@article{JanssenHoffmannKannoetal.2020, author = {Janssen, Jan P. and Hoffmann, Jan V. and Kanno, Takayuki and Nose, Naoko and Grunz, Jan-Peter and Onoguchi, Masahisa and Chen, Xinyu and Lapa, Constantin and Buck, Andreas K. and Higuchi, Takahiro}, title = {Capabilities of multi-pinhole SPECT with two stationary detectors for in vivo rat imaging}, series = {Scientific Reports}, volume = {10}, journal = {Scientific Reports}, doi = {10.1038/s41598-020-75696-0}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-230616}, year = {2020}, abstract = {We aimed to investigate the image quality of the U-SPECT5/CT E-Class a micro single-photon emission computed tomography (SPECT) system with two large stationary detectors for visualization of rat hearts and bones using clinically available \(^{99m}\)Tc-labelled tracers. Sensitivity, spatial resolution, uniformity and contrast-to-noise ratio (CNR) of the small-animal SPECT scanner were investigated in phantom studies using an ultra-high-resolution rat and mouse multi-pinhole collimator (UHR-RM). Point source, hot-rod, and uniform phantoms with \(^{99m}\)Tc-solution were scanned for high-count performance assessment and count levels equal to animal scans, respectively. Reconstruction was performed using the similarity-regulated ordered-subsets expectation maximization (SROSEM) algorithm with Gaussian smoothing. Rats were injected with similar to 100 MBq [\(^{99m}\)TcTc-MIBI or similar to 150 MBq [\(^{99m}\)Tc]Tc-HMDP and received multi-frame micro-SPECT imaging after tracer distribution. Animal scans were reconstructed for three different acquisition times and post-processed with different sized Gaussian filters. Following reconstruction, CNR was calculated and image quality evaluated by three independent readers on a five-point scale from 1="very poor" to 5="very good". Point source sensitivity was 567 cps/MBq and radioactive rods as small as 1.2 mm were resolved with the UHR-RM collimator. Collimator-dependent uniformity was 55.5\%. Phantom CNR improved with increasing rod size, filter size and activity concentration. Left ventricle and bone structures were successfully visualized in rat experiments. Image quality was strongly affected by the extent of post-filtering, whereas scan time did not have substantial influence on visual assessment. Good image quality was achieved for resolution range greater than 1.8 mm in bone and 2.8 mm in heart. The recently introduced small animal SPECT system with two stationary detectors and UHR-RM collimator is capable to provide excellent image quality in heart and bone scans in a rat using standardized reconstruction parameters and appropriate post-filtering. However, there are still challenges in achieving maximum system resolution in the sub-millimeter range with in vivo settings under limited injection dose and acquisition time.}, language = {en} } @article{IsraelRiehlButtetal.2023, author = {Israel, Ina and Riehl, Gabriele and Butt, Elke and Buck, Andreas K. and Samnick, Samuel}, title = {Gallium-68-labeled KISS1-54 peptide for mapping KISS1 receptor via PET: initial evaluation in human tumor cell lines and in tumor-bearing mice}, series = {Pharmaceuticals}, volume = {17}, journal = {Pharmaceuticals}, number = {1}, issn = {1424-8247}, doi = {10.3390/ph17010044}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-355898}, year = {2023}, abstract = {Kisspeptins (KPs, KISS1) and their receptor (KISS1R) play a pivotal role as metastasis suppressor for many cancers. Low or lost KP expression is associated with higher tumor grade, increased metastatic potential, and poor prognosis. Therefore, KP expression has prognostic relevance and correlates with invasiveness in cancers. Furthermore, KISS1R represents a very promising target for molecular imaging and therapy for KISS1R-expressing tumors. The goal of this study was to evaluate the developed KISS1-54 derivative, [\(^{68}\)Ga]KISS1-54, as a PET-imaging probe for KISS1R-expressing tumors. The NODAGA-KISS1-54 peptide was labeled by Gallium-68, and the stability of the resulting [\(^{68}\)Ga]KISS1-54 evaluated in injection solution and human serum, followed by an examination in different KISS1R-expressing tumor cell lines, including HepG2, HeLa, MDA-MB-231, MCF7, LNCap, SK-BR-3, and HCT116. Finally, [\(^{68}\)Ga]KISS1-54 was tested in LNCap- and MDA-MB-231-bearing mice, using µ-PET, assessing its potential as an imaging probe for PET. [\(^{68}\)Ga]KISS1-54 was obtained in a 77 ± 7\% radiochemical yield and at a >99\% purity. The [\(^{68}\)Ga]KISS1-54 cell uptake amounted to 0.6-4.4\% per 100,000 cells. Moreover, the accumulation of [\(^{68}\)Ga]KISS1-54 was effectively inhibited by nonradioactive KISS1-54. In [\(^{68}\)Ga]KISS1-54-PET, KISS1R-positive LNCap-tumors were clearly visualized as compared to MDA-MB-231-tumor implant with predominantly intracellular KISS1R expression. Our first results suggest that [\(^{68}\)Ga]KISS1-54 is a promising candidate for a radiotracer for targeting KISS1R-expressing tumors via PET.}, language = {en} } @phdthesis{Kemmer2024, author = {Kemmer, Luisa Diana}, title = {Darstellung von Inflammation in Atherosklerose mit dem CXCR4-gerichteten PET-Tracer \(^{68}\)Ga-Pentixafor im Vergleich zur \(^{18}\)F-FDG-PET/CT}, doi = {10.25972/OPUS-36001}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-360013}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Herz-Kreislauf-Erkrankungen z{\"a}hlen zu den h{\"a}ufigsten Todesursachen weltweit. Ein ihr zugrundeliegender pathologischer Prozess ist die Atherosklerose. Die Ruptur eines atheroskelrotischen Plaques kann lebensbedrohlich sein. Derzeit existieren weder ein evaluierter Biomarker noch eine Bildgebungstechnik, die das Risiko einer solchen Plaqueruptur und eines nachfolgenden akuten kardiovaskul{\"a}ren Ereignisses vorhersagen k{\"o}nnen. Um die bildgebenden Verfahren zur Detektion der Atherosklerose zu optimieren, wurde in dieser Dissertationsarbeit untersucht, ob der PET/CT-Tracer 68Ga-Pentixafor im Vergleich zu 18F-FDG bessere Ergebnisse in der Diagnostik der Atherosklerose erzielen kann. Insgesamt wurden 144 onkologische Patienten in die Studie einbezogen, bei denen die 18F-FDG-PET/CT sowie 68Ga-Pentifaxor-PET/CT aus klinischen Gr{\"u}nden indiziert waren. Befunde, bei denen eine gegen{\"u}ber dem Hintergrund vermehrte Speicherung ohne physiologische Erkl{\"a}rung nachgewiesen werden konnte, wurden als positiv bewertet. Um Unterschiede zwischen den Patienten außer Acht lassen zu k{\"o}nnen, wurde die target-to-background-ratio (TBR) berechnet. Zur Beschreibung der Speicherintensit{\"a}t einer L{\"a}sion wurde der standardized uptake value (SUV) bestimmt. Nach Auswertung der Daten zeigte sich eine m{\"a}ßige Korrelation der Anzahl von 68Ga-Pentixafor-positiven L{\"a}sionen mit der Anzahl der 18F-FDG positiven L{\"a}sionen. Die CXCR4-gerichtete Bildgebung mit 68Ga-Pentixafor identifizierte mehr L{\"a}sionen als die 18F-FDG-PET/CT. Bez{\"u}glich ihres Verteilungsmusters wiesen die beiden Tracer eine geringe Korrelation auf. Die Aufnahmeintensit{\"a}t beider Tracer korrelierte umgekehrt mit dem Ausmaß der Verkalkung. Stark verkalkte Plaques zeigten die niedrigste Traceraufnahme f{\"u}r beide PET-Tracer. Weitere Studien zur Aufkl{\"a}rung der zugrunde liegenden biologischen Mechanismen und Quellen der CXCR4-Positivit{\"a}t sind in hohem Maße gerechtfertigt.}, subject = {Arteriosklerose}, language = {de} } @phdthesis{Heinrich2024, author = {Heinrich, Marieke}, title = {Bildgebung des Prostatakarzinoms im PSMA-PET/CT: Die halbautomatische Quantifizierung des Tumorvolumens zeigt (noch) keine verbesserte Pr{\"a}diktion des Krankheitsverlaufs}, doi = {10.25972/OPUS-35968}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-359684}, school = {Universit{\"a}t W{\"u}rzburg}, year = {2024}, abstract = {Die molekularen Parameter PSMA-TV und TL-PSMA im 68Ga-PSMA PET/CT leiten sich ab von MTV und TLG im FDG PET/CT. Mit der vorliegenden Arbeit wurden die Grenzen neuer Autosegmentierungsprogramme durch eine maximale Belastung mit großen Tumorvolumina von Patienten unter taxanbasierter Chemotherapie ausgelotet. Die Programme Syngo.via und FIJI kamen zu vergleichbaren Ergebnissen. Patienten mit einem Gleason Score von 8-10 zeigten unter Therapie eine signifikante Zunahme des PSMA-TV und TL-PSMA im Gegensatz zu Patienten mit Gleason Score 6-7b. Ein hoher PSA-Wert korrelierte zu allen Zeitpunkten signifikant mit einem hohen PSMA-TV und TL-PSMA, ebenso korrelierte ein steigender PSA-Wert signifikant mit steigenden Werten in PSMA-TV und TL-PSMA. Patienten mit einem biochemischen Progress und einem Progress nach modifiziertem PERCIST zeigten vor Therapie ein signifikant h{\"o}heres PSMA-TV und TL-PSMA als Patienten ohne Progress und unter Therapie eine signifikante Zunahme des PSMA-TV und TL-PSMA im Vergleich zu Patienten ohne Progress. Eine Einteilung des Therapieansprechens aller Patienten in CR, PR, SD und PD nach PSMA-TV, TL-PSMA, PSA-Wert und modifiziertem PERCIST stimmte nicht in allen Patienten {\"u}berein. Ein signifikant k{\"u}rzeres Gesamt{\"u}berleben zeigten lediglich Patienten mit einem nach dem PSA-Wert definiertem Progress. Im praktischen Vergleich der beiden Programme ben{\"o}tigte Syngo.via f{\"u}r eine komplette Segmentierung signifikant mehr Zeit als FIJI, vor allem da der Wechsel von VOI zu VOI signifikant l{\"a}nger dauerte. Unabh{\"a}ngig vom Autosegmentierungsprogramm dauerte eine komplette Segmentierung l{\"a}nger, je gr{\"o}ßer das PSMA-TV und das TL-PSMA war, je mehr VOIs das Programm automatisch setzte und je mehr VOIs manuell gel{\"o}scht und neu gesetzt wurden. In der Gesamtschau bieten PSMA-TV und TL-PSMA in Kombination mit den sich schnell weiterentwickelnden Autosegmentierungs-Programmen die M{\"o}glichkeit, auch sehr hohe Tumorlasten des PCas objektiv und vergleichbar zu beschreiben.}, subject = {Hormonrefrakt{\"a}rer Prostatakrebs}, language = {de} } @article{SelcukTokluBeykanetal.2018, author = {Selcuk, Nalan Alan and Toklu, Turkay and Beykan, Seval and Karaaslan, Serife Ipek}, title = {Evaluation of the dosimetry approaches in ablation treatment of thyroid cancer}, series = {Journal of Applied Clinical Medical Physics}, volume = {19}, journal = {Journal of Applied Clinical Medical Physics}, doi = {10.1002/acm2.12350}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-235882}, pages = {134-140}, year = {2018}, abstract = {In this study, we aimed to evaluate dosimetric approaches in ablation treatment of Differentiated Thyroid Carcinoma (DTC) without interrupting the clinical routine. Prior to therapy, 10.7 MBq 131I in average was orally given to 24 patients suffering from DTC. MIRD formalism was used for dosimetric calculations. For blood and bone marrow dosimetry, blood samples and whole-body counts were collected at 2, 24, 72, and 120 h after I-131 administration. For remnant tissue dosimetry, uptake measurements were performed at the same time intervals. To estimate the remnant volume, anterior and lateral planar gamma camera images were acquired with a reference source within the field of view at 24 h after I-131 administration. Ultrasound imaging was also performed. Treatment activities determined with the fixed activity method were administered to the patients. Secondary cancer risk relative to applied therapy was evaluated for dosimetric approaches. The average dose to blood and bone marrow were determined as 0.15 ± 0.04 and 0.11 ± 0.04 Gy/GBq, respectively. The average remnant tissue dose was 0.58 ± 0.52 Gy/MBq and the corresponding required activity to ablate the remnant was approximately 1.3 GBq of 131I. A strong correlation between 24th-hour uptake and time-integrated activity coefficient values was obtained. Compared to fixed activity method, approximately five times higher secondary cancer risk was determined in bone marrow dosimetry, while the risk was about three times lower in lesion-based dosimetry.}, language = {en} } @article{AngayFriedrichPinneckeretal.2018, author = {Angay, Oguzhan and Friedrich, Mike and Pinnecker, J{\"u}rgen and Hintzsche, Henning and Stopper, Helga and Hempel, Klaus and Heinze, Katrin G.}, title = {Image-based modeling and scoring of Howell-Jolly Bodies in human erythrocytes}, series = {Cytometry Part A}, volume = {93}, journal = {Cytometry Part A}, doi = {10.1002/cyto.a.23123}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-221140}, pages = {305-313}, year = {2018}, abstract = {The spleen selectively removes cells with intracellular inclusions, for example, detached nuclear fragments in circulating erythrocytes, called Howell-Jolly Bodies (HJBs). With absent or deficient splenic function HJBs appear in the peripheral blood and can be used as a simple and non-invasive risk-indicator for fulminant potentially life-threatening infection after spleenectomy. However, it is still under debate whether counting of the rare HJBs is a reliable measure of splenic function. Investigating HJBs in premature erythrocytes from patients during radioiodine therapy gives about 10 thousand times higher HJB counts than in blood smears. However, we show that there is still the risk of false-positive results by unspecific nuclear remnants in the prepared samples that do not originate from HJBs, but from cell debris residing above or below the cell. Therefore, we present a method to improve accuracy of image-based tests that can be performed even in non-specialized medical institutions. We show how to selectively label HJB-like clusters in human blood samples and how to only count those that are undoubtedly inside the cell. We found a "critical distance" dcrit referring to a relative HJB-Cell distance that true HJBs do not exceed. To rule out false-positive counts we present a simple inside-outside-rule based on dcrit—a robust threshold that can be easily assessed by combining conventional 2D imaging and straight-forward image analysis. Besides data based on fluorescence imaging, simulations of randomly distributed HJB-like objects on realistically modelled cell objects demonstrate the risk and impact of biased counting in conventional analysis. © 2017 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC.}, language = {en} } @article{LinzBrandsHerterichetal.2021, author = {Linz, Christian and Brands, Roman C. and Herterich, Theresia and Hartmann, Stefan and M{\"u}ller-Richter, Urs and K{\"u}bler, Alexander C. and Haug, Lukas and Kertels, Olivia and Bley, Thorsten A. and Dierks, Alexander and Buck, Andreas K. and Lapa, Constantin and Brumberg, Joachim}, title = {Accuracy of 18-F Fluorodeoxyglucose Positron Emission Tomographic/Computed Tomographic Imaging in Primary Staging of Squamous Cell Carcinoma of the Oral Cavity}, series = {JAMA Network Open}, volume = {4}, journal = {JAMA Network Open}, doi = {10.1001/jamanetworkopen.2021.7083}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-369313}, year = {2021}, abstract = {Importance Squamous cell carcinoma (SCC) of the oral cavity is one of the most common tumor entities worldwide. Precise initial staging is necessary to determine a diagnosis, treatment, and prognosis. Objective To examine the diagnostic accuracy of preoperative 18-F fluorodeoxyglucose (FDG) positron emission tomographic/computed tomographic (PET/CT) imaging in detecting cervical lymph node metastases. Design, Setting, and Participants This prospective diagnostic study was performed at a single tertiary reference center between June 1, 2013, and January 31, 2016. Data were analyzed from April 7, 2018, through May 31, 2019. Observers of the FDG PET/CT imaging were blinded to patients' tumor stage. A total of 150 treatment-naive patients with clinical suspicion of SCC of the oral cavity were enrolled. Exposures All patients underwent FDG PET/CT imaging before local tumor resection with selective or complete neck dissection. Main Outcomes and Measures The accuracy of FDG PET/CT in localizing primary tumor, lymph node, and distant metastases was tested. Histopathologic characteristics of the tissue samples served as the standard of reference. Results Of the 150 patients enrolled, 135 patients (74 [54.8\%] men) with a median age of 63 years (range, 23-88 years) met the inclusion criteria (histopathologically confirmed primary SCC of the oral cavity/level-based histopathologic assessment of the resected lymph nodes). Thirty-six patients (26.7\%) in the study cohort had neck metastases. Use of FDG PET/CT detected cervical lymph node metastasis with 83.3\% sensitivity (95\% CI, 71.2\%-95.5\%) and 84.8\% specificity (95\% CI, 77.8\%-91.9\%) and had a negative predictive value of 93.3\% (95\% CI, 88.2\%-98.5\%). The specificity was higher than for contrast-enhanced cervical CT imaging (67.0\%; 95\% CI, 57.4\%-76.7\%; P < .01) and cervical magnetic resonance imaging (62.6\%; 95\% CI, 52.7\%-72.6\%; P < .001). Ipsilateral lymph node metastasis in left- or right-sided primary tumor sites was detected with 78.6\% sensitivity (95\% CI, 63.4\%-93.8\%) and 83.1\% specificity (95\% CI, 75.1\%-91.2\%), and contralateral metastatic involvement was detected with 66.7\% sensitivity (95\% CI, 28.9\%-100.0\%) and 98.6\% specificity (95\% CI, 95.9\%-100.0\%). No distant metastases were observed. Conclusions and Relevance In this study, FDG PET/CT imaging had a high negative predictive value in detecting cervical lymph node metastasis in patients with newly diagnosed, treatment-naive SCC of the oral cavity. Routine clinical use of FDG PET/CT might lead to a substantial reduction of treatment-related morbidity in most patients.}, language = {en} } @article{LinzBrandsKertelsetal.2021, author = {Linz, Christian and Brands, Roman C. and Kertels, Olivia and Dierks, Alexander and Brumberg, Joachim and Gerhard-Hartmann, Elena and Hartmann, Stefan and Schirbel, Andreas and Serfling, Sebastian and Zhi, Yingjun and Buck, Andreas K. and K{\"u}bler, Alexander and Hohm, Julian and Lapa, Constantin and Kircher, Malte}, title = {Targeting fibroblast activation protein in newly diagnosed squamous cell carcinoma of the oral cavity - initial experience and comparison to [18F]FDG PET/CT and MRI}, series = {European Journal of Nuclear Medicine and Molecular Imaging}, volume = {48}, journal = {European Journal of Nuclear Medicine and Molecular Imaging}, doi = {10.1007/s00259-021-05422-z}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-369331}, pages = {3951-3960}, year = {2021}, abstract = {Purpose While [18F]-fluorodeoxyglucose ([18F]FDG) is the standard for positron emission tomography/computed tomography (PET/CT) imaging of oral squamous cell carcinoma (OSCC), diagnostic specificity is hampered by uptake in inflammatory cells such as neutrophils or macrophages. Recently, molecular imaging probes targeting fibroblast activation protein α (FAP), which is overexpressed in a variety of cancer-associated fibroblasts, have become available and might constitute a feasible alternative to FDG PET/CT. Methods Ten consecutive, treatment-na{\"i}ve patients (8 males, 2 females; mean age, 62 ± 9 years) with biopsy-proven OSCC underwent both whole-body [18F]FDG and [68Ga]FAPI-04 (FAP-directed) PET/CT for primary staging prior to tumor resection and cervical lymph node dissection. Detection of the primary tumor, as well as the presence and number of lymph node and distant metastases was analysed. Intensity of tracer accumulation was assessed by means of maximum (SUVmax) and peak (SUVpeak) standardized uptake values. Histological work-up including immunohistochemical staining for FAP served as standard of reference. Results [18F]FDG and FAP-directed PET/CT detected all primary tumors with a SUVmax of 25.5 ± 13.2 (FDG) and 20.5 ± 6.4 (FAP-directed) and a SUVpeak of 16.1 ± 10.3 ([18F]FDG) and 13.8 ± 3.9 (FAP-directed), respectively. Regarding cervical lymph node metastases, FAP-directed PET/CT demonstrated comparable sensitivity (81.3\% vs. 87.5\%; P = 0.32) and specificity (93.3\% vs. 81.3\%; P = 0.16) to [18F]FDG PET/CT. FAP expression on the cell surface of cancer-associated fibroblasts in both primary lesions as well as lymph nodes metastases was confirmed in all samples. Conclusion FAP-directed PET/CT in OSCC seems feasible. Future research to investigate its potential to improve patient staging is highly warranted.}, language = {en} } @article{LewisHabringerKircheretal.2021, author = {Lewis, Richard and Habringer, Stefan and Kircher, Malte and Hefter, Maike and Peuker, Caroline Anna and Werner, Rudolf and Ademaj-Kospiri, Val{\"e}za and G{\"a}ble, Alexander and Weber, Wolfgang and Wester, Hans-J{\"u}rgen and Buck, Andreas and Herhaus, Peter and Lapa, Constantin and Keller, Ulrich}, title = {Investigation of spleen CXCR4 expression by [68Ga]Pentixafor PET in a cohort of 145 solid cancer patients}, series = {EJNMMI Research}, volume = {11}, journal = {EJNMMI Research}, doi = {10.1186/s13550-021-00822-6}, url = {http://nbn-resolving.de/urn:nbn:de:bvb:20-opus-363820}, year = {2021}, abstract = {Background The chemokine receptor CXCR4 is frequently overexpressed and associated with adverse prognosis in most hematopoietic malignancies and solid cancers. Recently, CXCR4 molecular imaging using the CXCR4-specific positron emission tomography (PET) tracer Pentixafor ([68Ga]Pentixafor) has become a well-established method to non-invasively measure CXCR4 expression in vivo. In previous Pentixafor imaging studies, highly variable CXCR4 tracer uptake to the spleen was observed. Results We investigated the hypothesis that enhanced spleen [68Ga]Pentixafor uptake and thus CXCR4 expression in patients with solid tumors would indicate an activated spleen state and/or an association with clinical and prognostic features and survival parameters. In this retrospective study, [68Ga]Pentixafor-PET images and patient records of 145 solid tumor patients representing 27 cancer entities were investigated for an association of spleen [68Ga]Pentixafor uptake and clinical characteristics and outcome. Based on this assessment, we did not observe differences in clinical outcomes, measured by progression-free survival, overall survival and remission status neither within the entire cohort nor within subgroups of adrenal cancer, desmoplastic small round cell tumor, neuroendocrine tumors, non-small cell lung cancer, small cell lung cancer and pancreatic adenocarcinoma patients. No tumor entity showed especially high levels of spleen [68Ga]Pentixafor uptake compared to others or a control cohort. However, when investigating laboratory parameters, there was a positive correlation of high spleen [68Ga]Pentixafor uptake with leukocyte and/or platelet counts in neuroendocrine tumors, non-small cell lung cancer and small cell lung cancer. Conclusion Spleen [68Ga]Pentixafor uptake was not associated with stage of disease and clinical outcomes in solid tumor patients. We identified positively associated platelet and/or leukocyte counts with spleen [68Ga]Pentixafor uptake in neuroendocrine tumors, non-small cell lung cancer and small cell lung cancer, suggesting that splenic CXCR4 expression could possibly play a role in systemic immunity/inflammation in some types of solid tumors or a subgroup of patients within solid tumor entities.}, language = {en} }