether this high strength is required in the clinical setting for early weight-bearing remains controversial, and the non-degradable properties of PMMA might cause difficulties during subsequent interventions in younger patients.}, language = {en} }