@article{HartrampfKrebsPeteretal.2022, author = {Hartrampf, Philipp E. and Krebs, Markus and Peter, Lea and Heinrich, Marieke and Ruffing, Julia and Kalogirou, Charis and Weinke, Maximilian and Brumberg, Joachim and K{\"u}bler, Hubert and Buck, Andreas K. and Werner, Rudolf A. and Seitz, Anna Katharina}, title = {Reduced segmentation of lesions is comparable to whole-body segmentation for response assessment by PSMA PET/CT: initial experience with the keyhole approach}, series = {Biology}, volume = {11}, journal = {Biology}, number = {5}, issn = {2079-7737}, doi = {10.3390/biology11050660}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-271191}, year = {2022}, abstract = {Simple Summary The calculation of PSMA-positive tumor volume (PSMA-TV) of the whole body from PSMA PET scans for response evaluation remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative tumor lesions. Changes in the whole-body PSMA-TV of 65 patients were comparable to the changes in PSMA-TV after including only the ten largest lesions. Moreover, changes in PSMA-TV correlated well with changes in PSA levels, as did the changes in PSMA-TV with the reduced number of lesions. We conclude that a response assessment using PSMA-TV with a reduced number of lesions is feasible and could lead to a simplified process for evaluating PSMA PET/CT. Abstract (1) Background: Prostate-specific membrane antigen (PSMA) positron emission tomography (PET)-derived parameters, such as the commonly used standardized uptake value (SUV) and PSMA-positive tumor volume (PSMA-TV), have been proposed for response assessment in metastatic prostate cancer (PCa) patients. However, the calculation of whole-body PSMA-TV remains a time-consuming procedure. We hypothesized that it may be possible to quantify changes in PSMA-TV by considering only a limited number of representative lesions. (2) Methods: Sixty-five patients classified into different disease stages were assessed by PSMA PET/CT for staging and restaging after therapy. Whole-body PSMA-TV and whole-body SUV\(_{max}\) were calculated. We then repeated this calculation only including the five or ten hottest or largest lesions. The corresponding serum levels of prostate-specific antigen (PSA) were also determined. The derived delta between baseline and follow-up values provided the following parameters: ΔSUV\(_{maxall}\), ΔSUV\(_{max10}\), ΔSUV\(_{max5}\), ΔPSMA-TV\(_{all}\), ΔPSMA-TV\(_{10}\), ΔPSMA-TV\(_{5}\), ΔPSA. Finally, we compared the findings from our whole-body segmentation with the results from our keyhole approach (focusing on a limited number of lesions) and correlated all values with the biochemical response (ΔPSA). (3) Results: Among patients with metastatic hormone-sensitive PCa (mHSPC), none showed a relevant deviation for ΔSUV\(_{max10}\)/ΔSUV\(_{max5}\) or ΔPSMA-TV\(_{10}\)/ΔPSMA-TV\(_{5}\) compared to ΔSUV\(_{maxall}\) and ΔPSMA-TV\(_{all}\). For patients treated with taxanes, up to 6/21 (28.6\%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only up to 2/21 (9.5\%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). For patients treated with radioligand therapy (RLT), up to 5/28 (17.9\%) showed clinically relevant deviations between ΔSUV\(_{maxall}\) and ΔSUV\(_{max10}\) or ΔSUV\(_{max5}\), but only 1/28 (3.6\%) patients showed clinically relevant deviations between ΔPSMA-TV\(_{all}\) and ΔPSMA-TV\(_{10}\) or ΔPSMA-TV\(_{5}\). The highest correlations with ΔPSA were found for ΔPSMA-TV\(_{all}\) (r ≥ 0.59, p ≤ 0.01), followed by ΔPSMA-TV\(_{10}\) (r ≥ 0.57, p ≤ 0.01) and ΔPSMA-TV\(_{5}\) (r ≥ 0.53, p ≤ 0.02) in all cohorts. ΔPSA only correlated with ΔSUV\(_{maxall}\) (r = 0.60, p = 0.02) and with ΔSUV\(_{max10}\) (r = 0.53, p = 0.03) in the mHSPC cohort, as well as with ΔSUV\(_{maxall}\) (r = 0.51, p = 0.01) in the RLT cohort. (4) Conclusion: Response assessment using PSMA-TV with a reduced number of lesions is feasible, and may allow for a simplified evaluation process for PSMA PET/CT.}, language = {en} } @article{WernerMarcusSheikhbahaeietal.2018, author = {Werner, Rudolf A. and Marcus, Charles and Sheikhbahaei, Sara and Solnes, Lilja B. and Leal, Jeffrey P. and Du, Yong and Rowe, Steven P. and Higuchi, Takahiro and Buck, Andreas K. and Lapa, Constantin and Javadi, Mehrbod S.}, title = {Visual and Semiquantitative Accuracy in Clinical Baseline 123I-Ioflupane SPECT/CT Imaging}, series = {Clinical Nuclear Medicine}, volume = {44}, journal = {Clinical Nuclear Medicine}, number = {1}, issn = {1536-0229}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-168181}, year = {2018}, abstract = {PURPOSE: We aimed to (a) elucidate the concordance of visual assessment of an initial I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists. METHODS: An initial I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software. RESULTS: When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5\%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7\%, ĸ = 0.75) compared to semiquantification (86.2\%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found. CONCLUSIONS: In comparison with a fully automatic semiquantitative method in I-ioflupane interpretation, human assessment obtained an almost perfect agreement rate. However, compared to clinical established diagnosis serving as a reference, visual read seemed to be slightly more accurate as a solely software-based quantitative assessment.}, subject = {SPECT}, language = {en} } @article{HoffmannJanssenKannoetal.2020, author = {Hoffmann, Jan V. and Janssen, Jan P. and Kanno, Takayuki and Shibutani, Takayuki and Onoguchi, Masahisa and Lapa, Constantin and Grunz, Jan-Peter and Buck, Andreas K. and Higuchi, Takahiro}, title = {Performance evaluation of fifth-generation ultra-high-resolution SPECT system with two stationary detectors and multi-pinhole imaging}, series = {EJNMMI Physics}, volume = {7}, journal = {EJNMMI Physics}, doi = {10.1186/s40658-020-00335-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230361}, year = {2020}, abstract = {Background Small-animal single-photon emission computed tomography (SPECT) systems with multi-pinhole collimation and large stationary detectors have advantages compared to systems with moving small detectors. These systems benefit from less labour-intensive maintenance and quality control as fewer prone parts are moving, higher accuracy for focused scans and maintaining high resolution with increased sensitivity due to focused pinholes on the field of view. This study aims to investigate the performance of a novel ultra-high-resolution scanner with two-detector configuration (U-SPECT5-E) and to compare its image quality to a conventional micro-SPECT system with three stationary detectors (U-SPECT\(^+\)). Methods The new U-SPECT5-E with two stationary detectors was used for acquiring data with \(^{99m}\)Tc-filled point source, hot-rod and uniformity phantoms to analyse sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR). Three dedicated multi-pinhole mouse collimators with 75 pinholes each and 0.25-, 0.60- and 1.00-mm pinholes for extra ultra-high resolution (XUHR-M), general-purpose (GP-M) and ultra-high sensitivity (UHS-M) imaging were examined. For CNR analysis, four different activity ranges representing low- and high-count settings were investigated for all three collimators. The experiments for the performance assessment were repeated with the same GP-M collimator in the three-detector U-SPECT\(^+\) for comparison. Results Peak sensitivity was 237 cps/MBq (XUHR-M), 847 cps/MBq (GP-M), 2054 cps/MBq (UHS-M) for U-SPECT5-E and 1710 cps/MBq (GP-M) for U-SPECT\(^+\). In the visually analysed sections of the reconstructed mini Derenzo phantoms, rods as small as 0.35 mm (XUHR-M), 0.50 mm (GP-M) for the two-detector as well as the three-detector SPECT and 0.75 mm (UHS-M) were resolved. Uniformity for maximum resolution recorded 40.7\% (XUHR-M), 29.1\% (GP-M, U-SPECT5-E), 16.3\% (GP-M, U-SPECT\(^+\)) and 23.0\% (UHS-M), respectively. UHS-M reached highest CNR values for low-count images; for rods smaller than 0.45 mm, acceptable CNR was only achieved by XUHR-M. GP-M was superior for imaging rods sized from 0.60 to 1.50 mm for intermediate activity concentrations. U-SPECT5-E and U-SPECT+ both provided comparable CNR. Conclusions While uniformity and sensitivity are negatively affected by the absence of a third detector, the investigated U-SPECT5-E system with two stationary detectors delivers excellent spatial resolution and CNR comparable to the performance of an established three-detector-setup.}, language = {en} } @article{JanssenHoffmannKannoetal.2020, author = {Janssen, Jan P. and Hoffmann, Jan V. and Kanno, Takayuki and Nose, Naoko and Grunz, Jan-Peter and Onoguchi, Masahisa and Chen, Xinyu and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro}, title = {Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, doi = {10.1038/s41598-020-75696-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230616}, year = {2020}, abstract = {We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5\%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.}, language = {en} } @article{IsraelRiehlButtetal.2023, author = {Israel, Ina and Riehl, Gabriele and Butt, Elke and Buck, Andreas K. and Samnick, Samuel}, title = {Gallium-68-labeled KISS1-54 peptide for mapping KISS1 receptor via PET: initial evaluation in human tumor cell lines and in tumor-bearing mice}, series = {Pharmaceuticals}, volume = {17}, journal = {Pharmaceuticals}, number = {1}, issn = {1424-8247}, doi = {10.3390/ph17010044}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-355898}, year = {2023}, abstract = {Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7\% radiochemical yield and at a >99\% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6-4.4\% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.}, language = {en} }