@article{HartrampfKrebsPeteretal.2022, author = {Hartrampf, Philipp E. and Krebs, Markus and Peter, Lea and Heinrich, Marieke and Ruffing, Julia and Kalogirou, Charis and Weinke, Maximilian and Brumberg, Joachim and K{\"u}bler, Hubert and Buck, Andreas K. and Werner, Rudolf A. and Seitz, Anna Katharina}, title = {Reduced segmentation of lesions is comparable to whole-body segmentation for response assessment by PSMA PET/CT: initial experience with the keyhole approach}, series = {Biology}, volume = {11}, journal = {Biology}, number = {5}, issn = {2079-7737}, doi = {10.3390/biology11050660}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-271191}, year = {2022}, abstract = {Simple Summary The calculation of PSMA-positive tumor volume (PSMA-TV) of the whole body from PSMA PET scans for response evaluation remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative tumor lesions. Changes in the whole-body PSMA-TV of 65 patients were comparable to the changes in PSMA-TV after including only the ten largest lesions. Moreover, changes in PSMA-TV correlated well with changes in PSA levels, as did the changes in PSMA-TV with the reduced number of lesions. We conclude that a response assessment using PSMA-TV with a reduced number of lesions is feasible and could lead to a simplified process for evaluating PSMA PET/CT. Abstract (1) Background: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET)-derived parameters, such as the commonly used standardized uptake value (SUV) and PSMA-positive tumor volume (PSMA-TV), have been proposed for response assessment in metastatic prostate cancer (PCa) patients. However, the calculation of whole-body PSMA-TV remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative lesions. (2) Methods: Sixty-five patients classified into different disease stages were assessed by PSMA PET/CT for staging and restaging after therapy. Whole-body PSMA-TV and whole-body SUV\(_{max}\) were calculated. We then repeated this calculation only including the five or ten hottest or largest lesions. The corresponding serum levels of prostate-specific antigen (PSA) were also determined. The derived delta between baseline and follow-up values provided the following parameters: ΔSUV\(_{maxall}\), ΔSUV\(_{max10}\), ΔSUV\(_{max5}\), ΔPSMA-TV\(_{all}\), ΔPSMA-TV\(_{10}\), ΔPSMA-TV\(_{5}\), ΔPSA. Finally, we compared the findings from our whole-body segmentation with the results from our keyhole approach (focusing on a limited number of lesions) and correlated all values with the biochemical response (ΔPSA). (3) Results: Among patients with metastatic hormone-sensitive PCa (mHSPC), none showed a relevant deviation for ΔSUV\(_{max10}\)/ΔSUV\(_{max5}\) or ΔPSMA-TV\(_{10}\)/ΔPSMA-TV\(_{5}\) compared to ΔSUV\(_{maxall}\) and ΔPSMA-TV\(_{all}\). For patients treated with taxanes, up to 6/21 (28.6\%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only up to 2/21 (9.5\%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). For patients treated with radioligand therapy (RLT), up to 5/28 (17.9\%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only 1/28 (3.6\%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). The highest correlations with ΔPSA were found for ΔPSMA-TV\(_{all}\) (r ≥ 0.59, p ≤ 0.01), followed by ΔPSMA-TV\(_{10}\) (r ≥ 0.57, p ≤ 0.01) and ΔPSMA-TV\(_{5}\) (r ≥ 0.53, p ≤ 0.02) in all cohorts. ΔPSA only correlated with ΔSUV\(_{maxall}\) (r = 0.60, p = 0.02) and with ΔSUV\(_{max10}\) (r = 0.53, p = 0.03) in the mHSPC cohort, as well as with ΔSUV\(_{maxall}\) (r = 0.51, p = 0.01) in the RLT cohort. (4) Conclusion: Response assessment using PSMA-TV with a reduced number of lesions is feasible, and may allow for a simplified evaluation process for PSMA PET/CT.}, language = {en} } @article{WernerMarcusSheikhbahaeietal.2018, author = {Werner, Rudolf A. and Marcus, Charles and Sheikhbahaei, Sara and Solnes, Lilja B. and Leal, Jeffrey P. and Du, Yong and Rowe, Steven P. and Higuchi, Takahiro and Buck, Andreas K. and Lapa, Constantin and Javadi, Mehrbod S.}, title = {Visual and Semiquantitative Accuracy in Clinical Baseline 123I-Ioflupane SPECT/CT Imaging}, series = {Clinical Nuclear Medicine}, volume = {44}, journal = {Clinical Nuclear Medicine}, number = {1}, issn = {1536-0229}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-168181}, year = {2018}, abstract = {PURPOSE: We aimed to (a) elucidate the concordance of visual assessment of an initial I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists. METHODS: An initial I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software. RESULTS: When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5\%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7\%, ĸ = 0.75) compared to semiquantification (86.2\%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found. CONCLUSIONS: In comparison with a fully automatic semiquantitative method in I-ioflupane interpretation, human assessment obtained an almost perfect agreement rate. However, compared to clinical established diagnosis serving as a reference, visual read seemed to be slightly more accurate as a solely software-based quantitative assessment.}, subject = {SPECT}, language = {en} } @article{HoffmannJanssenKannoetal.2020, author = {Hoffmann, Jan V. and Janssen, Jan P. and Kanno, Takayuki and Shibutani, Takayuki and Onoguchi, Masahisa and Lapa, Constantin and Grunz, Jan-Peter and Buck, Andreas K. and Higuchi, Takahiro}, title = {Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging}, series = {EJNMMI Physics}, volume = {7}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-020-00335-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230361}, year = {2020}, abstract = {Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT\(^+\)). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with \(^{99m}\)Tc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT\(^+\) for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT\(^+\). In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7\% (XUHR-M), 29.1\% (GP-M, U-SPECT5-E), 16.3\% (GP-M, U-SPECT\(^+\)) and 23.0\% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.}, language = {en} } @article{JanssenHoffmannKannoetal.2020, author = {Janssen, Jan P. and Hoffmann, Jan V. and Kanno, Takayuki and Nose, Naoko and Grunz, Jan-Peter and Onoguchi, Masahisa and Chen, Xinyu and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro}, title = {Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, doi = {10.1038/s41598-020-75696-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230616}, year = {2020}, abstract = {We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5\%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.}, language = {en} } @article{WernerHaenscheidLealetal.2018, author = {Werner, Rudolf and H{\"a}nscheid, Heribert and Leal, Jeffrey P. and Javadi, Mehrbod S. and Higuchi, Takahiro and Lodge, Martin A. and Buck, Andreas K. and Pomper, Martin G. and Lapa, Constantin and Rowe, Steven P.}, title = {Impact of Tumor Burden on Quantitative [\(^{68}\)Ga]DOTATOC Biodistribution}, series = {Molecular Imaging and Biology}, journal = {Molecular Imaging and Biology}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-170280}, pages = {1-9}, year = {2018}, abstract = {Purpose: As has been previously reported, the somatostatin receptor (SSTR) imaging agent [\(^{68}\)Ga]-labeled 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-d-Phe(1)-Tyr(3)-octreotate ([\(^{68}\)Ga]DOTATATE) demonstrates lower uptake in normal organs in patients with a high neuroendocrine tumor (NET) burden. Given the higher SSTR affinity of [\(^{68}\)Ga]DOTATATE, we aimed to quantitatively investigate the biodistribution of [\(^{68}\)Ga]-labeled 1,4,7,10-tetraazacyclododecane-N,N',N'',N'''-tetraacetic acid-d-Phe(1)-Tyr(3)-octreotide ([68Ga]DOTATOC) to determine a potential correlation between uptake in normal organs and NET burden. Procedures: Of the 44 included patients, 36/44 (82\%) patients demonstrated suspicious radiotracer uptake on [\(^{68}\)Ga]DOTATOC positron emission tomography (PET)/x-ray computed tomography (CT). Volumes of Interest (VOIs) were defined for tumor lesions and normal organs (spleen, liver, kidneys, adrenals). Mean body weight corrected standardized uptake value (SUV\(_{mean}\)) for normal organs was assessed and was used to calculate the corresponding mean specific activity uptake (Upt: fraction of injected activity per kg of tissue). For the entire tumor burden, SUV\(_{mean}\), maximum standardized uptake value (SUV\(_{max}\)), and the total mass (TBM) was calculated and the decay corrected tumor fractional uptake (TBU) was assessed. A Spearman's rank correlation coefficient was used to determine the correlations between normal organ uptake and tumor burden. Results: The median SUV\(_{mean}\) was 18.7 for the spleen (kidneys, 9.2; adrenals, 6.8; liver, 5.6). For tumor burden, the median values were SUV\(_{mean}\) 6.9, SUV\(_{max}\) 35.5, TBM 42.6g, and TBU 1.2\%. With increasing volume of distribution, represented by lean body mass and body surface area (BSA), Upt decreased in kidneys, liver, and adrenal glands and SUV\(_{mean}\) increased in the spleen. Correlation improved only for both kidneys and adrenals when the influence of the tumor uptake on the activity available for organ uptake was taken into account by the factor 1/(1-TBU). TBU was neither predictive for SUV\(_{mean}\) nor for Upt in any of the organs. The distribution of organ Upt vs. BSA/(1-TBU) were not different for patients with minor TBU (<3\%) vs. higher TBU (>7\%), indicating that the correlations observed in the present study are explainable by the body size effect. High tumor mass and uptake mitigated against G1 NET. Conclusions: There is no significant impact on normal organ biodistribution with increasing tumor burden on [\(^{68}\)Ga]DOTATOC PET/CT. Potential implications include increased normal organ dose with [\(^{177}\)Lu-DOTA]\(^0\)-D-Phe\(^1\)-Tyr\(^3\)-Octreotide and decreased absolute lesion detection with [\(^{68}\)Ga]DOTATOC in high NET burden.}, subject = {Positronen-Emissions-Tomografie}, language = {en} } @article{TamihardjaZehnerHartrampfetal.2022, author = {Tamihardja, J{\"o}rg and Zehner, Leonie and Hartrampf, Philipp E. and Cirsi, Sinan and Wegener, Sonja and Buck, Andreas K. and Flentje, Michael and Polat, B{\"u}lent}, title = {Dose-escalated salvage radiotherapy for macroscopic local recurrence of prostate cancer in the prostate-specific membrane antigen positron emission tomography era}, series = {Cancers}, volume = {14}, journal = {Cancers}, number = {19}, issn = {2072-6694}, doi = {10.3390/cancers14194956}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-290302}, year = {2022}, abstract = {Simple Summary Prostate cancer often relapses after initial radical prostatectomy, and salvage radiotherapy offers a second chance of cure for relapsed patients. Modern imaging techniques, especially prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT), enable radiation oncologists to target radiotherapy at the involved sites of disease. In a group of patients, PSMA PET/CT imaging can detect a macroscopic local recurrence with or without locoregional lymph node metastasis. In these cases, an escalation of the radiotherapy dose is often considered for controlling the visible tumor mass. As the evidence for dose-escalated salvage radiotherapy for macroscopic recurrent prostate cancer after PSMA PET/CT imaging is still limited, we address this topic in the current analysis. We found that the outcome of patients with dose-escalated salvage radiotherapy for macroscopic prostate cancer recurrence is encouragingly favorable, while the toxicity is very limited. Abstract Background: The purpose of this study was to access the oncological outcome of prostate-specific membrane antigen positron emission tomography (PSMA PET/CT)-guided salvage radiotherapy (SRT) for localized macroscopic prostate cancer recurrence. Methods: Between February 2010 and June 2021, 367 patients received SRT after radical prostatectomy. Out of the 367 screened patients, 111 patients were staged by PSMA PET/CT before SRT. A total of 59 out of these 111 (53.2\%) patients were treated for PSMA PET-positive macroscopic prostatic fossa recurrence. Dose-escalated SRT was applied with a simultaneous integrated boost at a median prescribed dose of 69.3 Gy (IQR 69.3-72.6 Gy). The oncological outcome was investigated using Kaplan-Meier and Cox regression analyses. The genitourinary (GU)/gastrointestinal (GI) toxicity evaluation utilized Common Toxicity Criteria for Adverse Events (version 5.0). Results: The median follow-up was 38.2 months. The three-year biochemical progression-free survival rate was 89.1\% (95\% CI: 81.1-97.8\%) and the three-year metastasis-free survival rate reached 96.2\% (95\% CI: 91.2-100.0\%). The cumulative three-year late grade 3 GU toxicity rate was 3.4\%. No late grade 3 GI toxicity occurred. Conclusions: Dose-escalated PSMA PET/CT-guided salvage radiotherapy for macroscopic prostatic fossa recurrence resulted in favorable survival and toxicity rates.}, language = {en} } @article{HartrampfPetritschBucketal.2020, author = {Hartrampf, Philipp E. and Petritsch, Bernhard and Buck, Andreas K. and Serfling, Sebastian E.}, title = {Pitfalls in PSMA-PET/CT: Intensive bone-marrow uptake in a case with polycythaemia vera}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {48}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, issn = {1619-7070}, doi = {10.1007/s00259-020-05072-7}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-235608}, pages = {1669-1670}, year = {2020}, abstract = {No abstract available.}, language = {en} } @article{WernerHabachaLuetjeetal.2022, author = {Werner, Rudolf A. and Habacha, Bil{\^e}l and L{\"u}tje, Susanne and Bundschuh, Lena and Higuchi, Takahiro and Hartrampf, Philipp and Serfling, Sebastian E. and Derlin, Thorsten and Lapa, Constantin and Buck, Andreas K. and Essler, Markus and Pienta, Kenneth J. and Eisenberger, Mario A. and Markowski, Mark C. and Shinehouse, Laura and AbdAllah, Rehab and Salavati, Ali and Lodge, Martin A. and Pomper, Martin G. and Gorin, Michael A. and Bundschuh, Ralph A. and Rowe, Steven P.}, title = {High SUVs Have More Robust Repeatability in Patients with Metastatic Prostate Cancer: Results from a Prospective Test-Retest Cohort Imaged with \(^{18}\)F-DCFPyL}, series = {Molecular Imaging}, volume = {2022}, journal = {Molecular Imaging}, doi = {10.1155/2022/7056983}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-300748}, year = {2022}, abstract = {No abstract available.}, language = {en} } @article{HartrampfLapaSerflingetal.2021, author = {Hartrampf, Philipp E. and Lapa, Constantin and Serfling, Sebastian E. and Buck, Andreas K. and Seitz, Anna Katharina and Meyer, Philipp T. and Ruf, Juri and Michalski, Kerstin}, title = {Development of Discordant Hypermetabolic Prostate Cancer Lesions in the Course of [\(^{177}\)Lu]PSMA Radioligand Therapy and Their Possible Influence on Patient Outcome}, series = {Cancers}, volume = {13}, journal = {Cancers}, number = {17}, issn = {2072-6694}, doi = {10.3390/cancers13174270}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-245168}, year = {2021}, abstract = {Simple Summary Discordant FDG-positive but PSMA-negative (FDG+/PSMA-) metastases constitute a negative prognostic marker of overall survival in patients undergoing PSMA radioligand therapy (RLT). The aim of this analysis was to investigate the prognostic implications of new FDG+/PSMA- lesions, which occur during or after PSMA RLT. In a retrospective bicentric analysis of 32 patients undergoing PSMA RLT and follow-up dual tracer staging with PSMA and FDG PET/CT, FDG+/PSMA- lesions occurred in a limited number of patients. However, the presence of FDG+/PSMA- lesions appears not to have a significant impact on the OS, but further studies are needed to establish the clinical relevance of such lesions. Abstract Introduction: Positron emission tomography/computer tomography (PET/CT) targeting the prostate-specific membrane antigen (PSMA) is crucial for the assessment of adequate PSMA expression in patients with metastatic castration-resistant prostate cancer (mCRPC) prior to PSMA radioligand therapy (PSMA RLT). Moreover, initial dual tracer staging using combined PSMA and [\(^{18}\)F]fluorodeoxyglucose (FDG) PET/CT provides relevant information, since discordant FDG-positive but PSMA-negative (FDG+/PSMA-) lesions constitute a negative prognostic marker of overall survival (OS) after PSMA RLT. However, little is known about the prognostic implications of dual tracer imaging for restaging at follow-up. The aim of this analysis was to investigate the prognostic implications of new FDG+/PSMA- lesions during or after PSMA RLT. Methods: This bicentric analysis included 32 patients with mCRPC who underwent both FDG and PSMA PET/CT imaging after two or four cycles of PSMA RLT. Patients with FDG+/PSMA- lesions prior to PSMA RLT were not considered. The presence of FDG+/PSMA- lesions was assessed with follow-up dual tracer imaging of patients after two or four cycles of PSMA RLT. Patients with at least one new FDG+/PSMA- lesion were compared to patients without any FDG+/PSMA- lesions at the respective time points. A log-rank analysis was used to assess the difference in OS between subgroups. Results: After two cycles of PSMA RLT, four of 32 patients (13\%) had FDG+/PSMA- metastases. No significant difference in OS was observed (p = 0.807), as compared to patients without FDG+/PSMA- lesions. Follow-up dual tracer imaging after the 4th cycle of PSMA RLT was available in 18 patients. Of these, four patients presented with FDG+/PSMA- findings (n = 2 already after two cycles). After the fourth cycle of PSMA RLT, no significant difference in OS was observed between patients with and without FDG+/PSMA- lesions (p = 0.442). Conclusion: This study shows that FDG+/PSMA- lesions develop in a limited number of patients undergoing PSMA RLT. Further studies are needed to establish the clinical relevance of such lesions.}, language = {en} } @article{HartrampfWeinzierlSerflingetal.2022, author = {Hartrampf, Philipp E. and Weinzierl, Franz-Xaver and Serfling, Sebastian E. and Pomper, Martin G. and Rowe, Steven P. and Higuchi, Takahiro and Seitz, Anna Katharina and K{\"u}bler, Hubert and Buck, Andreas K. and Werner, Rudolf A.}, title = {Hematotoxicity and nephrotoxicity in prostate cancer patients undergoing radioligand therapy with [\(^{177}\)Lu]Lu-PSMA I\&T}, series = {Cancers}, volume = {14}, journal = {Cancers}, number = {3}, issn = {2072-6694}, doi = {10.3390/cancers14030647}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-254825}, year = {2022}, abstract = {(1) Background: Prostate-specific membrane antigen (PSMA)-directed radioligand therapy (RLT) has shown remarkable results in patients with advanced prostate cancer. We aimed to evaluate the toxicity profile of the PSMA ligand [\(^{177}\)Lu]Lu-PSMA I\&T. (2) Methods: 49 patients with metastatic, castration-resistant prostate cancer treated with at least three cycles of [\(^{177}\)Lu]Lu-PSMA I\&T were evaluated. Prior to and after RLT, we compared leukocytes, hemoglobin, platelet counts, and renal functional parameters (creatinine, eGFR, n = 49; [\(^{99m}\)Tc]-MAG3-derived tubular extraction rate (TER), n = 42). Adverse events were classified according to the Common Terminology Criteria for Adverse Events (CTCAE) v5.0 and KDIGO Society. To identify predictive factors, we used Spearman's rank correlation coefficient. (3) Results: A substantial fraction of the patients already showed impaired renal function and reduced leukocyte counts at baseline. Under RLT, 11/49 (22\%) patients presented with nephrotoxicity CTCAE I or II according to creatinine, but 33/49 (67\%) according to eGFR. Only 5/42 (13\%) showed reduced TER, defined as <70\% of the age-adjusted mean normal values. Of all renal functional parameters, absolute changes of only 2\% were recorded. CTCAE-based re-categorization was infrequent, with creatinine worsening from I to II in 2/49 (4.1\%; GFR, 1/49 (2\%)). Similar results were recorded for KDIGO (G2 to G3a, 1/49 (2\%); G3a to G3b, 2/49 (4.1\%)). After three cycles, follow-up eGFR correlated negatively with age (r = -0.40, p = 0.005) and the eGFR change with Gleason score (r = -0.35, p < 0.05) at baseline. Leukocytopenia CTCAE II occurred only in 1/49 (2\%) (CTCAE I, 20/49 (41\%)) and CTCAE I thrombocytopenia in 7/49 (14\%), with an absolute decrease of 15.2\% and 16.6\% for leukocyte and platelet counts. Anemia CTCAE II occurred in 10/49 (20\%) (CTCAE I, 36/49 (73\%)) with a decrease in hemoglobin of 4.7\%. (4) Conclusions: After PSMA-targeted therapy using [\(^{177}\)Lu]Lu-PSMA I\&T, no severe (CTCAE III/IV) toxicities occurred, thereby demonstrating that serious adverse renal or hematological events are unlikely to be a frequent phenomenon with this agent.}, language = {en} } @article{WernerSayehliHaenscheidetal.2023, author = {Werner, Rudolf A. and Sayehli, Cyrus and H{\"a}nscheid, Heribert and Higuchi, Takahiro and Serfling, Sebastian E. and Fassnacht, Martin and Goebeler, Maria-Elisabeth and Buck, Andreas K. and Kroiss, Matthias}, title = {Successful combination of selpercatinib and radioiodine after pretherapeutic dose estimation in RET-altered thyroid carcinoma}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {50}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {6}, doi = {10.1007/s00259-022-06061-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324435}, pages = {1833-1834}, year = {2023}, abstract = {No abstract available.}, language = {en} } @article{WeichHiguchiBundschuhetal.2022, author = {Weich, Alexander and Higuchi, Takahiro and Bundschuh, Ralph A. and Lapa, Constantin and Serfling, Sebastian E. and Rowe, Steven P. and Pomper, Martin G. and Herrmann, Ken and Buck, Andreas K. and Derlin, Thorsten and Werner, Rudolf A.}, title = {Training on reporting and data system (RADS) for somatostatin-receptor targeted molecular imaging can reduce the test anxiety of inexperienced readers}, series = {Molecular Imaging and Biology}, volume = {24}, journal = {Molecular Imaging and Biology}, number = {4}, doi = {10.1007/s11307-022-01712-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324645}, pages = {631-640}, year = {2022}, abstract = {Purpose For somatostatin receptor (SSTR)-positron emission tomography/computed tomography (PET/CT), a standardized framework termed SSTR-reporting and data system (RADS) has been proposed. We aimed to elucidate the impact of a RADS-focused training on reader's anxiety to report on SSTR-PET/CT, the motivational beliefs in learning such a system, whether it increases reader's confidence, and its implementation in clinical routine. Procedures A 3-day training course focusing on SSTR-RADS was conducted. Self-report questionnaires were handed out prior to the course (Pre) and thereafter (Post). The impact of the training on the following categories was evaluated: (1) test anxiety to report on SSTR-PET/CT, (2) motivational beliefs, (3) increase in reader's confidence, and (4) clinical implementation. To assess the effect size of the course, Cohen's d was calculated (small, d = 0.20; large effect, d = 0.80). Results Of 22 participants, Pre and Post were returned by 21/22 (95.5\%). In total, 14/21 (66.7\%) were considered inexperienced (IR, < 1 year experience in reading SSTR-PET/CTs) and 7/21 (33.3\%) as experienced readers (ER, > 1 year). Applying SSTR-RADS, a large decrease in anxiety to report on SSTR-PET/CT was noted for IR (d =  - 0.74, P = 0.02), but not for ER (d = 0.11, P = 0.78). For the other three categories motivational beliefs, reader's confidence, and clinical implementation, agreement rates were already high prior to the training and persisted throughout the course (P ≥ 0.21). Conclusions A framework-focused reader training can reduce anxiety to report on SSTR-PET/CTs, in particular for inexperienced readers. This may allow for a more widespread adoption of this system, e.g., in multicenter trials for better intra- and interindividual comparison of scan results.}, language = {en} } @article{GoeringSchumannMuelleretal.2022, author = {G{\"o}ring, Lukas and Schumann, Sarah and M{\"u}ller, Jessica and Buck, Andreas K. and Port, Matthias and Lassmann, Michael and Scherthan, Harry and Eberlein, Uta}, title = {Repair of a-particle-induced DNA damage in peripheral blood mononuclear cells after internal ex vivo irradiation with \(^{223}\)Ra}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {12}, doi = {10.1007/s00259-022-05860-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324557}, pages = {3981-3988}, year = {2022}, abstract = {Purpose As α-emitters for radiopharmaceutical therapies are administered systemically by intravenous injection, blood will be irradiated by α-particles that induce clustered DNA double-strand breaks (DSBs). Here, we investigated the induction and repair of DSB damage in peripheral blood mononuclear cells (PBMCs) as a function of the absorbed dose to the blood following internal ex vivo irradiation with [\(^{223}\)Ra]RaCl2. Methods Blood samples of ten volunteers were irradiated by adding [\(^{223}\)Ra]RaCl2 solution with different activity concentrations resulting in absorbed doses to the blood of 3 mGy, 25 mGy, 50 mGy and 100 mGy. PBMCs were isolated, divided in three parts and either fixed directly (d-samples) or after 4 h or 24 h culture. After immunostaining, the induced γ-H2AX α-tracks were counted. The time-dependent decrease in α-track frequency was described with a model assuming a repair rate R and a fraction of non-repairable damage Q. Results For 25 mGy, 50 mGy and 100 mGy, the numbers of α-tracks were significantly increased compared to baseline at all time points. Compared to the corresponding d-samples, the α-track frequency decreased significantly after 4 h and after 24 h. The repair rates R were (0.24 ± 0.05) h-1 for 25 mGy, (0.16 ± 0.04) h-1 for 50 mGy and (0.13 ± 0.02) h-1 for 100 mGy, suggesting faster repair at lower absorbed doses, while Q-values were similar. Conclusion The results obtained suggest that induction and repair of the DSB damage depend on the absorbed dose to the blood. Repair rates were similar to what has been observed for irradiation with low linear energy transfer.}, language = {en} } @article{HartrampfBundschuhWeinzierletal.2022, author = {Hartrampf, Philipp E. and Bundschuh, Ralph A. and Weinzierl, Franz-Xaver and Serfling, Sebastian E. and Kosmala, Aleksander and Seitz, Anna Katharina and K{\"u}bler, Hubert and Buck, Andreas K. and Essler, Markus and Werner, Rudolf A.}, title = {mCRPC patients with PSA fluctuations under radioligand therapy have comparable survival benefits relative to patients with sustained PSA decrease}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {49}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, number = {13}, doi = {10.1007/s00259-022-05910-w}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-324562}, pages = {4727-4735}, year = {2022}, abstract = {Introduction In men with metastatic castration-resistant prostate cancer (mCRPC) scheduled for prostate-specific membrane antigen (PSMA)-targeted radioligand therapy (RLT), biochemical response is assessed based on repeated measurements of prostate-specific antigen (PSA) levels. We aimed to determine overall survival (OS) in patients experiencing sustained PSA increase, decrease, or fluctuations during therapy. Materials and methods In this bicentric study, we included 176 mCRPC patients treated with PSMA-directed RLT. PSA levels were determined using blood samples prior to the first RLT and on the admission days for the following cycles. We calculated relative changes in PSA levels compared to baseline. Kaplan-Meier curves as well as log-rank test were used to compare OS of different subgroups, including patients with sustained PSA increase, decrease, or fluctuations (defined as change after initial decrease or increase after the first cycle). Results Sixty-one out of one hundred seventy-six (34.7\%) patients showed a sustained increase and 86/176 (48.8\%) a sustained decrease in PSA levels. PSA fluctuations were observed in the remaining 29/176 (16.5\%). In this subgroup, 22/29 experienced initial PSA decrease followed by an increase (7/29, initial increase followed by a decrease). Median OS of patients with sustained decrease in PSA levels was significantly longer when compared to patients with sustained increase of PSA levels (19 vs. 8 months; HR 0.35, 95\% CI 0.22-0.56; P < 0.001). Patients with PSA fluctuations showed a significantly longer median OS compared to patients with sustained increase of PSA levels (18 vs. 8 months; HR 0.49, 95\% CI 0.30-0.80; P < 0.01), but no significant difference relative to men with sustained PSA decrease (18 vs. 19 months; HR 1.4, 95\% CI 0.78-2.49; P = 0.20). In addition, in men experiencing PSA fluctuations, median OS did not differ significantly between patients with initial decrease or initial increase of tumor marker levels (16 vs. 18 months; HR 1.2, 95\% CI 0.38-4.05; P = 0.68). Conclusion Initial increase or decrease of PSA levels is sustained in the majority of patients undergoing RLT. Sustained PSA decrease was linked to prolonged survival and men with PSA fluctuations under treatment experienced comparable survival benefits. As such, transient tumor marker oscillations under RLT should rather not lead to treatment discontinuation, especially in the absence of radiological progression.}, language = {en} } @article{IsraelRiehlButtetal.2023, author = {Israel, Ina and Riehl, Gabriele and Butt, Elke and Buck, Andreas K. and Samnick, Samuel}, title = {Gallium-68-labeled KISS1-54 peptide for mapping KISS1 receptor via PET: initial evaluation in human tumor cell lines and in tumor-bearing mice}, series = {Pharmaceuticals}, volume = {17}, journal = {Pharmaceuticals}, number = {1}, issn = {1424-8247}, doi = {10.3390/ph17010044}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-355898}, year = {2023}, abstract = {Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7\% radiochemical yield and at a >99\% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6-4.4\% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.}, language = {en} }