@article{JakubietzNickelNeshkovaetal.2017, author = {Jakubietz, Rafael G. and Nickel, Aljoscha and Neshkova, Iva and Schmidt, Karsten and Gilbert, Fabian and Meffert, Rainer H. and Jakubietz, Michael G.}, title = {Long-term patency of twisted vascular pedicles in perforator-based propeller flaps}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {10}, doi = {10.1097/GOX.0000000000001544}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158870}, pages = {e1544}, year = {2017}, abstract = {Background: Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps. Methods: In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap. Results: The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss. Conclusions: The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.}, language = {en} } @article{JakubietzJakubietzMeffertetal.2017, author = {Jakubietz, Rafael G. and Jakubietz, Michael G. and Meffert, Rainer H. and Schmidt, Karsten}, title = {Multiple-level replantation in elderly patients: risk versus benefit}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {4}, doi = {10.1097/GOX.0000000000001313}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158443}, pages = {e1313}, year = {2017}, abstract = {Multiple-level amputations of the upper extremity represent a surgical challenge generally only attempted in young patients. This case demonstrates a successful replantation in an elderly woman. The postoperative course was complicated by disseminated intravascular coagulopathy most likely due to inadequate resuscitation. Hand trauma is often underestimated in its general severity. Upper extremity amputations need to be handled similar to polytraumatized patients.}, language = {en} } @article{JordanJovicGilbertetal.2020, author = {Jordan, Martin C. and Jovic, Sebastian and Gilbert, Fabian and Kunz, Andreas and Ertl, Maximilian and Strobl, Ute and Jakubietz, Rafael G. and Jakubietz, Michael G. and Meffert, Rainer H. and Fuchs, Konrad F.}, title = {Qualit{\"a}tssteigerung der Abrechnungspr{\"u}fung durch Smartphone-basierte Fotodokumentation in der Unfall-, Hand-, und Plastischen Chirurgie}, series = {Der Unfallchirurg}, volume = {124}, journal = {Der Unfallchirurg}, issn = {0177-5537}, doi = {10.1007/s00113-020-00866-8}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-232415}, pages = {366-372}, year = {2020}, abstract = {Hintergrund Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungspr{\"u}fung durch den Medizinischen Dienst der Krankenkassen (MDK) hat. Fragestellung Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erl{\"o}srelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern? Material und Methoden Ausstattung der Mitarbeiter mit digitalen Endger{\"a}ten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungspr{\"u}fung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erl{\"o}sver{\"a}nderung bewirkt hat. Ergebnisse Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 F{\"a}llen (7,2 \%) zur Best{\"a}tigung eines Operationen- und Prozedurenschl{\"u}ssels (OPS) (n = 5; 1,3 \%), einer Hauptdiagnose (n = 10; 2,7 \%), einer Nebendiagnose (n = 3; 0,8 \%) oder der Krankenhausverweildauer (n = 9; 2,4 \%). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erl{\"o}ssteigerung von 2119 €. Inklusive Aufwandpauschale f{\"u}r die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt. Diskussion Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualit{\"a}t der Dokumentation verbessern und Erl{\"o}seinbußen bei der Abrechnungspr{\"u}fung verhindern. Die Implementierung digitaler Endger{\"a}te mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.}, language = {de} } @article{HuflageKarstenKunzetal.2021, author = {Huflage, Henner and Karsten, Sebastian and Kunz, Andreas Steven and Conrads, Nora and Jakubietz, Rafael Gregor and Jakubietz, Michael Georg and Pennig, Lenhard and Goertz, Lukas and Bley, Thorsten Alexander and Schmitt, Rainer and Grunz, Jan-Peter}, title = {Improved diagnostic accuracy for ulnar-sided TFCC lesions with radial reformation of 3D sequences in wrist MR arthrography}, series = {European Radiology}, volume = {31}, journal = {European Radiology}, number = {12}, issn = {1432-1084}, doi = {10.1007/s00330-021-08024-3}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-266512}, pages = {9399-9407}, year = {2021}, abstract = {Objectives Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist. Methods Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated. Results Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7\%), 10 (10.8\%) and 9 (9.7\%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting. Conclusions Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions.}, language = {en} } @article{JakubietzSchmidtHolzapfeletal.2020, author = {Jakubietz, Rafael G. and Schmidt, Karsten and Holzapfel, Boris M. and Meffert, Rainer H. and Jakubietz, Michael G.}, title = {Pedicled perforator flaps for mid-tibial soft tissue reconstruction in medically compromised patients}, series = {JPRAS Open}, volume = {24}, journal = {JPRAS Open}, doi = {10.1016/j.jpra.2020.02.002}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229473}, pages = {47-55}, year = {2020}, abstract = {Background: The soft tissue of the central pretibial area is difficult to reconstruct often requiring free tissue transfer. Especially medi- cally compromised patients are not ideal candidates for free tissue transfer and may benefit from expeditiously harvested local flaps with limited donor site morbidity. As muscle flaps are rare, pedi- cled flaps based on lateral perforators represent an alternative as the arc of rotation can often be limited to 90 °. Material and Methods: A retrospective analysis of patient data was conducted to identify patients over the age of 60 years with comor- bidities that underwent pretibial soft tissue reconstruction with a single-pedicle perforator flap. Patient demographics, size and cause of the defect, flap dimension, arc of rotation and complications were recorded. Results: Five patients with an average age of 71.4 years were in- cluded. The arc of rotation was 69 °, all flaps healed. There were two recurrences of osteomyelitis. Conclusion: Lateral perforators originating from the anterior tib- ial artery or peroneal artery are adequate source vessels for single pedicled perforator flaps even in medically compromised patients. A perforator located proximal to the defect allows limiting the arcof rotation to less than 90 °, which increases the safety of the flap. Patients benefit from a simple procedure without a microvascular anastomosis and a donor site confined to one extremity}, language = {en} } @article{JakubietzMeffertSchmidtetal.2017, author = {Jakubietz, Michael G. and Meffert, Rainer H. and Schmidt, Karsten and Gruenert, Joerg G. and Jakubietz, Rafael G.}, title = {Acute A4 Pulley Reconstruction with a First Extensor Compartment Onlay Graft}, series = {Plastic and Reconstructive Surgery Global Open}, volume = {5}, journal = {Plastic and Reconstructive Surgery Global Open}, number = {6}, doi = {10.1097/GOX.0000000000001361}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-158057}, pages = {e1361}, year = {2017}, abstract = {Background: The integrity of the flexor tendon pulley apparatus is crucial for unimpaired function of the digits. Although secondary reconstruction is an established procedure in multi-pulley injuries, acute reconstruction of isolated, closed pulley ruptures is a rare occurrence. There are 3 factors influencing the functional outcome of a reconstruction: gapping distance between tendon and bone (E-space), bulkiness of the reconstruction, and stability. As direct repair is rarely done, grafts are used to reinforce the pulley. An advantage of the first extensor retinaculum graft is the synovial coating providing the possibility to be used both as a direct graft with synovial coating or as an onlay graft after removal of the synovia when the native synovial layer is present. Methods: A graft from the first dorsal extensor compartment is used as an onlay graft to reinforce the sutured A4 pulley. This technique allows reconstruction of the original dimensions of the pulley system while stability is ensured by anchoring the onlay graft to the bony insertions of the pulley. Results: Anatomical reconstruction can be achieved with this method. The measured E-space remained 0 mm throughout the recovery, while the graft incorporated as a slim reinforcement of the pulley, displaying no bulkiness. Conclusions: The ideal reconstruction should provide synovial coating and sufficient strength with minimal bulk. Early reconstruction using an onlay graft offers these options. The native synovial lining is preserved and the graft is used to reinforce the pulley.}, language = {en} } @article{JordanBroeerFischeretal.2022, author = {Jordan, Martin C. and Br{\"o}er, David and Fischer, Christian and Heilig, Philipp and Gilbert, Fabian and H{\"o}lscher-Doht, Stefanie and Kalogirou, Charis and Popp, Kevin and Grunz, Jan-Peter and Huflage, Henner and Jakubietz, Rafael G. and Erg{\"u}n, S{\"u}leyman and Meffert, Rainer H.}, title = {Development and preclinical evaluation of a cable-clamp fixation device for a disrupted pubic symphysis}, series = {Communications Medicine}, volume = {2}, journal = {Communications Medicine}, number = {1}, doi = {10.1038/s43856-022-00227-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-299800}, year = {2022}, abstract = {Background Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage. Methods To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility. Results We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation. Conclusion We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.}, language = {en} } @article{HeiligSandnerJordanetal.2021, author = {Heilig, Philipp and Sandner, Phoebe and Jordan, Martin Cornelius and Jakubietz, Rafael Gregor and Meffert, Rainer Heribert and Gbureck, Uwe and Hoelscher-Doht, Stefanie}, title = {Experimental drillable magnesium phosphate cement is a promising alternative to conventional bone cements}, series = {Materials}, volume = {14}, journal = {Materials}, number = {8}, issn = {1996-1944}, doi = {10.3390/ma14081925}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-236633}, year = {2021}, abstract = {Clinically used mineral bone cements lack high strength values, absorbability and drillability. Therefore, magnesium phosphate cements have recently received increasing attention as they unify a high mechanical performance with presumed degradation in vivo. To obtain a drillable cement formulation, farringtonite (Mg\(_3\)(PO\(_4\))\(_2\)) and magnesium oxide (MgO) were modified with the setting retardant phytic acid (C\(_6\)H\(_{18}\)O\(_{24}\)P\(_6\)). In a pre-testing series, 13 different compositions of magnesium phosphate cements were analyzed concentrating on the clinical demands for application. Of these 13 composites, two cement formulations with different phytic acid content (22.5 wt\% and 25 wt\%) were identified to meet clinical demands. Both formulations were evaluated in terms of setting time, injectability, compressive strength, screw pullout tests and biomechanical tests in a clinically relevant fracture model. The cements were used as bone filler of a metaphyseal bone defect alone, and in combination with screws drilled through the cement. Both formulations achieved a setting time of 5 min 30 s and an injectability of 100\%. Compressive strength was shown to be ~12-13 MPa and the overall displacement of the reduced fracture was <2 mm with and without screws. Maximum load until reduced fracture failure was ~2600 N for the cements only and ~3800 N for the combination with screws. Two new compositions of magnesium phosphate cements revealed high strength in clinically relevant biomechanical test set-ups and add clinically desired characteristics to its strength such as injectability and drillability.}, language = {en} } @article{WallstabeBussemerGroeberBeckeretal.2020, author = {Wallstabe, Julia and Bussemer, Lydia and Groeber-Becker, Florian and Freund, Lukas and Alb, Mirian and Dragan, Mariola and Waaga-Gasser, Ana Maria and Jakubietz, Rafael and Kneitz, Hermann and Rosenwald, Andreas and Rebhan, Silke and Walles, Heike and Mielke, Stephan}, title = {Inflammation-Induced Tissue Damage Mimicking GvHD in Human Skin Models as Test Platform for Immunotherapeutics}, series = {ALTEX}, volume = {37}, journal = {ALTEX}, number = {3}, doi = {10.14573/altex.1907181}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-229974}, pages = {429-440}, year = {2020}, abstract = {Due to the rapidly increasing development and use of cellular products, there is a rising demand for non-animal-based test platforms to predict, study and treat undesired immunity. Here, we generated human organotypic skin models from human biopsies by isolating and expanding keratinocytes, fibroblasts and microvascular endothelial cells and seeding these components on a collagen matrix or a biological vascularized scaffold matrix in a bioreactor. We then were able to induce inflammation-mediated tissue damage by adding pre-stimulated, mismatched allogeneic lymphocytes and/or inflammatory cytokine-containing supernatants histomorphologically mimicking severe graft versus host disease (GvHD) of the skin. This could be prevented by the addition of immunosuppressants to the models. Consequently, these models harbor a promising potential to serve as a test platform for the prediction, prevention and treatment of GvHD. They also allow functional studies of immune effectors and suppressors including but not limited to allodepleted lymphocytes, gamma-delta T cells, regulatory T cells and mesenchymal stromal cells, which would otherwise be limited to animal models. Thus, the current test platform, developed with the limitation that no professional antigen presenting cells are in place, could greatly reduce animal testing for investigation of novel immune therapies.}, language = {en} } @article{BernuthVaterFuchsetal.2023, author = {Bernuth, Silvia and Vater, Adrian and Fuchs, Konrad F. and Meffert, Rainer H. and Jakubietz, Rafael G.}, title = {Perfusion changes in perforator-based propeller flaps}, series = {Journal of Reconstructive Microsurgery Open}, volume = {8}, journal = {Journal of Reconstructive Microsurgery Open}, number = {1}, issn = {2377-0813}, doi = {10.1055/a-2086-4988}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-350491}, pages = {e45-e50}, year = {2023}, abstract = {Background  To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible. Methods  A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected. Results  Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day. Conclusion  Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.}, language = {en} }