@article{GrunzWenigKunzetal.2020, author = {Grunz, Jan-Peter and Wenig, Andreas Max and Kunz, Andreas Steven and Veyhl-Wichmann, Maike and Schmitt, Rainer and Gietzen, Carsten Herbert and Pennig, Lenhard and Herz, Stefan and Erg{\"u}n, S{\"u}leyman and Bley, Thorsten Alexander and Gassenmaier, Tobias}, title = {3D cone-beam CT with a twin robotic x-ray system in elbow imaging: comparison of image quality to high-resolution multidetector CT}, series = {European Radiology Experimental}, volume = {4}, journal = {European Radiology Experimental}, doi = {10.1186/s41747-020-00177-y}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229877}, year = {2020}, abstract = {Background Elbow imaging is challenging with conventional multidetector computed tomography (MDCT), while cone-beam CT (CBCT) provides superior options. We compared intra-individually CBCT versus MDCT image quality in cadaveric elbows. Methods A twin robotic x-ray system with new CBCT mode and a high-resolution clinical MDCT were compared in 16 cadaveric elbows. Both systems were operated with a dedicated low-dose (LD) protocol (equivalent volume CT dose index [CTDI\(_{vol(16 cm)}\)] = 3.3 mGy) and a regular clinical scan dose (RD) protocol (CTDI\(_{vol(16 cm)}\) = 13.8 mGy). Image quality was evaluated by two radiologists (R1 and R2) on a seven-point Likert scale, and estimation of signal intensity in cancellous bone was conducted. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) statistics were used. Results The CBCT prototype provided superior subjective image quality compared to MDCT scans (for RD, p ≤ 0.004; for LD, p ≤ 0.001). Image quality was rated very good or excellent in 100\% of the cases by both readers for RD CBCT, 100\% (R1) and 93.8\% (R2) for LD CBCT, 62.6\% and 43.8\% for RD MDCT, and 0.0\% and 0.0\% for LD MDCT. Single-measure ICC was 0.95 (95\% confidence interval 0.91-0.97; p < 0.001). Software-based assessment supported subjective findings with less "undecided" pixels in CBCT than dose-equivalent MDCT (p < 0.001). No significant difference was found between LD CBCT and RD MDCT. Conclusions In cadaveric elbow studies, the tested cone-beam CT prototype delivered superior image quality compared to high-end multidetector CT and showed a potential for considerable dose reduction.}, language = {en} } @article{HopfnerSchormairKnaufetal.2011, author = {Hopfner, Franziska and Schormair, Barbara and Knauf, Franziska and Berthele, Achim and T{\"o}lle, Thomas R. and Baron, Ralf and Maier, Christoph and Treede, Rolf-Detlef and Binder, Andreas and Sommer, Claudia and Maih{\"o}fner, Christian and Kunz, Wolfram and Zimprich, Friedrich and Heemann, Uwe and Pfeufer, Arne and N{\"a}bauer, Michael and K{\"a}{\"a}b, Stefan and Nowak, Barbara and Gieger, Christian and Lichtner, Peter and Trenkwalder, Claudia and Oexle, Konrad and Winkelmann, Juliane}, title = {Novel SCARB2 mutation in Action Myoclonus-Renal Failure syndrome and evaluation of SCARB2 mutations in isolated AMRF features}, series = {BMC Neurology}, volume = {11}, journal = {BMC Neurology}, number = {134}, doi = {10.1186/1471-2377-11-134}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-141209}, pages = {1-8}, year = {2011}, abstract = {Background: Action myoclonus-renal failure syndrome is a hereditary form of progressive myoclonus epilepsy associated with renal failure. It is considered to be an autosomal-recessive disease related to loss-of-function mutations in SCARB2. We studied a German AMRF family, additionally showing signs of demyelinating polyneuropathy and dilated cardiomyopathy. To test the hypothesis whether isolated appearance of individual AMRF syndrome features could be related to heterozygote SCARB2 mutations, we screened for SCARB2 mutations in unrelated patients showing isolated AMRF features. Methods: In the AMRF family all exons of SCARB2 were analyzed by Sanger sequencing. The mutation screening of unrelated patients with isolated AMRF features affected by either epilepsy (n = 103, progressive myoclonus epilepsy or generalized epilepsy), demyelinating polyneuropathy (n = 103), renal failure (n = 192) or dilated cardiomyopathy (n = 85) was performed as high resolution melting curve analysis of the SCARB2 exons. Results: A novel homozygous 1 bp deletion (c.111delC) in SCARB2 was found by sequencing three affected homozygous siblings of the affected family. A heterozygous sister showed generalized seizures and reduction of nerve conduction velocity in her legs. No mutations were found in the epilepsy, renal failure or dilated cardiomyopathy samples. In the polyneuropathy sample two individuals with demyelinating disease were found to be carriers of a SCARB2 frameshift mutation (c.666delCCTTA). Conclusions: Our findings indicate that demyelinating polyneuropathy and dilated cardiomyopathy are part of the action myoclonus-renal failure syndrome. Moreover, they raise the possibility that in rare cases heterozygous SCARB2 mutations may be associated with PNP features.}, language = {en} } @article{PetritschKoestlerGassenmaieretal.2016, author = {Petritsch, Bernhard and K{\"o}stler, Herbert and Gassenmaier, Tobias and Kunz, Andreas S and Bley, Thorsten A and Horn, Michael}, title = {An investigation into potential gender-specific differences in myocardial triglyceride content assessed by \(^{1}\)H-Magnetic Resonance Spectroscopy at 3Tesla}, series = {Journal of International Medical Research}, volume = {44}, journal = {Journal of International Medical Research}, number = {3}, doi = {10.1177/0300060515603884}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-168808}, pages = {585-591}, year = {2016}, abstract = {Objective: Over the past decade, myocardial triglyceride content has become an accepted biomarker for chronic metabolic and cardiac disease. The purpose of this study was to use proton (hydrogen 1)-magnetic resonance spectroscopy (\(^{1}\)H-MRS) at 3Tesla (3 T) field strength to assess potential gender-related differences in myocardial triglyceride content in healthy individuals. Methods: Cardiac MR imaging was performed to enable accurate voxel placement and obtain functional and morphological information. Double triggered (i.e., ECG and respiratory motion gating) \(^{1}\)H-MRS was used to quantify myocardial triglyceride levels for each gender. Two-sample t-test and Mann-Whitney U-test were used for statistical analyses. Results: In total, 40 healthy volunteers (22 male, 18 female; aged >18 years and age matched) were included in the study. Median myocardial triglyceride content was 0.28\% (interquartile range [IQR] 0.17-0.42\%) in male and 0.24\% (IQR 0.14-0.45\%) in female participants, and no statistically significant difference was observed between the genders. Furthermore, no gender-specific difference in ejection fraction was observed, although on average, male participants presented with a higher mean ± SD left ventricular mass (136.3 ± 25.2 g) than female participants (103.9 ± 16.1 g). Conclusions: The study showed that \(^{1}\)H-MRS is a capable, noninvasive tool for acquisition of myocardial triglyceride metabolites. Myocardial triglyceride concentration was shown to be unrelated to gender in this group of healthy volunteers.}, language = {en} } @article{SauerGoltzGassenmaieretal.2014, author = {Sauer, Stephanie and Goltz, Jan P. and Gassenmaier, Tobias and Kunz, Andreas S. and Bley, Thorsten A. and Klein, Detlef and Petritsch, Bernhard}, title = {Partial Segmental Thrombosis of the Corpus Cavernosum (PSTCC) diagnosed by contrast-enhanced ultrasound: a case report}, series = {BMC Urology}, volume = {14}, journal = {BMC Urology}, number = {100}, doi = {10.1186/1471-2490-14-100}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-126495}, year = {2014}, abstract = {Background Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition. Case presentation We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid. Conclusion PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit.}, language = {en} } @article{GassenmaierPetritschKunzetal.2015, author = {Gassenmaier, Tobias and Petritsch, Bernhard and Kunz, Andreas S. and Gkaniatsas, Spyridon and Gaudron, Philipp D. and Weidemann, Frank and Nordbeck, Peter and Beer, Meinrad}, title = {Long term evolution of MRI characteristics in a case of atypical left lateral wall hypertrophic cardiomyopathy}, series = {World Journal of Cardiology}, volume = {7}, journal = {World Journal of Cardiology}, number = {6}, doi = {10.4330/wjc.v7.i6.357}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-124934}, pages = {357-360}, year = {2015}, abstract = {We are reporting a long-time magnetic resonance imaging (MRI) follow-up in a rare case of cardiac left lateral wall hypertrophy. Hypertrophic cardiomyopathy (HCM) is the most common genetic cardiovascular disorder and a significant cause of sudden cardiac death. Cardiac magnetic resonance (CMR) imaging can be a valuable tool for assessment of detailed information on size, localization, and tissue characteristics of hypertrophied myocardium. However, there is still little knowledge of long-term evolution of HCM as visualized by magnetic resonance imaging. Recently, our group reported a case of left lateral wall HCM as a rare variant of the more common forms, such as septal HCM, or apical HCM. As we now retrieved an old cardiac MRI acquired in this patient more than 20 years ago, we are able to provide the thrilling experience of an ultra-long MRI follow-up presentation in this rare case of left lateral wall hypertrophy. Furthermore, this case outlines the tremendous improvements in imaging quality within the last two decades of CMR imaging.}, language = {en} } @article{StojanovićFuchsFiedleretal.2020, author = {Stojanović, Stevan D. and Fuchs, Maximilian and Fiedler, Jan and Xiao, Ke and Meinecke, Anna and Just, Annette and Pich, Andreas and Thum, Thomas and Kunz, Meik}, title = {Comprehensive bioinformatics identifies key microRNA players in ATG7-deficient lung fibroblasts}, series = {International Journal of Molecular Sciences}, volume = {21}, journal = {International Journal of Molecular Sciences}, number = {11}, issn = {1422-0067}, doi = {10.3390/ijms21114126}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-285181}, year = {2020}, abstract = {Background: Deficient autophagy has been recently implicated as a driver of pulmonary fibrosis, yet bioinformatics approaches to study this cellular process are lacking. Autophagy-related 5 and 7 (ATG5/ATG7) are critical elements of macro-autophagy. However, an alternative ATG5/ATG7-independent macro-autophagy pathway was recently discovered, its regulation being unknown. Using a bioinformatics proteome profiling analysis of ATG7-deficient human fibroblasts, we aimed to identify key microRNA (miR) regulators in autophagy. Method: We have generated ATG7-knockout MRC-5 fibroblasts and performed mass spectrometry to generate a large-scale proteomics dataset. We further quantified the interactions between various proteins combining bioinformatics molecular network reconstruction and functional enrichment analysis. The predicted key regulatory miRs were validated via quantitative polymerase chain reaction. Results: The functional enrichment analysis of the 26 deregulated proteins showed decreased cellular trafficking, increased mitophagy and senescence as the major overarching processes in ATG7-deficient lung fibroblasts. The 26 proteins reconstitute a protein interactome of 46 nodes and miR-regulated interactome of 834 nodes. The miR network shows three functional cluster modules around miR-16-5p, miR-17-5p and let-7a-5p related to multiple deregulated proteins. Confirming these results in a biological setting, serially passaged wild-type and autophagy-deficient fibroblasts displayed senescence-dependent expression profiles of miR-16-5p and miR-17-5p. Conclusions: We have developed a bioinformatics proteome profiling approach that successfully identifies biologically relevant miR regulators from a proteomics dataset of the ATG-7-deficient milieu in lung fibroblasts, and thus may be used to elucidate key molecular players in complex fibrotic pathological processes. The approach is not limited to a specific cell-type and disease, thus highlighting its high relevance in proteome and non-coding RNA research.}, language = {en} } @article{JordanJovicGilbertetal.2020, author = {Jordan, Martin C. and Jovic, Sebastian and Gilbert, Fabian and Kunz, Andreas and Ertl, Maximilian and Strobl, Ute and Jakubietz, Rafael G. and Jakubietz, Michael G. and Meffert, Rainer H. and Fuchs, Konrad F.}, title = {Qualit{\"a}tssteigerung der Abrechnungspr{\"u}fung durch Smartphone-basierte Fotodokumentation in der Unfall-, Hand-, und Plastischen Chirurgie}, series = {Der Unfallchirurg}, volume = {124}, journal = {Der Unfallchirurg}, issn = {0177-5537}, doi = {10.1007/s00113-020-00866-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-232415}, pages = {366-372}, year = {2020}, abstract = {Hintergrund Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungspr{\"u}fung durch den Medizinischen Dienst der Krankenkassen (MDK) hat. Fragestellung Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erl{\"o}srelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern? Material und Methoden Ausstattung der Mitarbeiter mit digitalen Endger{\"a}ten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungspr{\"u}fung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erl{\"o}sver{\"a}nderung bewirkt hat. Ergebnisse Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 F{\"a}llen (7,2 \%) zur Best{\"a}tigung eines Operationen- und Prozedurenschl{\"u}ssels (OPS) (n = 5; 1,3 \%), einer Hauptdiagnose (n = 10; 2,7 \%), einer Nebendiagnose (n = 3; 0,8 \%) oder der Krankenhausverweildauer (n = 9; 2,4 \%). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erl{\"o}ssteigerung von 2119 €. Inklusive Aufwandpauschale f{\"u}r die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt. Diskussion Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualit{\"a}t der Dokumentation verbessern und Erl{\"o}seinbußen bei der Abrechnungspr{\"u}fung verhindern. Die Implementierung digitaler Endger{\"a}te mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.}, language = {de} } @article{LuetkensErguenHuflageetal.2021, author = {Luetkens, Karsten Sebastian and Erg{\"u}n, S{\"u}leyman and Huflage, Henner and Kunz, Andreas Steven and Gietzen, Carsten Herbert and Conrads, Nora and Pennig, Lenhard and Goertz, Lukas and Bley, Thorsten Alexander and Gassenmaier, Tobias and Grunz, Jan-Peter}, title = {Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system}, series = {Scientific Reports}, volume = {11}, journal = {Scientific Reports}, number = {1}, doi = {10.1038/s41598-021-99748-1}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-270429}, year = {2021}, abstract = {Cone-beam computed tomography is a powerful tool for 3D imaging of the appendicular skeleton, facilitating detailed visualization of bone microarchitecture. This study evaluated various combinations of acquisition and reconstruction parameters for the cone-beam CT mode of a twin robotic x-ray system in cadaveric wrist and elbow scans, aiming to define the best possible trade-off between image quality and radiation dose. Images were acquired with different combinations of tube voltage and tube current-time product, resulting in five scan protocols with varying volume CT dose indices: full-dose (FD; 17.4 mGy), low-dose (LD; 4.5 mGy), ultra-low-dose (ULD; 1.15 mGy), modulated low-dose (mLD; 0.6 mGy) and modulated ultra-low-dose (mULD; 0.29 mGy). Each set of projection data was reconstructed with three convolution kernels (very sharp [Ur77], sharp [Br69], intermediate [Br62]). Five radiologists subjectively assessed the image quality of cortical bone, cancellous bone and soft tissue using seven-point scales. Irrespective of the reconstruction kernel, overall image quality of every FD, LD and ULD scan was deemed suitable for diagnostic use in contrast to mLD (very sharp/sharp/intermediate: 60/55/70\%) and mULD (0/3/5\%). Superior depiction of cortical and cancellous bone was achieved in FD\(_{Ur77}\) and LD\(_{Ur77}\) examinations (p < 0.001) with LD\(_{Ur77}\) scans also providing favorable bone visualization compared to FD\(_{Br69}\) and FD\(_{Br62}\) (p < 0.001). Fleiss' kappa was 0.618 (0.594-0.641; p < 0.001), indicating substantial interrater reliability. In this study, we demonstrate that considerable dose reduction can be realized while maintaining diagnostic image quality in upper extremity joint scans with the cone-beam CT mode of a twin robotic x-ray system. Application of sharper convolution kernels for image reconstruction facilitates superior display of bone microarchitecture.}, language = {en} } @article{HuflageKarstenKunzetal.2021, author = {Huflage, Henner and Karsten, Sebastian and Kunz, Andreas Steven and Conrads, Nora and Jakubietz, Rafael Gregor and Jakubietz, Michael Georg and Pennig, Lenhard and Goertz, Lukas and Bley, Thorsten Alexander and Schmitt, Rainer and Grunz, Jan-Peter}, title = {Improved diagnostic accuracy for ulnar-sided TFCC lesions with radial reformation of 3D sequences in wrist MR arthrography}, series = {European Radiology}, volume = {31}, journal = {European Radiology}, number = {12}, issn = {1432-1084}, doi = {10.1007/s00330-021-08024-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-266512}, pages = {9399-9407}, year = {2021}, abstract = {Objectives Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist. Methods Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated. Results Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7\%), 10 (10.8\%) and 9 (9.7\%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting. Conclusions Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions.}, language = {en} } @phdthesis{Kunz2022, author = {Kunz, Andreas Steven}, title = {Vergleich von 3D-konformaler und intensit{\"a}tsmodulierter Strahlentherapie beim nicht-kleinzelligen Bronchialkarzinom}, doi = {10.25972/OPUS-25339}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-253399}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2022}, abstract = {Die vorliegende Arbeit soll dazu dienen, die Strahlentherapie bei Patienten mit histologisch gesichertem, nicht-kleinzelligen Bronchialkarzinom nach 3D-konformalem sowie intensit{\"a}tsmoduliertem Schema anhand definierter Outcome-Parameter und ihrer Nebenwirkungsraten zu vergleichen. Insgesamt wurde f{\"u}r diese monozentrisch durchgef{\"u}hrte Studie mit retrospektivem Design ein Kollektiv aus 111 Patienten/-innen untersucht. Anhand des untersuchtem Kollektivs konnte gezeigt werden, dass beide Therapieverfahren bez{\"u}glich der {\"U}berlebensraten und der Rezidiv- bzw. Metastasierungsh{\"a}ufigkeit im Rahmen des beobachteten Studienzeitraums miteinander vergleichbar sind. Auch f{\"u}r die H{\"a}ufigkeit akuter Therapie-assoziierter Nebenwirkungen konnte kein signifikanter Unterschied zwischen den beiden Bestrahlungstechniken nachgewiesen werden; dagegen trat eine chronische Strahlenpneumonitis h{\"a}ufiger in der Patientengruppe auf, die prim{\"a}r eine 3D-CRT erhalten hatte.}, subject = {Nicht-kleinzelliges Bronchialkarzinom}, language = {de} }